Plan Review Stops For Permit 19041353 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2019-05-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2019-05-02 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2019-05-02 |
Time |
11:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2019-05-02 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-05-02 |
Time |
16:31 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-05-02 |
Time |
16:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2019-07-01 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-07-01 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-07-01 |
Time |
09:55 |
Sent To |
|
|
Notes |
2019-07-01 09:55:38 | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | THIS TIME. A SEPARATE GAS PERMIT IS REQUIRED FOR A | | CONTRACTOR TO PERFORM THE RELATED WORK. PROVIDE | | COMPLETE PLANS THAT REFLECT THE ENTIRE SCOPE OF GAS | | WORK TO BE DONE. WPB AMEND. TO FBC SEC.107.2.1. | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2019-05-01 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-05-01 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-05-01 |
Time |
15:24 |
Sent To |
|
|
Notes |
2019-05-01 15:24:56 | GAS 1ST REVIEW**DENIED** | | | | | | 1) A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | THIS TIME. A SEPARATE GAS PERMIT IS REQUIRED FOR A | | CONTRACTOR TO PERFORM THE RELATED WORK. PROVIDE | | COMPLETE PLANS THAT REFLECT THE ENTIRE SCOPE OF GAS | | WORK TO BE DONE. WPB AMEND. TO FBC SEC.107.2.1 | | | | 2) 2017 FBC- ENERGY- SEC. R 403.10.3. - HEATED SWIMMING | | POOLS AND IN GROUND PERMANENTLY INSTALLED SPAS SHALL BE | | EQUIPPED WITH A VAPOR-RETARDANT COVER ON OR AT THE | | WATER SURFACE OR A LIQUID COVER OR OTHER MEANS PROVEN | | TO REDUCE HEAT LOSS. | | | | | | TIM HUNT | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | BUILDING DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | 561-248-2703 | | [email protected] | | [email protected] | | | | | | . | | | | | | | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
N |
Date |
2019-05-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2019-05-02 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2019-05-02 |
Time |
11:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-07-01 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-07-01 |
Time |
10:03 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-06-26 |
Time |
15:24 |
Sent To |
|
|
Notes |
2019-06-27 15:24:57 | RESUB ROUTED TO THUNT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
P |
Date |
2019-05-02 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-05-02 |
Time |
16:32 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-04-26 |
Time |
12:49 |
Sent To |
|
|
Notes |
2019-04-29 12:49:18 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2019-07-01 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-07-01 |
Time |
10:03 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-07-01 |
Time |
10:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-05-01 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-05-01 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-05-01 |
Time |
15:30 |
Sent To |
|
|
Notes |
2019-05-01 15:26:36 | PLUMBING 1ST REVIEW**DENIED** | | | | 1) SUBMIT TOTAL DYNAMIC HEAD CALCULATIONS FOR THE | | MAXIMUM SYSTEM FLOW. THE MAXIMUM FLOW OF THE PUMP FROM | | ITS PUMP CURVE AND THE SIMPLIFIED TOTAL DYNAMIC HEAD | | CALCULATION IS NO LONGER ALLOWED TO BE USED IN | | DETERMINING MAXIMUM SYSTEM FLOW RATE PER ANSI/APSP/ICC | | 7 - 2013 SECS. 4.4.9, 4.4.9.1. THE 2013 EDITION | | ADDRESSES FLOW RATE IN GALLONS PER MINUTE (GPM). IT | | REQUIRES THAT MAXIMUM SYSTEM FLOW RATE DOES NOT EXCEED | | THE LISTED MAXIMUM FLOW RATE OF THE SUCTION OUTLET | | FITTING ASSEMBLY (DRAIN COVER).THE TDH CALCULATIONS | | MUST INCLUDE ALL OF THE SYSTEM COMPONENTS INCLUDING | | SUCTION AND RETURN PIPING, FITTINGS, VALVES, HEATER, | | FILTER, AND CHLORINATOR. ALL SYSTEM COMPONENTS EXCEPT | | THE PUMP. | | | | 2) IDENTIFY ON THE PUMP CURVE WHICH CURVE KEY IS | | SPECIFIC TO THE PUMP BEING INSTALLED ON THIS POOL. THIS | | IS NEEDED TO CONFIRM THE MAXIMUM SYSTEM FLOW FROM THE | | TDH CALCULATIONS. ANSI/APSP/ICC 7 - 2013 SECS. 4.4.9, | | 4.4.9.1 | | | | TIM HUNT | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | BUILDING DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | 561-248-2703 | | [email protected] | | [email protected] | | | | | | | | | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2019-05-01 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2019-05-01 |
Time |
12:12 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2019-05-01 |
Time |
12:11 |
Sent To |
|
|
Notes |
|
|