Plan Review Stops For Permit 19070836 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-08-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-08-20 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-08-16 |
Time |
16:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-08-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-08-05 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-08-02 |
Time |
15:09 |
Sent To |
|
|
Notes |
2019-08-05 09:16:25 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE FLOOR PLAN OF EXISTING LAYOUT. | | 2. PROVIDE FLOOR PLAN OF PROPOSED LAYOUT | | | | PLUMBING AND ELECTRICAL PLANS MAY BE REQUIRED | | | | IF ISLAND IS NEW PROVIDE CONCRETE REPAIR DETAIL. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2019-09-21 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2019-09-21 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2019-09-20 |
Time |
09:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2019-08-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-08-20 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-08-20 |
Time |
10:26 |
Sent To |
|
|
Notes |
2019-08-20 10:53:04 | ELECTRICAL PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | COMMENTS FROM 1ST REVIEW HAVE NOT BEEN ADDRESSED. | | | | 1.PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED BY PERSON | | RESPONSIBLE FOR THE DESIGN. FS 481.229; WPB FBC | | 107.2.1, 107.3.5.1.2 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | 1. PROVIDE CODE COMPLIANT ELECTRICAL PLAN. | | 2. PROVIDE RISER DIAGRAHM. | | 3. PROVIDE PANEL SCHEDULE. | | 4. ELECTRICAL SUB PERMIT REQUIRED. | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-07-28 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2019-07-28 |
Time |
05:31 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2019-07-28 |
Time |
05:00 |
Sent To |
|
|
Notes |
2019-07-28 05:31:08 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1.PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED BY PERSON | | RESPONSIBLE FOR THE DESIGN. FS 481.229; WPB FBC | | 107.2.1, 107.3.5.1.2 | | | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-657-1653 | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-09-21 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-21 |
Time |
11:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-17 |
Time |
09:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-08-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-08-20 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-08-14 |
Time |
09:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-08-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-08-05 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-07-24 |
Time |
09:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2019-09-21 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-21 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-21 |
Time |
11:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2019-08-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-08-20 |
Time |
10:53 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-08-16 |
Time |
16:15 |
Sent To |
|
|
Notes |
2019-08-20 10:55:33 | PLUMBING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE PLUMBING RISER DIAGRAHM (ISOMETRIC) | | | | 2. PLUMBING SUB PERMIT 19080261 ON FILE. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-08-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-08-05 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-08-02 |
Time |
15:09 |
Sent To |
|
|
Notes |
2019-08-05 09:18:22 | PLUMBING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE FLOOR PLAN OF EXISTING LAYOUT. | | 2. PROVIDE FLOOR PLAN OF PROPOSED LAYOUT | | | | PLUMBING PLANS MAY BE REQUIRED (ISOMETRIC) | | | | IF ISLAND IS NEW PROVIDE CONCRETE REPAIR DETAIL. | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | DETERMINED BY THE BUILDING OFFICIAL. | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2019-09-21 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-21 |
Time |
11:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-21 |
Time |
11:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2019-08-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-08-20 |
Time |
10:55 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-08-16 |
Time |
16:15 |
Sent To |
|
|
Notes |
2019-08-20 10:57:13 | SIGNATURE REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | | | RESULTS: DENIED | | | | NEW PLAN PAGES WILL NEED TO BE REVIEWED FOR COMPLIANCE. | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2019-08-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-08-05 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-08-02 |
Time |
15:09 |
Sent To |
|
|
Notes |
2019-08-05 09:13:20 | BUILDING PLAN REVIEW - SIGNATURE REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. DESIGNER TO PRINT NAME AND SIGN PLANS. | | | | FBC 107.2.1 ALL INFORMATION, DRAWINGS, SPECIFICATIONS | | AND ACCOMPANYING DATA SHALL BEAR THE NAME AND SIGNATURE | | OF THE PERSON RESPONSIBLE FOR THE DESIGN. (SEE ALSO | | SECTION 107.3.5) AND F.S. 481.229. | | | | |
|
|