Plan Review Details - Permit 19080654
Plan Review Stops For Permit 19080654
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time  
Received By   Date   Time   Sent To  
Notes
2019-09-05 12:10:19BUILT IN 1985 TEN YEARS AFTER THE BAN ON ASBESTOS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-10-09 Cont ID  
Sent By dbattles Date 2019-10-09 Time 13:28 Rev Time 0.00
Received By dbattles Date 2019-10-09 Time 12:57 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-09-05 Cont ID  
Sent By jwitmer Date 2019-09-05 Time 15:49 Rev Time 0.00
Received By jwitmer Date 2019-09-05 Time 11:46 Sent To  
Notes
2019-09-05 15:31:312017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19080654
 ADD: 515 N. FLAGLER DR. SUITE: 800
 CONT: FINE LINE CONSTRUCTION
 TEL: 561-582-7880
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION.
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: THURS. SEPT. 05/ 2019
 ACTION: PROVISO.
  
 1) SHEET A-5 DETAIL 1 NEW KITCHEN WEST ELEVATION SHOWS
 THE SINK AND COUNTERTOP OF THE BASE CABINET AND AN OPEN
 SHELF 22 INCHES ABOVE THE TOP OF THE BASE CABINET.
 SHEET E2 & E3 BOTH SHOW AN ELECTRICAL CIRCUIT # 18 A
 DEDICATED APPLIANCE CIRCUIT, RECESSED OUTLET IN OPEN
 SHELF ABOVE THE SINK. PLEASE BE AWARE IF THIS APPLIANCE
 CIRCUIT IS TO BE USED FOR A FUTURE MICROWAVE OR SIMILAR
 APPLIANCE THE LOCATION OF THE APPLIANCE MUST MEET THE
 FOLLOWING REQUIREMENTS OR AN EQUIVALENCY. PLEASE REVIEW
 THE 2017 FBC-ACCESSIBILITY CODE SECTIONS:
  
 1A) 308 REACH RANGES. 308.2 FORWARD REACH. / 308.2.1
 UNOBSTRUCTED/ 308.2.2 OBSTRUCTED HIGH REACH.
 308.3 SIDE REACH. / 308.3.1 UNOBSTRUCTED/ 308.3.2
 OBSTRUCTED HIGH REACH.
  
 1B) 309 OPERABLE PARTS. 309.3 HEIGHT. OPERABLE PARTS
 SHALL BE PLACED WITHIN ONE OR MORE OF THE REACH RANGES
 SPECIFIED IN 308. 309.4 OPERATION. OPERABLE PARTS SHALL
 BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT
 GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE
 REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS
 MAXIMUM.
  
 THE NEW KITCHEN SHOWS A DIMENSION OF 3 FEET 11 3/4
 INCHES FROM COUNTERTOP TO ISLAND. PLEASE MOVE THE
 ISLAND TO SHOW COMPLIANCE WITH
 THE 2017 FBC-ACCESSIBILITY CODE SECTION
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-09-09 Cont ID  
Sent By jpearson Date 2019-09-09 Time 12:57 Rev Time 0.00
Received By jpearson Date 2019-09-09 Time 12:57 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2019-08-15 Cont ID  
Sent By pleduc Date 2019-08-15 Time   Rev Time 0.00
Received By pleduc Date 2019-08-15 Time 14:01 Sent To  
Notes
2019-08-15 14:03:01THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
 1) ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR
 CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND/OR
 FIRE SPRINKLER SYSTEMS BY APPLICABLE LICENSED
 CONTRACTORS FOR CODE COVERAGE COMPLIANCE.
  
 2) ANY AND ALL WORK ON THE FIRE ALARM AND/OR FIRE
 SPRINKLER SYSTEMS SHALL BE DONE UNDER SEPARATE PERMITS
 AND SHOP DRAWINGS.
  
 3) THE EXISTING LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR
 FIRE SPRINKLER SHALL BE MAINTAINED AND REMAIN ACTIVE
 THROUGHOUT THE DEMO AND CONSTRUCTION PERIODS.
  
 PETER LEDUC
 FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-10-09 Cont ID  
Sent By dbattles Date 2019-10-09 Time 13:29 Rev Time 0.00
Received By dbattles Date 2019-10-01 Time 14:14 Sent To  
Notes
2019-10-02 14:15:05RESUB ROUTED TO GJOHNSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-09-13 Cont ID  
Sent By hmoser Date 2019-09-13 Time 09:48 Rev Time 0.00
Received By hmoser Date 2019-08-13 Time 13:07 Sent To  
Notes
2019-08-14 13:08:07B01

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-09-13 Cont ID  
Sent By hmoser Date 2019-09-13 Time 09:47 Rev Time 0.00
Received By hmoser Date 2019-09-12 Time 11:35 Sent To I
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-10-09 Cont ID  
Sent By gjohnson Date 2019-10-09 Time 08:44 Rev Time 0.00
Received By gjohnson Date 2019-10-09 Time 08:44 Sent To  
Notes
2019-10-09 09:38:29PROVISO: COMPLETE BEFORE FINAL INSPECTION
  
 PROVIDE MATCHING PLAN SET THE MEP SHEETS, A-3+4 AND
 LS-1 STILL SHOW ELIMINATED ISLAND IN KITCHEN ALL PLAN
 SHEETS SHALL SHOW KITCHEN WITH NO ISLAND. PER WPB AMEND
 TO FBC 107.2.1\
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-08-30 Cont ID  
Sent By gjohnson Date 2019-08-30 Time 14:07 Rev Time 0.00
Received By gjohnson Date 2019-08-30 Time 14:07 Sent To  
Notes
2019-08-30 14:20:351ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. THE NEW KITCHEN SHALL HAVE A 60" CLEARANCE BETWEEN
 THE CABINETS AND THE ISLAND. PER FBC ACC 212.2, 804.2.2
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]