Plan Review Details - Permit 19050110
Plan Review Stops For Permit 19050110
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-05-13 Cont ID  
Sent By jduprey Date 2019-05-13 Time 13:50 Rev Time 0.00
Received By jduprey Date 2019-05-13 Time 13:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-05-03 Cont ID  
Sent By jduprey Date 2019-05-03 Time 13:46 Rev Time 0.00
Received By jduprey Date 2019-05-03 Time 13:46 Sent To  
Notes
2019-05-03 13:57:39BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 JOSEAN A. DUPREY E.I., BN, PX
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6716
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PER FBC R301.2(2) THE ROOF PRESSURE ARE AS FOLLOW:
 ZONE 1: -31PSF
 ZONE 2: -52PSF
 ZONE 3: -78PSF
  
 THE THE PRODUCT SELECTED ON THE NOA 16-0413.06 HAVE A
 MAXIMUN PRESSURE ON THE FIELD OF -52.5PSF. PER NOA
 REQUIREMENT ON LIMITATION #7 PROVIDE ENHANCED FASTENER
 PATERN AS CALCULATED IN COMPLIANCE WITH RAS117/.
 CALCULATIONS MUST SIGNED AND SEAL BY A PROFESSIONAL
 ENGINEER, REGISTERED ARCHITECT OR REGISTERED ROOF
 CONSULTANT.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-05-13 Cont ID  
Sent By jduprey Date 2019-05-13 Time 13:50 Rev Time 0.00
Received By jduprey Date 2019-05-10 Time 12:56 Sent To  
Notes
2019-05-13 12:57:08RESUB ROUTED TO JDUPREY

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-05-03 Cont ID  
Sent By jduprey Date 2019-05-03 Time 13:57 Rev Time 0.00
Received By jduprey Date 2019-05-02 Time 15:38 Sent To  
Notes
2019-05-02 15:38:43REROOF BIN