Plan Review Details - Permit 19050775
Plan Review Stops For Permit 19050775
Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-05-29 Cont ID  
Sent By ppetty Date 2019-05-29 Time 06:14 Rev Time 0.00
Received By fgiaquin Date 2019-05-29 Time 05:47 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2019-06-11 Cont ID  
Sent By thunt Date 2019-06-11 Time 16:47 Rev Time 0.00
Received By thunt Date 2019-06-11 Time 16:47 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2019-06-05 Cont ID  
Sent By thunt Date 2019-06-05 Time 14:54 Rev Time 0.00
Received By thunt Date 2019-06-05 Time 14:54 Sent To  
Notes
2019-06-05 14:59:41GAS REVISION #2 DENIED**
  
  
 PLAN IS STAMPED APPROVED AND MAY BE ISSUED ONCE JOE
 SPASOVSKI. P.E COMES INTO THE BUILDING DEPARTMENT AND
 SIGN'S BOTH SHT P-1. PLAN SUBMITTED ARE COPIES OF HIS
 SEAL AND SIGNATURE. F.S 471
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
 [email protected]

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-05-20 Cont ID  
Sent By thunt Date 2019-05-20 Time 15:19 Rev Time 0.00
Received By thunt Date 2019-05-20 Time 15:19 Sent To  
Notes
2019-05-20 15:20:40PLUMBING 1ST REVISION REVIEW**DENIED**
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 1) PROVIDE MAKE UP AIR FOR THE FIRE PLACE AND RANGE AS
 THE BTU'S HAVE INCREASED FROM EXISTING . 2017 FBC-FUEL
 GAS SEC.304.9.3 OR FBCR G2407.9.3.
  
 2) PROVIDE TANKLESS WATER HEATER AND GAS VENT PIPE
 INSTALLATION MANUAL. FBC 107.2.1
  
 3) PROVIDE DISTANCE THAT THE TANKLESS VENT PIPING IS
 AWAY FROM ANY DOOR OR WINDOW THAT OPEN AND AWAY FROM
 ANY MECHANICAL MAKE UP AIR VENT. FBC 107.2.1
  
  
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-06-11 Cont ID  
Sent By thunt Date 2019-06-11 Time 16:48 Rev Time 0.00
Received By thunt Date 2019-06-10 Time 14:05 Sent To  
Notes
2019-06-11 14:05:46RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-06-05 Cont ID  
Sent By thunt Date 2019-06-05 Time 14:59 Rev Time 0.00
Received By thunt Date 2019-06-03 Time 15:37 Sent To  
Notes
2019-06-04 15:37:12RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-05-29 Cont ID  
Sent By fgiaquin Date 2019-05-29 Time 06:14 Rev Time 0.00
Received By fgiaquin Date 2019-05-15 Time 10:03 Sent To  
Notes
2019-05-17 10:03:53REVISION ROUTED TO GJOHNSON

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-05-25 Cont ID  
Sent By cmontell Date 2019-05-25 Time 08:19 Rev Time 0.00
Received By cmontell Date 2019-05-25 Time 08:19 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-05-20 Cont ID  
Sent By gjohnson Date 2019-05-20 Time 15:19 Rev Time 0.00
Received By thunt Date 2019-05-20 Time 15:19 Sent To  
Notes
***NONE***