Plan Review Details - Permit 19071041
Plan Review Stops For Permit 19071041 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2019-08-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-08-13 |
Time |
15:03 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-08-13 |
Time |
15:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2019-07-31 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-07-31 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-07-31 |
Time |
13:53 |
Sent To |
|
|
Notes |
2019-07-31 13:55:08 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. THE ASSEMBLY SELECTED HAS A DESIGN PRESSURE | | LIMITATION OF -75. ENGINEERING IS REQUIRED, OR AN | | ASSEMBLY WHICH MEETS THE REQUIREMENTS FOR ZONES 2 & 3. | | IF THE MEAN ROOF HEIGHT IS PROVIDED, DESIGN PRESSURE | | REQUIREMENTS CAN BE PROVIDED TO YOU VIA EMAIL. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-07-23 |
|
|
Cont ID |
|
Sent By |
jduprey |
Date |
2019-07-23 |
Time |
12:21 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2019-07-23 |
Time |
12:21 |
Sent To |
|
|
Notes |
2019-07-23 12:21:47 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | (561) 805-6716 ALTERNATE: CONTACT SAMANTHA HILL (561) | | 805-6724 | | [email protected] | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1.SUBMITTED PRODUCT APPROVAL FL1654-R23 HAS BEEN | | REVISED TO FL1654-R24. PLEASE PROVIDE TWO SETS. ALL | | APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY | | IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS | | AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT | | APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. AS PER | | RULE 61G20-3 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-07-23 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2019-07-23 |
Time |
12:22 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2019-07-19 |
Time |
13:29 |
Sent To |
|
|
Notes |
2019-07-22 13:29:12 | REVISION ROUTED TO JDUPREY'S DESK |
|
|
|