2019-07-22 18:40:20 | PLAN |
| REVIEW COMMENTS |
| |
| 1ST REVIEW: FBC SIXTH EDITION (2017) |
| ROBERT MCDOUGAL, CBO |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| (561) 805-6714 |
| [email protected] |
| |
| DENIED BY BUILDING |
| PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| |
| 1) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE |
| EXTERIOR DOOR IS INCOMPLETE. THERE IS NO FL# OR NOA |
| NUMBER LINKED TO THE DRAWINGS. SUBMIT COVERSHEET WITH |
| THE PRODUCT APPROVAL NUMBERS AND ANY OTHER APPROVAL |
| DOCUMENTS FOR THE MASONITE DOOR. FBC 107.3.4 - PROVIDE |
| TWO SETS OF PRODUCT APPROVALS FOR THOSE PRODUCTS WHICH |
| ARE REGULATED BY FAC 61G20-3.001 PER FLORIDA STATUTE |
| 553.842 (5) THAT HAVE BEEN REVIEWED AND APPROVED IN |
| WRITING BY THE DESIGNER OF RECORD. PROVIDE TWO COMPLETE |
| PRODUCT APPROVALS WITH FL OR NOA NUMBERS INCLUDING |
| INSTALLATION INSTRUCTIONS AND MAXIMUM DESIGN PRESSURES |
| FOR EACH OF THE DIFFERENT ROOFING MATERIALS, WINDOW |
| (GLASS TYPES), STRUCTURAL MULLIONS AND EXTERIOR DOOR |
| TYPES. |
| |
| 2) GENERAL NOTE 3 ON SHEET 1 OF THE DRAWINGS FOR THE |
| MASONITE OUTSWING DOOR STATES THAT AN IMPACT PROTECTION |
| SYSTEM IS REQUIRED FOR THIS DOOR. SUBMIT PRODUCT |
| APPROVALS FOR THE STORM PROTECTION DEVICES THAT WILL BE |
| INSTALLED. FBC - R 301.2.1.2 SUBMIT TWO COPIES OF AN |
| INSTALLATION SCHEDULE AND KEY PLAN FOR THE STORM |
| PANELS. SPECIFY THE OPENING SIZE, THE WIND PRESSURES, |
| TYPE OF ANCHOR, ANCHOR SPACING, EDGE DISTANCE, PANEL |
| LENGTH, PANEL SPAN, SEPARATION DISTANCE FROM PANEL TO |
| GLASS AND THE APPLICABLE SECTION NUMBER FROM THE |
| INSTALLATION DRAWINGS. I HAVE INCLUDED A LINK TO THE |
| CONSTRUCTION SERVICES DEPARTMENT SITE THAT HAS MANY OF |
| THE RELATED FORMS INCLUDING |
| THE SCHEDULE FOR INSTALLATION OF OPENING PROTECTIVE |
| DEVICES. |
| HTTP://WPB.ORG/DEVELOPMENT/FORMS-AND-PUBLICATIONS/ |
| |
| 3) THE OWNER/AGENT IS REQUIRED TO SIGN AND DATE THE |
| ENERGY CONSERVATION FORM R402-2017. FBC ENERGY |
| CONSERVATION SECTION R103.1.1.2 |
| |
| 4) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A |
| RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE |
| CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT |
| CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE |
| PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND |
| KEEP THEM WITH THE SUBMITTALS. |