Plan Review Details - Permit 19041286
Plan Review Stops For Permit 19041286 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-06-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-06-20 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-06-20 |
Time |
14:51 |
Sent To |
|
|
Notes |
2019-06-20 14:52:19 | ASSEMBLY REVIEWED AND OK'D BY RB | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-05-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-05-03 |
Time |
07:50 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-05-03 |
Time |
07:50 |
Sent To |
|
|
Notes |
2019-05-03 07:50:29 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. DETAIL 4-AE107, PROVIDE DETAILS FOR THE FIRE RATED | | ASSEMBLIES AS THIS IS REQUIRED FOR INSPECTIONS. I WAS | | NOT ABLE TO LOCATE GA FC 5406 OR RC 2601 FOR METAL | | FRAMING (FOUND DETAILS FOR WOOD), FBC 107. | | | | 2. REVISE PLAN TO CLARIFY WHY THE SOFFIT IS RATED, WHAT | | TYPE OF RATED WALL THIS IS (PARTITION, BARRIER, ETC) | | FBC B CHAPTER 7 AND WHY IT IS REQUIRED TO BE RATED | | (OCCUPANCY SEPARATION, ATRIUM, FIRE AREAS, OTHER | | REQUIREMENT?). | | | | 3. PLEASE NOTE THAT THE MASTER PERMIT INDEX REFERS TO | | MANY ARCHITECTURAL PAGES WHICH WERE NOT SUBMITTED. | | MASTER PERMIT 18060261 SHEET 004 WHICH IS LS100 (NOT | | NAMED PROPERLY IN PROJECTDOX) APPEARS TO DEPICT A TWO | | HOUR RATED WALL IN THIS LOCATION. DETAIL 1-004.04 AE101 | | DOES NOT SHOW CONTINUITY FOR THE RATED WALL. | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2019-06-17 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-06-17 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-06-17 |
Time |
10:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2019-05-09 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-05-09 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-05-09 |
Time |
11:55 |
Sent To |
I |
|
Notes |
2019-05-09 11:57:42 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE ARE NO INDICATIONS OF WHAT IS BEING REVISED | | FROM PREVIOUS SUBMITTAL. | | | | PER NFPA 1 | | | | 1.14 PLAN REVIEW. | | 1.14.5 WHEN REQUIRED BY THE AHJ, REVISED CONSTRUCTION | | DOCUMENTS OR SHOP DRAWINGS SHALL BE PREPARED AND | | SUBMITTED FOR REVIEW AND APPROVAL TO ILLUSTRATE | | CORRECTIONS OR MODIFICATIONS NECESSITATED BY FIELD | | CONDITIONS OR OTHER REVISIONS TO APPROVED PLANS. | | PLEASE SUBMIT PLANS THAT HAVE INDICATIONS WHERE THE | | REVISIONS OR MODIFICATIONS, FROM THE ORIGINAL PLANS, | | ARE LOCATED. | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-06-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-06-20 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-06-13 |
Time |
16:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-05-09 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2019-05-09 |
Time |
12:10 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-04-26 |
Time |
09:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2019-06-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-06-20 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-06-20 |
Time |
14:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2019-05-03 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-05-03 |
Time |
07:51 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-05-03 |
Time |
07:51 |
Sent To |
|
|
Notes |
2019-05-03 07:51:50 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. DIGITAL SIGNATURE, SEAL, TITLE BLOCK OK - NEW PAGES | | SUBMITTED NEXT REVIEW CYCLE REQUIRE VERIFICATION. | | | | |
|
|
|