Plan Review Details - Permit 19061265
Plan Review Stops For Permit 19061265 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2019-07-31 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2019-07-31 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2019-07-31 |
Time |
09:53 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2019-07-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2019-07-19 |
Time |
19:00 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2019-07-19 |
Time |
18:42 |
Sent To |
I |
|
Notes |
2019-07-19 19:00:27 | PLAN | | REVIEW COMMENTS | | | | 2ND REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) COMPLIED. | | | | 2) COMPLIED. | | | | 3) PARTIALLY COMPLIED. THE INFORMATION PROVIDED IS | | INCOMPLETE. THE INSTALLATION SCHEDULE SPECIFIES THAT | | THE SUBSTRATE IS WOOD FOR BOTH THE FIRST AND SECOND | | FLOORS. THE PROPERTY APPRAISER'S WEBSITE INDICATES THAT | | THE FIRST FLOOR IS CBS AND THE SECOND FLOOR IS WOOD | | FRAME STUCCO. THE ACCORDION SHUTTERS ARE ALWAYS | | INSTALLED VERTICALLY NOT HORIZONTALLY AS SPECIFIED ON | | THE SCHEDULE. THE TYPE OF ANCHOR IS LISTED AS ALL POINT | | SOLID SET IN ONE PLACE AND TAPCON 2 1/4" IS LISED IN | | THE SCHEDULE. THE SHUTTER MOUNTING IS SPECIFIED AS #14 | | AND I WAS UNABLE TO DETERMINE WHICH MOUNTING YOU WILL | | USE. PLEASE CIRCLE THE MOUNTINGS AND ANCHOR SPACINGS | | YOU WILL USE IN THE PRODUCT APPROVAL DETAILS AND ANCHOR | | SCHEDULES. FBC 107.2.1 FBC - R 301.2.1.2 SUBMIT TWO | | COPIES OF AN INSTALLATION SCHEDULE AND KEY PLAN FOR THE | | STORM PANELS. SPECIFY THE OPENING SIZE, THE WIND | | PRESSURES, TYPE OF ANCHOR, ANCHOR SPACING, EDGE | | DISTANCE, PANEL LENGTH, PANEL SPAN, SEPARATION DISTANCE | | FROM PANEL TO GLASS AND THE APPLICABLE SECTION NUMBER | | FROM THE INSTALLATION DRAWINGS. I HAVE INCLUDED A LINK | | TO THE CONSTRUCTION SERVICES DEPARTMENT SITE THAT HAS | | MANY OF THE RELATED FORMS INCLUDING THE SCHEDULE FOR | | INSTALLATION OF OPENING PROTECTIVE DEVICES. | | HTTP://WPB.ORG/DEVELOPMENT/FORMS-AND-PUBLICATIONS/ | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-07-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2019-07-08 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2019-07-08 |
Time |
08:40 |
Sent To |
I |
|
Notes |
2019-07-08 08:45:06 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE PROJECT IS LOCATED IN EXPOSURE CATEGORY C. THE | | COMPONENT AND CLADDING PRESSURES AND THE EXPOSURE | | CATEGORY LISTED ON THE FORM THAT WAS SUBMITTED IS | | EXPOSURE CATEGORY B. IN ORDER TO USE EXPOSURE B, YOU | | WILL NEED TO PROVIDE A SITE SPECIFIC ANALYSIS SHOWING | | THAT THIS PROPERTY IS ACTUALLY EXPOSURE CATEGORY B. THE | | ANALYSIS IS REQUIRED TO BE PRODUCED BY AND SIGNED AND | | SEALED BY A FLORIDA LICENSED PROFESSIONAL ENGINEER. FBC | | 107.2.1 & FS 471 | | | | 2) THE MEAN ROOF HEIGHT FOR THIS BUILDING IS 25 FEET | | PER THE INFORMATION THAT YOU PROVIDED. YOU NEED TO USE | | THE MEAN ROOF HEIGHT OF THE BUILDING FOR DETERMINING | | THE COMPONENT AND CLADDING PRESSURES FOR THE SHUTTERS. | | FBC R301.2.1 | | | | FBC - R 301.2.1.2 SUBMIT TWO COPIES OF AN INSTALLATION | | SCHEDULE AND KEY PLAN FOR THE STORM PANELS. SPECIFY THE | | OPENING SIZE, THE WIND PRESSURES, TYPE OF ANCHOR, | | ANCHOR SPACING, EDGE DISTANCE, PANEL LENGTH, PANEL | | SPAN, SEPARATION DISTANCE FROM PANEL TO GLASS AND THE | | APPLICABLE SECTION NUMBER FROM THE INSTALLATION | | DRAWINGS. I HAVE INCLUDED A LINK TO THE CONSTRUCTION | | SERVICES DEPARTMENT SITE THAT HAS MANY OF THE RELATED | | FORMS INCLUDING | | THE SCHEDULE FOR INSTALLATION OF OPENING PROTECTIVE | | DEVICES. | | HTTP://WPB.ORG/DEVELOPMENT/FORMS-AND-PUBLICATIONS/ | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-07-31 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2019-07-31 |
Time |
09:53 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2019-07-26 |
Time |
14:21 |
Sent To |
|
|
Notes |
2019-07-30 14:21:34 | RESUB ROUTED TO RMCDOUGAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-07-19 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2019-07-19 |
Time |
19:00 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2019-07-17 |
Time |
15:13 |
Sent To |
|
|
Notes |
2019-07-18 15:13:36 | RESUB ROUTED TO RMCDOUGAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-07-08 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2019-07-08 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2019-06-26 |
Time |
10:01 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |