Plan Review Details - Permit 19060740
Plan Review Stops For Permit 19060740
Review Stop G GAS REVIEW
Rev No 2 Status P Date 2019-08-03 Cont ID  
Sent By abelisle Date 2019-08-03 Time 11:18 Rev Time 0.00
Received By abelisle Date 2019-08-03 Time 11:18 Sent To I
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-06-19 Cont ID  
Sent By thunt Date 2019-06-19 Time 16:06 Rev Time 0.00
Received By thunt Date 2019-06-19 Time 16:06 Sent To  
Notes
2019-06-19 16:12:16GAS 1ST REVIEW**DENIED**
  
 1- PROVIDE PAGE #9 OF THE INSTALLATION MANUAL SHOWING
 REQUIRED DISTANCE FROM ANY DOOR OR WINDOW. SUBMIT TWO
 COPIES OF A HOUSE PLAN SHOWING THE LOCATION OF THE
 TANKLESS WATER HEATER AND THE LOCATION AND DISTANCE OF
 ANY OPERABLE DOORS OR WINDOWS IN RELATION TO THE WATER
 HEATER. THE LOCATION OF THE WATER HEATER SHALL COMPLY
 WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE
 HOUSE PLAN CAN BE HAND DRAWN. WPB AMEND. TO FBC SEC.
 107.2.1.
  
 2- VALUE APPEARS LOW. PROVIDE A SIGNED BONA FIDE
 CONTRACT. VALUE SHALL INCLUDE ALL COST INCLUDING TANK
 LESS WATER HEATER. WPB AMEND 109.3
  
 3- CITY RECORDS # 14060789 SHOWS EXISTING SYSTEM .LIST
 THE BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD
 ON THE SYSTEM. REFER TO THE 2017 FBC-FUEL GAS
 SECS.401.8, 402.2, AND TABLES 402.4 (1) THRU 402.4 (37)
 OR 2017 FBC-RES. SEC. G2413.3, G2413.4 AND TABLES
 G2413.4 (1 ) THROUGH G2413.4 (21).
  
 4- SHOW THE LOCATION OF ALL MP (STEP-DOWN) REGULATORS.
 A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY
 AHEAD OF EACH MP REGULATOR. 2017 FBC-FUEL GAS
 SEC.409.4, FBC-RESIDENTIAL SEC. G 2420.4.
  
 5- SUBMIT MANUFACTURER?S SPECIFICATIONS FOR THE
 PRESSURE REGULATORS. REGULATORS INSTALLED ON THE
 EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OUTDOOR
 INSTALLATION. 2014 FGC SEC.410.1, 2017 FBC-RES. SEC.
 G2421.1.
  
 6- SHOW THE DISTANCE FROM THE 2 PSI REGULATOR TO THE
 APPLIANCE. COMPLY WITH 2017 FBC-FUEL GAS SEC. 402.4.1
 OR 2017 FBC-RES. SEC. G2413.4.1, G2413.4.2 FOR THE
 PROPER PIPE SIZE AND BTU LOAD.
  
 7- PLAN CALLS OUT FOR 55? OF NEW PIPING BUT THE SIZING
 CHART PROVIDED CALLS OUT 125?. PLEASE CLARIFY FBC
 107.2.1
  
 8- PLAN CALLS OUT FOR ?? P.E PIPING FOR SIZING CHART
 PROVIDED IS CALLING OUT 1?. PLEASE CLARIFY. FBC 107.2.1
  
 9) PROVIDE ENERGY U.E.F RATING OF THIS TANKLESS SHOWING
 IT MEETS FEDERAL MIN STANDARDS. FBC 107.3.5
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-08-04 Cont ID  
Sent By cpuell Date 2019-08-04 Time 08:48 Rev Time 0.00
Received By cpuell Date 2019-07-30 Time 13:27 Sent To  
Notes
2019-07-31 13:27:25RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-06-19 Cont ID  
Sent By thunt Date 2019-06-19 Time 16:13 Rev Time 0.00
Received By thunt Date 2019-06-17 Time 14:24 Sent To  
Notes
2019-06-18 14:24:50PLUMB <5K

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-08-03 Cont ID  
Sent By abelisle Date 2019-08-03 Time 11:18 Rev Time 0.00
Received By abelisle Date 2019-08-03 Time 11:17 Sent To I
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-06-19 Cont ID  
Sent By thunt Date 2019-06-19 Time 16:12 Rev Time 0.00
Received By thunt Date 2019-06-19 Time 16:12 Sent To  
Notes
2019-06-19 16:13:49PLUMBING 1ST REVIEW**DENIED**
  
 1) PROVIDE MATERIAL BEING USED AND TOTAL DISTANCE OF
 NEW PIPING TO NEW TANKLESS WATER HEATER. FBC 107.2.1
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
 [email protected]