Plan Review Details - Permit 19050449
Plan Review Stops For Permit 19050449 |
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-05-17 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-05-17 |
Time |
16:14 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-05-16 |
Time |
14:29 |
Sent To |
|
|
Notes |
2019-05-17 14:29:29 | RESUB ROUTED TO DBATTLES |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-05-09 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-05-09 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-05-09 |
Time |
15:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2019-05-17 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-05-17 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-05-17 |
Time |
16:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2019-05-09 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-05-09 |
Time |
15:35 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-05-09 |
Time |
15:35 |
Sent To |
|
|
Notes |
2019-05-09 15:35:47 | ****CORRECTIONS**** | | W.P.B. PERMIT: 19050449 | | REVIEWED: MAY 9, 2019 | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER PX4191 | | [email protected] | | 561-805-6718 | | | | FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017) | | FBC[B] = FBC BUILDING | | FBC[EXISTING] = FBC EXISTING BUILDING | | FBC[A] = FBC ACCESSIBILITY | | FBC[E] = FBC ENERGY CONSERVATION | | FBC[R] = FBC RESIDENTIAL | | | | R905.3 CLAY AND CONCRETE TILE. THE INSTALLATION OF CLAY | | AND | | CONCRETE TILE SHALL BE IN ACCORDANCE WITH THE | | MANUFACTURER?S | | INSTALLATION INSTRUCTIONS. | | -PLEASE PROVIDE THE ALLOWABLE OVERTURNING MOMENT AND | | THE PADDY PLACEMENT ON TABLE 1 IN PRODUCT APPROVAL | | FL6332-R8 | | | | NOTES: | | -THIS IS AN EXPOSURE D | | | | -COMMENTS ARE A BRIEF OVERVIEW OF CODE SECTIONS. | | FURTHER REVIEW OF THE REFERENCED CODE SECTIONS WILL BE | | REQUIRED. | | | | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS | | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) | | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT | | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER | | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" | | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS | | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE | | NEED "VOID", RENDERING THEM NOT USABLE. | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | [email protected] | | | | | | |
|
|
|