Plan Review Details - Permit 19070947
Plan Review Stops For Permit 19070947 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2019-07-30 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-07-30 |
Time |
13:11 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-07-30 |
Time |
13:11 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2019-07-24 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-07-24 |
Time |
06:33 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-07-24 |
Time |
06:33 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-07-31 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2019-07-31 |
Time |
15:06 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2019-07-26 |
Time |
11:27 |
Sent To |
|
|
Notes |
2019-07-30 11:27:24 | RESUB ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-07-24 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-07-18 |
Time |
11:11 |
Sent To |
|
|
Notes |
2019-07-19 11:11:13 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2019-07-31 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2019-07-31 |
Time |
14:19 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2019-07-31 |
Time |
13:42 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2019-07-23 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2019-07-23 |
Time |
16:42 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2019-07-23 |
Time |
16:42 |
Sent To |
PC |
|
Notes |
2019-07-23 17:01:12 | FAILED | | | | PROVIDE WRITTEN RESPONSES TO COMMENTS. | | | | 1) THE LOCATION OF THE POLES ON THE CITY COMMISSION | | APPROVED SITE PLAN AND THE SUBMITTED ELECTRICAL PLANS | | BY EDA DIFFER THAN THE PLANS PROVIDED BY MUSCO. THE | | MUSCO PLANS HAVE THE POLES CLOSER TOGETHER. ALL PLANS | | NEED TO SHOW THE SAME CONDITIONS. IF THE MUSCO PLANS | | WILL BE THE INSTALL VERSION, THEN PRIOR TO FINAL | | INSPECTION, A MINOR AMENDMENT TO REVISE THE CITY | | COMMISSION SITE PLAN IS REQUIRED AND THE ELECTRICAL | | PLAN SITE PLAN NEEDS TO BE CORRECTED PRIOR TO PERMIT | | ISSUANCE. | | | | 2) THERE IS ONE LOCATION AT THE SOUTH PROPERTY LINE | | WHERE THE ONE FOOT CANDLE ALLOWANCE IS EXCEEDED. PLEASE | | REVISE THE PLANS ACCORDINGLY. | | | | 3) PROVIDE A DRAWING WITH THE EXACT POLE AND FIXTURES | | THAT INCLUDES THE OVERALL HEIGHT OF THE POLE AND THE | | FIXTURES FROM GRADE. THE INFORMATION PROVIDED IN | | APPENDICES E AND G SHOW POLES BUT DO NOT INCLUDE THE | | OVERALL HEIGHT WITH THE FIXTURES FROM GRADE. THE | | OVERALL HEIGHT MAY NOT EXCEED 80 FEET. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | [email protected] |
|
|
|