2019-08-01 08:37:47 | JONATHAN BROOKS JR. |
| BUILDING PLANS EXAMINER |
| WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM |
| (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561) |
| 805-6724 |
| [email protected] |
| |
| 1ST REVIEW: FBC 2017 6TH EDITION |
| FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| FBC B = FBC BUILDING |
| FBC R = FBC RESIDENTIAL |
| FBC EB = FBC EXISTING BUILDING |
| FBC A = FBC ACCESSIBILITY |
| FBC EC = FBC ENERGY CONSERVATION |
| WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| RESULTS: DENIED |
| YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| BELOW. |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| 1.FBC R 301 FAC9N-3 FOR FLORIDA STATE PRODUCT APPROVAL, |
| PROVIDE THE FOLLOWING FOR EACH PRODUCT: COVER SHEET |
| (WWW.FLORIDABUILDING.ORG, THIS WILL INCLUDE THE CODE |
| VERSION, PRODUCT APPROVAL NUMBER, STATUS, GENERAL |
| INFORMATION ABOUT THE PRODUCT) EVALUATION REPORT; |
| INSTALLATION INSTRUCTION. THE SUBMITTED INSTALLATION |
| INSTRUCTIONS FOR PRODUCT APPROVAL FL16893-R4 DRAWING |
| #17-666 IS IN-CORRECT. PLEAS PROVIDE TWO SETS OF THE |
| CORRECT INSTALLATION INSTRUCTIONS FOR PRODUCT APPROVAL |
| FL16893-R4 DRAWING #18-048. |
| 2. FBC B 107.2.1. ON THE SCHEDULE FOR INSTALLATION OF |
| PROTECTIVE DEVICES OR ASSEMBLIES: COLUMN HEADING |
| ?SHUTTER MOUNTING CONNECTION TYPE PER PRODUCT |
| APPROVAL?; PROVIDE THE ALPHABETICAL/NUMERICAL CODE THAT |
| CORRESPONDS WITH THE INSTALLATION METHOD USED. EXAMPLE |
| A, B1, G1, F. PROVIDE FOR TOP AND BOTTOM CONNECTION. |
| COLUMN HEADING ?ANCHOR SPACING?; PROVIDE INFORMATION |
| FROM PAGES 13-14. COLUMN HEADING ?SPECIFIC ANCHOR |
| TYPE?; PROVIDE INFORMATION FROM ANCHOR SCHEDULE PAGES |
| 12 USED THE ALPHABETICAL/NUMERICAL CODE THAT |
| CORRESPONDS WITH THE ANCHOR TYPE USED. COLUMN HEADING |
| MARKED "SHUTTER SPAN", THE SHUTTER SPAN IS THE LENTH OF |
| THE BLADE FROM TRACK TO TRACK; NOT THE WIDTH OF THE |
| ASSEMBLY; PAGE 2. |
| |