Plan Review Details - Permit 19060680
Plan Review Stops For Permit 19060680 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2019-07-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-07-18 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-07-18 |
Time |
11:25 |
Sent To |
|
|
Notes |
2019-07-18 11:26:55 | MET WITH CONTRACTOR AND SAMANTHA HILL. ENGINEER | | ORIGINAL LETTER WAS FILED WITH CITY FILENET. JG. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2019-06-25 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-06-25 |
Time |
17:34 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-06-25 |
Time |
17:23 |
Sent To |
|
|
Notes |
2019-06-25 17:24:14 | RESIDENTIAL (R3) RE-ROOF, SECOND BUILDING REVIEW | | CHECKLIST. | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | ORIGINAL COMMENT: | | 1- RAS 117 CALCULATIONS DONE BY TERRENCE E. LUNN NEED | | TO BE REVISED. ACCORDING TO SEC. R301.2.1.4 | | FBC-RESIDENTIAL THIS BUILDING IS LOCATED IN EXPOSURE | | "C" NOT EXPOSURE "B". REVISE AS REQUIRED OR PROVIDE | | ENGINEERING ANALYSIS AS ALLOWED BY THE EXCEPTION OF | | SEC. R301.2.1.4 FBC-RESIDENTIAL. | | | | RESPONSE: | | A) REVISED RAS 117 CALCULATIONS DON'T HAVE AN ORIGINAL | | ENGINEER'S SEAL AND SIGNATURE AS REQUIRED BY CHAPTER | | 471 F.S. WHEN SUBMITTING CALCULATIONS/DOCUMENTS FOR | | PUBLIC RECORDS. CALCULATIONS SUBMITTED SHOW WHAT LOOKS | | LIKE A COPY OF THE ENGINEER'S SEAL AND SIGNATURE. NEED | | ORIGINALS. | | | | B) IT LOOKS LIKE THERE IS A TYPO ON THE REVISED | | CALCULATIONS SUBMITTED. THE FIRST PARAGRAPH OF LETTER | | SUBMITTED STATES EXPOSURE CATEGORY C BUT SECOND | | PARAGRAPH STATES EXPOSURE CATEGORY B. REVISE AS | | REQUIRED TO MATCH. SEC. R301.2.1.4 FBC-RESIDENTIAL AND | | SEC. 107.2.1 CITY AMENDMENTS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-06-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-06-14 |
Time |
18:27 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-06-14 |
Time |
18:04 |
Sent To |
|
|
Notes |
2019-06-14 18:27:15 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | NOTE: ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE FLORIDA BUILDING CODE, BUILDING. | | SEC. 801.3 FBC-EXISTING BUILDING. | | | | 1- RAS 117 CALCULATIONS DONE BY TERRENCE E. LUNN NEED | | TO BE REVISED. ACCORDING TO SEC. R301.2.1.4 | | FBC-RESIDENTIAL THIS BUILDING IS LOCATED IN EXPOSURE | | "C" NOT EXPOSURE "B". REVISE AS REQUIRED OR PROVIDE | | ENGINEERING ANALYSIS AS ALLOWED BY THE EXCEPTION OF | | SEC. R301.2.1.4 FBC-RESIDENTIAL. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
N |
Date |
2019-06-25 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-06-25 |
Time |
17:23 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-06-25 |
Time |
17:23 |
Sent To |
|
|
Notes |
2019-06-25 17:23:43 | FLAT ROOFS ONLY. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-07-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-07-18 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-07-18 |
Time |
11:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-06-25 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-06-25 |
Time |
17:43 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-06-24 |
Time |
14:49 |
Sent To |
I |
|
Notes |
2019-06-25 14:49:43 | RESUB ROUTED TO JGOMEZ |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-06-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-06-14 |
Time |
18:28 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-06-14 |
Time |
12:03 |
Sent To |
I |
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy