Plan Review Details - Permit 19071115
Plan Review Stops For Permit 19071115
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2020-02-03 Cont ID  
Sent By cthroop Date 2020-02-03 Time 13:08 Rev Time 0.00
Received By cthroop Date 2020-02-03 Time 11:09 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-11-14 Cont ID  
Sent By cthroop Date 2019-11-14 Time 13:35 Rev Time 0.00
Received By cthroop Date 2019-11-14 Time 13:33 Sent To E
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-08-16 Cont ID  
Sent By cthroop Date 2019-08-16 Time 15:06 Rev Time 0.00
Received By cthroop Date 2019-08-16 Time 08:08 Sent To  
Notes
2019-08-16 15:09:37BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. WATER HEATER REQUIRED PER FBC R2801.1. SHOW LOCATION
 ON FLOOR PLAN.
  
 2. PROVIDE DETAIL FOR PROPOSED SHOWER PAN.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 3. SHOW LOCATION OF WASHING MACHINE IDENTIFIED ON
 PLUMBING ISOMETRIC.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2020-01-24 Cont ID  
Sent By jpearson Date 2020-01-24 Time 15:42 Rev Time 0.00
Received By jpearson Date 2020-01-24 Time 15:42 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2019-11-18 Cont ID  
Sent By jpearson Date 2019-11-18 Time 11:11 Rev Time 0.00
Received By jpearson Date 2019-11-18 Time 11:11 Sent To I
Notes
2019-11-18 11:11:10CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS
 COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY
 HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW
 COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS.
  
 1. CORRECTED.
 2. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE,
 INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF
 SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE
 E3602.2 (A SEPARATE SERVICE IS NOT PERMITTED. PROVIDE
 LOAD CALCULAITON FOR THIS CABANA, AS WELL AS THE MAIN
 SERVICE THAT THIS IS FED FROM.)
 3. CORRECTED.
 4. CORRECTED.
 5. CORRECTED.
  
 NEW COMMENT:
  
 6. AS MENTIONED IN COMMENT 2 RESPONSE, A SEPARATE
 SERVICE IS NOT PERMITTED. ONLY ONE SERVICE PER
 RESIDENTIAL ADDRESS IS PERMITTED. PROVIDE CORRECTION
 AND/OR CLARIFICATION. WPB FBC 107.2.1; NEC 230.2; FBC
 RE E3601.2
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-08-09 Cont ID  
Sent By jpearson Date 2019-08-09 Time 13:30 Rev Time 0.00
Received By jpearson Date 2019-08-09 Time 07:42 Sent To  
Notes
2019-08-09 13:30:30CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
 FAC = FLORIDA ADMINISTRATIVE CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. PROVIDE RISER DIAGRAM OF EXISTING SERVICE. NEC
 215.5; WPB FBC 107.2.1
 2. PROVIDE ACCURATE LOAD CALCULATION FOR SERVICE,
 INCLUDE EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF
 SERVICE IS ADEQUATE. NEC 215.2, 220, 408.30; FBC RE
 E3602.2
 3. PROVIDE LOCATION OF ELECTRICAL PANEL IN CABANA. WPB
 FBC 107.2.1
 4. NOTE 18 AND 19 DO NOT REFLECT THE CURRENT CODES FOR
 AFCI AND TAMPER RESISTANT RECEPTACLES, RESPECTIVELY.
 PROVIDE CORRECTION. NEC 210.12, 406.12; FBC RE
 E3902.16, E4002.14
 5. A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT SHALL BE
 PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH
 CIRCUITS SHALL HAVE NO OTHER OUTLETS. PLAN DOES NOT
 INDICATE THIS. PROVIDE CORRECTION. NEC 210.11(C)(3) ,
 FBC RE E3703.4
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2019-11-12 Cont ID  
Sent By jesmith Date 2019-11-12 Time 15:14 Rev Time 0.00
Received By jesmith Date 2019-11-12 Time 15:13 Sent To  
Notes
2019-11-12 15:14:33PLEASE NOTE THAT A GAS TANKLESS WATER HEATER HAS BEEN
 ADDED TO THE PLAN. AS A RESULT, A GAS PLAN SHALL BE
 SUBMITTED SHOWING ALL INFORMATION REQUIRED BY WPB FBC
 107.3.5.3 (13) AND A SEPARATE GAS PERMIT APPLIED FOR.
  

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2020-01-30 Cont ID  
Sent By aborngra Date 2020-01-30 Time 16:09 Rev Time 0.00
Received By aborngra Date 2020-01-30 Time 16:09 Sent To Z
Notes
2020-01-30 16:09:26THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING
 CONDITION(S):
  
 1. ALL GLASS SHALL BE CLEAR GLASS OR CLEAR GLASS WITH
 LOW-E COATING.
 2. ANY SIDING NEEDING TO BE REMOVED WILL FIRST BE USED
 TO REPAIR THE EXISTING SIDING, IF NOT POSSIBLE CEDAR OR
 CYPRESS SIDING SHALL BE USED WITH THE SAME DIMENSIONS
 AND PROFILE OF THE EXISTING SIDING.
 3. ALL DOORS SHALL HAVE A WHITE EXTERIOR FRAME COLOR
 AND EXTERNAL OGEE DIMENSIONAL MUNTINS.
 4. THE PROPOSED METER TO BE INSTALLED ON THE PROPOSED
 FLOOR PLAN SHALL NOT BE INSTALLED. THE EXISTING METER
 SHALL REMAIN AS PER THE SUBMITTED ELECTRICAL PLANS.
  
 PLEASE NOTE: PGT FD101 DOORS NO LONGER OFFER AN OGEE
 MUNTIN PROFILE. A RAISED/FLAT OR RAISED/RAISED GRID IS
 NOT AN APPROPRIATE MUNTIN PROFILE FOR THESE DOORS. AN
 ALTERNATIVE PRODUCT MAY BE REQUIRED.
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
  

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2019-11-07 Cont ID  
Sent By aborngra Date 2019-11-07 Time 14:46 Rev Time 0.00
Received By aborngra Date 2019-11-07 Time 11:13 Sent To PC
Notes
2019-11-07 14:46:40THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
 1. RELOCATE EXISTING WINDOW TO THE CENTER. A NEW WINDOW
 WILL NOT BE PERMITTED. FOR IMPACT PROTECTION, A
 REMOVABLE SHUTTER OR IMPACT GLASS CAN BE INSTALLED IN
 FRONT.
 2. PROVIDE A MUNTIN DETAIL. AN EXTERNAL OGEE
 DIMENSIONAL MUNTIN WILL BE REQUIRED FOR THE MUNTINS ON
 THE TWO PAIRED FRENCH DOORS. PGT SEEMS TO HAVE
 ELIMINATED OGEE MUNTINS FOR SEVERAL ALUMINUM PRODUCT
 LINES, AN ALTERNATIVE PRODUCT MAY BE REQUIRED.
 3. PROVIDE A STATEMENT DETAILING WHY THE PROPERTY NEEDS
 TO HAVE TWO ELECTRIC METERS.
  
 THE FOLLOWING ARE PROPOSED CONDITIONS OF APPROVAL,
 SUBJECT TO CHANGE.
 A. ALL GLASS SHALL BE CLEAR GLASS OR CLEAR GLASS WITH
 LOW-E.
 B. ANY SIDING NEEDING TO BE REPLACED WILL FIRST BE
 PLACED WITH THE REMOVING SIDING, IF NOT POSSIBLE CEDAR
 OR CYPRESS SIDING SHALL BE USED WITH THE SAME
 DIMENSIONS AND PROFILE OF THE EXISTING.
 C. ALL DOORS SHALL HAVE A WHITE EXTERIOR FRAME COLOR.
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
 [email protected]
  

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2019-08-06 Cont ID  
Sent By aborngra Date 2019-08-06 Time 15:48 Rev Time 0.00
Received By aborngra Date 2019-08-06 Time 15:48 Sent To PC
Notes
2019-08-06 15:48:33THE PERMIT HAS FAILED FOR THE FOLLOWING REASONS:
  
 1. THE PROPOSED CABANA IS CURRENTLY A GARAGE AND COUNTS
 AS ONE OFF-STREET PARKING SPACE. THE PROPERTY IS
 REQUIRED TO HAVE TWO OFF-STREET PARKING SPACES, EACH
 MEASURING APPROXIMATELY 8.5 FEET WIDE BY 18 FEET DEEP.
 2. THE PROPOSED TWO PAIRED FRENCH DOORS ARE
 INAPPROPRIATE. REVISE TO A CENTER PAIRED FRENCH DOOR
 AND RELOCATE THE EXISTING WINDOW TO THE PROPOSED RIGHT
 PAIRED FRENCH DOOR.
  
 PARKING REQUIREMENTS CAN BE FOUND IN SEC. 94-482.
 HTTPS://LIBRARY.MUNICODE.COM/FL/WEST_PALM_BEACH/CODES/C
 ODE_OF_ORDINANCES?NODEID=PTIICOOR_CH94ZOLADERE_ARTXVPA_
 S94-482PARELETHREDWUN
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2020-02-25 Cont ID  
Sent By cthroop Date 2020-02-25 Time 11:45 Rev Time 0.00
Received By cthroop Date 2020-02-25 Time 11:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2020-02-03 Cont ID  
Sent By cthroop Date 2020-02-03 Time 13:09 Rev Time 0.00
Received By cthroop Date 2020-01-15 Time 11:17 Sent To  
Notes
2020-01-16 11:17:48R25

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2019-11-18 Time   Rev Time 0.00
Received By lmarchan Date 2019-10-31 Time 14:01 Sent To  
Notes
2019-11-12 15:28:57ROUTED TO CTHROOP
2019-11-01 14:01:31R25

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-08-16 Cont ID  
Sent By cthroop Date 2019-08-16 Time 15:09 Rev Time 0.00
Received By cthroop Date 2019-07-22 Time 15:36 Sent To  
Notes
2019-07-22 15:36:34R03

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2020-02-25 Cont ID  
Sent By cthroop Date 2020-02-25 Time 14:54 Rev Time 0.00
Received By cthroop Date 2020-02-25 Time 14:54 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-11-14 Cont ID  
Sent By cthroop Date 2019-11-14 Time 13:33 Rev Time 0.00
Received By cthroop Date 2019-11-14 Time 13:33 Sent To  
Notes
2019-11-14 13:34:51PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
2019-10-31 16:20:00GARAGE CONVERSION. CT

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2019-11-04 Cont ID  
Sent By hmoser Date 2019-11-04 Time 13:17 Rev Time 0.00
Received By hmoser Date 2019-11-04 Time 13:02 Sent To  
Notes
2019-11-04 13:17:1011/4/19 NO MECHANICAL WORK BEING DONE AT THIS TIME HM.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-08-15 Cont ID  
Sent By cmontell Date 2019-08-15 Time 14:47 Rev Time 0.00
Received By cmontell Date 2019-08-15 Time 14:47 Sent To  
Notes
2019-08-15 14:48:29MECHANICAL PLAN FAIL
  
 1 - NEED MECHANICAL PLANS PER FBC.MECHANICAL SEC 107.1
  
 CHRIS MONTELLO
 561-805-6733

Review Stop P PLUMBING
Rev No 3 Status P Date 2020-01-23 Cont ID  
Sent By jesmith Date 2020-01-23 Time 14:49 Rev Time 0.00
Received By jesmith Date 2020-01-23 Time 14:49 Sent To  
Notes
2020-01-23 14:49:25PLUMBING COMMENTS: APPROVED W/PROVISO
 1. HAVING NOTED THE EXISTING VTR ON THE REVISED
 PLUMBING RISER, IT IS DETERMINED THAT AT THE PLUMBING
 INSPECTOR?S DISCRETION, ANY EXISTING PLUMBING
 INFRASTRUCTURE SHALL BE SUBJECT TO INSPECTION FOR CODE
 COMPLIANCE. THIS MAY REQUIRE PROVIDING DOCUMENTATION
 OF, OPENING OF WALLS AND/OR FLOORS, PRESSURE TESTS,
 VIDEO CAM OF UNDERGROUND SANITARY, ETC., AS DETERMINED
 BY THE PLUMBING INSPECTOR. PLEASE CALL TIM LARGE AT
 561-805-6692 FOR ADDITIONAL INFORMATION AND/OR
 CLARIFICATION.
 2. ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
 3. SHOWER COMPARTMENT SHALL COMPLY WITH THE
 REQUIREMENTS OF FBC RES P2709
 4. PLEASE NOTE THAT A GAS TANKLESS WATER HEATER HAS
 BEEN ADDED TO THE PLAN. AS A RESULT, A GAS PLAN SHALL
 BE SUBMITTED SHOWING ALL INFORMATION REQUIRED BY WPB
 FBC 107.3.5.3 (13) AND A SEPARATE GAS PERMIT APPLIED
 FOR.
 5. PLEASE NOTE THAT THE SUBMITTED RINNAI RU199IN GAS
 TANKLESS WATER HEATER IS DESIGNED FOR INDOOR USE AND
 NOT OUTDOORS AND THE DOCUMENT PROVIDED IS FOR
 MARKETING, NOT THE MANUFACTURER?S SPECIFICATION/DATA.
 WHEN APPLYING FOR GAS PERMIT PROVIDE MANUFACTURER?S
 SPECIFICATION/DATA SHEETS FOR THE APPROPRIATE OUTDOOR
 UNIT.
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-11-12 Cont ID  
Sent By jesmith Date 2019-11-12 Time 15:13 Rev Time 0.00
Received By jesmith Date 2019-11-12 Time 15:12 Sent To  
Notes
2019-11-12 15:13:10PLUMBING COMMENTS: APPROVED W/PROVISO
 1. HAVING NOTED THE EXISTING VTR ON THE REVISED
 PLUMBING RISER, IT IS DETERMINED THAT AT THE PLUMBING
 INSPECTOR?S DISCRETION, ANY EXISTING PLUMBING
 INFRASTRUCTURE SHALL BE SUBJECT TO INSPECTION FOR CODE
 COMPLIANCE. THIS MAY REQUIRE PROVIDING DOCUMENTATION
 OF, OPENING OF WALLS AND/OR FLOORS, PRESSURE TESTS,
 VIDEO CAM OF UNDERGROUND SANITARY, ETC., AS DETERMINED
 BY THE PLUMBING INSPECTOR. PLEASE CALL TIM LARGE AT
 561-805-6692 FOR ADDITIONAL INFORMATION AND/OR
 CLARIFICATION.
 2. ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
 3. SHOWER COMPARTMENT SHALL COMPLY WITH THE
 REQUIREMENTS OF FBC RES P2709
 4. PLEASE NOTE THAT A GAS TANKLESS WATER HEATER HAS
 BEEN ADDED TO THE PLAN. AS A RESULT, A GAS PLAN SHALL
 BE SUBMITTED SHOWING ALL INFORMATION REQUIRED BY WPB
 FBC 107.3.5.3 (13) AND A SEPARATE GAS PERMIT APPLIED
 FOR.
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-08-14 Cont ID  
Sent By gjohnson Date 2019-08-14 Time 11:23 Rev Time 0.00
Received By gjohnson Date 2019-08-14 Time 11:04 Sent To  
Notes
2019-08-14 12:00:581ST REVIEW:
 2017 FLORIDA BUILDING CODE 6TH EDITION
 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION
 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH
 EDITION
 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH
 EDITION
  
 PLUMBING COMMENTS:
  
 1. THE KITCHEN SINK IS NOT SHOWN ON THE SANITARY
 ISOMETRIC ALL FIXTURES SHALL BE SHOWN TO MATCH FLOOR
 PLAN. PER WPB AMEND TO FBC 107.3.5.3(12)
  
 2. THE SANITARY ISOMETRIC SHOWS A WASHING MACHINE
 PLEASE SHOW LOCATION OF WASHING MACHINE ON FLOOR PLAN.
 PER WPB AMEND TO FBC 107.2.1
  
 3. IF AN AIR ADMITTANCE VALVE IS BEING USED FOR THE
 WASHING MACHINE THE HORIZONTAL DRAIN SHALL BE MIN OF
 3IN PER MANUFACTURE INSTALLATION GUIDE.
  
 4. THE FLOOR PLAN SHOWS A SHOWER AND THE ISOMETRIC
 DRAWING IS SHOWING A TUB PLEASE CLARIFY. PER WPB AMEND
 TO FBC 107.2.1
  
 5. PLEASE SHOW LOCATION, SIZE AND TYPE OF WATER HEATER.
 PER WPB AMEND TO FBC 107.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]

Review Stop Z ZONING
Rev No 3 Status P Date 2020-01-30 Cont ID  
Sent By aborngra Date 2020-01-30 Time 16:10 Rev Time 0.00
Received By aborngra Date 2020-01-30 Time 16:10 Sent To PC
Notes
2020-01-30 16:10:25THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING
 CONDITION(S):
  
 1. ALL GLASS SHALL BE CLEAR GLASS OR CLEAR GLASS WITH
 LOW-E COATING.
 2. ANY SIDING NEEDING TO BE REMOVED WILL FIRST BE USED
 TO REPAIR THE EXISTING SIDING, IF NOT POSSIBLE CEDAR OR
 CYPRESS SIDING SHALL BE USED WITH THE SAME DIMENSIONS
 AND PROFILE OF THE EXISTING SIDING.
 3. ALL DOORS SHALL HAVE A WHITE EXTERIOR FRAME COLOR
 AND EXTERNAL OGEE DIMENSIONAL MUNTINS.
 4. THE PROPOSED METER TO BE INSTALLED ON THE PROPOSED
 FLOOR PLAN SHALL NOT BE INSTALLED. THE EXISTING METER
 SHALL REMAIN AS PER THE SUBMITTED ELECTRICAL PLANS.
  
 PLEASE NOTE: PGT FD101 DOORS NO LONGER OFFER AN OGEE
 MUNTIN PROFILE. A RAISED/FLAT OR RAISED/RAISED GRID IS
 NOT AN APPROPRIATE MUNTIN PROFILE FOR THESE DOORS. AN
 ALTERNATIVE PRODUCT MAY BE REQUIRED.
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
  

Review Stop Z ZONING
Rev No 2 Status F Date 2019-11-07 Cont ID  
Sent By aborngra Date 2019-11-07 Time 14:47 Rev Time 0.00
Received By aborngra Date 2019-11-07 Time 14:46 Sent To PC
Notes
2019-11-07 14:47:02THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S):
 1. RELOCATE EXISTING WINDOW TO THE CENTER. A NEW WINDOW
 WILL NOT BE PERMITTED. FOR IMPACT PROTECTION, A
 REMOVABLE SHUTTER OR IMPACT GLASS CAN BE INSTALLED IN
 FRONT.
 2. PROVIDE A MUNTIN DETAIL. AN EXTERNAL OGEE
 DIMENSIONAL MUNTIN WILL BE REQUIRED FOR THE MUNTINS ON
 THE TWO PAIRED FRENCH DOORS. PGT SEEMS TO HAVE
 ELIMINATED OGEE MUNTINS FOR SEVERAL ALUMINUM PRODUCT
 LINES, AN ALTERNATIVE PRODUCT MAY BE REQUIRED.
 3. PROVIDE A STATEMENT DETAILING WHY THE PROPERTY NEEDS
 TO HAVE TWO ELECTRIC METERS.
  
 THE FOLLOWING ARE PROPOSED CONDITIONS OF APPROVAL,
 SUBJECT TO CHANGE.
 A. ALL GLASS SHALL BE CLEAR GLASS OR CLEAR GLASS WITH
 LOW-E.
 B. ANY SIDING NEEDING TO BE REPLACED WILL FIRST BE
 PLACED WITH THE REMOVING SIDING, IF NOT POSSIBLE CEDAR
 OR CYPRESS SIDING SHALL BE USED WITH THE SAME
 DIMENSIONS AND PROFILE OF THE EXISTING.
 C. ALL DOORS SHALL HAVE A WHITE EXTERIOR FRAME COLOR.
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2019-08-06 Cont ID  
Sent By aborngra Date 2019-08-06 Time 15:49 Rev Time 0.00
Received By aborngra Date 2019-08-06 Time 15:48 Sent To PC
Notes
2019-08-06 15:49:03THE PERMIT HAS FAILED FOR THE FOLLOWING REASONS:
  
 1. THE PROPOSED CABANA IS CURRENTLY A GARAGE AND COUNTS
 AS ONE OFF-STREET PARKING SPACE. THE PROPERTY IS
 REQUIRED TO HAVE TWO OFF-STREET PARKING SPACES, EACH
 MEASURING APPROXIMATELY 8.5 FEET WIDE BY 18 FEET DEEP.
 2. THE PROPOSED TWO PAIRED FRENCH DOORS ARE
 INAPPROPRIATE. REVISE TO A CENTER PAIRED FRENCH DOOR
 AND RELOCATE THE EXISTING WINDOW TO THE PROPOSED RIGHT
 PAIRED FRENCH DOOR.
  
 PARKING REQUIREMENTS CAN BE FOUND IN SEC. 94-482.
 HTTPS://LIBRARY.MUNICODE.COM/FL/WEST_PALM_BEACH/CODES/C
 ODE_OF_ORDINANCES?NODEID=PTIICOOR_CH94ZOLADERE_ARTXVPA_
 S94-482PARELETHREDWUN
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected].
  
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
 [email protected]
  