Plan Review Details - Permit 19070954
Plan Review Stops For Permit 19070954
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-11-09 Cont ID  
Sent By cthroop Date 2019-11-09 Time 06:30 Rev Time 0.00
Received By cthroop Date 2019-11-08 Time 08:02 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-10-21 Cont ID  
Sent By cthroop Date 2019-10-21 Time 15:27 Rev Time 0.00
Received By cthroop Date 2019-10-09 Time 09:20 Sent To  
Notes
2019-10-21 15:32:29PLAN REVIEW - BUILDING
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 ADVISORY - HISTORIC PRODUCT APPROVALS
  
 PROPERTY IS LOCATED IN AN ESTABLISHED HISTORIC
 DISTRICT. ALL PRODUCT APPROVALS SHALL BE SUBMITTED AND
 APPROVED PRIOR TO PERMIT.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-08-31 Cont ID  
Sent By cthroop Date 2019-08-31 Time 11:07 Rev Time 0.00
Received By cthroop Date 2019-08-26 Time 17:06 Sent To  
Notes
2019-08-31 11:13:00BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. OWNER/AGENT SHALL SIGN ENERGY SUBMITTAL.
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 2. BUILDER SHALL SIGN EPL CARD.
 R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
 (MANDATORY).
  
 3. DESIGNER SHALL REVIEW AND APPROVE PRODUCT APPROVALS.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING, WINDOW AND DOOR
 SUBMITTALS.
  
 107.3.4.1 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS
 SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE
 PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE
 TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO
 THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD.
 DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR
 APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED
 DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST
 THE DEFERRED SUBMITTALS ON
 THE CONSTRUCTION DOCUMENTS FOR REVIEW BY THE BUILDING
 OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-10-22 Cont ID  
Sent By fgiaquin Date 2019-10-22 Time 06:32 Rev Time 0.00
Received By fgiaquin Date 2019-10-10 Time 06:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-08-24 Cont ID  
Sent By fgiaquin Date 2019-08-24 Time 22:05 Rev Time 0.00
Received By fgiaquin Date 2019-08-23 Time 07:14 Sent To  
Notes
2019-08-24 21:53:13ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 GUEST HOUSE:
  
 1. PROVIDE ACCURATE PANEL SCHEDULES SHOWING OCP, WIRE
 SIZE, AND AFCI/GFCI PROTECTION WHERE APPLICABLE. FBC
 107.2.1 NEC 210.8, 210.12
  
 2. SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS
 REQUIRED. FBC RE 314&315
  
 3. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE.
 FBC EC R404.1
  
 4. GARAGE RECEPTACLES MUST BE GFCI PROTECTED NEC 210.8
  
 5. PROVIDE NOTE ON PLAN THAT STATES LOW VOLTAGE AND
 GENERATOR REQUIRES SEPARATE ELECTRICAL PERMITS. FBC
 107.2.1
  
 6. SERVICE RECEPTACLES REQUIRED FOR AHU'S AND A/C
 CONDENSORS NEC 210.63
  
 MAIN HOUSE:
  
 1. PROVIDE ACCURATE PANEL SCHEDULES SHOWING OCP, WIRE
 SIZE, AND AFCI/GFCI PROTECTION WHERE APPLICABLE. FBC
 107.2.1 NEC 210.8, 210.12
  
 2. PROVIDE LOCATIONS ON PLANS OF ALL PANELS SHOWN ON
 ONE-LINE/RISER DIAGRAM. PROVIDE LOCATIONS FOR ALL THREE
 ATS'S, ALL SUB-PANELS, AND POOL PANEL. ALL LOCATIONS
 NOW SHOWN ON PLAN. FBC 107.2.1
  
 3. SMOKE DETECTORS/ CARBON MONOXIDE DETECTORS REQUIRED
 PER FBC RE 314&315. PROVIDE CORRECTION.
  
 4. PROVIDE NOTE ON PLAN THAT STATES LOW VOLTAGE AND
 GENERATOR REQUIRES SEPARATE ELECTRICAL PERMITS. FBC
 107.2.1
  
 5. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE
 LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF
 THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
 CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE.
 FBC EC R404.1
  
 6. LIGHTING PLAN AND POWER PLAN DO NOT HAVE SAME
 STRUCTURAL LAYOUT. POWER PLAN SHOWS A ROOM ADJACENT TO
 BEDROOM#2 AND BATHROOM #2 BUT IS NOT SHOWN ON LIGHTING
 PLAN?? PROVIDE ACCURATE DRAWINGS SHOWING ALL DOOR AND
 ROOM LOCATIONS THAT MATCH ON BOTH ELEC AND LIGHTING
 PLANS FBC 107.2.1
  
 7. NO ELECTRIC SHOWN FOR A/C CONDENSORS OUTSIDE? FBC
 107.2.1
  
 8. NO LOCATIONS SHOWN FOR AHU'S OR ELECTRIC. FBC
 107.2.1
  
 9. NO ATTIC ACCESS SHOWN? MUST SHOW ATTIC ACCESS WITH
 PROPER ELECTRICAL REQUIRED. FBC 107.2.1
  
 10. MUST HAVE BONDING BRIDGE AT SERVICE. NEC 250.94
  
 11. SERVICE RECEPTACLES REQUIRED FOR AHU'S AND A/C
 CONDENSORS NEC 210.63
  
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  

Review Stop HIST HISTORICAL
Rev No 3 Status P Date 2019-10-30 Cont ID  
Sent By fmittner Date 2019-10-30 Time 13:41 Rev Time 0.00
Received By fmittner Date 2019-10-30 Time 13:41 Sent To  
Notes
2019-10-30 13:42:13ALL ARCHITECTURAL DETAILS TO MATCH THOSE APPROVED BY
 HPB. HISTORIC DESIGN DETAILS FROM BOARD SET SUPERSEDES
 THOSE IN PERMIT SET.

Review Stop HIST HISTORICAL
Rev No 2 Status F Date 2019-10-11 Cont ID  
Sent By fmittner Date 2019-10-11 Time 13:23 Rev Time 0.00
Received By fmittner Date 2019-10-11 Time 13:23 Sent To  
Notes
2019-10-11 13:32:05DETAILS IN ELEVATIONS STILL DO NOT MATCH HPB APPROVAL
 OR HISTORIC PHOTO, SUCH AS:
 - SCALLOP OF ENTRY PORCH MISSING
 - BRITTANY STYLE DOORS NOT ORIGINAL PATTERN
 - EAST PORCH ROOF LINE MISSING RAFTER TAILS
 - PANEL BELOW PORCH WINDOWS MISSING INSET PANEL
  
 ETC.

Review Stop HIST HISTORICAL
Rev No 1 Status F Date 2019-08-27 Cont ID  
Sent By fmittner Date 2019-08-27 Time 11:38 Rev Time 0.00
Received By fmittner Date 2019-08-27 Time 11:38 Sent To  
Notes
2019-08-27 11:44:51SYNTHETIC ROOFING MATERIAL NOT PERMITTED.
  
 ALL ELEVATIONS/PRODUCTS TO MATCH WHAT WAS APPROVED BY
 THE HISTORIC PRESERVATION BOARD.
  
 QUESTIONS CONTACT FRIEDERIKE MITTNER AT (561) 822-1457

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-11-09 Cont ID  
Sent By cthroop Date 2019-11-09 Time 06:29 Rev Time 0.00
Received By cthroop Date 2019-10-29 Time 15:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-10-22 Cont ID  
Sent By lmarchan Date 2019-10-22 Time 07:37 Rev Time 0.00
Received By lmarchan Date 2019-10-08 Time 11:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-08-31 Cont ID  
Sent By cthroop Date 2019-08-31 Time 11:18 Rev Time 0.00
Received By cthroop Date 2019-08-06 Time 16:10 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2019-10-24 Cont ID  
Sent By lmarchan Date 2019-10-24 Time 07:58 Rev Time 0.00
Received By lmarchan Date 2019-10-22 Time 07:37 Sent To  
Notes
2019-10-23 15:42:42RECEIPT 2019-1023-221 - $22.46 - PAID
2019-10-22 07:37:5710/22/19 SENT EMAIL TO IMPACT FEE OFFICE. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-08-31 Cont ID  
Sent By cthroop Date 2019-08-31 Time 11:16 Rev Time 0.00
Received By cthroop Date 2019-08-26 Time 17:06 Sent To  
Notes
2019-08-31 11:18:49PALM BEACH COUNTY IMPACT FEES
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. APPLICANT SHALL SUBMIT IMPACT FEES QUESTIONAIRE.
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-08-31 Cont ID  
Sent By cthroop Date 2019-08-31 Time 11:13 Rev Time 0.00
Received By cthroop Date 2019-08-26 Time 17:06 Sent To  
Notes
***NONE***

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status N Date 2019-09-05 Cont ID  
Sent By cthroop Date 2019-09-05 Time 08:39 Rev Time 0.00
Received By cthroop Date 2019-09-05 Time 08:39 Sent To  
Notes
2019-09-05 08:41:35PROPERTY IS LOCATED IN A SFHA. ZONE AE 6.0 W DFE OF 8.0
 FT. NAVD. 2019 IMPROVEMENT VALUE IS $176,111 AND VALUE
 OF THIS PERMIT PLUS A FIVE YEAR TAIL IS $780,000.
 PROJECT IS CLASSIFIED AS A S/I PER FEMA 50% RULE.
  
  
 CONTRIBUTING HOUSE LOCATED IN A HISTORIC DISTRICT.
 EXEMPT FROM SUBSTANTIAL IMPROVEMENT PER FBC EXISTING
 BUILDING CHPT. 12 SECTION 1201.3.
  
 CBAA WAIVER REQUIRED PER CITY ORDINANCE NO. 4729-17 AND
 FBC CHPT 12 HISTORIC BUILDINGS. CT

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-08-31 Cont ID  
Sent By cthroop Date 2019-08-31 Time 11:13 Rev Time 0.00
Received By cthroop Date 2019-08-26 Time 17:06 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status P Date 2019-11-09 Cont ID  
Sent By cthroop Date 2019-11-09 Time 06:29 Rev Time 0.00
Received By cthroop Date 2019-11-08 Time 08:02 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2019-10-21 Cont ID  
Sent By cthroop Date 2019-10-21 Time 15:32 Rev Time 0.00
Received By cthroop Date 2019-10-09 Time 09:20 Sent To  
Notes
2019-10-21 15:33:20PLAN REVIEW - ROOFING
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 2ND REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 ADVISORY - HISTORIC PRODUCT APPROVALS
  
 PROPERTY IS LOCATED IN AN ESTABLISHED HISTORIC
 DISTRICT. ALL PRODUCT APPROVALS SHALL BE SUBMITTED AND
 APPROVED PRIOR TO PERMIT.
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2019-08-31 Cont ID  
Sent By cthroop Date 2019-08-31 Time 11:13 Rev Time 0.00
Received By cthroop Date 2019-08-26 Time 17:06 Sent To  
Notes
2019-08-31 11:15:24BUILDING PLAN REVIEW - ROOFING
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
  
 RESULTS: DENIED
  
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. DESIGNER SHALL REVIEW AND APPROVE PRODUCT APPROVALS.
  
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2019-11-09 Cont ID  
Sent By cthroop Date 2019-11-09 Time 06:29 Rev Time 0.00
Received By cthroop Date 2019-11-08 Time 08:02 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-10-21 Cont ID  
Sent By cthroop Date 2019-10-21 Time 15:26 Rev Time 0.00
Received By cthroop Date 2019-10-09 Time 09:20 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2019-08-31 Cont ID  
Sent By cthroop Date 2019-08-31 Time 11:15 Rev Time 0.00
Received By cthroop Date 2019-08-26 Time 17:06 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2019-10-30 Cont ID  
Sent By fmittner Date 2019-10-30 Time 13:40 Rev Time 0.00
Received By fmittner Date 2019-10-30 Time 13:40 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2019-08-27 Cont ID  
Sent By pgreilic Date 2019-08-27 Time 11:39 Rev Time 0.00
Received By fmittner Date 2019-08-27 Time 11:39 Sent To  
Notes
2019-08-27 11:46:00REQURIES SUBMITTAL OF SEPERATE LANDSCAPE PLAN.
  
 QUESTIONS, CONTACT RAY CARANCI