Plan Review Details - Permit 19050158
Plan Review Stops For Permit 19050158 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2019-10-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-10-04 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-10-04 |
Time |
13:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2019-09-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-11 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-10 |
Time |
17:05 |
Sent To |
|
|
Notes |
2019-09-11 10:04:03 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | THE FOLLOWING TWO ITEMS FROM THE 1ST REVIEW HAVE NOT | | BEEN ADDRESSED. | | | | 3. A STOP WORK ORDER WAS ISSUED FOR THIS PROPERTY, ROOF | | FRAMING WITHOUT A PERMIT. | | | | 4. THERE ARE FINANCE HOLDS ON THIS PROPERTY, PLEASE | | RESOLVE. PLEASE SEND AN EMAIL TO ME REQUESTING FINANCE | | CONTACT INFORMATION. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | REVIEWED SHEETS DETACHED. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-05-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-05-17 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-05-17 |
Time |
16:09 |
Sent To |
|
|
Notes |
2019-05-17 16:14:50 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC 107, THERE WAS ANOTHER PERMIT APPLICATION FOR | | "CONVERT GARAGE INTO GAME ROOM", SAME ADDRESS, NO | | PLANS. REMOVE DOCUMENTS NOT APPLICABLE TO THIS JOB, | | | | 2. FS553, COVER PAGE REFERS TO AN OUTDATED BUILDING | | CODE, REVISE. | | | | 3. A STOP WORK ORDER WAS ISSUED FOR THIS PROPERTY, ROOF | | FRAMING WITHOUT A PERMIT. | | | | 4. THERE ARE FINANCE HOLDS ON THIS PROPERTY, PLEASE | | RESOLVE. PLEASE SEND AN EMAIL TO ME REQUESTING FINANCE | | CONTACT INFORMATION. | | | | 5. FS471, FAC61G15-23.002, THE TITLE BLOCK FOR THE | | ENGINEER SHOULD INCLUDE THE CERTIFICATE OF | | AUTHORIZATION FOR "RENEWABLE DESIGN", REVISE TO | | INCLUDE. | | | | 6. FBC 107, PRODUCT APPROVALS ARE TO BE REVIEWED BY | | DESIGNER OF RECORD. | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2019-08-16 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-08-16 |
Time |
12:41 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-08-16 |
Time |
10:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-05-21 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-05-21 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-05-21 |
Time |
13:19 |
Sent To |
|
|
Notes |
2019-05-21 14:19:41 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | LOADS FOR THE SERVICE, AS WELL AS THE LOAD CALCULATINS | | FOR THE INDIVIDUAL PANELS. NEC 220; FBC RE E3602.2 | | 2. RISER DIAGRAM SHOWS AN INSTALLATION THAT IS NOT CODE | | COMPLIANT. MAINS NEEDS TO BE GROUPED. PROVIDE | | CORRECTION. NEC 230.72; FBC RE E3601.6 | | 3. LOCATION OF ELECTRICAL PANELS WOULD INDICATE THAT | | THERE ARE CONDUCTORS WITH NO OVER CURRENT PROTECTION | | INSTALLED IN THE DWELLING, WHICH IS A CODE VIOLATION. | | PROVIDE CORRECTION. NEC 230.70; FBC RE E3601.6 | | 4. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10; FBC | | RE E3606.3 | | 5. PROVIDE AIC RATING OF SERVICE DISCONNECTS/PANELS. | | NEC 110.3, 110.9; FBC RE E3606.3 | | 6. AFCI PROTECTION SHOWN IS NOT CODE COMPLIANT. ALL | | BRANCH CIRCUITS THAT SUPPLY 120-VOLT, SINGLE-PHASE, 15- | | AND 20-AMPERE OUTLETS INSTALLED IN KITCHENS, FAMILY | | ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, | | DENS, BEDROOMS, SUN-ROOMS, RECREATIONS ROOMS, CLOSETS, | | HALLWAYS, LAUNDRY AREAS AND SIMILAR ROOMS OR AREAS | | SHALL BE AFCI PROTECTED. THIS INCLUDES LIGHTING AND | | POWER OUTLETS AND RECEPTACLES. SOME AREAS REQUIRE BOTH | | AFCI AND GFCI PROTECTION. PROVIDE CORRECTION. NEC | | 210.8, 210.12; FBC RE E3902; FBC EX 607.1.1 OR 801.1, | | 801.2, OR 901.2 AS APPLICABLE. | | 7. SMOKE ALARMS MUST BE INSTALLED AT LEAST 3 FEET FROM | | BATHROOM DOOR, 3 FEET FROM CEILING FANS, AND 3 FEET | | FROM ANY MECHANICAL DUCT. PROVIDE CORRECTIONS. FBC RE | | R314.3(4), NFPA 72:29.8.3.4 | | 8. PROVIDE GFCI PROTECTION FOR DISHWASHER. NEC | | 210.8(D); FBC RE E3902.10 | | 9. THE # 6 EQUIPMENT GROUNDING CONDUCTOR SHOULD NOT BE | | INCLUDED IN THE CONDUIT FROM THE METER TO THE FIRST | | MEANS OF DISCONNECT. PROVIDE CORRECTION. NEC 250.6; FBC | | RE E3610.4 | | 10. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | SERVICE. SHOW ON PLAN. NEC 250.94; FBC RE E3609.3 | | 11. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR | | A BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | CIRCUIT. NEC 250.32; FBC RE3607.3 | | 12. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | STRUCTURE SUPPLIED IN ADDITION TO THE MAIN GROUPED PER | | COMMENT #2 ABOVE. PROVIDE EITHER A MAIN DISCONNECT OR | | MAIN BREAKER AT THE PANEL FOR THE DETACHED GARAGE. NEC | | 225.31, 225.32 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-10-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-10-04 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-10-04 |
Time |
13:50 |
Sent To |
|
|
Notes |
2019-10-04 13:50:36 | ROUTED TO CTHROOP DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-09-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-11 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-08-09 |
Time |
14:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-05-25 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2019-05-25 |
Time |
06:45 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2019-05-25 |
Time |
06:45 |
Sent To |
|
|
Notes |
2019-05-24 07:08:37 | 5/24 TO CM DESK | | | | | 2019-05-07 10:09:29 | R04 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2019-05-25 |
|
|
Cont ID |
|
Sent By |
cmontell |
Date |
2019-05-25 |
Time |
06:44 |
Rev Time |
0.00 |
Received By |
cmontell |
Date |
2019-05-25 |
Time |
06:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2019-08-21 |
|
|
Cont ID |
|
Sent By |
lcrespo |
Date |
2019-08-21 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
lcrespo |
Date |
2019-08-21 |
Time |
16:25 |
Sent To |
|
|
Notes |
2019-08-21 16:26:57 | 08/21/19 REVIEWED FOR CODE COMPLIANCE (PLUMBING) | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | LUIS A. CRESPO | | PLUMBING PLAN EXAMINER | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-05-13 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-05-13 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-05-09 |
Time |
16:23 |
Sent To |
|
|
Notes |
2019-05-13 10:41:32 | 1ST REVIEW: 19050158 | | | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | PLUMBING COMMENTS: | | | | 1. SHT 1 OF 1 PLEASE SHOW EXISTING PLUMBING FIXTURES ON | | DEMO PLAN. PER WPB AMEND TO FBC 107.2.1 | | | | 2. THE VALUATION OF THE PROJECT SEEMS LOW PLEASE | | PROVIDE A DETAILED, QUANTITY ESTIMATES, AND/OR BONA | | FIDE SIGNED CONTRACTS (EXCLUDING LAND VALUE) TO MEET | | THE | | APPROVAL OF THE BUILDING OFFICIAL.PER WPB AMEND TO FBC | | 109.3 | | | | 3. ON THE SANITARY ISOMETRIC DRAWING THE WASHING | | MACHINE AND LAUNDRY SINK SHALL CONNECT TO THE BUILDING | | DRAIN DOWN STREAM OF THE BATHROOM GROUP ONLY THE | | FIXTURES IN THE BATHROOM GROUP CAN CINNECT TO THE WET | | VENT SYSTEM FOR THE BATHROOM GROUP. PER FBC RES P3108 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
P |
Date |
2019-10-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-10-04 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-10-04 |
Time |
13:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2019-09-11 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-09-11 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-09-10 |
Time |
17:05 |
Sent To |
|
|
Notes |
2019-09-11 10:15:39 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | CHRISTOPHER S. THROOP, C.B.O. | | BUILDING PLANS EXAMINER, PX3169 | | 1&2 FAMILY PLANS EXAMINER, SFP306 | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6726 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | | | RESULTS: DENIED | | | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. PROVIDE PRODUCT APPROVALS FOR ROOFING SYSTEM | | COMPONENTS. | | | | FBC 107.3.4 ? PROVIDE PRODUCT APPROVALS FOR THOSE | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2019-08-12 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2019-08-12 |
Time |
07:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2019-08-12 |
Time |
07:21 |
Sent To |
|
|
Notes |
2019-08-12 07:21:58 | SEE BUILDING REVIEW. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2019-08-16 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2019-08-16 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2019-08-16 |
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2019-05-15 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2019-05-15 |
Time |
|
Rev Time |
|
Received By |
llouie |
Date |
2019-05-15 |
Time |
|
Sent To |
|
|
Notes |
2019-05-15 11:20:14 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) UPDATED, SIGNED AND SEALED SURVEY IS MISSING FROM | | THE PERMIT APPLICATION. PLEASE PROVIDE. | | | | 2.) SITE PLAN IS MISSING FROM THE SUBMITTAL. PLEASE | | PROVIDE. | | | | 3.) PERMIT PLANS INDICATE NEW ELECTRICAL WORK TO BE | | DONE. LOCATION OF THE CONCRETE PAD(S) FOR THE A/C | | COMPRESSOR(S) MUST BE PROVIDED IN THE SITE PLAN OF THE | | PROPERTY WITH SETBACK DIMENSIONS. PLEASE NOTE THAT THE | | PAD CANNOT ENCROACH MORE THAN 4 FT. INTO A REQUIRED | | SETBACK. [ZLDR S.94-305(B)(4)] | | | | 4.) HEIGHT OF THE BUILDING(S) SHALL BE MEASURED FROM | | GRADE TO THE HIGHEST POINT OR MID HEIGHT LEVEL BETWEEN | | THE EAVES AND RIDGE FOR A GABLED ROOF. PLEASE REVISED | | MEASUREMENTS IN THE ELEVATIONAL DRAWINGS. | | | | 5.) THE VALUE OF THE CONSTRUCTION ($60,000.00) EXCEEDS | | 50% OF THE STRUCTURE'S VALUE ($74,744.00) ACCORDING TO | | THE P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, | | PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | TO BRING THE SITE INTO CONFORMITY. | | | | | | NOTES: | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * NO KITCHEN FACILITY PERMITTED IN THE ACCESSORY | | STRUCTURE (GARAGE CONVERSION) | | | | * ZONE: SF14 | | |
|
|
|