Plan Review Details - Permit 19080775
Plan Review Stops For Permit 19080775 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-10-17 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-10-17 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-10-17 |
Time |
14:09 |
Sent To |
|
|
Notes |
2019-10-17 15:47:15 | PROVISOS: | | DEFERRED SUBMITTALS - ROOF TRUSS SHOP DWGS TO INSPECTOR | | PRIOR TO INSTALLATION. | | PROVIDE ROOFING (TILE) ATTACHMENT WITH ROOFING SUB | | PERMIT | | SEPARATE PERMITS REQUIRED FOR- | | DRIVEWAY | | FENCING | | SUBMIT PRODUCT APPROVAL FOR GARAGE DOOR | | CONSTRUCTION HOURS - 7AM TO 7PM MON-FRI, 8AM TO 8PM | | SAT-SUN |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-09-06 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-09-06 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-09-06 |
Time |
07:52 |
Sent To |
|
|
Notes |
2019-09-06 16:06:04 | BUILDING REVIEW COMMENTS: | | | | W.P.B. PERMIT: 19080775 | | REVIEWED: SEPTEMBER 6, 2019 | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER PX4191 | | [email protected] | | 561-805-6718 | | | | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) | | FBC[B] = FBC BUILDING | | FBC[EXISTING] = FBC EXISTING BUILDING | | FBC[A] = FBC ACCESSIBILITY | | FBC[E] = FBC ENERGY CONSERVATION | | FBC[R] = FBC RESIDENTIAL | | | | 1) 301.2(7)FIGURE FBC[R]PROVIDE WIND DIAGRAM THAT | | MATCHES THE ROOF CONDITION OF THIS HOUSE. | | | | 2) 107.3.5.3 FBC[AMENDED] PROVIDE SEDIMENT CONTROL TO | | KEEP CONSTRUCTION DEBRIS FROM ENTERING ADJACENT | | PROPERTIES AND STORM DRAINS DURING CONSTRUCTION. YOU | | CAN JUST ADD SILT FENCE DETAIL AND HOW DRAINS ARE | | PROTECTED TO THE DRAINAGE PLAN. SOME ENGINEERING | | STANDARD DETAILS CAN BE USED FROM WPB WEBSITE-POLLUTION | | CONTROL. HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUB | | LIC-WORKS/FORMS,-PERMITS-APPLICATIONS | | | | 3) [FBC 107.5][FBC 110.9][FBC R401.3][PROVIDE SITE | | DRAINAGE PLAN. SURFACE DRAINAGE SHALL BE DIVERTED TO A | | STORM SEWER CONVEYANCE OR OTHER APPROVED POINT OF | | COLLECTION THAT DOES NOT CREATE A HAZARD. LOTS SHALL BE | | GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION | | WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 INCHES | | WITHIN THE FIRST 10 FEET. EXCEPTION: WHERE LOT LINES, | | WALLS, SLOPES OR OTHER PHYSICAL BARRIERS PROHIBIT 6 | | INCHES OF FALL WITHIN 10 FEET (3048 MM), DRAINS OR | | SWALES SHALL BE CONSTRUCTED TO ENSURE DRAINAGE AWAY | | FROM THE STRUCTURE. IMPERVIOUS SURFACES WITHIN 10 FEET | | OF THE BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF | | 2 PERCENT AWAY FROM THE BUILDING. | | - | | | | 4) 403.1.7.3 FBC[R] FOUNDATION ELEVATION. ON GRADED | | SITES, THE TOP OF ANY EXTERIOR FOUNDATION SHALL EXTEND | | ABOVE THE ELEVATION OF THE STREET GUTTER AT POINT OF | | DISCHARGE OR THE INLET OF AN APPROVED DRAINAGE DEVICE A | | MINIMUM OF 12 INCHES (305 MM) PLUS 2 PERCENT. ALTERNATE | | ELEVATIONS ARE PERMITTED SUBJECT TO THE APPROVAL OF THE | | BUILDING OFFICIAL, PROVIDED IT CAN BE DEMONSTRATED THAT | | REQUIRED DRAINAGE TO THE POINT OF DISCHARGE AND AWAY | | FROM THE STRUCTURE IS PROVIDED AT ALL LOCATIONS ON THE | | SITE. | | | | 5) 703.4 FBC[R] PROVIDE TYPE OF WINDOW/DOOR FLASHING TO | | BE USED TO MEET REQUIREMENTS OF R703.4 | | | | 6) 302.10 FBC[R] PROVIDE CUT SHEET FOR ICYNENE(ICC-ES | | REPORT OR EQUAL) WITH THE TYPE SELECTED TO ESTABLISH | | THICKNESS NEEDED TO MEET REQUIRED R-VALUE, FLAME SPREAD | | INDEX AND SMOKE DEVELOPED INDEX. | | | | 7) INDICATE THE ROOF TILE ATTACHMENT METHOD THAT WILL | | BE USED BY MARKING THE APPROPRIATE INFORMATION ON THE | | PRODUCT APPROVAL. FBC 107.2.1 IF AN ADHESIVE WILL BE | | USED, SUBMIT THE PRODUCT APPROVAL FOR IT. FBC 107.3.4 | | IF A MORTAR OR ADHESIVE SET IS USED SUBMIT THE PRODUCT | | APPROVAL FOR THE UNDERLAYMENT TO SHOW THAT IT WILL MEET | | WINDLOADS. | | | | 8) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS FOR | | SLIDING GLASS DOOR, ARCH WINDOWS AND MULL BETWEEN, OR | | INDICATE THAT YOU WOULD LIKE IT DEFERRED. | | | | 9) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS FOR | | TILE ROOFING ADHESIVE, OR INDICATE THAT YOU WOULD LIKE | | IT DEFERRED. | | | | PROVISOS: | | DEFERRED SUBMITTALS - ROOF TRUSS SHOP DWGS TO INSPECTOR | | PRIOR TO INSTALLATION. | | PROVIDE ROOFING (TILE) ATTACHMENT OR INDICATE THAT IT | | WILL BE DEFERRED UNTIL ROOFING SUB PERMIT IS APPLIED | | FOR. | | SEPARATE PERMITS REQUIRED FOR- | | DRIVEWAY | | FENCING | | CONSTRUCTION HOURS - 7AM TO 7PM MON-FRI, 8AM TO 8PM | | SAT-SUN | | - PROVISOS WILL BE ADDED TO THE PLANS AT FINAL | | STAMPING. | | | | | | NOTES: | | | | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | EACH COMMENT IS BEING ADDRESSED. | | | | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW | | OF MATERIALS REQUESTED. | | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | [email protected] | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2019-10-18 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-10-18 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-10-18 |
Time |
11:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-09-09 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-09-09 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-09-09 |
Time |
13:02 |
Sent To |
|
|
Notes |
2019-09-09 14:37:51 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. FEED TO MAIN HOUSE PANEL IS REQUIRED TO HAVE AN | | EQUIPMENT GROUNDING CONDUCTOR, SIZED PER CODE. PROVIDE | | CORRECTION. NEC 250.122; FBC RE E3704.6, 3607.3.1 | | 2. PROVIDE GROUNDING ELECTRODE SYSTEM FOR MAIN HOUSE AS | | REQUIRED FOR A BUILDING OR STRUCTURE SUPPLIED BY A | | FEEDER OR BRANCH CIRCUIT. NEC 250.32; FBC RE3607.3 | | 3. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | MAIN BREAKER AT THE PANEL FOR THE MAIN HOUSE PANEL. NEC | | 225.31, 225.32 | | 4. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC | | RE E3606.3 | | 5. AFCI PROTECTION SHOWN IN NOTE 18 IS NOT CODE | | COMPLIANT. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902 | | 6. LIGHTING IN CLOSETS APPEARS TO BE STANDARD RECESS | | LIGHTS. PER CODE, LIGHTING WITH OPEN OR PARTIALLY | | ENCLOSED LAMPS AND PENDANT LUMINAIRES OR LAMPHOLDERS | | SHALL NOT BE PERMITTED IN CLOTHES CLOSETS. PROVIDE | | CORRECTION. NEC 410.16; FBC RE E4003.12 | | 7. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | 8. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE | | OUTLETS IN GARAGE, INCLUDING THE GARAGE DOOR OPENER. | | PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.2 | | 9. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE CIRCUITS, | | AND AFCI OR GFCI PROTECTION WHERE APPLICABLE TO COMPLY | | WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, 215.5, | | 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2019-08-26 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-08-26 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2019-08-26 |
Time |
16:56 |
Sent To |
|
|
Notes |
2019-08-26 16:56:38 | GAS PERMIT AND REVIEW UNDER 19081201 |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-10-10 |
Time |
|
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2019-10-10 |
Time |
11:19 |
Sent To |
PC |
|
Notes |
2019-10-10 11:19:55 | THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING | | CONDITION(S): | | 1. A SEPARATE PERMIT IS REQUIRED FOR: FENCE/WALL, | | AWNINGS, GENERATOR, MECHANICAL/AC/POOL EQUIPMENT, | | IRRIGATION, LANDSCAPE, AND DRIVEWAY. | | 2. THIS PERMIT DOES NOT APPROVE ITEMS THAT HAVE BEEN | | DEFERRED SUCH AS THE GARAGE DOOR AND ROOFING MATERIAL. | | 3. ALL WINDOWS AND DOORS SHALL HAVE CLEAR GLASS OR | | CLEAR GLASS WITH LOW-E COATING. | | 4. ALL WINDOWS AND DOORS SHALL HAVE EXTERNAL OGEE | | DIMENSIONAL MUNTINS. | | 5. ALL WINDOWS FRAMES SHALL BE WHITE OR BRONZE IN | | COLOR. | | 6. ALL WINDOWS SHALL BE INSET WITHIN THE WINDOW FRAME | | OPENING. A FLUSH INSTALLATION WITH EXTERIOR WALL IS | | PROHIBITED. | | 7. THE APPLICANT SHALL CONFIRM WITH HISTORIC | | PRESERVATION PRIOR TO PURCHASING AND INSTALLING FRONT | | DOOR AND SIDELITES. | | 8. A LANDSCAPING PERMIT WILL BE SUBMITTED AND COMPLY | | WITH THE LANDSCAPING REQUIREMENTS FOR THE CITY OF WEST | | PALM BEACH. (CONDITIONAL APPROVAL FORM IS ATTACHED TO | | EACH PLAN) | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | AARON BORNGRABER | | HISTORIC PRESERVATION PLANNER | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | T: 561-822-1428 | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2019-08-19 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2019-08-19 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2019-08-16 |
Time |
12:10 |
Sent To |
PC |
|
Notes |
2019-08-19 11:04:31 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | 1. A LANDSCAPING PERMIT SHALL BE SUBMITTED PRIOR TO | | RECEIVING APPROVAL OF THIS REVIEW. ILLUSTRATE | | COMPLIANCE WITH A MINIMUM OF 75% OF THE FRONT YARD AREA | | SHALL BE LIVING PLANT MATERIAL. | | 2. A SEPARATE PERMIT IS REQUIRED FOR: FENCE/WALL, | | AWNINGS, SIGNS, PARKING LOT, GENERATOR, | | MECHANICAL/AC/POOL EQUIPMENT, DUMPSTER ENCLOSURE, | | IRRIGATION, LANDSCAPE, AND DRIVEWAY. PLEASE CONFIRM | | THAT THIS IS UNDERSTOOD. | | 3. PROVIDE A PRODUCT APPROVAL FOR THE GARAGE DOOR TO BE | | USED. | | 4. THE PLANS SHOW A BARREL TILE TO BE USED. A PRODUCT | | APPROVAL FOR S-TILE WAS SUBMITTED WITH THE PERMIT. | | REVISE AND INCLUDE COLOR OF THE TILE TO BE USED. | | 5. THE PLANS ILLUSTRATE A SLIDING GLASS DOOR IN THE | | REAR. A PRODUCT APPROVAL WAS NOT SUBMITTED WITH THE | | PERMIT. PLEASE INCLUDE. | | | | THE FOLLOWING ARE PROPOSED CONDITIONS OF APPROVAL, | | ADDITIONAL CONDITIONS MAY BE ADDED AFTER RESUBMITTAL. | | PLEASE CONFIRM THAT THESE CONDITIONS WILL BE COMPLIED | | WITH. | | | | A. ALL WINDOWS AND DOORS SHALL HAVE CLEAR GLASS OR | | CLEAR GLASS WITH LOW-E COATING. | | B. ALL WINDOWS AND DOORS SHALL HAVE EXTERNAL OGEE | | DIMENSIONAL MUNTINS. | | C. ALL WINDOW FRAMES SHALL BE WHITE OR BRONZE IN COLOR. | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | AARON BORNGRABER | | HISTORIC PRESERVATION PLANNER | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | T: 561-822-1428 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-10-18 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-10-04 |
Time |
14:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-09-13 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2019-09-13 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2019-08-14 |
Time |
13:07 |
Sent To |
|
|
Notes |
2019-09-13 09:32:21 | TO HM DESK | | | | | 2019-08-15 13:07:57 | R20 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2019-10-24 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-10-24 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-10-24 |
Time |
08:16 |
Sent To |
|
|
Notes |
2019-10-24 08:17:11 | OK-STAMP ON PLANS | | MU-2019-032911-0000 |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2019-09-06 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-09-06 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-09-06 |
Time |
07:52 |
Sent To |
|
|
Notes |
2019-09-06 13:17:55 | 109 FBC[AMENDED] PLANS REQUIRE REVIEW BY THE PBC IMPACT | | FEE OFFICE. ?CALL (561) 233-5025. ?UPON APPROVAL, YOU | | MAY CHECK OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR | | REVIEW. ?PLEASE RETURNED STAMPED AND WITH A COPY OF THE | | RECEIPT AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO THE PBC IMPACT FEE | | OFFICE. THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGO | | V.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONN | | AIRE.PDF |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2019-09-13 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2019-09-13 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2019-09-13 |
Time |
10:55 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2019-08-30 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-08-30 |
Time |
13:27 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2019-08-29 |
Time |
07:30 |
Sent To |
|
|
Notes |
2019-08-29 16:10:12 | 08/29/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6720 | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
N |
Date |
2019-10-17 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-10-17 |
Time |
15:45 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-10-17 |
Time |
15:40 |
Sent To |
|
|
Notes |
2019-10-24 08:17:47 | ROOFING PRODUCT APPROVAL DUE WITH SUB PERMIT | | APPLICATION. |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2019-09-06 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-09-06 |
Time |
16:04 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-09-06 |
Time |
07:52 |
Sent To |
|
|
Notes |
2019-09-06 16:05:04 | SEE BUILDING COMMENT #9 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2019-10-11 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2019-10-11 |
Time |
08:26 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2019-10-09 |
Time |
16:03 |
Sent To |
PC |
|
Notes |
2019-10-10 11:20:07 | THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING | | CONDITION(S): | | 1. A SEPARATE PERMIT IS REQUIRED FOR: FENCE/WALL, | | AWNINGS, GENERATOR, MECHANICAL/AC/POOL EQUIPMENT, | | IRRIGATION, LANDSCAPE, AND DRIVEWAY. | | 2. THIS PERMIT DOES NOT APPROVE ITEMS THAT HAVE BEEN | | DEFERRED SUCH AS THE GARAGE DOOR AND ROOFING MATERIAL. | | 3. ALL WINDOWS AND DOORS SHALL HAVE CLEAR GLASS OR | | CLEAR GLASS WITH LOW-E COATING. | | 4. ALL WINDOWS AND DOORS SHALL HAVE EXTERNAL OGEE | | DIMENSIONAL MUNTINS. | | 5. ALL WINDOWS FRAMES SHALL BE WHITE OR BRONZE IN | | COLOR. | | 6. ALL WINDOWS SHALL BE INSET WITHIN THE WINDOW FRAME | | OPENING. A FLUSH INSTALLATION WITH EXTERIOR WALL IS | | PROHIBITED. | | 7. THE APPLICANT SHALL CONFIRM WITH HISTORIC | | PRESERVATION PRIOR TO PURCHASING AND INSTALLING FRONT | | DOOR AND SIDELITES. | | 8. A LANDSCAPING PERMIT WILL BE SUBMITTED AND COMPLY | | WITH THE LANDSCAPING REQUIREMENTS FOR THE CITY OF WEST | | PALM BEACH. (CONDITIONAL APPROVAL FORM IS ATTACHED TO | | EACH PLAN) | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | AARON BORNGRABER | | HISTORIC PRESERVATION PLANNER | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | T: 561-822-1428 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2019-08-19 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2019-08-19 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2019-08-19 |
Time |
11:04 |
Sent To |
PC |
|
Notes |
2019-08-19 11:04:48 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | 1. A LANDSCAPING PERMIT SHALL BE SUBMITTED PRIOR TO | | RECEIVING APPROVAL OF THIS REVIEW. ILLUSTRATE | | COMPLIANCE WITH A MINIMUM OF 75% OF THE FRONT YARD AREA | | SHALL BE LIVING PLANT MATERIAL. | | 2. A SEPARATE PERMIT IS REQUIRED FOR: FENCE/WALL, | | AWNINGS, SIGNS, PARKING LOT, GENERATOR, | | MECHANICAL/AC/POOL EQUIPMENT, DUMPSTER ENCLOSURE, | | IRRIGATION, LANDSCAPE, AND DRIVEWAY. PLEASE CONFIRM | | THAT THIS IS UNDERSTOOD. | | 3. PROVIDE A PRODUCT APPROVAL FOR THE GARAGE DOOR TO BE | | USED. | | 4. THE PLANS SHOW A BARREL TILE TO BE USED. A PRODUCT | | APPROVAL FOR S-TILE WAS SUBMITTED WITH THE PERMIT. | | REVISE AND INCLUDE COLOR OF THE TILE TO BE USED. | | 5. THE PLANS ILLUSTRATE A SLIDING GLASS DOOR IN THE | | REAR. A PRODUCT APPROVAL WAS NOT SUBMITTED WITH THE | | PERMIT. PLEASE INCLUDE. | | | | THE FOLLOWING ARE PROPOSED CONDITIONS OF APPROVAL, | | ADDITIONAL CONDITIONS MAY BE ADDED AFTER RESUBMITTAL. | | PLEASE CONFIRM THAT THESE CONDITIONS WILL BE COMPLIED | | WITH. | | | | A. ALL WINDOWS AND DOORS SHALL HAVE CLEAR GLASS OR | | CLEAR GLASS WITH LOW-E COATING. | | B. ALL WINDOWS AND DOORS SHALL HAVE EXTERNAL OGEE | | DIMENSIONAL MUNTINS. | | C. ALL WINDOW FRAMES SHALL BE WHITE OR BRONZE IN COLOR. | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | AARON BORNGRABER | | HISTORIC PRESERVATION PLANNER | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | T: 561-822-1428 | | [email protected] | | |
|
|
|