Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-07-11 Cont ID  
Sent By jbrooks Date 2019-07-11 Time 08:02 Rev Time 0.00
Received By jbrooks Date 2019-07-11 Time 08:02 Sent To  
Notes
2019-07-11 08:05:541ST REVIEW: FBC 2017 6TH EDITION
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. FBC B 107.1 SUBMITTAL DOCUMENTS CONSISTING OF
 CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL
 INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL
 BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT
 APPLICATION. THE CONSTRUCTION DOCUMENTS SHALL BE
 PREPARED BY A REGISTERED DESIGN PROFESSIONAL WHERE
 REQUIRED BY CHAPTER 471, FLORIDA STATUTES & 61G15
 FLORIDA ADMINISTRATIVE CODE OR CHAPTER 481, FLORIDA
 STATUTES & 61G1 FLORIDA ADMINISTRATIVE CODE. WHERE
 SPECIAL CONDITIONS EXIST, THE BUILDING OFFICIAL IS
 AUTHORIZED TO REQUIRE ADDITIONAL CONSTRUCTION DOCUMENTS
 TO BE PREPARED BY A REGISTERED DESIGN PROFESSIONAL.
 ELECTRONIC MEDIA DOCUMENTS SHALL BE SUBMITTED WHEN
 REQUIRED BY THE BUILDING OFFICIAL AND MAY REQUIRE ONLY
 ONE SET OF SUBMITTALS.
 2. FBC EB 801.1 & 801.2 LEVEL 2 ALTERATIONS AS
 DESCRIBED IN SECTION 504 SHALL COMPLY WITH THE
 REQUIREMENTS OF CHAPTER 8. IN ADDITION TO THE
 REQUIREMENTS OF THIS CHAPTER, ALL WORK SHALL COMPLY
 WITH THE REQUIREMENTS OF CHAPTER 7.
 3. FBC B 107.2.1 CONSTRUCTION DOCUMENTS SHALL BE
 DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL.
 ELECTRONIC MEDIA DOCUMENTS SHALL BE SUBMITTED WHEN
 APPROVED BY THE BUILDING OFFICIAL. CONSTRUCTION
 DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE
 THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED
 AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING
 OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES
 SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE
 TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE
 FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE
 NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE
 DESIGN.
 4. PROVIDE TWO SETS OF PRODUCT APPROVALS/NOA'S FOR THE
 PROPOSED EXTERIOR DOOR TO BE USED. AS PER FAC9N-3
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2019-06-28 Cont ID  
Sent By pleduc Date 2019-06-28 Time   Rev Time 0.00
Received By pleduc Date 2019-06-28 Time 11:07 Sent To B
Notes
2019-06-28 11:09:19THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
  
 1) THERE IS INSUFFICIENT INFORMATION SUBMITTED TO
 DETERMINE COMPLIANCE WITH THE FLORIDA FIRE PREVENTION
 CODE.
  
 GREATER DETAIL IS REQUIRED INCLUDING SIZE OF OPENING,
 HORIZONTAL VIEWS, INSIDE AND OUTSIDE, ETC.
  
  
  
 2) A DOOR IS PROPOSED TO BE REMOVED. THERE ARE NO
 INDICATIONS IF THIS IS A REQUIRED EXIT DOOR, PER NFPA
 101, CH 7 MEANS OF EGRESS.
  
 A MINIMUM OF TWO EXITS ARE REQUIRED AND ONE CAN NOT
 HAVE PATRONS EXITING THROUGH THE KITCHEN AREA.
  
 A DETAILED LIFE SAFETY PLAN IS REQUIRED SHOWING
 COMPLIANCE WITH REQUIRED EXITING IN COMPLIANCE WITH THE
 ABOVE CODE.
  
  
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-07-11 Cont ID  
Sent By jbrooks Date 2019-07-11 Time 08:06 Rev Time 0.00
Received By jbrooks Date 2019-06-25 Time 11:45 Sent To  
Notes
2019-06-27 11:45:35ROUTED TO FIRE INBOX