Plan Review Details - Permit 19060008
Plan Review Stops For Permit 19060008 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-10-01 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-10-01 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-10-01 |
Time |
11:31 |
Sent To |
|
|
Notes |
2019-10-01 11:33:43 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | APPROVED THROUGH RESUBMITTAL UNDER PERMIT #19070664. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-06-06 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-06-06 |
Time |
09:02 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-06-06 |
Time |
09:02 |
Sent To |
|
|
Notes |
2019-06-06 09:31:26 | ***CORRECTIONS*** | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | BUILDING PLAN REVIEW DENIED: | | | | 1. FBC B 107.2.1 A SURVEY IS REQUIRED WITH SET BACK | | MEASUREMENTS. | | 2. FBC R 311.2 THE SIZE OF DOOR (CLEAR WIDTH) NEEDS TO | | BE AT A MINIMUM OF 32". THE DOOR SCHEDULE INDICATES A | | DOOR WIDTH OF 30". | | 3. FBC B 107.2.1 THE RAMP FOOTING REINFORCEMENT DETAILS | | ARE REQUIRED. PLEASE PROVIDE DETAILS. | | 4. FBC B 107.2.1 THE RAMP FRAMING, DECKING, AND | | HANDRAIL CONNECTION AND FASTENER DETAILS ARE REQUIRED. | | PLEASE PROVIDE DETAILS. | | | | NOTE: A. THE WINDOW OPENING SIZE REQUIREMENTS FOR | | BEDROOM EGRESS MUST REMAIN IN PLACE AND CAN NOT BE | | COMPROMISED BY THE RAMP. | | B. THE ENTRY DOOR AND LANDING ORIENTATION MAY NEED TO | | BE ADJUSTED TO PROVIDE BETTER MANEUVERING CLEARANCE. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-06-06 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-06-06 |
Time |
09:31 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-06-03 |
Time |
15:44 |
Sent To |
|
|
Notes |
2019-06-04 15:44:31 | REVISION ROUTED TO ZONING INBOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2019-06-05 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2019-06-05 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2019-06-05 |
Time |
13:47 |
Sent To |
B |
|
Notes |
2019-06-05 13:55:08 | ZONING REVIEW FAILED, DUE TO THE FOLLOWING: | | | | 1) PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH | | INCLUDES THE PROPERTY?S ADDRESS AND LEGAL DESCRIPTION. | | 2) PURSUANT TO SEC. 94-305(B)(2) - STRUCTURAL | | INTRUSIONS. STRUCTURAL OVERHANGS, INCLUDING BUT NOT | | LIMITED TO BALCONIES, CORNICES, GUTTERS, EAVES, AND | | ROOF OVERHANG PROJECTIONS SHALL NOT EXTEND FARTHER THAN | | THREE FEET INTO ANY SETBACK. | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | GENERATE ADDITIONAL COMMENTS. | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | PLANNING DEPARTMENT WEBSITE AT | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | CONTACT ME. IF YOU WANT TO MEET IN PERSON TO GO OVER | | THE ABOVE COMMENTS, PLEASE CALL OR E-MAIL ME TO | | SCHEDULE AN APPOINTMENT. | | | | MAGGIE CRUZ | | ASSOCIATE PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: 561-822-1442 | | E-MAIL: [email protected] | | |
|
|
|