Plan Review Stops For Permit 19060058 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-07-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-07-09 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-07-09 |
Time |
10:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2019-06-18 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-06-18 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-06-18 |
Time |
15:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2019-06-13 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-06-13 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-06-13 |
Time |
15:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2019-07-01 |
|
|
Cont ID |
|
Sent By |
sathomas |
Date |
2019-07-01 |
Time |
00:00 |
Rev Time |
0.00 |
Received By |
sathomas |
Date |
2019-07-01 |
Time |
00:00 |
Sent To |
P |
|
Notes |
2019-07-01 09:28:42 | PROVISO: | | UPDATE THE CODE LIST TO REFERENCE THE 6TH EDITION OF | | THE FLORIDA FIRE PREVENTION CODE, WHICH CONTAINS THE | | 2015 EDITION OF BOTH NFPA 1 & 101 WITH FLORIDA | | AMENDMENTS. | | | | S. THOMAS | | 561-804-4728 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2019-06-10 |
|
|
Cont ID |
|
Sent By |
sathomas |
Date |
2019-06-10 |
Time |
00:00 |
Rev Time |
0.00 |
Received By |
sathomas |
Date |
2019-06-10 |
Time |
00:00 |
Sent To |
E |
|
Notes |
2019-06-10 11:06:55 | PROVISO: | | | | UPDATE THE CODE LIST TO REFERENCE THE 6TH EDITION OF | | THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE | | 2015 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA | | AMENDMENTS. | | | | S. THOMAS | | 561-804-4728 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-07-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-07-09 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-06-25 |
Time |
07:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-06-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-06-20 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-06-04 |
Time |
13:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2019-06-18 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-06-18 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-06-18 |
Time |
15:36 |
Sent To |
|
|
Notes |
2019-06-18 17:01:39 | NO CHANGE IN OCCUPACNY OR SQ. FOOTAGE. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2019-06-13 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-06-13 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-06-13 |
Time |
09:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2019-07-08 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-07-08 |
Time |
12:20 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-07-08 |
Time |
12:20 |
Sent To |
|
|
Notes |
2019-07-08 12:21:13 | SUB PLUMBING PERMIT REQUIRED |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-06-12 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-06-12 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-06-12 |
Time |
14:17 |
Sent To |
|
|
Notes |
2019-06-12 14:18:15 | PLUMBING 1ST REVIEW**DENIED** | | | | | | 1) PLUMBING PERMIT APPLICATION IS REQUIRED. FBC 105.1 | | | | 2) PROVIDE ACCESSIBILITY DETAISL FOR THE COUNTER TOP | | SHOWING IT COMPLIES WITH CLEAR FLOOR, TURNING SPACE, | | AND REACH RANGES/ FBC-ACC 305, 308.2 | | | | 3) PROVIDE LOCATION ON PLAN AS TO WHERE THE ACCESSIBLE | | RESTROOMS ARE LOCATED. FBC 107.2.1 | | | | TIM HUNT | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | CITY OF WEST PALM BEACH | | 561-248-2703 | | [email protected] | | [email protected] |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2019-07-09 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-07-09 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-07-09 |
Time |
10:19 |
Sent To |
|
|
Notes |
2019-07-09 10:22:27 | PROVISO: MEP ENGINEER TO OBTAIN 3RD PARTY DIGITAL | | SIGNATURE | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2019-06-13 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-06-13 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-06-13 |
Time |
15:09 |
Sent To |
|
|
Notes |
2019-06-17 15:55:28 | ****CORRECTIONS**** | | ****REVISED 6/21**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | MEP PAGES DIGITAL SIGNATURES ARE SELF-SIGNED | | CERTIFICATES AND LACK 3RD PARTY VERIFICATION, | | FAC61G15-23.004(2)(B). PLEASE PROVIDE 3RD PARTY ISSUED | | DIGITAL SIGNATURES FOR ENGINEER ON PAGES THAT ARE | | RESUBMITTED DUE TO CODE COMMENTS OR DESIGN CHANGES. | | ALSO INCLUDE THE LANGUAGE REQUIRED FOR DIGITALLY SIGNED | | PLANS AND A SEAL (SEAL IMAGE OR STATEMENT "SIGNED AND | | SEALED" OK). | | | | | | | | | | | | | | | | | | | 2019-06-13 15:09:18 | ELECTRICAL PLANS HAVE A DIGITAL SIGNATURE, BUT THE | | DIGITAL SIGNATURE DOES NOT INCLUDE THE STATEMENT | | "SIGNED AND SEALED" AS PER FAC 61G15-23.004. THE | | SIGNATURE ONLY STATES THAT IT IS SIGNED. PROVIDE | | CORRECTION. WPB FBC 107.2.1 | | | | | 2019-06-13 09:19:43 | MECHANICAL SHEETS ARE ELECTRONICALLY SIGNED BUT NOT | | SEALED- SECTION 61G1523.005 FAC. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2019-07-05 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2019-07-05 |
Time |
13:50 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2019-07-05 |
Time |
13:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2019-06-20 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2019-06-20 |
Time |
11:34 |
Rev Time |
0.25 |
Received By |
eschneid |
Date |
2019-06-20 |
Time |
11:34 |
Sent To |
|
|
Notes |
2019-06-20 11:41:58 | FAILED | | | | 1) THE PROJECT LOCATION MAP ON THE COVER SHEET | | INDICATES THAT THIS PERMIT IS FOR A BUILDING WITHIN THE | | SCHUMACHER DEALERSHIP AREA (WEST OF PALM BEACH LAKES | | BLVD.), NOT AT 2901 OKEECHOBEE. | | | | 2) PROVIDE A SITE PLAN SHOWING WHERE ON THE PROPERTY | | THE WORK IS LOCATED. | | | | 3) IT APPEARS THAT THE PROPOSED WORK MEETS ZONING | | REQUIREMENTS. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | [email protected] |
|
|