Plan Review Details - Permit 19070440
Plan Review Stops For Permit 19070440 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-08-26 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2019-08-27 |
Time |
08:40 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-08-26 |
Time |
16:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-08-05 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-08-05 |
Time |
08:14 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-07-29 |
Time |
08:28 |
Sent To |
|
|
Notes |
2019-08-05 08:14:41 | BUILDING REVIEW COMMENTS: | | | | W.P.B. PERMIT: 19070440 | | REVIEWED: AUGUST 5, 2019 | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER PX4191 | | [email protected] | | 561-805-6718 | | | | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) | | FBC[B] = FBC BUILDING | | FBC[EXISTING] = FBC EXISTING BUILDING | | FBC[A] = FBC ACCESSIBILITY | | FBC[E] = FBC ENERGY CONSERVATION | | | | 1) 107.2.5 FBC[AMENDED] DEMOLITION PLAN. | | PROVIDE DEMOLITION PLAN TO SHOW EXISTING CONFIGURATION, | | AREA AND DIMENSIONS. | | | | 2) ARE THERE ANY CHANGES IN CONFIGURATION OF KITHEN OR | | BATHROOMS? | | | | 3) WHAT IS THE AREA OF TILE BEING REPLACED? | | | | 4) PLEASE VERIFY THICKNESS OF CONCRETE ASSEMBLY. WE | | HAVE PERMITS ON FILE THAT STATE 8 INCHES AS WELL. YOU | | SHOULD BE ABLE TO GET THAT INFO FROM THE BUILDING | | MANAGER, OR FIELD VERIFY. | | | | WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
N |
Date |
2019-08-27 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2019-08-26 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2019-08-26 |
Time |
14:54 |
Sent To |
B |
|
Notes |
2019-08-26 14:55:48 | NO ELECTRICAL TO REVIEW |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-07-30 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2019-07-30 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2019-07-30 |
Time |
11:34 |
Sent To |
|
|
Notes |
2019-08-26 14:53:56 | NO ELECTRICAL TO REVIEW | 2019-07-30 11:34:03 | NO ELECTRICAL TO REVIEW | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2019-07-12 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-07-12 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-07-12 |
Time |
14:00 |
Sent To |
|
|
Notes |
2019-07-12 14:02:02 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | INSPECTION. | | | | | | 1) MAINTAIN THE FIRE ALRAM THROUGHOUT DEMO AND | | CONSTRUCTION. | | | | | | 2) DO NOT PAINT OVER ANY FA DEVICES. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-08-26 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-08-26 |
Time |
16:39 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-08-13 |
Time |
13:17 |
Sent To |
|
|
Notes |
2019-08-14 13:17:18 | RESUB ROUTED TO PPETTY |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-08-05 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-08-05 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-07-10 |
Time |
15:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2019-08-05 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-08-05 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-07-29 |
Time |
08:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2019-08-05 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-08-05 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-08-05 |
Time |
08:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2019-07-26 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-07-26 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-07-26 |
Time |
09:43 |
Sent To |
|
|
Notes |
|
|
|