Plan Review Details - Permit 19041320
Plan Review Stops For Permit 19041320 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-06-13 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2019-06-13 |
Time |
13:10 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-06-13 |
Time |
11:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-05-15 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2019-05-15 |
Time |
07:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2019-05-14 |
Time |
18:15 |
Sent To |
I |
|
Notes |
2019-05-14 19:11:06 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) DOOR 110 FOR THE NEW IT/ELECTRICAL ROOM IS NOT | | LISTED IN THE DOOR SCHEDULE ON SHEET A2.1.1. | | | | 2) THE REVISION IS TO ADD AN IT/ELECTRICAL ROOM TO THE | | BUSINESS OCCUPANCY. FBC TABLE 509 FOR INCIDENTIAL USES | | REQUIRES A ONE HOUR FIRE SEPARATION IF THERE IS | | STATIONARY STORAGE BATTERY SYSTEMS HAVING A LIQUID | | ELECTROLYTE CAPACITY OF MORE THAN 50 GALLONS FOR | | FLOODED LEAD-ACID, NICKEL CADIUM OR VRLA, OR MORE THAN | | 1,000 POUNDS FOR LITHIUM-ION AND LITHIUM METAL POLYMER | | USED FOR FACILITY STANDBY POWER, EMERGENCY POWER OR | | UNINTERRUPTABLE POWER SUPPLIES. PLEASE ADVISE. FBC | | 509.4. | | | | 3) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | CITY RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2019-05-14 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-05-14 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-05-14 |
Time |
11:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2019-06-05 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-06-05 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-06-05 |
Time |
09:57 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2019-05-10 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2019-05-10 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-05-10 |
Time |
14:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-06-13 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-06-13 |
Time |
13:10 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-06-03 |
Time |
15:34 |
Sent To |
I |
|
Notes |
2019-06-04 15:35:04 | RESUB ROUTED TO FIRE INBOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-05-15 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2019-05-15 |
Time |
07:09 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2019-04-25 |
Time |
16:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2019-05-01 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-05-01 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-05-01 |
Time |
16:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2019-04-30 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-04-30 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-04-30 |
Time |
14:38 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |