Plan Review Details - Permit 19050357
Plan Review Stops For Permit 19050357
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-06-26 Cont ID  
Sent By cthroop Date 2019-06-26 Time 16:16 Rev Time 0.00
Received By cthroop Date 2019-06-26 Time 15:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-05-22 Cont ID  
Sent By cthroop Date 2019-05-22 Time 15:46 Rev Time 0.00
Received By cthroop Date 2019-05-22 Time 08:10 Sent To  
Notes
2019-05-22 16:01:59BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH
 EDITION
 FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 1. UPDATE APPLICABLE CODE ON PLAN PAGE C1 TO 6TH
 EDITION 2017 FBC.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 2. PROVIDE 2 COPIES OF A CURRENT SURVEY.
 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED
 WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY
 A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF
 NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE,
 DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES
 AND THE PROPOSED FINISHED GRADES, DEPICTING THE
 PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD
 AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT
 SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND
 INCLUDED ON A BOUNDARY LINE SURVEY.
  
 3. PROVIDE A SITE DRAINAGE PLAN.
 FBC R401.3 SITE DRAINAGE
 PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING
 COMPLIANCE WITH FBC R401.3.
  
 4. PROVIDE AN ACCURATELY COMPLETED ENERGY SUBMITTAL.
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 5. PROVIDE DESIGN PRESSURES FOR ALL EXTERIOR DOOR
 OPENINGS.
 FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN
 PRESSURES PURSUANT TO FBC-R301.2.
  
 6. PLANS INDICATE THE DEMOLITION OF A SWIMMING POOL.
 SWIMMING POOL REMOVAL REQUIREMENTS HAVE BEEN INCLUDED
 IN YOUR SUBMITTAL.
 APPLICATION PROPOSES DEMOLITION OF A SWIMMING POOL.
 PLEASE PROVIDE A UTILITY RELEASE, CITY OF WEST PALM
 BEACH WATER DEPARTMENT, ON THEIR FORM "DEMOLITION
 APPLICATION" (CROSS OFF THE PORTIONS WHICH REFER TO
 METER PULL, NOTE THIS IS DEMOLITION OF SWIMMING POOL
 ONLY):
 HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B
 UILDING-PERMIT-FORMS
 IF A HYDRANT METER OR BACKFLOW PREVENTER IS DESIRED,
 THEN A PARTIAL RELEASE WILL BE NOTED ON THEIR FORM.
 FAX THE COMPLETED "DEMOLITION APPLICATION" FORM TO
 561-822-2183. AFTER THEY FAX THE RELEASE TO YOU, SEND A
 COPY VIA EMAIL TO [email protected] WITH THE PERMIT
 NUMBER IN THE SUBJECT LINE.
 NOTE THAT THIS PROPERTY DOES NOT HAVE A BACKFLOW
 PREVENTER IN OUR RECORDS AND IT IS NOT CLEAR HOW DUST
 CONTROL WILL BE ACCOMPLISHED.
  
 7. PLANS SPECIFY R-30 SPRAY FOAM INSULATION IN CEILING
 ASSEMBLY. PROVIDE MANUFACTURERS SPECIFICATIONS.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2019-07-08 Cont ID  
Sent By jleahy Date 2019-07-08 Time 16:01 Rev Time 0.00
Received By jleahy Date 2019-07-08 Time 15:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2019-06-18 Cont ID  
Sent By jpearson Date 2019-06-18 Time 15:54 Rev Time 0.00
Received By jpearson Date 2019-06-18 Time 15:54 Sent To  
Notes
2019-06-18 15:27:35CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. THERE IS A CONFLICT BETWEEN THE RISER DIAGRAM AND
 THE PANEL SCHEDULES. IS PANEL B FED FROM PANEL A, OR IS
 IT FED FROM PANEL B DISCONNECT? WHERE IS PANEL B
 DISCONNECT FED FROM? THERE IS CONFLICT ALSO WITH WIRE
 SIZE WITH PANEL A STATING THAT PANEL B IS FED WITH 6
 GAUGE WIRE AND THE RISER STATING THAT IT IS FED WITH 1
 GAUGE WIRE. PROVIDE CLARIFICATIONS AND/OR CORRECTIONS
 AS NEEDED. NEC 215.5; WPB FBC 107.2.1
 2. PROVIDE LOAD CALCULATION FOR PANEL B. IF THIS PANEL
 IS FED WITH LESS THAN A 100 AMP FEEDER, DEMAND FACTORS
 ARE NOT PERMITTED TO BE USED. NEC 220; FBC RE E3602.2
 OR E3701.2 AS APPLICABLE.
 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR
 SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY
 STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR
 THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE
 SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC
 RE E3606.3
 4. PROVIDE GFCI PROTECTION FOR GAS WATER HEATER IGNITOR
 RECEPTACLE. NEC 210.8; FBC RE E3902.3
 5. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC
 210.8(D); FBC RE E3902.10
 6. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE
 OUTLETS IN GARAGE, INCLUDING THE GARAGE DOOR OPENER.
 PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.2
 7. AFCI PROTECTION SHOWN IS NOT CODE COMPLIANT. ALL
 BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15-
 AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY
 ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES,
 DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS,
 HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS
 SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND
 POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH
 AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC
 210.8, 210.12; FBC RE E3902; FBC EX 607.1.1 OR 801.1,
 801.2, OR 901.2 AS APPLICABLE.
 8. THERE ARE TWO SHEETS NAMED E1.0. THE SECOND ONE HAS
 THE PLUMBING RISER ON IT. PROVIDE CORRECTION. WPB FBC
 107.2.1
 9. THE CONDUIT FROM METER CAN TO MAIN SERVICE
 DISCONNECT SHOULD NOT INCLUDE AN EQUIPMENT GROUNDING
 CONDUCTOR. PROVIDE CORRECTION.
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-05-20 Cont ID  
Sent By jleahy Date 2019-05-20 Time 11:25 Rev Time 0.00
Received By jleahy Date 2019-05-20 Time 11:25 Sent To  
Notes
2019-05-20 11:43:57ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PG. E1.0
  
 SEVERAL BEDROOMS HAVE NO SMOKE ALARMS/ CO ALARMS
  
 FOYER MAY NEED OUTLETS PER FBC E3901.11
  
 PENINSULAR OUTLETS IN THE KITCHEN PER FBC E3901.4.3
  
 RISER DIAGRAM SHOWS 300 AMPERE SERVICE BUT WIRE SIZE IS
 ONLY GOOD FOR 150 AMPERES
  
 PANEL SIZE SHOWS 200 AMPERES BEING FED BY A 300 AMPERE
 SWITCH.
  
 PANEL BOARD IDENTIFICATION
 E3706.2PANELBOARD CIRCUIT IDENTIFICATION.
 ALL CIRCUITS AND CIRCUIT MODIFICATIONS SHALL BE LEGIBLY
 IDENTIFIED AS TO THEIR CLEAR, EVIDENT, AND SPECIFIC
 PURPOSE OR USE.
 THE IDENTIFICATION SHALL INCLUDE AN APPROVED DEGREE OF
 DETAIL THAT ALLOWS EACH CIRCUIT TO BE DISTINGUISHED
 FROM ALL OTHERS.
 SPARE POSITIONS THAT CONTAIN UNUSED OVERCURRENT DEVICES
 OR SWITCHES SHALL BE DESCRIBED ACCORDINGLY. THE
 IDENTIFICATION
 SHALL BE INCLUDED IN A CIRCUIT DIRECTORY LOCATED ON THE
 FACE OF THE PANELBOARD ENCLOSURE OR INSIDE THE PANEL
 DOOR. CIRCUITS
 SHALL NOT BE DESCRIBED IN A MANNER THAT DEPENDS ON
 TRANSIENT CONDITIONS OF OCCUPANCY. [408.4(A)]

Review Stop G GAS REVIEW
Rev No 3 Status N Date 2019-07-02 Cont ID  
Sent By thunt Date 2019-07-02 Time 08:30 Rev Time 0.00
Received By thunt Date 2019-07-02 Time 08:30 Sent To  
Notes
2019-07-02 08:30:14A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL
 PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT
 THIS TIME. A SEPARATE GAS PERMIT IS REQUIRED FOR A
 CONTRACTOR TO PERFORM THE RELATED WORK. PROVIDE
 COMPLETE PLANS THAT REFLECT THE ENTIRE SCOPE OF GAS
 WORK TO BE DONE. WPB AMEND. TO FBC SEC.107.2.1.
  
  

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2019-06-26 Cont ID  
Sent By cthroop Date 2019-06-26 Time 16:02 Rev Time 0.00
Received By cthroop Date 2019-06-26 Time 15:20 Sent To  
Notes
2019-06-26 16:03:42BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 A SEPERATE GAS PERMIT IS REQUIRED FOR THIS SCOPE OF
 WORK.

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-05-15 Cont ID  
Sent By thunt Date 2019-05-15 Time 13:09 Rev Time 0.00
Received By thunt Date 2019-05-15 Time 13:09 Sent To  
Notes
2019-05-15 13:10:45GAS 1ST REVIEW**DENIED**
  
 A GAS TANKLESS WATER HEATER IS CALLED OUT ON THE
 R405-2017 ENERGY FORM BUT NO GAS PLAN HAS NOT BEEN
 INCLUDED IN THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW
 HAS NOT BEEN PERFORMED AT THIS TIME. A SEPARATE GAS
 PERMIT IS REQUIRED FOR A CONTRACTOR TO PERFORM THE
 RELATED WORK. PROVIDE COMPLETE PLANS THAT REFLECT THE
 ENTIRE SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC
 SEC.107.2.1.
  
  
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
 [email protected]
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2019-06-27 Cont ID  
Sent By aborngra Date 2019-06-27 Time 08:18 Rev Time 0.00
Received By aborngra Date 2019-06-20 Time 15:03 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2019-05-15 Cont ID  
Sent By aborngra Date 2019-05-15 Time 11:05 Rev Time 0.00
Received By aborngra Date 2019-05-15 Time 09:41 Sent To PC
Notes
2019-05-15 11:05:28THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING
 CONDITION(S):
  
 1. ALL WINDOWS AND DOORS SHALL HAVE CLEAR GLASS OR
 LOW-E GLASS.
 2. ALL WINDOWS SHALL HAVE EXTERNAL DIMENSIONAL PYRAMID
 MUNTINS.
 3. ALL REPLACEMENT WINDOWS SHALL BE SIZED TO FIT THE
 WINDOW FRAME OPENING AND THE LOCATION WITHIN THE WINDOW
 OPENING.
  
 FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER,
 HISTORIC PRESERVATION PLANNER AT [email protected]
 AARON BORNGRABER
 HISTORIC PRESERVATION PLANNER
 CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES
 T: 561-822-1428
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-07-08 Cont ID  
Sent By jleahy Date 2019-07-08 Time 16:01 Rev Time 0.00
Received By jleahy Date 2019-06-28 Time 14:00 Sent To  
Notes
2019-07-01 14:00:16RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-06-26 Cont ID  
Sent By cthroop Date 2019-06-26 Time 16:16 Rev Time 0.00
Received By cthroop Date 2019-06-13 Time 15:54 Sent To  
Notes
2019-06-14 15:55:06R31

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-05-22 Cont ID  
Sent By cthroop Date 2019-05-22 Time 16:20 Rev Time 0.00
Received By cthroop Date 2019-05-07 Time 13:35 Sent To  
Notes
2019-05-08 13:35:57R27

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2019-07-11 Cont ID  
Sent By cthroop Date 2019-07-11 Time 12:39 Rev Time 0.00
Received By cthroop Date 2019-07-11 Time 12:37 Sent To  
Notes
2019-07-11 12:39:34MU-2019-021253-0000. CT

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-05-22 Cont ID  
Sent By cthroop Date 2019-05-22 Time 14:25 Rev Time 0.00
Received By cthroop Date 2019-05-22 Time 08:10 Sent To  
Notes
2019-05-22 14:26:48PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL
 (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE
 PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE
 RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS
 APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE
 FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD
 MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-06-26 Cont ID  
Sent By cthroop Date 2019-06-26 Time 16:16 Rev Time 0.00
Received By cthroop Date 2019-06-26 Time 15:21 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-05-22 Cont ID  
Sent By cthroop Date 2019-05-22 Time 16:02 Rev Time 0.00
Received By cthroop Date 2019-05-22 Time 08:10 Sent To  
Notes
2019-05-22 16:13:15MECHANICAL PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 BUILDING PLANS EXAMINER, PX3169
 1&2 FAMILY PLANS EXAMINER, SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH
 EDITION
 FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 1. PROVIDE AN ACCURATELY COMPLETED ENERGY SUBMITTAL.
 CEILING INSULATION VALUE ON ENERGY SUBMITTAL DOES NOT
 MATCH APPROVED DESIGN.
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 2. PLAN SHOWS 3 SYSTEMS, ENERGY SUBMITTAL SHOWS 1
 SYSTEM. PLEASE CLARIFY.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 3. ENERGY SUBMITTAL SPECIFIES GAS FUELED TANKLESS WATER
 HEATER. PLANS SPECIFY ELECTRIC WATER HEATER. PLEASE
 CLARIFY.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 4. PROVIDE PRODUCT APPROVAL FOR CU TIE-DOWN.
 FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE CU TIE-DOWN SUBMITTALS.
  
 5. MECHANICAL PLAN M.1 DOES NOT SHOW LOCATION OF CU #2
 AND CU #3. PLEASE CLARIFY.
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED.
  
  
  
  
  
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2019-07-02 Cont ID  
Sent By thunt Date 2019-07-02 Time 08:30 Rev Time 0.00
Received By thunt Date 2019-07-02 Time 06:34 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2019-06-17 Cont ID  
Sent By thunt Date 2019-06-17 Time 14:41 Rev Time 0.00
Received By thunt Date 2019-06-17 Time 13:49 Sent To  
Notes
2019-06-17 14:32:08PLUMBING 2ND REVIEW**DENIED**FL ST 553.80 (B)2BWITH
 RESPECT TO EVALUATION OF DESIGN PROFESSIONALS?
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
  
  
 1) 2ND REQUEST.A GAS TANKLESS WATER HEATER IS CALLED
 OUT ON THE R405-2017 FORM LISTED @ .80 E.F. THE FEDERAL
 MIN EFFICIENCY AS OF 12/29/2016 IS .82%. REFER TO
 FEDERAL REGISTER VOL. 81, NO. 250. YOU MUST SUBMIT A
 CORRECTED R405-2017 FORM WITH THE CORRECT E.F. ALSO IT
 IS STILL UNCLEAR IF THE WATER HEATER IS GAS OR ELC
 TANKLESS. PLEASE CLARIFY.
  
 2) ANSWERED
  
 3) ANSWERED
  
 4) 2ND REQUEST. ISOMETRIC DRAWING ON SHT. E1.0 MASTER
 BATHROOM SHOW 2 FIXTURES BEYOND THE ACTUAL VENT. ONLY
 ONE IS PERMITTED IN A WET VENT SYSTEM. FBC-R P3108.2.1
 AND THE FOYER BATH SHALL HAVE EACH WET-VENTED FIXTURE
 CONNECT TO THE HORIZONTALLY BRANCH IS PART OF THE WET
 VENT. FBC-R P3108.1
  
 5) 2ND REQUEST* NOT FULLY ADDRESSED. SHT. E1.0 PANEL
 SCHEDULE SHOWS1 DOUBLE 50 AMP BREAKER FOR THE TANKLESS.
 THE MAX WATER HEATER BASED ON BREAKER WOULD BE A MAX
 11KW. THIS WOULD BE UNDERSIZED FOR THIS HOME. FBC
 107.3.5
  
 6) 2ND REQUEST.PROVIDE COMPLETE INSTALLATION MANUAL FOR
 TANKLESS WATER HEATER TO INCLUDE HEAT RISE CHARTS. FBC
 107.2.1. THE WATER HEATER TYPE, SIZE AND INSTALLATION
 MANUAL SHALL BE SUBMITTED FOR PLAN REVIEW DUE TO THE
 FACT THAT TANKLESS WATER HEATER'S OPERATE BASE ON HEAT
 RISE OF THE INCLOMING WATER SO WE NEED TO VERIFY THE
 UNIT IS PROPERLY SIZED FOR THE HOME.
  
 7) ANSWERED.
  
 8) 2ND REQUEST. IN THE PLUMBING NOTES #14 YOU CALL YOU
 FOR A HOT WATER RETURN SYSTEM. PLEASE ADD NOTE ALL HOT
 WATER PIPING INSULATED TO A MIN R-3. FBC-ENERGY
 403.5.3.. UNABLE TO LOCATE YOUR REVISED NOTED.
  
  
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-05-15 Cont ID  
Sent By thunt Date 2019-05-15 Time 13:08 Rev Time 0.00
Received By thunt Date 2019-05-15 Time 12:02 Sent To  
Notes
2019-05-15 13:08:58PLUMBING 1ST REVISION REVIEW**DENIED**
  
 1) A GAS TANKLESS WATER HEATER IS CALLED OUT ON THE
 R405-2017 FORM LISTED @ .80 E.F. THE FEDERAL MIN
 EFFICIENCY AS OF 12/29/2016 IS .82%. REFER TO FEDERAL
 REGISTER VOL. 81, NO. 250.
  
 2) PROVIDE LOCATION OF THE ACCESSIBLE SHUT OFF VALVES
 FOR THE STACKABLE WASHING AND DRYER. FBC-R P2903.9.3
  
 3)PROVIDE NOTE THAT FREE STANDING TUB VALVE SHALL BE
 TEMPERED BY AN ASSE 1070 DEVICE PER FBC-R P 2713.3 OR
 MEET ONE OF THE REQUIREMENTS IN P2708.4
  
 4) ISOMETRIC DRAWING ON SHT. E1.0 MASTER BATHROOM SHOW
 2 FIXTURES BEYOND THE ACTUAL VENT. ONLY ONE IS
 PERMITTED IN A WET VENT SYSTEM. FBC-R P3108.2.1 AND THE
 FOYER BATH SHALL HAVE EACH WET-VENTED FIXTURE CONNECT
 TO THE HORIZONTALLY BRANCH IS PART OF THE WET VENT.
 FBC-R P3108.1
  
 5) SHT. E1.0 PANEL SCHEDULE CALLS OUT ELC TANKLESS
 4.5KW WHILE THE R405-2017 FORM CALLS OUT GAS TANKLESS.
 PLEASE CLARIFY AND PROVIDE LOCATION PLAN OF TANKLESS
 WATER HEATER. FBC 107.3.5
  
 6) PROVIDE COMPLETE INSTALLATION MANUAL FOR TANKLESS
 WATER HEATER TO INCLUDE HEAT RISE CHARTS. FBC 107.2.1
  
 7) PROVIDE SHOWER PAN DETAIL TO SHOW PRE-PITCH AS
 REQUIRED IN FBC-R P 2709.3
  
 8) IN THE PLUMBING NOTES #14 YOU CALL YOU FOR A HOT
 WATER RETURN SYSTEM. PLEASE ADD NOTE ALL HOT WATER
 PIPING OUTSIDE THE CONDITIONED SPACE SHALL BE INSULATED
 TO A MIN R-3. FBC-ENERGY 403.5.3.
  
  
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
 [email protected]

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2019-05-22 Cont ID  
Sent By cthroop Date 2019-05-22 Time 14:25 Rev Time 0.00
Received By cthroop Date 2019-05-22 Time 08:10 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2019-06-27 Cont ID  
Sent By aborngra Date 2019-06-27 Time 08:18 Rev Time 0.00
Received By aborngra Date 2019-06-27 Time 08:17 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2019-05-15 Cont ID  
Sent By aborngra Date 2019-05-15 Time 09:41 Rev Time 0.00
Received By aborngra Date 2019-05-15 Time 09:41 Sent To PC
Notes
***NONE***