Plan Review Stops For Permit 19080683 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2020-01-16 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2020-01-16 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2020-01-16 |
Time |
07:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-12-05 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-12-05 |
Time |
12:29 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-12-04 |
Time |
15:07 |
Sent To |
|
|
Notes |
2019-12-05 12:29:53 | BUILDING REVIEW COMMENTS: | | | | W.P.B. PERMIT: 19080683 | | REVIEWED: DECEMBER 5, 2019 | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER PX4191 | | [email protected] | | 561-805-6718 | | | | FLORIDA BUILDING CODE,6TH EDITION (2017) | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | BELOW) | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | BUILDING-PERMIT-FORMS | | FBC[B] = FBC BUILDING | | FBC[A] = FBC ACCESSIBILITY | | FBC[E] = FBC ENERGY CONSERVATION | | | | 1) 107.3.5 FBC[AMENDED]PLEASE PROVIDE A PLAN VIEW TO | | SHOW THE SIZE OF THE ROOM, SIZE OF GENERATOR AND SPACE | | PROVIDED AROUND THE UNIT. ALSO ACCOUNT FOR ACCESS DOOR | | SWINGS TO ALLOW TO FULLY OPEN. | | 2) PROVIDE DETAILS OF HOW THE UNIT CONNECTS TO FLOOR | | AND HOW PENETRATIONS FOR AIR DUCTS AND EXHAUST MEET | | CODE REQUIRMENTS. | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2020-01-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-01-18 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-01-21 |
Time |
09:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2020-01-16 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2020-01-16 |
Time |
07:23 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2020-01-16 |
Time |
07:23 |
Sent To |
|
|
Notes |
2020-01-16 07:23:12 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. CORRECTED, VALUE ACCEPTED. | | 2. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. WPB | | FBC 107.2.1, 107.3.5; FS 471, 481 (THE COMMENT RESPONSE | | REFERS TO THE ORIGINAL PERMIT 17110874. DURING THE | | FIRST PLAN REVIEW, THE VERY FIRST COMMENT NOTED STATED | | THE FOLLOWING: "FIRE ALARM, LOW VOLTAGE SYSTEMS, DAS, | | LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | SYSTEMS, WALK IN COOLERS, SIGNS, SITE LIGHTING, AND | | SWIMMING POOLS (WHERE APPLICABLE) ARE NOT INCLUDED IN | | THE SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE | | INDICATING THE REQUIRED SEPARATE PERMITS AND PLAN | | SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. WPB FBC | | 105.1, 107.2.1" A NOTE WAS ADDED TO THE PLAN TO THIS | | EFFECT. PLAN REVIEW FOR THE GENERATOR WAS NOT DONE ON | | THE ORIGINAL REVIEW AND MUST BE COMPLETED NOW. | | ADDITIONALLY, AS A MATTER OF PUBLIC RECORD, PLANS MUST | | BE INCLUDED. PROVIDE ALL PLAN SHEETS THAT RELATE TO | | GENERATOR INSTALLATION FOR REVIEW. THE SPEC SHEET FOR | | THE GENERATOR IS NOT CONSIDERED A PLAN.) | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, PROVIDE A RESPONSE LETTER ADDRESSING EACH | | ITEM ALONG WITH THE CITY RESUBMITTAL FORM. | | ADDITIONALLY, INSERT CORRECTED PAGES INTO THE ORIGINAL | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | REMAIN IN PACKAGE AND BE MARKED OLD SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-11-13 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-11-13 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-11-13 |
Time |
15:15 |
Sent To |
I |
|
Notes |
2019-11-13 15:18:26 | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY BN, BU, PX | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | 1) VALUE FOR A 250 KW GENSET IS LOW, PLEASE SUBMIT A | | VALUE WHICH WILL REFLECT THE ACTUAL VALUE OF THE | | GENERATOR INSTALLATION. | | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | 2) NO ELECTRICAL DIAGRAMS HAVE BEEN SUBMITTED. | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2020-01-17 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-01-17 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-01-17 |
Time |
08:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2019-11-06 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-11-06 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-11-06 |
Time |
09:10 |
Sent To |
|
|
Notes |
2019-11-06 16:09:28 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE ARE NO INDICATIONS OF THE GENERATOR EXHAUST | | SYSTEM. | | | | PLEASE PROVIDE DETAILS IN COMPLIANCE WITH ALL | | APPLICABLE NFPA 110 AND 37. | | | | 7.10 EXHAUST SYSTEM. | | 7.10.1 THE EXHAUST SYSTEM EQUIPMENT AND INSTALLATION, | | INCLUDING | | PIPING, MUFFLER, AND RELATED ACCESSORIES, SHALL BE IN | | ACCORDANCE WITH NFPA37, STANDARD FOR THE INSTALLATION | | AND USE OF | | STATIONARY COMBUSTION ENGINES AND GAS TURBINES, AND | | OTHER APPLICABLE | | STANDARDS. | | 7.10.2 EXHAUST SYSTEM INSTALLATION SHALL BE GASTIGHT TO | | PREVENT | | EXHAUST GAS FUMES FROM ENTERING INHABITED ROOMS OR | | BUILDINGS | | AND TERMINATE IN SUCH A MANNER THAT TOXIC FUMES CANNOT | | REENTER A BUILDING OR STRUCTURE, PARTICULARLY THROUGH | | WINDOWS, | | AIR VENTILATION INLETS, OR THE ENGINE AIR-INTAKE | | SYSTEM. | | 7.10.3* EXHAUST PIPING SHALL BE CONNECTED TO THE PRIME | | MOVER | | BY MEANS OF A FLEXIBLE CONNECTOR AND SHALL BE | | INDEPENDENTLY | | SUPPORTED THEREAFTER SO THAT NO DAMAGING WEIGHT OR | | STRESS IS | | APPLIED TO THE ENGINE EXHAUST MANIFOLD OR TURBOCHARGER. | | | | | | PLEASE PROVIDE DETAILS. | | | | | | | | 2) THERE ARE NO INDICATIONS OF VENTILATION AIRFLOW. | | | | PER NFPA 110 | | | | 7.7 HEATING, COOLING, AND VENTILATING. | | 7.7.1* WITH THE EPS RUNNING AT RATED LOAD, VENTILATION | | AIRFLOW | | SHALL BE PROVIDED TO LIMIT THE MAXIMUM AIR TEMPERATURE | | IN THE | | EPS ROOM OR THE ENCLOSURE HOUSING THE UNIT TO THE | | MAXIMUM | | AMBIENT AIR TEMPERATURE REQUIRED BY THE EPS | | MANUFACTURER. | | | | 7.7.3 VENTILATION AIR SUPPLY SHALL BE FROM OUTDOORS OR | | FROM A | | SOURCE OUTSIDE THE BUILDING BY AN EXTERIOR WALL OPENING | | OR | | FROM A SOURCE OUTSIDE THE BUILDING BY A 2-HOUR | | FIRE-RATED AIR | | TRANSFER SYSTEM. | | 7.7.4 VENTILATION AIR SHALL BE PROVIDED TO SUPPLY AND | | DISCHARGE | | COOLING AIR FOR RADIATOR COOLING OF THE EPS WHEN | | RUNNING | | AT RATED LOAD. | | 7.7.4.1 VENTILATION AIR SUPPLY AND DISCHARGE FOR | | RADIATORCOOLED | | EPS SHALL HAVE A MAXIMUM STATIC RESTRICTION OF 125 PA | | (0.5 IN. OF WATER COLUMN) IN THE DISCHARGE DUCT AT THE | | RADIATOR | | OUTLET. | | 7.7.4.2 RADIATOR AIR DISCHARGE SHALL BE DUCTED OUTDOORS | | OR TO | | AN EXTERIOR OPENING BY A 2-HOUR RATED AIR TRANSFER | | SYSTEM. | | | | PLEASE PROVIDE DETAILS | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2020-01-15 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2020-01-15 |
Time |
18:44 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2020-01-15 |
Time |
14:38 |
Sent To |
|
|
Notes |
2020-01-15 18:46:40 | APPROVED UNDER MASTER 17110874 | | | | GAS PROVISO UNDER MASTER: | | | | 4. THE INTAKE AND EXHAUST FOR THE BOILERS AND GENERATOR | | ARE LOCATED DOWN AT THE BOTTOM OF A SHAFT OR PIT HOW | | WILL THE EXHAUST BE KEPT FROM BUILDING UP IF THERE IS | | NO VENTILATION OF THE AREA SOME DOCUMENTATION FROM THE | | MANUFACTURE WILL BE REQUIRED STATING THAT THIS | | CONFIGURATION WILL ALLOW THE EQUIPMENT TO FUNCTION | | PROPERLY. PER WPB AMEND TO FBC 107.2.1 THE RESPONSE | | LETTER IS NOT A CONSTRUCTION DOCUMENT PLEASE INCLUDE | | REQUESTED DOCUMENT A SIGNED AND SEALED LETTER FROM THE | | MANUFACTURES AND THE ENGINEER. STATING THAT THIS PIPING | | LAYOUT WILL ALLOW BOTH THE GENERATOR AND THE BOILERS TO | | FUNCTION PROPERLY SIMULTANEOUSLY. | | | | PREVIOUS COMMENT NOT COMPLIED 5. SHT. P-407 PLEASE SHOW | | ON THE PLAN THE MIN DISTANCE BETWEEN THE INTAKE AND | | EXHAUST. . PER WPB AMEND TO FBC 107.2.1 THE RESPONSE | | LETTER IS NOT A CONSTRUCTION DOCUMENT PLEASE INCLUDE | | REQUESTED DIMENSIONS ON THE PLAN. | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2019-11-12 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2019-11-12 |
Time |
06:49 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2019-11-12 |
Time |
06:45 |
Sent To |
|
|
Notes |
2019-11-12 06:49:16 | 11/12/2019 2ND GAS REVIEW**DENIED** WITH COMMENTS NOTE | | - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS TIME | | AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE GENERATED | | UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | 1- THE BTU LOAD OF THE EXISTING GAS SYSTEM MUST BE | | ADDED INTO THE TOTAL BTU LOAD ON THE SYSTEM TO ENSURE | | THE EXISTING SYSTEM IS PROPERLY SIZED. IF UNDERSIZED, | | THE EXISTING SYSTEM MUST BE REDONE TO ENSURE A SAFE | | OPERATING SYSTEM. 2017 FBC FUEL GAS SEC. 401.4, 401.8, | | 402.1, 402.2, 402.3 OR 2017 FBC FUEL GAS SECS.G2412.4, | | G2412.8, G2413.1, G2413.2, G2413.3. | | | | 2-GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE. AT | | THIS TIME. WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | 3-WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | 4- THE INFORMATION PROVIDED STATES THAT THE | | MANUFACTURE" OFFERS" A UL 2200. PROVIDE A COPY OF THE | | UL 2200 LISTING FOR THE GENERATOR | | | | ATELYO BELISLE | | PLUMBING INSPECTOR / | | PLUMBING PLANS EXAMINER | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6695 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2019-09-09 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2019-09-09 |
Time |
06:49 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2019-09-05 |
Time |
06:23 |
Sent To |
|
|
Notes |
2019-09-09 06:50:21 | 9/9/2019 1ST GAS REVIEW**DENIED** WITH COMMENTS NOTE - | | A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS TIME | | AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE GENERATED | | UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | 1-SUBMIT 2 COPIES OF THE GENERATORS MANUFACTURES | | INSTALLATION WPB AMENDMENTS TO THE FBC SEC. 107.2.1. | | INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | 2-PROVIDE COPY OF THE UL LISTING FOR THE GENERATOR, IT | | SHALL MEET UL 2200 | | | | 3-THE BTU LOAD OF THE EXISTING GAS SYSTEM MUST BE ADDED | | INTO THE TOTAL BTU LOAD ON THE SYSTEM TO ENSURE THE | | EXISTING SYSTEM IS PROPERLY SIZED. IF UNDERSIZED, THE | | EXISTING SYSTEM MUST BE REDONE TO ENSURE A SAFE | | OPERATING SYSTEM. 2017 FBC FUEL GAS SEC. 401.4, 401.8, | | 402.1, 402.2, 402.3 OR 2017 FBC FUEL GAS SECS.G2412.4, | | G2412.8, G2413.1, G2413.2, G2413.3. | | | | 4-GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE. AT | | THIS TIME. WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | 5-WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | ATELYO BELISLE | | PLUMBING INSPECTOR / | | PLUMBING PLANS EXAMINER | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6695 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-01-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2020-01-18 |
Time |
11:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2020-01-14 |
Time |
08:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-12-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-12-13 |
Time |
07:22 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-10-30 |
Time |
08:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-09-11 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2019-09-11 |
Time |
09:37 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-08-14 |
Time |
12:44 |
Sent To |
|
|
Notes |
2019-08-30 11:55:15 | TO LMARCHAN | 2019-08-15 12:44:55 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2020-01-17 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-01-17 |
Time |
12:20 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-01-17 |
Time |
10:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2020-01-16 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2020-01-16 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2020-01-16 |
Time |
08:42 |
Sent To |
|
|
Notes |
2020-01-16 12:15:38 | 2ND REVIEW FBC-2017 MECHANICAL | | PERMIT #19080683 | | 1/16/20 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | NFPA 110-2013 | | NFPA 37-2015 | | NFPA 54-2015 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET M-101: THE GENERATOR SHALL BE INSTALLED AT A | | MINIMUM OF 5' FROM THE EXTERIOR DOOR OPENING. PLEASE | | SHOW THE CLEARANCE DISTANCE ON THE PLAN- SECTION 4.1.4 | | NFPA 37. | | | | 2) SHEET P-102 APPROVED UNDER THE MAIN BUILDING PERMIT | | #17110874 SHOWS A FLOOR DRAIN IN THE CENTER OF THE | | OPEN-ROOFED GENERATOR ENCLOSURE. VERIFY THAT THERE IS | | ADEQUATE SPACE BELOW THE GENERATOR FOR WATER TO DRAIN | | INTO THE FIXTURE. PLEASE REVIEW THE ENCLOSURE | | INSTALLATION DETAILS BY ENGINEERING EXPRESS AND | | DESIGNATE WHICH METHOD WILL BE USED. SECTION 107.2.1 | | WPB. | | | | 3) CONCERNING COMMENT #4D FROM THE 1ST REVIEW PRINTED | | BELOW, THE ENGINEER OF RECORD HAS REQUESTED APPROVAL OF | | THE GENERATOR PERMIT WITH A PROVISO PENDING A LETTER | | FROM FLORIDA PUBLIC UTILITIES. PLEASE NOTE THAT A HOLD | | MAY BE PLACED ON THE CERTIFICATE OF OCCUPANCY UNTIL THE | | DOCUMENT HAS BEEN RECEIVED. | | | | 4D) PLEASE REVIEW SECTION 5.1.1 NFPA 110 AND PROVIDE | | DOCUMENTATION THAT VERIFIES THE LOW PROBABILTY OF GAS | | SERVICE INTERUPTION, OR PROVIDE ON-SITE STORAGE OF AN | | ALTERNATE ENERGY SOURCE. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2019-12-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-12-09 |
Time |
16:02 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-12-09 |
Time |
14:39 |
Sent To |
|
|
Notes |
2019-12-09 16:09:17 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #19080683 | | 12/9/2019 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | NFPA 110-2013 | | NFPA 37-2015 | | NFPA 54-2015 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) REFER TO FIRE REVIEW COMMENTS DATED 11/6/2019 FOR | | THE EPS (GENERATOR) ROOM ENCLOSURE AND ROOM VENTILATION | | REQUIREMENTS AS LISTED UNDER NFPA 110- 2013 STANDARD | | FOR EMERGENCY AND STANDBY POWER SYSTEMS. COMPLY WITH | | THOSE COMMENTS AND THESE ADDITIONAL COMMENTS LISTED | | BELOW. | | | | 2) PLEASE PROVIDE AN ENLARGED DRAWING OF THE EPS ROOM | | THAT INDICATES: | | A) FIRE RESISTANCE RATINGS OF THE WALLS AND CEILING- | | SECTION 7.2.1.1 NFPA 110. | | B) HOW THE GENERATOR WILL BE POSITIONED IN THE ROOM | | WITH CLEARANCES. IT APPEARS BY THE SUBMITTED SITE PLAN | | THAT THERE COULD BE DIFFICULTY IN COMPLYING WITH | | SECTION 7.7.4.2 NFPA 110 WHICH REQUIRES THE GENERATOR | | RADIATOR TO BE DUCTED OUTDOORS OR TO AN EXTERIOR | | OPENING BY A 2-HR RATED AIR TRANSFER SYSTEM. | | C) REQUIRED ROOM VENTILATION AND MAKEUP AIR FOR THE | | EXHAUST- SEE FIRE COMMENTS. | | D) GAS AND EXHAUST PIPING LAYOUTS IN THE ROOM. | | E) HOW COMBUSTION AIR WILL BE PROVIDED- SECTION 304 FBC | | FG. PLEASE SHOW THE MEANS AND METHOD, AND PROVIDE | | CALCULATIONS. | | | | 3) ENGINE EXHAUST PIPING: | | A) SUBMIT MANUFACTURER'S PRODUCT DATA FOR THE EXHAUST | | PIPING. | | B) PROVIDE AN EXHAUST PIPING DRAWING SHOWING THE PIPING | | RUN, PIPING TYPE AND SIZE, AND EXHAUST DISCHARGE | | LOCATION WITH CLEARANCE DISTANCE MEASUREMENTS FROM THE | | TERMINATION TO MECHANICAL AND OPERABLE AIR INLETS INTO | | THE BUILDING, TO GRADE, AND TO PROPERTY LINES. | | C) PROVIDE A BACK PRESSURE CALCULATION. | | | | 4) GAS PIPING: | | A) PROVIDE AN ISOMETRIC DRAWING. | | B) PROVIDE A GAS PIPING LAYOUT DRAWING SHOWING THE | | PIPING RUN FROM THE METER TO THE EPS ROOM. | | C) REFER TO SECTIONS 7.9.6, 7.9.7, & 7.9.9 NFPA 110 AND | | PROVIDE A DETAIL THAT SHOWS THE CORRECT LOCATION FOR | | EPS GAS LINE CONNECTION AND VALVE LABELING AT THE | | UTILTY METER. | | D) PLEASE REVIEW SECTION 5.1.1 NFPA 110 AND PROVIDE | | DOCUMENTATION THAT VERIFIES THE LOW PROBABILTY OF GAS | | SERVICE INTERUPTION, OR PROVIDE ON-SITE STORAGE OF AN | | ALTERNATE ENERGY SOURCE. | | | | 5) DESIGN CRITERIA: PROVIDE A CURRENT LIST OF ALL | | APPLICABLE CODES AND STANDARDS USED IN THE DESIGN OF | | THE EPS PROJECT- SECTION 107.2.1 WPB. | | | | 6) PLEASE CLARIFY WHY WINDLOAD ENGINEERING BY FRANK | | BERNARDO P.E. HAS BEEN SUBMITTED IF THE GENERATOR IS TO | | BE LOCATED IN AN ENCLOSED ROOM INSIDE THE BUILDING- | | SECTION 107.2.1 WPB. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2020-01-15 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2020-01-15 |
Time |
18:46 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2020-01-15 |
Time |
14:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-12-10 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-11-12 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-11-12 |
Time |
08:19 |
Sent To |
|
|
Notes |
2019-12-10 08:20:04 | SEE GAS REVIEW | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2020-01-16 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2020-01-16 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2020-01-16 |
Time |
14:27 |
Sent To |
|
|
Notes |
2020-01-16 14:33:07 | ANY ADDITIONAL SHEETS SUBMITTED WILL NEED DIGITAL | | SIGNATURES. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2019-12-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-12-09 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-12-09 |
Time |
16:57 |
Sent To |
|
|
Notes |
2019-12-09 17:03:37 | | | DIGITAL SIGNATURE REVIEW | | PERMIT #19080863 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE SITE PLAN REQUIRES AN ELECTRONIC SEAL AND | | SIGNATURE BY THE ARCHITECT OF RECORD- FL STATUTE | | 481.221 AND SECTION 61G-16.005 FLORIDA ADMINISTRATIVE | | CODE. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2019-12-10 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2019-12-10 |
Time |
09:12 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2019-12-10 |
Time |
09:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2019-08-30 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2019-08-30 |
Time |
11:54 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2019-08-30 |
Time |
11:54 |
Sent To |
B |
|
Notes |
2019-08-30 11:54:57 | 1. PLEASE PROVIDE A SITE PLAN INDICATING THE LOCATION | | OF THE GENERATOR. | | FOR ADDITIONAL INFORMATION PLEASE CONTACT ANA MARIA | | APONTE AT 561-822-1439. |
|
|