Plan Review Details - Permit 19051244
Plan Review Stops For Permit 19051244
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-06-21 Cont ID  
Sent By jleahy Date 2019-06-21 Time 08:30 Rev Time 0.00
Received By abelisle Date 2019-08-03 Time 06:05 Sent To  
Notes
2019-06-21 08:31:00REVIEW DONE UNDER THE ELECTRICAL REVIEW JL

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-06-21 Cont ID  
Sent By jleahy Date 2019-06-21 Time 08:31 Rev Time 0.00
Received By jleahy Date 2019-06-21 Time 08:31 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2019-07-01 Cont ID  
Sent By thunt Date 2019-07-01 Time 15:26 Rev Time 0.00
Received By thunt Date 2019-07-01 Time 15:26 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-06-04 Cont ID  
Sent By thunt Date 2019-06-04 Time 07:45 Rev Time 0.00
Received By thunt Date 2019-06-04 Time 07:45 Sent To  
Notes
2019-06-04 07:51:29GAS 1ST REVIEW**DENIED**
  
 1) YOUR SURVEY CALLS OUT A #1 POUND SYSTEM BUT DO NOT
 SHOWN OR HAVENT PROVIDE SIZING CHARTS FOR THAT PRESSURE
 SYSTEM. PLEASE CLARIFY. FBC 107.2.1
  
 2) GENERATOR IS 312,000 BTU'S PER THE INSTALLATION
 MANUAL AND NOT 240,00 BTU'S AS CALLED OUT ON YOUR PLAN.
 BASED ON THE SIZING CHART PROVIDED 402.4 (1) MAX
 PERMITTED BTU'S WOULD BE 273,000 BTU'S. FBC 107.2.1
  
 3) PROVIDE PIPE SIZE WHERE YOU PLAN ON CONNECTING INTO
 THE EXISTING GAS SYSTEM. FBC 107.3.5
  
 4) YOU PROVIDED PRESSURE REGULATOR SPEC BUT DO NOT SHOW
 SYSTEM AS 2 PSI OR ADDING TO THE EXISTING EQUIPMENT.
 PLEASE CLARIFY AND CALL OUT THE PSI OF THE EXISTING
 SYSTEM. FBC 107.3.5
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-07-01 Cont ID  
Sent By thunt Date 2019-07-01 Time 15:27 Rev Time 0.00
Received By thunt Date 2019-06-26 Time 15:16 Sent To  
Notes
2019-06-27 15:17:04RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-06-21 Cont ID  
Sent By jleahy Date 2019-06-21 Time 08:31 Rev Time 0.00
Received By jleahy Date 2019-05-23 Time 13:20 Sent To  
Notes
2019-05-24 13:21:08ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 1 Status P Date 2019-05-30 Cont ID  
Sent By mcruz Date 2019-05-30 Time 16:44 Rev Time 0.00
Received By mcruz Date 2019-05-30 Time 16:43 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved