Plan Review Details - Permit 19080742
Plan Review Stops For Permit 19080742 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-10-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-10-05 |
Time |
13:11 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-10-05 |
Time |
10:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-09-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-16 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-14 |
Time |
13:13 |
Sent To |
|
|
Notes |
2019-09-16 15:25:49 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. INCORRECT CODE REFERENCE ON PLAN PAGE A001. CHANGE | | FROM 2014 5TH ED. TO 2017 6TH ED. | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | 2. PROVIDE SOILS REPORT. | | FBC 1803.1 GENERAL.GEOTECHNICAL INVESTIGATIONS SHALL BE | | CONDUCTED IN ACCORDANCE WITH SECTION 1803.2 AND | | REPORTED IN ACCORDANCE WITH SECTION 1803.6. WHERE | | REQUIRED BY THE BUILDING OFFICIAL OR WHERE GEOTECHNICAL | | INVESTIGATIONS INVOLVE IN-SITU TESTING, LABORATORY | | TESTING OR ENGINEERING CALCULATIONS, SUCH | | INVESTIGATIONS SHALL BE CONDUCTED BY A REGISTERED | | DESIGN PROFESSIONAL. | | | | 3. PROVIDE SITE DRAINAGE PLAN. | | FBC R401.3 SITE DRAINAGE | | PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING | | COMPLIANCE WITH FBC R401.3 DRAINAGE. | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | DOES NOT CREATE A HAZARD. | | | | 4. PROVIDE ENERGY SUBMITTAL. | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | | | 5. PROVIDE PRODUCT APPROVALS FOR ALL WINDOWS AND DOORS. | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE WINDOW AND DOOR SUBMITTALS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2019-10-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-10-05 |
Time |
12:06 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-10-04 |
Time |
06:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-09-05 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2019-09-05 |
Time |
07:12 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2019-08-30 |
Time |
06:41 |
Sent To |
|
|
Notes |
2019-09-05 07:12:39 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PLANS DID NOT UPLOAD PROPERLY, THEY ARE BLURRY AND | | NOT READABLE. PLEASE SEE REQUIREMENTS FOR PLANS | | SUBMISSIONS BELOW: | | | | | | THE SUBMITTED FLOOR PLAN IS UNACCEPTABLE. PLEASE REVIEW | | THE FOLLOWING SECTIONS FROM THE WEST PALM BEACH | | AMENDMENTS TO THE FBC: | | | | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. ELECTRONIC MEDIA DOCUMENTS | | SHALL BE SUBMITTED WHEN APPROVED BY THE BUILDING | | OFFICIAL. CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT | | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED | | BY THE BUILDING OFFICIAL. SUCH DRAWINGS AND | | SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE FORM | | OF NOTES OR OTHERWISE, AS TO THE QUALITY OF MATERIALS, | | WHERE QUALITY IS ESSENTIAL TO CONFORMITY WITH THE | | TECHNICAL CODES. SUCH INFORMATION SHALL BE SPECIFIC, | | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE | | OR IN PART, NOR SHALL THE TERM "LEGAL" OR ITS | | EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC | | INFORMATION. ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5). | | | | 107.2.1.3 QUALITY OF BUILDING PLANS. BUILDING PLANS | | SHALL BE DRAWN TO A MINIMUM 1/8 INCH SCALE UPON | | SUBSTANTIAL PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. | | THE BUILDING OFFICIAL MAY ESTABLISH THROUGH | | DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS AND | | SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO ITS | | RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE SUCH | | THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, OR | | OTHER ITEMS RELATED TO RECORDS MANAGEMENT. ELECTRONIC | | MEDIA MUST BE COMPATIBLE WITH THE ARCHIVE REQUIREMENTS | | OF FLORIDA STATUTES. | | | | | | | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-657-1653 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2019-10-01 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2019-10-01 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2019-10-01 |
Time |
15:49 |
Sent To |
|
|
Notes |
2019-10-01 15:52:01 | GAS PROVISO | | 1. PER WPB FBC 107.2.1 AND WPB FBC 107.3.4.1, PROVIDE | | AS A DEFERRED SUBMITTAL, THE MANUFACTURER?S DATA | | SHEETS/SPECIFICATION/INSTALLATION GUIDE FOR ALL GAS | | EQUIPMENT AND REGULATORS. THE DOCUMENTS SHALL BE | | SUBMITTED, APPROVED AND ON SITE PRIOR TO FINAL | | INSPECTION. PROCEED AT YOUR OWN RISK. | | 2. LOCATION OF POOL HEATER ON PLAN SHEET A100 WAS | | REQUESTED BUT NOT ADDRESSED. IT IS UNCLEAR AS TO HOW | | THE ENGINEER WAS ABLE TO DETERMINE DISTANCE FROM METER | | TO THE POOL HEATER IN ORDER TO CALCULATE PIPE SIZES. | | INSPECTOR TO VERIFY DISTANCE ON ROUGH AND FINAL | | INSPECTION. PROCEED AT YOUR OWN RISK | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2019-09-16 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2019-09-16 |
Time |
13:14 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2019-09-10 |
Time |
16:00 |
Sent To |
|
|
Notes |
2019-09-16 13:14:52 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | MANUAL REVISED 2017 | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | EDITION | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | NFPA 54 = NATIONAL FUEL GAS CODE | | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE | | NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | NFPA 99 = HEALTH CARE FACILITIES CODE | | NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | | | 1ST REVIEW | | GAS COMMENTS: DENIED | | | | 1. PLEASE NOTE THAT REQUESTS HAVE BEEN MADE FOR CHANGES | | TO ARCHITECTURAL DRAWINGS AS WELL AS MEP. THESE | | REQUESTS MUST BE SATISFIED PRIOR TO GAS PERMIT | | APPROVAL. | | 2. PER WPB FBC 107.2.1, PROVIDE ON ARCH PLAN SHEET | | A001, THE LOCATIONS OF THE GAS METER, THE GENERATOR AND | | THE POOL HEATER. | | 3. PER WPB FBC 107.2.1, PROVIDE ON ARCH PLAN SHEET A100 | | AND ON PLAN SHEET P2.1 AN ACCESS PANEL (INCLUDE | | DIMENSIONS OF PANEL) TO ACCOMMODATE THE ABOVE CEILING | | REGULATOR SERVING THE FIREPLACE IN ACCORDANCE WITH FBC | | FG 410.1. | | 4. PER WPB FBC 107.2.1, PROVIDE A DETAIL FOR SLEEVED | | AND VENTED PE PIPE INSTALLED BELOW A HARD SURFACE. | | ADDITIONALLY, WHEN LANDSCAPE/HARDSCAPE DRAWINGS ARE | | SUBMITTED, PER WPB FBC 107.2.1, LOCATIONS OF SLEEVED | | AND VENTED PIPE SECTIONS SHALL BE INDICATED. | | 5. RE: PLAN SHEET P0.3; GAS RISER ISOMETRIC. FIREPLACE | | (40,000 BTUH) IS SHOWN AT THE LOCATION THAT INDICATES A | | POOL HEATER (400,000 BTUH) ON PLAN SHEET P2.1. PER WPB | | FBC 107.2.1, PLEASE CLARIFY. | | 6. RE: PLAN SHEET P0.3; GAS RISER ISOMETRIC. PER WPB | | FBC 107.2.1, CLEARLY SHOW ON THE ISOMETRIC DRAWING THE | | LENGTH OF ALL CUT SECTIONS OF PIPE IN ACCORDANCE WITH | | FBC FG SECS. 402.4.1, 402.4.2. OR FBC RES SEC. | | G2413.4.1, G2413.4.2. | | 7. PER WPB FBC 107.2.1, PLEASE NOTE IN THE CHART ON | | P0.3 INDICATING SIZING TABLES AND TOTAL GAS CONSUMPTION | | THE DISTANCE FROM THE POINT OF DELIVERY, (GAS METER / | | REGULATOR) TO THE MOST REMOTE OUTLET IN THE BUILDING | | AND / OR SYSTEM FOR EACH PRESSURE SYSTEM (2 PSI/0.5 | | PSI) IN ACCORDANCE WITH FBC FG SEC.402.4.1, 402.4.2, OR | | FBC RES SEC. G 2413.4.1, G2413.4.2. | | 8. PER WPB FBC 107.2.1, PLEASE NOTE IN THE CHART ON | | P0.3 INDICATING SIZING TABLES AND TOTAL GAS CONSUMPTION | | THE TYPE OF GAS (LP OR NATURAL). IT IS ASSUMED TO BE NG | | DUE TO NOTE ON GAS ISOMETRIC PERTAINING TO NATURAL GAS | | CONNECTION BUT NEEDS TO BE STATED. | | 9. PER WPB FBC 107.2.1, SUBMIT MANUFACTURER?S | | SPECIFICATION SHEETS / INSTALLATION MANUAL FOR ALL GAS | | EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA 54, | | NFPA 58, AND FBC FG SEC. 402.2, AND 301.3 OR 2017 FBC | | RES SEC. G2404.3. GAS APPLIANCES SHALL BE LISTED AND | | LABELED. | | 10. PER WPB FBC 107.2.1, SUBMIT MANUFACTURER?S | | SPECIFICATIONS FOR THE PRESSURE REGULATORS. REGULATORS | | INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE | | APPROVED FOR OUTDOOR INSTALLATION IN ACCORDANCE WITH | | FBC FG SEC.410.1, FBC RES SEC. G2421.1. RE: FBC FG | | 410.3; INDICATE ON SUBMITTALS FOR INDOORS THE TYPE OF | | VENT ELIMINATOR IS TO BE USED OR PROVIDE ON THE PLANS, | | VENT PIPING (MATERIAL TYPE, SIZE AND ROUTING) TO THE | | EXTERIOR WITH DETAIL OF EXTERIOR TERMINATION IN | | ACCORDANCE WITH FBC FG IN ACCORDANCE WITH FBC FG SECS. | | 502 THRU 505 OR FBC RES SEC.G2426 THROUGH G2439. | | 11. PER WPB FBC 107.2.1, IN ADDITION TO THE COMBUSTION | | AIR CALCULATIONS PROVIDED FOR THE DRYER ON PLAN SHEET | | M0-2, SUBMIT COMBUSTION AIR CALCULATIONS FOR THE | | ADDITIONAL INDOOR GAS APPLIANCES. WHERE COMBUSTION AIR | | IS PROVIDED BY THE BUILDING?S MECHANICAL VENTILATION | | SYSTEM, THE SYSTEM SHALL PROVIDE THE SPECIFIED | | COMBUSTION AIR RATE IN ADDITION TO THE REQUIRED | | VENTILATION AIR IN ACCORDANCE WITH FBC FG SEC.304.9.3 | | OR FBC RES G2407.9.3. | | | | | | END OF COMMENTS. | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 | | | | 19080742 125 ALHAMBRA PL | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-10-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-10-05 |
Time |
13:17 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-26 |
Time |
07:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-09-17 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2019-09-17 |
Time |
10:40 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2019-08-23 |
Time |
10:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
P |
Date |
2019-10-08 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-10-08 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-09-14 |
Time |
13:13 |
Sent To |
|
|
Notes |
2019-10-07 11:43:32 | 10/7/19 EMAILED IMPACT FEE TO STAMP THE PLANS. LEM | 2019-09-14 14:31:23 | MU-2019-025282. CT |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2019-10-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-10-05 |
Time |
13:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-10-05 |
Time |
13:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2019-09-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-16 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-14 |
Time |
13:13 |
Sent To |
|
|
Notes |
2019-09-16 15:32:25 | MECHANICAL PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE AN ENERGY SUBMITTAL. INCLUDE MANUAL J | | CALCULATIONS. | | FBCE-103.2.1.1 RESIDENTIAL LESS THAN OR EQUAL TO 3 | | STORIES. | | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | | | R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD | | (MANDATORY). | | THE BUILDING OFFICIAL SHALL REQUIRE THAT AN ENERGY | | PERFORMANCE LEVEL (EPL) DISPLAY CARD BE COMPLETED AND | | CERTIFIED BY THE BUILDER TO BE ACCURATE AND CORRECT | | BEFORE FINAL APPROVAL OF THE BUILDING FOR OCCUPANCY. | | FLORIDA LAW [SECTION 553.9085, FLORIDA STATUTES)] | | REQUIRES THE EPL DISPLAY CARD TO BE INCLUDED AS AN | | ADDENDUM TO EACH SALES CONTRACT FOR BOTH PRESOLD AND | | NONPRESOLD RESIDENTIAL BUILDINGS. THE EPL DISPLAY CARD | | CONTAINS INFORMATION INDICATING THE ENERGY PERFORMANCE | | LEVEL AND EFFICIENCIES OF COMPONENTS INSTALLED IN A | | DWELLING UNIT. THE BUILDING OFFICIAL SHALL VERIFY THAT | | THE EPL DISPLAY CARD COMPLETED AND SIGNED BY THE | | BUILDER ACCURATELY REFLECTS THE PLANS AND | | SPECIFICATIONS SUBMITTED TO DEMONSTRATE CODE COMPLIANCE | | FOR THE BUILDING. A COPY OF THE EPL DISPLAY CARD CAN BE | | FOUND IN APPENDIX C. | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2019-10-01 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2019-10-01 |
Time |
15:11 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2019-10-01 |
Time |
14:42 |
Sent To |
|
|
Notes |
2019-10-01 15:11:41 | PLUMBING COMMENTS: APPROVED W/PROVISO | | | | 1. ARCHITECT SHALL PROVIDE AS A REVISION A DETAIL OF | | THE FLAT ROOF CLEARLY SHOWING THE PERIMETER DOES NOT | | EXTEND ABOVE THE ROOF AS HE STATED WAS STATED IN | | RESPONSE TO PLUMBING COMMENTS DATED 9/10/19. PLAN SHEET | | A-300 DOES NOT CLEARLY SHOW THIS TO BE THE CASE. PER | | FBC PL 1108.1, SECONDARY DRAINS ARE REQUIRED WHERE ROOF | | PERIMETER CONSTRUCTION ALLOWS WATER TO BE ENTRAPPED IF | | THE PRIMARY DRAIN(S) ALLOW BUILD UP IN ANY MANNER. THE | | DOCUMENT(S) SHALL BE SUBMITTED, APPROVED AND ON SITE | | PRIOR TO FINAL INSPECTION. PROCEED AT YOUR OWN RISK. | | 2. ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | INSPECTOR'S APPROVAL |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-09-10 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2019-09-10 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2019-09-10 |
Time |
15:57 |
Sent To |
|
|
Notes |
2019-09-10 15:59:36 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | MANUAL REVISED 2017 | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | EDITION | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | NFPA 54 = NATIONAL FUEL GAS CODE | | NFPA 58 = LIQUIFIED PETROLEUM GAS CODE | | NFPA 96 = STANDARD FOR VENTILATION CONTROLAND FIRE | | PROTECTION OF COMMERCIAL COOKING OPERATIONS 2017 | | NFPA 99 = HEALTH CARE FACILITIES CODE | | NFPA 99B = STANDARD FOR HYPERBARIC FACILITIES | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | | | 1ST REVIEW | | PLUMBING COMMEMTS: DENIED | | 1. FBC RES P2601.1 SCOPE. | | THE PROVISIONS OF THIS CHAPTER SHALL GOVERN THE | | INSTALLATION OF PLUMBING NOT SPECIFICALLY COVERED IN | | OTHER CHAPTERS APPLICABLE TO PLUMBING SYSTEMS. THE | | INSTALLATION OF PLUMBING, APPLIANCES, EQUIPMENT AND | | SYSTEMS NOT ADDRESSED BY THIS CODE SHALL COMPLY WITH | | THE APPLICABLE PROVISIONS OF THE FLORIDA BUILDING CODE, | | PLUMBING. | | A. FBC PL 1108.1 SECONDARY (EMERGENCY OVERFLOW) DRAINS | | OR SCUPPERS. | | WHERE ROOF DRAINS ARE REQUIRED, SECONDARY (EMERGENCY | | OVERFLOW) ROOF DRAINS OR SCUPPERS SHALL BE PROVIDED | | WHERE THE ROOF PERIMETER CONSTRUCTION EXTENDS ABOVE THE | | ROOF IN SUCH A MANNER THAT WATER WILL BE ENTRAPPED IF | | THE PRIMARY DRAINS ALLOW BUILDUP FOR ANY REASON. WHERE | | PRIMARY AND SECONDARY ROOF DRAINS ARE MANUFACTURED AS A | | SINGLE ASSEMBLY, THE INLET AND OUTLET FOR EACH DRAIN | | SHALL BE INDEPENDENT. | | B. FBC PL 802.3 WASTE RECEPTOR FOR ICEMAKER DISCHARGE | | SHALL BE READILY ACCESSIBLE | | 2. WPB FBC 107.2.1 VALID DIGITAL SIGNATURE OF DESIGNER | | IS REQUIRED. | | | | | | END OF COMMENTS. | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | AS THE PLANS ARE NOT SIGNED AND SEALED BY A | | PROFESSIONAL ENGINEER OR ARCHITECT, THE PLUMBING PLAN | | SHALL BEAR THE PRINTED NAME AND SIGNATURE OF THE | | DESIGNER PER WPB FBC 107.2.1. | | | | | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 | | | | 19080742 125 ALHAMBRA PL | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2019-10-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-10-05 |
Time |
13:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-10-05 |
Time |
13:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2019-09-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-16 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-14 |
Time |
13:13 |
Sent To |
|
|
Notes |
2019-09-16 15:28:56 | BUILDING PLAN REVIEW - ROOFING | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. ROOFING SUB-PERMIT REQUIRED. | | PERMITS | | 105.1 REQUIRED. | | | | 2. PROVIDE PRODUCT APPROVALS FOR PROPOSED ROOFING | | SYSTEM COMPONENTS. | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2019-10-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-10-05 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-10-05 |
Time |
13:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2019-09-14 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-14 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-14 |
Time |
13:13 |
Sent To |
|
|
Notes |
2019-09-14 14:30:26 | BUILDING PLAN REVIEW - SIGNATURE AND SEAL | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | NO VALID DIGITAL SIGNATURES AND SEALS. | | | | HARD COPIES OF ALL PLAN PAGES REQUIRED AT PERMIT. | | | | | 2019-08-14 14:59:55 | 8/14/19 HARD COPIES LOCATED IN LIBRARY. LEM |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2019-10-04 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2019-10-04 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2019-10-04 |
Time |
10:13 |
Sent To |
I |
|
Notes |
2019-10-04 10:14:51 | 10/4/19 | | | | ******** ZONING PROVISO ******** | | | | PRIOR TO ZONING APPROVAL AND ISSUANCE OF A CERTIFICATE | | OF OCCUPANCY, ONE OF THE FOLLOWING CONDITIONS SHALL BE | | ADDRESSED: | | 1. A LANDSCAPE PERMIT, WHICH INCLUDES A LANDSCAPE PLAN, | | SHALL BE SUBMITTED TO THE BUILDING DIVISION FOR REVIEW. | | 2. THE LANDSCAPE MATERIAL SHOWN ON THE APPROVED | | LANDSCAPE PERMIT SHALL BE INSTALLED AND PASS A FINAL | | LANDSCAPE INSPECTION. | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2019-09-17 |
|
|
Cont ID |
|
Sent By |
rfalcone |
Date |
2019-09-17 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
rfalcone |
Date |
2019-09-17 |
Time |
08:23 |
Sent To |
I |
|
Notes |
2019-09-17 08:26:07 | 09/17/19 FAILED. | | | | PURSUANT ZLDR SEC. 94-72(A)(3), THE MAXIMUM BUILDING | | HEIGHT IN 30 FEET. PLEASE REVISE THE HEIGHT OF THE | | STRUCTURE TO CONFORM WITH THE REQUIREMENTS. | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | PLANNING DEPARTMENT WEBSITE AT | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | CONTACT ME. | | | | RACHEL FALCONE, ASSOCIATE PLANNER | | DEVELOPMENT SERVICES DEPARTMENT | | TEL: (561) 822-1442 | | E-MAIL: [email protected] | | |
|
|
|