Plan Review Stops For Permit 19071004 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2019-08-18 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-08-18 |
Time |
12:14 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-08-18 |
Time |
12:14 |
Sent To |
|
|
Notes |
2019-08-18 12:16:38 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | BUILDING REVIEW APPROVED W/PROVISOS: | | | | ALL PRODUCT APPROVALS ARE STILL REQUIRED PRIOR TO | | INSPECTION. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2019-11-19 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-11-19 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-11-19 |
Time |
10:30 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-08-11 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2019-08-11 |
Time |
12:12 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-08-09 |
Time |
13:32 |
Sent To |
|
|
Notes |
2019-08-11 12:12:56 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. LOAD CALCULATION FOR PANEL B SHOWS DEMAND FACTORS | | THAT ARE NOT PERMITTED. BECAUSE THIS IS ONLY A 60 AMP | | FEED, DEMAND FACTORS CANNOT BE USED. DEMAND FACTORS ARE | | ONLY PERMITTED WHEN THE FEEDERS ARE RATED 100 AMPS OR | | MORE. THERFORE, THE CIRCUIT BREAKER FOR THIS WOULD BE | | OVERLOADED. PROVIDE CORRECTION. NEC 220.82; FBC RE | | E3602.2.1 | | 2. ORIGINAL RISER DIAGRAM SHOWS A PANEL BEING INSTALLED | | FOR THE POOL EQUIPMENT. THIS HAS BEEN REMOVED FROM THIS | | DRAWING. WITH THE POOL EQUIPMENT NOW BEING FED FROM | | PANEL B, HOW WILL THIS EQUIPMENT HAVE THE REQUIRED | | DISCONNECT WITHIN SIGHT OF THE EQUIPMENT? PROVIDE | | CLARIFICATION. WPB FBC 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2021-12-22 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2021-12-22 |
Time |
13:07 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2021-12-22 |
Time |
13:07 |
Sent To |
|
|
Notes |
2021-12-22 13:08:34 | A GAS REVIEW HAS NOT BEEN PERFORMED UNDER THIS PERMIT, | | A SEPERATE REVIEW AND GAS PERMIT IS REQUIRED |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2019-12-05 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2019-12-05 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2019-12-05 |
Time |
11:02 |
Sent To |
|
|
Notes |
2021-12-22 10:10:05 | ARMAND PATEL CALLED AND REQUESTED TO HAVE THE GAS | | PORTION REMOVED FROM THE PLANS AND A SEPERATE GAS | | PERMIT AND GAS REVIEW WILL BE SUBMITTED | 2019-12-05 11:38:35 | GAS REVIEW | | | | 1) SUBMIT AN EXPANDED GAS RISER FOR THE AREA OF | | REGULATOR "B". IT IS DIFFICULT TO SEE WHERE THE GAS | | LINES CONTINUE/CONNECT AND TO CHECK IF THE LINES ARE | | PROPERLY SIZED. WPB AMEND. TO FBC SEC. 107.2.1. | | 2) THE GAS RISER SHOWS A 3/4" SUPPLYING A 352 BTUH | | FUTURE GENERATOR. THIS LINE IS UNDERSIZED PER THE | | REFERENCED GAS TABLE. ALSO, INDICATE THE TYPE ON THE | | GAS RISER FOR THE GENERATOR. | | 3) SHOW THE SIZE OF THE PIPE ABOVEGROUND TO THE POOL | | HEATER. WPB AMEND. TO FBC SEC. 107.2.1. | | 4) THE GAS RISER SHOWS A 3/4 INCH PE LINE AT .5 PSI TO | | A FUTURE 400 BTUH POOL HEATER. THIS LINE IS UNDERSIZED | | PER THE REFERENCED GAS TABLE. | | 5) UNIONS ARE REQUIRED WITHIN ONE FOOT UPSTREAM OR | | DOWNSTREAM OF ALL REGULATORS. 2017 FBC-GAS SEC.410.2 | | (7). INDICATE ON THE RISER. | | 6) THE GAS RISER HAS A TABLE FOR REGULATOR "A" & | | REGULATOR "B" BUT THE RISER SHOWS REGULATORS "B" & "C". | | CLARIFY. | | 7) CHECK THE BTU LOAD FOR REGULATOR "B". I CALCULATE | | 947 BTUH ACCORDING TO THE RISER. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-12-05 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2019-12-05 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2019-11-14 |
Time |
15:29 |
Sent To |
|
|
Notes |
2019-11-15 15:29:42 | RESUB ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-08-19 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2019-08-19 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2019-07-19 |
Time |
13:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2019-08-19 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2019-08-19 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2019-08-19 |
Time |
13:22 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
1 |
Status |
P |
Date |
2019-08-18 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-08-18 |
Time |
12:34 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-08-18 |
Time |
12:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2021-12-22 |
|
|
Cont ID |
|
Sent By |
abelisle |
Date |
2021-12-22 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
abelisle |
Date |
2021-12-22 |
Time |
14:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2019-12-05 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2019-12-05 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2019-12-05 |
Time |
09:34 |
Sent To |
|
|
Notes |
2019-12-05 11:01:59 | 1) THE SINK IN THE LAUNDRY ROOM IS NOT SHOWN ON THE | | SANITARY RISER. SHOW THE SINK ON THE SANITARY RISER. | | WPB AMEND. TO FBC SEC. 107.2.1. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2019-08-15 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-08-15 |
Time |
06:32 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2019-08-15 |
Time |
05:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2019-07-30 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2019-07-30 |
Time |
|
Rev Time |
|
Received By |
llouie |
Date |
2019-07-30 |
Time |
|
Sent To |
|
|
Notes |
2019-07-30 10:37:58 | NOTES: | | | | * SEPARATE PERMIT FOR LANDSCAPING REQUIRED PRIOR TO THE | | ISSUANCE OF A CERTIFICATE OF OCCUPANCY (C.O.). A HOLD | | ON THE C.O. HAS BEEN PLACED IN THE SYSTEM. | | | | * ADDITIONAL SEPARATE PERMITS REQUIRED FOR: SWIMMING | | POOL, GENERATOR. | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * ZONE: SF7 | | |
|
|