Plan Review Stops For Permit 19050357 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-06-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-06-26 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-06-26 |
Time |
15:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-05-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-05-22 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-05-22 |
Time |
08:10 |
Sent To |
|
|
Notes |
2019-05-22 16:01:59 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | EDITION | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | 1. UPDATE APPLICABLE CODE ON PLAN PAGE C1 TO 6TH | | EDITION 2017 FBC. | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | 2. PROVIDE 2 COPIES OF A CURRENT SURVEY. | | 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS SUBMITTED | | WITH THE APPLICATION FOR PERMIT SHALL BE ACCOMPANIED BY | | A SITE PLAN SHOWING TO SCALE THE SIZE AND LOCATION OF | | NEW CONSTRUCTION AND EXISTING STRUCTURES ON THE SITE, | | DISTANCES FROM LOT LINES, THE ESTABLISHED STREET GRADES | | AND THE PROPOSED FINISHED GRADES, DEPICTING THE | | PROPOSED LOT DRAINAGE AND, AS APPLICABLE, FLOOD HAZARD | | AREAS, FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT | | SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | INCLUDED ON A BOUNDARY LINE SURVEY. | | | | 3. PROVIDE A SITE DRAINAGE PLAN. | | FBC R401.3 SITE DRAINAGE | | PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING | | COMPLIANCE WITH FBC R401.3. | | | | 4. PROVIDE AN ACCURATELY COMPLETED ENERGY SUBMITTAL. | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | | | 5. PROVIDE DESIGN PRESSURES FOR ALL EXTERIOR DOOR | | OPENINGS. | | FBC 107.3.5.3 ? PROVIDE WIND DESIGN LOADS/DESIGN | | PRESSURES PURSUANT TO FBC-R301.2. | | | | 6. PLANS INDICATE THE DEMOLITION OF A SWIMMING POOL. | | SWIMMING POOL REMOVAL REQUIREMENTS HAVE BEEN INCLUDED | | IN YOUR SUBMITTAL. | | APPLICATION PROPOSES DEMOLITION OF A SWIMMING POOL. | | PLEASE PROVIDE A UTILITY RELEASE, CITY OF WEST PALM | | BEACH WATER DEPARTMENT, ON THEIR FORM "DEMOLITION | | APPLICATION" (CROSS OFF THE PORTIONS WHICH REFER TO | | METER PULL, NOTE THIS IS DEMOLITION OF SWIMMING POOL | | ONLY): | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | IF A HYDRANT METER OR BACKFLOW PREVENTER IS DESIRED, | | THEN A PARTIAL RELEASE WILL BE NOTED ON THEIR FORM. | | FAX THE COMPLETED "DEMOLITION APPLICATION" FORM TO | | 561-822-2183. AFTER THEY FAX THE RELEASE TO YOU, SEND A | | COPY VIA EMAIL TO [email protected] WITH THE PERMIT | | NUMBER IN THE SUBJECT LINE. | | NOTE THAT THIS PROPERTY DOES NOT HAVE A BACKFLOW | | PREVENTER IN OUR RECORDS AND IT IS NOT CLEAR HOW DUST | | CONTROL WILL BE ACCOMPLISHED. | | | | 7. PLANS SPECIFY R-30 SPRAY FOAM INSULATION IN CEILING | | ASSEMBLY. PROVIDE MANUFACTURERS SPECIFICATIONS. | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2019-07-08 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-07-08 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-07-08 |
Time |
15:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2019-06-18 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-06-18 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-06-18 |
Time |
15:54 |
Sent To |
|
|
Notes |
2019-06-18 15:27:35 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. THERE IS A CONFLICT BETWEEN THE RISER DIAGRAM AND | | THE PANEL SCHEDULES. IS PANEL B FED FROM PANEL A, OR IS | | IT FED FROM PANEL B DISCONNECT? WHERE IS PANEL B | | DISCONNECT FED FROM? THERE IS CONFLICT ALSO WITH WIRE | | SIZE WITH PANEL A STATING THAT PANEL B IS FED WITH 6 | | GAUGE WIRE AND THE RISER STATING THAT IT IS FED WITH 1 | | GAUGE WIRE. PROVIDE CLARIFICATIONS AND/OR CORRECTIONS | | AS NEEDED. NEC 215.5; WPB FBC 107.2.1 | | 2. PROVIDE LOAD CALCULATION FOR PANEL B. IF THIS PANEL | | IS FED WITH LESS THAN A 100 AMP FEEDER, DEMAND FACTORS | | ARE NOT PERMITTED TO BE USED. NEC 220; FBC RE E3602.2 | | OR E3701.2 AS APPLICABLE. | | 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC | | RE E3606.3 | | 4. PROVIDE GFCI PROTECTION FOR GAS WATER HEATER IGNITOR | | RECEPTACLE. NEC 210.8; FBC RE E3902.3 | | 5. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | 210.8(D); FBC RE E3902.10 | | 6. GFCI PROTECTION IS REQUIRED FOR ALL RECEPTACLE | | OUTLETS IN GARAGE, INCLUDING THE GARAGE DOOR OPENER. | | PROVIDE CORRECTION. NEC 210.8; FBC RE E3902.2 | | 7. AFCI PROTECTION SHOWN IS NOT CODE COMPLIANT. ALL | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | 210.8, 210.12; FBC RE E3902; FBC EX 607.1.1 OR 801.1, | | 801.2, OR 901.2 AS APPLICABLE. | | 8. THERE ARE TWO SHEETS NAMED E1.0. THE SECOND ONE HAS | | THE PLUMBING RISER ON IT. PROVIDE CORRECTION. WPB FBC | | 107.2.1 | | 9. THE CONDUIT FROM METER CAN TO MAIN SERVICE | | DISCONNECT SHOULD NOT INCLUDE AN EQUIPMENT GROUNDING | | CONDUCTOR. PROVIDE CORRECTION. | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-05-20 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-05-20 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-05-20 |
Time |
11:25 |
Sent To |
|
|
Notes |
2019-05-20 11:43:57 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | FLORIDA BUILDING CODE 2017 6TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED | | NFPA 70 2014 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | PG. E1.0 | | | | SEVERAL BEDROOMS HAVE NO SMOKE ALARMS/ CO ALARMS | | | | FOYER MAY NEED OUTLETS PER FBC E3901.11 | | | | PENINSULAR OUTLETS IN THE KITCHEN PER FBC E3901.4.3 | | | | RISER DIAGRAM SHOWS 300 AMPERE SERVICE BUT WIRE SIZE IS | | ONLY GOOD FOR 150 AMPERES | | | | PANEL SIZE SHOWS 200 AMPERES BEING FED BY A 300 AMPERE | | SWITCH. | | | | PANEL BOARD IDENTIFICATION | | E3706.2PANELBOARD CIRCUIT IDENTIFICATION. | | ALL CIRCUITS AND CIRCUIT MODIFICATIONS SHALL BE LEGIBLY | | IDENTIFIED AS TO THEIR CLEAR, EVIDENT, AND SPECIFIC | | PURPOSE OR USE. | | THE IDENTIFICATION SHALL INCLUDE AN APPROVED DEGREE OF | | DETAIL THAT ALLOWS EACH CIRCUIT TO BE DISTINGUISHED | | FROM ALL OTHERS. | | SPARE POSITIONS THAT CONTAIN UNUSED OVERCURRENT DEVICES | | OR SWITCHES SHALL BE DESCRIBED ACCORDINGLY. THE | | IDENTIFICATION | | SHALL BE INCLUDED IN A CIRCUIT DIRECTORY LOCATED ON THE | | FACE OF THE PANELBOARD ENCLOSURE OR INSIDE THE PANEL | | DOOR. CIRCUITS | | SHALL NOT BE DESCRIBED IN A MANNER THAT DEPENDS ON | | TRANSIENT CONDITIONS OF OCCUPANCY. [408.4(A)] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
N |
Date |
2019-07-02 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-07-02 |
Time |
08:30 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-07-02 |
Time |
08:30 |
Sent To |
|
|
Notes |
2019-07-02 08:30:14 | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | THIS TIME. A SEPARATE GAS PERMIT IS REQUIRED FOR A | | CONTRACTOR TO PERFORM THE RELATED WORK. PROVIDE | | COMPLETE PLANS THAT REFLECT THE ENTIRE SCOPE OF GAS | | WORK TO BE DONE. WPB AMEND. TO FBC SEC.107.2.1. | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2019-06-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-06-26 |
Time |
16:02 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-06-26 |
Time |
15:20 |
Sent To |
|
|
Notes |
2019-06-26 16:03:42 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | A SEPERATE GAS PERMIT IS REQUIRED FOR THIS SCOPE OF | | WORK. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2019-05-15 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-05-15 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-05-15 |
Time |
13:09 |
Sent To |
|
|
Notes |
2019-05-15 13:10:45 | GAS 1ST REVIEW**DENIED** | | | | A GAS TANKLESS WATER HEATER IS CALLED OUT ON THE | | R405-2017 ENERGY FORM BUT NO GAS PLAN HAS NOT BEEN | | INCLUDED IN THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW | | HAS NOT BEEN PERFORMED AT THIS TIME. A SEPARATE GAS | | PERMIT IS REQUIRED FOR A CONTRACTOR TO PERFORM THE | | RELATED WORK. PROVIDE COMPLETE PLANS THAT REFLECT THE | | ENTIRE SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC | | SEC.107.2.1. | | | | | | | | | | TIM HUNT | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | BUILDING DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | 561-248-2703 | | [email protected] | | [email protected] | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2019-06-27 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2019-06-27 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2019-06-20 |
Time |
15:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2019-05-15 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2019-05-15 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2019-05-15 |
Time |
09:41 |
Sent To |
PC |
|
Notes |
2019-05-15 11:05:28 | THE PERMIT HAS BEEN APPROVED WITH THE FOLLOWING | | CONDITION(S): | | | | 1. ALL WINDOWS AND DOORS SHALL HAVE CLEAR GLASS OR | | LOW-E GLASS. | | 2. ALL WINDOWS SHALL HAVE EXTERNAL DIMENSIONAL PYRAMID | | MUNTINS. | | 3. ALL REPLACEMENT WINDOWS SHALL BE SIZED TO FIT THE | | WINDOW FRAME OPENING AND THE LOCATION WITHIN THE WINDOW | | OPENING. | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | HISTORIC PRESERVATION PLANNER AT [email protected] | | AARON BORNGRABER | | HISTORIC PRESERVATION PLANNER | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | T: 561-822-1428 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-07-08 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-07-08 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-06-28 |
Time |
14:00 |
Sent To |
|
|
Notes |
2019-07-01 14:00:16 | RESUB ROUTED TO THUNT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-06-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-06-26 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-06-13 |
Time |
15:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-05-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-05-22 |
Time |
16:20 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-05-07 |
Time |
13:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2019-07-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-07-11 |
Time |
12:39 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-07-11 |
Time |
12:37 |
Sent To |
|
|
Notes |
2019-07-11 12:39:34 | MU-2019-021253-0000. CT |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2019-05-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-05-22 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-05-22 |
Time |
08:10 |
Sent To |
|
|
Notes |
2019-05-22 14:26:48 | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL, YOU MAY CHECK OUT ONE | | PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. PLEASE | | RETURN STAMPED AND WITH A COPY OF THE RECEIPT AS | | APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2019-06-26 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-06-26 |
Time |
16:16 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-06-26 |
Time |
15:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2019-05-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-05-22 |
Time |
16:02 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-05-22 |
Time |
08:10 |
Sent To |
|
|
Notes |
2019-05-22 16:13:15 | MECHANICAL PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | CODES IN EFFECT: | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC M = FLORIDA BUILDING CODE MECHANICAL 2017 6TH | | EDITION | | FBC P = FLORIDA BUILDING CODE PLUMBING 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | 1. PROVIDE AN ACCURATELY COMPLETED ENERGY SUBMITTAL. | | CEILING INSULATION VALUE ON ENERGY SUBMITTAL DOES NOT | | MATCH APPROVED DESIGN. | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | COMPLIANCE BY SECTION 405. | | | | 2. PLAN SHOWS 3 SYSTEMS, ENERGY SUBMITTAL SHOWS 1 | | SYSTEM. PLEASE CLARIFY. | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | 3. ENERGY SUBMITTAL SPECIFIES GAS FUELED TANKLESS WATER | | HEATER. PLANS SPECIFY ELECTRIC WATER HEATER. PLEASE | | CLARIFY. | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | 4. PROVIDE PRODUCT APPROVAL FOR CU TIE-DOWN. | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE CU TIE-DOWN SUBMITTALS. | | | | 5. MECHANICAL PLAN M.1 DOES NOT SHOW LOCATION OF CU #2 | | AND CU #3. PLEASE CLARIFY. | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED. | | | | | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2019-07-02 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-07-02 |
Time |
08:30 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-07-02 |
Time |
06:34 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2019-06-17 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-06-17 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-06-17 |
Time |
13:49 |
Sent To |
|
|
Notes |
2019-06-17 14:32:08 | PLUMBING 2ND REVIEW**DENIED**FL ST 553.80 (B)2BWITH | | RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | 1) 2ND REQUEST.A GAS TANKLESS WATER HEATER IS CALLED | | OUT ON THE R405-2017 FORM LISTED @ .80 E.F. THE FEDERAL | | MIN EFFICIENCY AS OF 12/29/2016 IS .82%. REFER TO | | FEDERAL REGISTER VOL. 81, NO. 250. YOU MUST SUBMIT A | | CORRECTED R405-2017 FORM WITH THE CORRECT E.F. ALSO IT | | IS STILL UNCLEAR IF THE WATER HEATER IS GAS OR ELC | | TANKLESS. PLEASE CLARIFY. | | | | 2) ANSWERED | | | | 3) ANSWERED | | | | 4) 2ND REQUEST. ISOMETRIC DRAWING ON SHT. E1.0 MASTER | | BATHROOM SHOW 2 FIXTURES BEYOND THE ACTUAL VENT. ONLY | | ONE IS PERMITTED IN A WET VENT SYSTEM. FBC-R P3108.2.1 | | AND THE FOYER BATH SHALL HAVE EACH WET-VENTED FIXTURE | | CONNECT TO THE HORIZONTALLY BRANCH IS PART OF THE WET | | VENT. FBC-R P3108.1 | | | | 5) 2ND REQUEST* NOT FULLY ADDRESSED. SHT. E1.0 PANEL | | SCHEDULE SHOWS1 DOUBLE 50 AMP BREAKER FOR THE TANKLESS. | | THE MAX WATER HEATER BASED ON BREAKER WOULD BE A MAX | | 11KW. THIS WOULD BE UNDERSIZED FOR THIS HOME. FBC | | 107.3.5 | | | | 6) 2ND REQUEST.PROVIDE COMPLETE INSTALLATION MANUAL FOR | | TANKLESS WATER HEATER TO INCLUDE HEAT RISE CHARTS. FBC | | 107.2.1. THE WATER HEATER TYPE, SIZE AND INSTALLATION | | MANUAL SHALL BE SUBMITTED FOR PLAN REVIEW DUE TO THE | | FACT THAT TANKLESS WATER HEATER'S OPERATE BASE ON HEAT | | RISE OF THE INCLOMING WATER SO WE NEED TO VERIFY THE | | UNIT IS PROPERLY SIZED FOR THE HOME. | | | | 7) ANSWERED. | | | | 8) 2ND REQUEST. IN THE PLUMBING NOTES #14 YOU CALL YOU | | FOR A HOT WATER RETURN SYSTEM. PLEASE ADD NOTE ALL HOT | | WATER PIPING INSULATED TO A MIN R-3. FBC-ENERGY | | 403.5.3.. UNABLE TO LOCATE YOUR REVISED NOTED. | | | | | | | | | | TIM HUNT | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | BUILDING DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | 561-248-2703 | | [email protected] | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-05-15 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-05-15 |
Time |
13:08 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-05-15 |
Time |
12:02 |
Sent To |
|
|
Notes |
2019-05-15 13:08:58 | PLUMBING 1ST REVISION REVIEW**DENIED** | | | | 1) A GAS TANKLESS WATER HEATER IS CALLED OUT ON THE | | R405-2017 FORM LISTED @ .80 E.F. THE FEDERAL MIN | | EFFICIENCY AS OF 12/29/2016 IS .82%. REFER TO FEDERAL | | REGISTER VOL. 81, NO. 250. | | | | 2) PROVIDE LOCATION OF THE ACCESSIBLE SHUT OFF VALVES | | FOR THE STACKABLE WASHING AND DRYER. FBC-R P2903.9.3 | | | | 3)PROVIDE NOTE THAT FREE STANDING TUB VALVE SHALL BE | | TEMPERED BY AN ASSE 1070 DEVICE PER FBC-R P 2713.3 OR | | MEET ONE OF THE REQUIREMENTS IN P2708.4 | | | | 4) ISOMETRIC DRAWING ON SHT. E1.0 MASTER BATHROOM SHOW | | 2 FIXTURES BEYOND THE ACTUAL VENT. ONLY ONE IS | | PERMITTED IN A WET VENT SYSTEM. FBC-R P3108.2.1 AND THE | | FOYER BATH SHALL HAVE EACH WET-VENTED FIXTURE CONNECT | | TO THE HORIZONTALLY BRANCH IS PART OF THE WET VENT. | | FBC-R P3108.1 | | | | 5) SHT. E1.0 PANEL SCHEDULE CALLS OUT ELC TANKLESS | | 4.5KW WHILE THE R405-2017 FORM CALLS OUT GAS TANKLESS. | | PLEASE CLARIFY AND PROVIDE LOCATION PLAN OF TANKLESS | | WATER HEATER. FBC 107.3.5 | | | | 6) PROVIDE COMPLETE INSTALLATION MANUAL FOR TANKLESS | | WATER HEATER TO INCLUDE HEAT RISE CHARTS. FBC 107.2.1 | | | | 7) PROVIDE SHOWER PAN DETAIL TO SHOW PRE-PITCH AS | | REQUIRED IN FBC-R P 2709.3 | | | | 8) IN THE PLUMBING NOTES #14 YOU CALL YOU FOR A HOT | | WATER RETURN SYSTEM. PLEASE ADD NOTE ALL HOT WATER | | PIPING OUTSIDE THE CONDITIONED SPACE SHALL BE INSULATED | | TO A MIN R-3. FBC-ENERGY 403.5.3. | | | | | | | | | | TIM HUNT | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | BUILDING DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | 561-248-2703 | | [email protected] | | [email protected] |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2019-05-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-05-22 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-05-22 |
Time |
08:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2019-06-27 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2019-06-27 |
Time |
08:18 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2019-06-27 |
Time |
08:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2019-05-15 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2019-05-15 |
Time |
09:41 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2019-05-15 |
Time |
09:41 |
Sent To |
PC |
|
Notes |
|
|