Plan Review Details - Permit 19080742
Plan Review Stops For Permit 19080742
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-10-05 Cont ID  
Sent By cthroop Date 2019-10-05 Time 13:11 Rev Time 0.00
Received By cthroop Date 2019-10-05 Time 10:38 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-09-16 Cont ID  
Sent By cthroop Date 2019-09-16 Time 15:18 Rev Time 0.00
Received By cthroop Date 2019-09-14 Time 13:13 Sent To  
Notes
2019-09-16 15:25:49BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. INCORRECT CODE REFERENCE ON PLAN PAGE A001. CHANGE
 FROM 2014 5TH ED. TO 2017 6TH ED.
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 2. PROVIDE SOILS REPORT.
 FBC 1803.1 GENERAL.GEOTECHNICAL INVESTIGATIONS SHALL BE
 CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND
 REPORTED IN ACCORDANCE WITH SECTION 1803.6. WHERE
 REQUIRED BY THE BUILDING OFFICIAL OR WHERE GEOTECHNICAL
 INVESTIGATIONS INVOLVE IN-SITU TESTING, LABORATORY
 TESTING OR ENGINEERING CALCULATIONS, SUCH
 INVESTIGATIONS SHALL BE CONDUCTED BY A REGISTERED
 DESIGN PROFESSIONAL.
  
 3. PROVIDE SITE DRAINAGE PLAN.
 FBC R401.3 SITE DRAINAGE
 PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING
 COMPLIANCE WITH FBC R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD.
  
 4. PROVIDE ENERGY SUBMITTAL.
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 5. PROVIDE PRODUCT APPROVALS FOR ALL WINDOWS AND DOORS.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-10-05 Cont ID  
Sent By cthroop Date 2019-10-05 Time 12:06 Rev Time 0.00
Received By cthroop Date 2019-10-04 Time 06:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-09-05 Cont ID  
Sent By fgiaquin Date 2019-09-05 Time 07:12 Rev Time 0.00
Received By fgiaquin Date 2019-08-30 Time 06:41 Sent To  
Notes
2019-09-05 07:12:39ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PLANS DID NOT UPLOAD PROPERLY, THEY ARE BLURRY AND
 NOT READABLE. PLEASE SEE REQUIREMENTS FOR PLANS
 SUBMISSIONS BELOW:
  
  
 THE SUBMITTED FLOOR PLAN IS UNACCEPTABLE. PLEASE REVIEW
 THE FOLLOWING SECTIONS FROM THE WEST PALM BEACH
 AMENDMENTS TO THE FBC:
  
 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS
 SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING
 OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT
 CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF
 THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL
 CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT
 LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED
 BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND
 SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM
 OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS,
 WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE
 TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC,
 AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE
 OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS
 EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC
 INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS
 AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE
 OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO
 SECTION 107.3.5).
  
 107.2.1.3 QUALITY OF BUILDING PLANS. BUILDING PLANS
 SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON
 SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM.
 THE BUILDING OFFICIAL MAY ESTABLISH THROUGH
 DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS AND
 SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS
 RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH
 THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR
 OTHER ITEMS RELATED TO RECORDS MANAGEMENT. ELECTRONIC
 MEDIA MUST BE COMPATIBLE WITH THE ARCHIVE REQUIREMENTS
 OF FLORIDA STATUTES.
  
  
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2019-10-01 Cont ID  
Sent By jesmith Date 2019-10-01 Time 15:52 Rev Time 0.00
Received By jesmith Date 2019-10-01 Time 15:49 Sent To  
Notes
2019-10-01 15:52:01GAS PROVISO
 1. PER WPB FBC 107.2.1 AND WPB FBC 107.3.4.1, PROVIDE
 AS A DEFERRED SUBMITTAL, THE MANUFACTURER?S DATA
 SHEETS/SPECIFICATION/INSTALLATION GUIDE FOR ALL GAS
 EQUIPMENT AND REGULATORS. THE DOCUMENTS SHALL BE
 SUBMITTED, APPROVED AND ON SITE PRIOR TO FINAL
 INSPECTION. PROCEED AT YOUR OWN RISK.
 2. LOCATION OF POOL HEATER ON PLAN SHEET A100 WAS
 REQUESTED BUT NOT ADDRESSED. IT IS UNCLEAR AS TO HOW
 THE ENGINEER WAS ABLE TO DETERMINE DISTANCE FROM METER
 TO THE POOL HEATER IN ORDER TO CALCULATE PIPE SIZES.
 INSPECTOR TO VERIFY DISTANCE ON ROUGH AND FINAL
 INSPECTION. PROCEED AT YOUR OWN RISK
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-09-16 Cont ID  
Sent By jesmith Date 2019-09-16 Time 13:14 Rev Time 0.00
Received By jesmith Date 2019-09-10 Time 16:00 Sent To  
Notes
2019-09-16 13:14:52CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 58 = LIQUIFIED PETROLEUM GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 NFPA 99 = HEALTH CARE FACILITIES CODE
 NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
 GAS COMMENTS: DENIED
  
 1. PLEASE NOTE THAT REQUESTS HAVE BEEN MADE FOR CHANGES
 TO ARCHITECTURAL DRAWINGS AS WELL AS MEP. THESE
 REQUESTS MUST BE SATISFIED PRIOR TO GAS PERMIT
 APPROVAL.
 2. PER WPB FBC 107.2.1, PROVIDE ON ARCH PLAN SHEET
 A001, THE LOCATIONS OF THE GAS METER, THE GENERATOR AND
 THE POOL HEATER.
 3. PER WPB FBC 107.2.1, PROVIDE ON ARCH PLAN SHEET A100
 AND ON PLAN SHEET P2.1 AN ACCESS PANEL (INCLUDE
 DIMENSIONS OF PANEL) TO ACCOMMODATE THE ABOVE CEILING
 REGULATOR SERVING THE FIREPLACE IN ACCORDANCE WITH FBC
 FG 410.1.
 4. PER WPB FBC 107.2.1, PROVIDE A DETAIL FOR SLEEVED
 AND VENTED PE PIPE INSTALLED BELOW A HARD SURFACE.
 ADDITIONALLY, WHEN LANDSCAPE/HARDSCAPE DRAWINGS ARE
 SUBMITTED, PER WPB FBC 107.2.1, LOCATIONS OF SLEEVED
 AND VENTED PIPE SECTIONS SHALL BE INDICATED.
 5. RE: PLAN SHEET P0.3; GAS RISER ISOMETRIC. FIREPLACE
 (40,000 BTUH) IS SHOWN AT THE LOCATION THAT INDICATES A
 POOL HEATER (400,000 BTUH) ON PLAN SHEET P2.1. PER WPB
 FBC 107.2.1, PLEASE CLARIFY.
 6. RE: PLAN SHEET P0.3; GAS RISER ISOMETRIC. PER WPB
 FBC 107.2.1, CLEARLY SHOW ON THE ISOMETRIC DRAWING THE
 LENGTH OF ALL CUT SECTIONS OF PIPE IN ACCORDANCE WITH
 FBC FG SECS. 402.4.1, 402.4.2. OR FBC RES SEC.
 G2413.4.1, G2413.4.2.
 7. PER WPB FBC 107.2.1, PLEASE NOTE IN THE CHART ON
 P0.3 INDICATING SIZING TABLES AND TOTAL GAS CONSUMPTION
 THE DISTANCE FROM THE POINT OF DELIVERY, (GAS METER /
 REGULATOR) TO THE MOST REMOTE OUTLET IN THE BUILDING
 AND / OR SYSTEM FOR EACH PRESSURE SYSTEM (2 PSI/0.5
 PSI) IN ACCORDANCE WITH FBC FG SEC.402.4.1, 402.4.2, OR
 FBC RES SEC. G 2413.4.1, G2413.4.2.
 8. PER WPB FBC 107.2.1, PLEASE NOTE IN THE CHART ON
 P0.3 INDICATING SIZING TABLES AND TOTAL GAS CONSUMPTION
 THE TYPE OF GAS (LP OR NATURAL). IT IS ASSUMED TO BE NG
 DUE TO NOTE ON GAS ISOMETRIC PERTAINING TO NATURAL GAS
 CONNECTION BUT NEEDS TO BE STATED.
 9. PER WPB FBC 107.2.1, SUBMIT MANUFACTURER?S
 SPECIFICATION SHEETS / INSTALLATION MANUAL FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54,
 NFPA 58, AND FBC FG SEC. 402.2, AND 301.3 OR 2017 FBC
 RES SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED AND
 LABELED.
 10. PER WPB FBC 107.2.1, SUBMIT MANUFACTURER?S
 SPECIFICATIONS FOR THE PRESSURE REGULATORS. REGULATORS
 INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE
 APPROVED FOR OUTDOOR INSTALLATION IN ACCORDANCE WITH
 FBC FG SEC.410.1, FBC RES SEC. G2421.1. RE: FBC FG
 410.3; INDICATE ON SUBMITTALS FOR INDOORS THE TYPE OF
 VENT ELIMINATOR IS TO BE USED OR PROVIDE ON THE PLANS,
 VENT PIPING (MATERIAL TYPE, SIZE AND ROUTING) TO THE
 EXTERIOR WITH DETAIL OF EXTERIOR TERMINATION IN
 ACCORDANCE WITH FBC FG IN ACCORDANCE WITH FBC FG SECS.
 502 THRU 505 OR FBC RES SEC.G2426 THROUGH G2439.
 11. PER WPB FBC 107.2.1, IN ADDITION TO THE COMBUSTION
 AIR CALCULATIONS PROVIDED FOR THE DRYER ON PLAN SHEET
 M0-2, SUBMIT COMBUSTION AIR CALCULATIONS FOR THE
 ADDITIONAL INDOOR GAS APPLIANCES. WHERE COMBUSTION AIR
 IS PROVIDED BY THE BUILDING?S MECHANICAL VENTILATION
 SYSTEM, THE SYSTEM SHALL PROVIDE THE SPECIFIED
 COMBUSTION AIR RATE IN ADDITION TO THE REQUIRED
 VENTILATION AIR IN ACCORDANCE WITH FBC FG SEC.304.9.3
 OR FBC RES G2407.9.3.
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19080742 125 ALHAMBRA PL
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-10-05 Cont ID  
Sent By cthroop Date 2019-10-05 Time 13:17 Rev Time 0.00
Received By cthroop Date 2019-09-26 Time 07:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-09-17 Cont ID  
Sent By cpuell Date 2019-09-17 Time 10:40 Rev Time 0.00
Received By cpuell Date 2019-08-23 Time 10:32 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status P Date 2019-10-08 Cont ID  
Sent By cthroop Date 2019-10-08 Time 10:13 Rev Time 0.00
Received By lmarchan Date 2019-09-14 Time 13:13 Sent To  
Notes
2019-10-07 11:43:3210/7/19 EMAILED IMPACT FEE TO STAMP THE PLANS. LEM
2019-09-14 14:31:23MU-2019-025282. CT

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-10-05 Cont ID  
Sent By cthroop Date 2019-10-05 Time 13:15 Rev Time 0.00
Received By cthroop Date 2019-10-05 Time 13:11 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-09-16 Cont ID  
Sent By cthroop Date 2019-09-16 Time 15:30 Rev Time 0.00
Received By cthroop Date 2019-09-14 Time 13:13 Sent To  
Notes
2019-09-16 15:32:25MECHANICAL PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE AN ENERGY SUBMITTAL. INCLUDE MANUAL J
 CALCULATIONS.
 FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3
 STORIES.
  
 FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
 (MANDATORY).
 THE BUILDING OFFICIAL SHALL REQUIRE THAT AN ENERGY
 PERFORMANCE LEVEL (EPL) DISPLAY CARD BE COMPLETED AND
 CERTIFIED BY THE BUILDER TO BE ACCURATE AND CORRECT
 BEFORE FINAL APPROVAL OF THE BUILDING FOR OCCUPANCY.
 FLORIDA LAW [SECTION 553.9085, FLORIDA STATUTES)]
 REQUIRES THE EPL DISPLAY CARD TO BE INCLUDED AS AN
 ADDENDUM TO EACH SALES CONTRACT FOR BOTH PRESOLD AND
 NONPRESOLD RESIDENTIAL BUILDINGS. THE EPL DISPLAY CARD
 CONTAINS INFORMATION INDICATING THE ENERGY PERFORMANCE
 LEVEL AND EFFICIENCIES OF COMPONENTS INSTALLED IN A
 DWELLING UNIT. THE BUILDING OFFICIAL SHALL VERIFY THAT
 THE EPL DISPLAY CARD COMPLETED AND SIGNED BY THE
 BUILDER ACCURATELY REFLECTS THE PLANS AND
 SPECIFICATIONS SUBMITTED TO DEMONSTRATE CODE COMPLIANCE
 FOR THE BUILDING. A COPY OF THE EPL DISPLAY CARD CAN BE
 FOUND IN APPENDIX C.
  
  
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-10-01 Cont ID  
Sent By jesmith Date 2019-10-01 Time 15:11 Rev Time 0.00
Received By jesmith Date 2019-10-01 Time 14:42 Sent To  
Notes
2019-10-01 15:11:41PLUMBING COMMENTS: APPROVED W/PROVISO
  
 1. ARCHITECT SHALL PROVIDE AS A REVISION A DETAIL OF
 THE FLAT ROOF CLEARLY SHOWING THE PERIMETER DOES NOT
 EXTEND ABOVE THE ROOF AS HE STATED WAS STATED IN
 RESPONSE TO PLUMBING COMMENTS DATED 9/10/19. PLAN SHEET
 A-300 DOES NOT CLEARLY SHOW THIS TO BE THE CASE. PER
 FBC PL 1108.1, SECONDARY DRAINS ARE REQUIRED WHERE ROOF
 PERIMETER CONSTRUCTION ALLOWS WATER TO BE ENTRAPPED IF
 THE PRIMARY DRAIN(S) ALLOW BUILD UP IN ANY MANNER. THE
 DOCUMENT(S) SHALL BE SUBMITTED, APPROVED AND ON SITE
 PRIOR TO FINAL INSPECTION. PROCEED AT YOUR OWN RISK.
 2. ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-09-10 Cont ID  
Sent By jesmith Date 2019-09-10 Time 15:59 Rev Time 0.00
Received By jesmith Date 2019-09-10 Time 15:57 Sent To  
Notes
2019-09-10 15:59:36CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 54 = NATIONAL FUEL GAS CODE
 NFPA 58 = LIQUIFIED PETROLEUM GAS CODE
 NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE
 PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017
 NFPA 99 = HEALTH CARE FACILITIES CODE
 NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 1ST REVIEW
 PLUMBING COMMEMTS: DENIED
 1. FBC RES P2601.1 SCOPE.
 THE PROVISIONS OF THIS CHAPTER SHALL GOVERN THE
 INSTALLATION OF PLUMBING NOT SPECIFICALLY COVERED IN
 OTHER CHAPTERS APPLICABLE TO PLUMBING SYSTEMS. THE
 INSTALLATION OF PLUMBING, APPLIANCES, EQUIPMENT AND
 SYSTEMS NOT ADDRESSED BY THIS CODE SHALL COMPLY WITH
 THE APPLICABLE PROVISIONS OF THE FLORIDA BUILDING CODE,
 PLUMBING.
 A. FBC PL 1108.1 SECONDARY (EMERGENCY OVERFLOW) DRAINS
 OR SCUPPERS.
 WHERE ROOF DRAINS ARE REQUIRED, SECONDARY (EMERGENCY
 OVERFLOW) ROOF DRAINS OR SCUPPERS SHALL BE PROVIDED
 WHERE THE ROOF PERIMETER CONSTRUCTION EXTENDS ABOVE THE
 ROOF IN SUCH A MANNER THAT WATER WILL BE ENTRAPPED IF
 THE PRIMARY DRAINS ALLOW BUILDUP FOR ANY REASON. WHERE
 PRIMARY AND SECONDARY ROOF DRAINS ARE MANUFACTURED AS A
 SINGLE ASSEMBLY, THE INLET AND OUTLET FOR EACH DRAIN
 SHALL BE INDEPENDENT.
 B. FBC PL 802.3 WASTE RECEPTOR FOR ICEMAKER DISCHARGE
 SHALL BE READILY ACCESSIBLE
 2. WPB FBC 107.2.1 VALID DIGITAL SIGNATURE OF DESIGNER
 IS REQUIRED.
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
 AS THE PLANS ARE NOT SIGNED AND SEALED BY A
 PROFESSIONAL ENGINEER OR ARCHITECT, THE PLUMBING PLAN
 SHALL BEAR THE PRINTED NAME AND SIGNATURE OF THE
 DESIGNER PER WPB FBC 107.2.1.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19080742 125 ALHAMBRA PL
  
  
  
  
  
  
  
  
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2019-10-05 Cont ID  
Sent By cthroop Date 2019-10-05 Time 13:15 Rev Time 0.00
Received By cthroop Date 2019-10-05 Time 13:16 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2019-09-16 Cont ID  
Sent By cthroop Date 2019-09-16 Time 15:25 Rev Time 0.00
Received By cthroop Date 2019-09-14 Time 13:13 Sent To  
Notes
2019-09-16 15:28:56BUILDING PLAN REVIEW - ROOFING
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ROOFING SUB-PERMIT REQUIRED.
 PERMITS
 105.1 REQUIRED.
  
 2. PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOFING
 SYSTEM COMPONENTS.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-10-05 Cont ID  
Sent By cthroop Date 2019-10-05 Time 13:16 Rev Time 0.00
Received By cthroop Date 2019-10-05 Time 13:16 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-09-14 Cont ID  
Sent By cthroop Date 2019-09-14 Time 14:28 Rev Time 0.00
Received By cthroop Date 2019-09-14 Time 13:13 Sent To  
Notes
2019-09-14 14:30:26BUILDING PLAN REVIEW - SIGNATURE AND SEAL
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NO VALID DIGITAL SIGNATURES AND SEALS.
  
 HARD COPIES OF ALL PLAN PAGES REQUIRED AT PERMIT.
  
  
2019-08-14 14:59:558/14/19 HARD COPIES LOCATED IN LIBRARY. LEM

Review Stop Z ZONING
Rev No 2 Status P Date 2019-10-04 Cont ID  
Sent By rfalcone Date 2019-10-04 Time 10:13 Rev Time 0.00
Received By rfalcone Date 2019-10-04 Time 10:13 Sent To I
Notes
2019-10-04 10:14:5110/4/19
  
 ******** ZONING PROVISO ********
  
 PRIOR TO ZONING APPROVAL AND ISSUANCE OF A CERTIFICATE
 OF OCCUPANCY, ONE OF THE FOLLOWING CONDITIONS SHALL BE
 ADDRESSED:
 1. A LANDSCAPE PERMIT, WHICH INCLUDES A LANDSCAPE PLAN,
 SHALL BE SUBMITTED TO THE BUILDING DIVISION FOR REVIEW.
 2. THE LANDSCAPE MATERIAL SHOWN ON THE APPROVED
 LANDSCAPE PERMIT SHALL BE INSTALLED AND PASS A FINAL
 LANDSCAPE INSPECTION.
  
  

Review Stop Z ZONING
Rev No 1 Status F Date 2019-09-17 Cont ID  
Sent By rfalcone Date 2019-09-17 Time 08:23 Rev Time 0.00
Received By rfalcone Date 2019-09-17 Time 08:23 Sent To I
Notes
2019-09-17 08:26:0709/17/19 FAILED.
  
 PURSUANT ZLDR SEC. 94-72(A)(3), THE MAXIMUM BUILDING
 HEIGHT IN 30 FEET. PLEASE REVISE THE HEIGHT OF THE
 STRUCTURE TO CONFORM WITH THE REQUIREMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  