Plan Review Details - Permit 19050699
Plan Review Stops For Permit 19050699 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-07-16 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2019-07-16 |
Time |
08:37 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2019-07-16 |
Time |
08:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-05-21 |
|
|
Cont ID |
|
Sent By |
jduprey |
Date |
2019-05-21 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
jduprey |
Date |
2019-05-20 |
Time |
16:48 |
Sent To |
E |
|
Notes |
2019-05-21 08:57:12 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | JOSEAN A. DUPREY | | BUILDING PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6716 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE | | OF WORK. THE PERMIT VALUATION AND PERMIT FEE MUST BE | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | CONTRACTOR WOULD PROVIDE. YOU MAY PROVIDE A COPY OF THE | | CONTRACT SIGNED BY THE OWNER OR A LIST OF LABOR, | | MATERIALS AND EQUIPMENT RENTAL TO VERIFY VALUE. CITY OF | | WPB CHAPTER 109.3 | | | | 2. SEPARATE ROOF PERMIT IS REQUIRED. SUBMIT ROOF | | PRODUCT APPROVALS WITH PERMIT. FBC 105 | | | | 3. PROVIDE ENGINEERED TRUSS SHOP DRAWINGS TO THE FIELD | | INSPECTOR. FBC 107 | | | | 4. PROVIDE WATER-RESISTIVE BARRIER TO THE NEW FACADE | | WALLS PER FBC 2510.6 | | | | 5. PROVIDE DOORS AND WINDOW DEFERRED SUBMITTALS | | APPROVED BY THE DESIGNER OF RECORD. FBC 107.3.4.2 | | | | 6. IN REGARDS THE NEW REAR FACADE WINDOW OPENINGS, NO | | STRUCTURAL DETAIL WAS PROVIDED FOR THE JAM. THE | | DRAWINGS STATE THIS IS AN EXISTING CMU WALL, HOWEVER IS | | THESE ARE HOLLOW BLOCKS, ARE GOING TO BE FILL WITH | | GROUT, IS A NEW REBAR GOING IN? PLEASE SPECIFY. FBC 107 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2019-07-14 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-07-14 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-07-14 |
Time |
14:17 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-05-27 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-05-27 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-05-27 |
Time |
10:41 |
Sent To |
I |
|
Notes |
2019-05-27 10:41:50 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | SEALED BY THE PERSON RESPONSIBLE FOR THE DESIGN. WPB | | FBC 107.2.1, 107.3.5; FS 471, 481 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2019-05-20 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2019-05-20 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2019-05-20 |
Time |
|
Sent To |
B |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-07-16 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2019-07-16 |
Time |
08:38 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2019-07-11 |
Time |
15:56 |
Sent To |
|
|
Notes |
2019-07-12 15:56:15 | RESUB ROUTED TO JPEARSON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-05-27 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-05-14 |
Time |
13:53 |
Sent To |
|
|
Notes |
2019-05-15 13:53:38 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2019-05-17 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2019-05-17 |
Time |
09:31 |
Rev Time |
1.00 |
Received By |
eschneid |
Date |
2019-05-17 |
Time |
09:31 |
Sent To |
ENG |
|
Notes |
2019-05-17 11:46:52 | PASSED | | | | 1) DUMPSTER ENCLOSURES REQUIRES A SEPARATE PERMITS WITH | | PLANS. | | | | 2) AWNINGS REQUIRE SEPARATE PERMITS WITH PLANS. | | | | 3) THE RECONFIGURED LANDSCAPE REQUIRES A SEPARATE | | PERMIT WITH PLANS | | | | 4) PLEASE NOTE THAT THE RECONFIGURED PARKING SHOWN AS | | "EXISTING" IS ACTUALLY THE PROPOSED CONFIGURATION OF | | THE PARKING AREA. THIS REQUIRES A SEPARATE PERMIT, WITH | | PLANS. | | | | |
|
|
|