Plan Review Details - Permit 19060037
Plan Review Stops For Permit 19060037 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2019-07-29 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-07-29 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-07-29 |
Time |
15:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2019-07-15 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-07-15 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-07-15 |
Time |
09:50 |
Sent To |
|
|
Notes |
2019-07-15 10:02:32 | ***CORRECTIONS*** | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 3RD BUILDING REVIEW DENIED: | | | | FBC B 107. THE SUBMITTED PRODUCT APPROVALS DO NOT | | PROVIDE AN ENHANCED FASTENING PATTERN FOR THE ANCHORING | | OF THE BASE SHEET AT CORNER AND PERIMETER AREAS. | | | | THE ANCHOR SPACING PROVIDED IN THE PRODUCT APPROVALS | | (12" O.C.) APPEARS TO BE FOR THE FIELD SECTIONS OF | | ROOF. | | | | PLEASE PROVIDE AN ENHANCED BASE SHEET ANCHOR SPACING | | FOR AREA PRESSURES (CORNER -95.7) AND (PERIMETER | | -63.6). | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2019-06-21 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-06-21 |
Time |
11:54 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-06-21 |
Time |
11:54 |
Sent To |
|
|
Notes |
2019-06-21 11:56:03 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. INDICATE WHICH APPROVED ASSEMBLY IS PROPOSED, FBC R | | 301. IF THE DESIGN PRESSURE DOES NOT MEET THE | | REQUIREMENT FOR ZONES 2 AND 3 (-63.6, -95.7), | | ENGINEERING FOR ENHANCED FASTENING IS REQUIRED, SEE | | GENERAL LIMITATION #7. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-06-03 |
|
|
Cont ID |
|
Sent By |
jduprey |
Date |
2019-06-03 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
jduprey |
Date |
2019-06-03 |
Time |
14:49 |
Sent To |
HIST |
|
Notes |
2019-06-03 14:57:26 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | JOSEAN A. DUPREY | | BUILDING PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6716 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PLEASE CLARIFY THE SCOPE OF WORK. THE APPLICATIO | | INDICATES "RE-ROOF FLAT DECK" HOWEVER THE PRODUCTS | | SUBMITTED ARE FOR UNDERLAYMENT AND TILE. PLEASE | | INDICATE CLEARLY THE SCOPE OF WORK AND PROVIDE THE | | PRODUCTS APPROVALS. FBC 107 |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2019-06-04 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2019-06-04 |
Time |
12:12 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2019-06-04 |
Time |
12:12 |
Sent To |
|
|
Notes |
2019-06-04 12:12:33 | FOR FLAT ROOF ONLY |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-07-29 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-07-29 |
Time |
15:56 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-07-23 |
Time |
13:55 |
Sent To |
|
|
Notes |
2019-07-24 13:55:35 | RESUB ROUTED TO PVALENTI |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-07-15 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-07-15 |
Time |
10:07 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-07-11 |
Time |
14:38 |
Sent To |
|
|
Notes |
2019-07-12 14:38:21 | RESUB ROUTED TO SHILL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-06-04 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2019-06-04 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2019-06-03 |
Time |
14:10 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |