Plan Review Details - Permit 19060927
Plan Review Stops For Permit 19060927 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2019-07-15 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-07-15 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-07-15 |
Time |
15:53 |
Sent To |
|
|
Notes |
2019-07-15 15:56:42 | REDLINED PER CONTRACTOR INSTRUCTIONS | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2019-07-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-07-05 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-07-05 |
Time |
09:17 |
Sent To |
|
|
Notes |
2019-07-05 09:24:08 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | COMMENTFROM PREVIOUS LIST: | | | | 1. WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE | | NOTE PAGE 13 OF 20, FACTORS APPLY DEPENDING ON | | SUBSTRATE, EDGE DISTANCE AND FASTENER. FOR FASTENER, IF | | USING TAPCON, BE SPECIFIC AS TO WHICH TAPCON (TAPCON | | W/ADVANCED THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR). | | | | 2ND REVIEW, THE .9 FACTOR WAS NOT APPLIED TO THE 12" | | ANCHOR SPACING FOR TAPCON W/ADVANCED THREDFORM | | TECHNOLOGY FASTENER. | | | | ALSO NOTE THAT ANCHOR TYPES A, D, U ARE SPECIFIED ON | | THE INSTALLATION SCHEDULE BUT A, H AND D ARE | | HIGHLIGHTED; PLEASE CORRELATE. | | | | 2. YOU MAY RESUBMIT UP TO TWO PAGES, ALONG WITH A | | COMPLETED RESUBMITTAL FORM, VIA EMAIL TO | | [email protected]. THE EMAIL SHOULD INCLUDE THE PERMIT | | NUMBER AND "RESUBMITTAL" IN THE SUBJECT LINE. THE | | RESUBMITTAL FORM CAN BE FOUND AT THIS WEBSITE: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-06-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-06-21 |
Time |
06:30 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-06-21 |
Time |
06:30 |
Sent To |
|
|
Notes |
2019-06-21 06:31:06 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC R 301, FBC B 1609 COMPLETE THE "SCHEDULE FOR | | INSTALLATION OF OPENING PROTECTIVE DEVICES" OR PROVIDE | | ALL INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS | | EXCEL SPREADSHEET): | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS?PAGE=2 | | | | 2. WHEN COMPLETING THE INSTALLATION SCHEDULE, PLEASE | | NOTE PAGE 13 OF 20, FACTORS APPLY DEPENDING ON | | SUBSTRATE, EDGE DISTANCE AND FASTENER. FOR FASTENER, IF | | USING TAPCON, BE SPECIFIC AS TO WHICH TAPCON (TAPCON | | W/ADVANCED THREADFORM TECHNOLOGY REQUIRES A .9 FACTOR). | | | | PLEASE CONTACT ME IF YOU NEED ASSISTANCE. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-07-05 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-07-05 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-06-25 |
Time |
11:08 |
Sent To |
|
|
Notes |
2019-06-27 11:09:00 | RESUB ROUTED TO BLDG MISC 1 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-06-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-06-21 |
Time |
06:31 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-06-19 |
Time |
15:06 |
Sent To |
|
|
Notes |
|
|
|