Plan Review Details - Permit 19070047
Plan Review Stops For Permit 19070047 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2019-07-12 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-07-12 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-07-12 |
Time |
13:22 |
Sent To |
|
|
Notes |
2019-07-12 13:23:04 | PUT IN THE RESULTS FOR RMCD JLEAHY |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2019-07-12 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-07-12 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-07-12 |
Time |
13:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-07-19 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-07-19 |
Time |
07:24 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2019-07-17 |
Time |
15:20 |
Sent To |
|
|
Notes |
2019-07-18 15:21:10 | RESUB ROUTED TO LCRESPO |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-07-12 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-07-12 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-07-01 |
Time |
11:28 |
Sent To |
|
|
Notes |
2019-07-02 11:29:04 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2019-07-19 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-07-19 |
Time |
07:24 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2019-07-19 |
Time |
07:24 |
Sent To |
|
|
Notes |
2019-07-19 07:25:07 | 07/19/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING/POOL) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6720 | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-07-08 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-07-08 |
Time |
13:25 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2019-07-08 |
Time |
13:25 |
Sent To |
|
|
Notes |
2019-07-08 13:25:21 | 07/08/2019 1ST PLUMBING/POOL REVIEW **DENIED** WITH | | COMMENTS | | | | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS | | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE | | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. | | | | 1. ON POOL PUMP CURVE FOR THE MODEL SP2310X52* IS | | HIGHLIGHTED AND SP2305X7EESP* IS CIRCLED BUT DOES NOT | | COINCIDE WITH YOUR TDH LOOS, THE MODEL SP2307X10 IS THE | | ONE THE FITS THIS CURVE. PLEASE CLARIFY AND MAKE THE | | NECESSARY CHANGES TO REFLECT THE CORRECT PUMP CURVE. | | WPB AMENDMENTS TO FBC SEC. 107.2.1. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | LUIS A. CRESPO | | PLUMBING INSPECTOR / | | PLUMBING PLAN REVIEW | | AVAILABLE FROM 1:00 PM TO 4:00 PM | | [email protected] | | 561-805-6720 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2019-07-08 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2019-07-08 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2019-07-08 |
Time |
14:01 |
Sent To |
|
|
Notes |
2019-07-08 14:01:50 | THIS REVIEW HAS BEEN PASSED SUBJECT TO THE FOLLOWING | | PROVISOS: | | | | 1. ALL POOL EQUIPMENT SHALL BE A MINIMUM OF ONE (1) | | FOOT FROM THE SIDE PROPERTY LINE. | | | | 2. POOL SHALL BE ENCLOSED BY A PERMANENT FENCE OR | | SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS | | BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE | | RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED | | (?BABY FENCE? DOES NOT MEET THIS REQUIREMENT). BARRIERS | | OR FENCES SHALL BE AT LEAST 4 FEET IN HEIGHT ABOVE | | GRADE. | | | | 3. ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH | | A BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING | | GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES | | PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE. | | | | 4. PATIO OR PAVED AREA ADJACENT TO OR SURROUNDING THE | | POOL SHALL BE DESIGNED TO DRAIN AWAY FROM THE POOL, BUT | | NOT ONTO ADJACENT PROPERTIES. | | ___________________________________________ | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | ___________________________________________ | | | | QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING: | | | | JOHN P. ROACH, AICP, PRINCIPAL PLANNER | | CITY OF WEST PALM BEACH | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION | | 401 CLEMATIS STREET - P.O. BOX 3147 | | WEST PALM BEACH, FLORIDA 33402 | | | | P: 561.822.1448 | | E: [email protected] | | | | W: WPB.ORG | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2019-07-03 |
|
|
Cont ID |
|
Sent By |
ajones |
Date |
2019-07-03 |
Time |
13:07 |
Rev Time |
0.00 |
Received By |
ajones |
Date |
2019-07-03 |
Time |
13:07 |
Sent To |
|
|
Notes |
2019-07-03 13:09:37 | 7/3/19- FAILED- REAR SETBACK MUST BE SHOWN ON THE | | SURVEY. | | | | ANGELLA VANN, AICP | | 561-822-1441 | | [email protected] |
|
|
|