Plan Review Stops For Permit 19071003 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-09-20 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-09-20 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-09-20 |
Time |
08:46 |
Sent To |
|
|
Notes |
2019-09-20 08:50:34 | PROVISO: | | SKYLIGHT PRODUCT APPROVAL TO BE DEFERRED. | | | | DYLAN BATTLES | | 561-805-6718 | | [email protected] | | | | THE CITY OF WEST PALM BEACH | | BUILDING PLANS EXAMINER PX4191 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-07-26 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-07-26 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-07-26 |
Time |
12:59 |
Sent To |
|
|
Notes |
2019-07-26 13:17:44 | BUILDING REVIEW COMMENTS: | | | | W.P.B. PERMIT: 1901 | | REVIEWED: JULY 26, 2019 | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER PX4191 | | [email protected] | | 561-805-6718 | | | | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) | | FBC[A] = FBC ACCESSIBILITY | | FBC[E] = FBC ENERGY CONSERVATION | | FBC[R] = FBC RESIDENTIAL | | | | 1) 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS FOR | | SKY LIGHT. | | | | 2) 401.2 FBC[RE] PLEASE PROVIDE UPDATED ENERGY | | CALCULATIONS TO INCLUDE THE SKYLIGHT. | | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2019-09-24 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-09-24 |
Time |
15:32 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-09-24 |
Time |
15:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2019-09-23 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-09-23 |
Time |
08:20 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-09-23 |
Time |
08:20 |
Sent To |
|
|
Notes |
2019-09-23 08:20:46 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. CORRECTED. | | 2. CORRECTED. | | | | NEW COMMENTS: | | | | 3. PANEL B AND PANEL P ARE NOW SHOWN BEING FED FROM A | | 100 AMP BREAKER. THE RISER SHOWS THE FEEDER SIZE AS #6 | | WIRE, WHICH IS NOT RATED FOR 100 AMPS. PROVIDE | | CORRECTION. NEC 310.15(B)(16); FBC RE E3705.1 | | 4. RISER SHOWS THE EQUIPMENT GROUNDING CONDUCTOR TO | | PANEL B AND PANEL B SIZED AT #10. THIS IS NOT THE | | CORRECT SIZE FOR A 100 AMP CIRCUIT. PROVIDE CORRECTION. | | NEC 250.122; FBC RE E3704.6, 3607.3.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-08-09 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-08-09 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-08-09 |
Time |
13:32 |
Sent To |
|
|
Notes |
2019-08-09 15:14:31 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. LOAD CALCULATION FOR PANEL B SHOWS DEMAND FACTORS | | THAT ARE NOT PERMITTED. BECAUSE THIS IS ONLY A 60 AMP | | FEED, DEMAND FACTORS CANNOT BE USED. DEMAND FACTORS ARE | | ONLY PERMITTED WHEN THE FEEDERS ARE RATED 100 AMPS OR | | MORE. THERFORE, THE CIRCUIT BREAKER FOR THIS WOULD | | LIKELY BE OVERLOADED. PROVIDE CORRECTION. NEC 220.82; | | FBC RE E3602.2.1 | | 2. ORIGINAL RISER DIAGRAM SHOWS A PANEL BEING INSTALLED | | FOR THE POOL EQUIPMENT. THIS HAS BEEN REMOVED FROM THIS | | DRAWING. WITH THE POOL EQUIPMENT NOW BEING FED FROM | | PANEL B, HOW WILL THIS EQUIPMENT HAVE THE REQUIRED | | DISCONNECT WITHIN SIGHT OF THE EQUIPMENT? PROVIDE | | CLARIFICATION. WPB FBC 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-09-24 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2019-09-24 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2019-09-16 |
Time |
09:42 |
Sent To |
|
|
Notes |
2019-09-24 10:58:47 | TO HM DESK | | | 2019-09-18 09:42:55 | R20 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-08-21 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2019-08-21 |
Time |
13:03 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2019-08-21 |
Time |
13:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2019-09-24 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2019-09-24 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2019-09-24 |
Time |
13:26 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2019-08-21 |
|
|
Cont ID |
|
Sent By |
skennedy |
Date |
2019-08-21 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2019-08-21 |
Time |
12:43 |
Sent To |
I |
|
Notes |
2019-08-21 12:43:46 | PROVISOS | | NEEDS TO COMPLY WITH 2017 FLORIDA BUILDING CODE - FUEL | | GAS, SIXTH EDITION | | 304.5.3.1COMBINING SPACES ON THE SAME STORY. | | EACH OPENING SHALL HAVE A MINIMUM FREE AREA OF 1 SQUARE | | INCH PER 1,000 BTU/H (2,200 MM2/KW) OF THE TOTAL INPUT | | RATING OF ALL APPLIANCES IN THE SPACE, BUT NOT LESS | | THAN 100 SQUARE INCHES (0.06 M2). ONE OPENING SHALL | | COMMENCE WITHIN 12 INCHES (305 MM) OF THE TOP AND ONE | | OPENING SHALL COMMENCE WITHIN 12 INCHES (305 MM) OF THE | | BOTTOM OF THE ENCLOSURE. THE MINIMUM DIMENSION OF AIR | | OPENINGS SHALL BE NOT LESS THAN 3 INCHES (76 MM). | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2019-08-19 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-08-19 |
Time |
11:53 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2019-08-14 |
Time |
13:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2019-08-19 |
|
|
Cont ID |
|
Sent By |
awooten |
Date |
2019-08-19 |
Time |
|
Rev Time |
|
Received By |
awooten |
Date |
2019-08-19 |
Time |
|
Sent To |
|
|
Notes |
|
|