Plan Review Details - Permit 19080006
Plan Review Stops For Permit 19080006
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2020-08-15 Cont ID  
Sent By pvalenti Date 2020-08-15 Time 13:26 Rev Time 0.00
Received By pvalenti Date 2020-08-15 Time 13:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-08-07 Cont ID  
Sent By pvalenti Date 2019-08-07 Time 15:55 Rev Time 0.00
Received By pvalenti Date 2019-08-07 Time 15:55 Sent To  
Notes
2019-08-07 17:10:04***CORRECTIONS***
 PETER E VALENTI
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6673
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 BUILDING REVIEW OF ELEVATION CERTIFICATE DENIED.
  
 PLEASE SEE THE PENDING ITEMS DESCRIBED BELOW:
  
  
 A9.A. THE SQUARE FOOTAGE OF THE GARAGE SHOWN ON THE
 ELEVATION CERTIFICATE IS 400 S.F, PAGES A-2 AND S-6 OF
 THE PLANS SHOW 586 S.F.
 A9.B. THE NUMBER OF PERMANENT FLOOD OPENINGS, INDICATED
 ON PLANS, IN THE ATTACHED GARAGE WITHIN 1.0 FOOT ABOVE
 ADJACENT GRADE IS (5). THIS ELEVATION CERTIFICATE
 INDICATES (0).
 A9.C. THE TOTAL NET AREA OF FLOOD OPENINGS, INDICATED
 ON PLANS IS 870 S.I.; THIS ELEVATION CERTIFICATE
 INDICATES (0). FLOOD VENTS ARE REQUIRED AS THIS IS A
 SUBSTANTIAL IMPROVEMENT.
 A9.D. THE INFORMATION PROVIDED ON THE PLANS SHOWS THAT
 THE FLOOD OPENINGS ARE ENGINEERED WITH FLOOD VENTS
 (FLOOD SOLUTIONS FS 1412). PLEASE PROVIDE PRODUCT
 APPROVAL FOR THESE VENTS.
  
 C1. IN SELECTING FINISHED CONSTRUCTION, THE GRADING
 AROUND THE BUILDING NEEDS TO BE COMPLETE. PLEASE
 PROVIDE ADDITIONAL PHOTOS SHOWING THE GRADING IS
 COMPLETE.
 C2. I APPOLOGIZE FOR THE PREVIOUS INSTRUCTIONS WHICH
 WERE INCORRECT. PLEASE PROVIDE ELEVATIONS IN NAVD 88
 AND ADD THE CONVERSION FACTOR INTO THE COMMENT AREA.
 C2.A. THROUGH C2.H. WILL NEED TO BE CONVERTED BACK TO
 NAVD 1988.
  
 D. ORIGINAL ELEVATION CERTIFICATES (SIGNED AND SEALED)
 BY SURVEYOR ARE REQUIRED.
 D. COMMENT SECTION :
 PLEASE PROVIDE LOCATIONS OF EQUIPMENT PADS.
 PLEASE PROVIDE THE ACCURATE (586) SQUARE FOOTAGE OF THE
 GARAGE.
 PROVIDE THE CONVERSION FACTOR FOR TRANSITIONING NAVD 88
 TO NVGD 29.
  
  
 G. TO BE COMPLETED BY THE CITY OF WEST PALM BEACH AFTER
 ELEVATION CERTIFICATE IS COMPLETE.
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-08-08 Cont ID  
Sent By pvalenti Date 2019-08-08 Time 10:49 Rev Time 0.00
Received By pvalenti Date 2019-08-01 Time 10:49 Sent To  
Notes
***NONE***