Plan Review Details - Permit 19041093
Plan Review Stops For Permit 19041093
Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-05-17 Cont ID  
Sent By rcaranci Date 2019-05-17 Time 15:00 Rev Time 0.00
Received By rcaranci Date 2019-04-24 Time 13:17 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-04-22 Cont ID  
Sent By rcaranci Date 2019-04-22 Time 17:19 Rev Time 0.00
Received By rcaranci Date 2019-04-22 Time 14:55 Sent To  
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 2 Status P Date 2019-05-17 Cont ID  
Sent By rcaranci Date 2019-05-17 Time 15:00 Rev Time 0.00
Received By rcaranci Date 2019-05-14 Time 15:01 Sent To  
Notes
***NONE***

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2019-04-22 Cont ID  
Sent By rcaranci Date 2019-04-22 Time 17:19 Rev Time 0.00
Received By rcaranci Date 2019-04-22 Time 17:19 Sent To  
Notes
2019-04-22 17:19:56NEED THE FOLLOWING:
 1. PLAN SHOWING LOCATION AND LIMITS OF TURF
 INSTALLATION. HIGHLIGHT THE LIMITS OF THE AREA.
  
 2. (E) MINIMUM MATERIAL STANDARDS. ALL ARTIFICIAL TURF
 SHALL COMPLY WITH EACH OF THE FOLLOWING MINIMUM
 STANDARDS:
 (1) ARTIFICIAL TURF SHALL CONSIST OF GREEN LIFELIKE
 INDIVIDUAL BLADES OF GRASS THAT EMULATE NATURAL TURF IN
 LOOK AND COLOR.
 SPECIFICATION SHEET SHOWING MANUFACTURERS COLOR
 SELECTION
 (2) WHERE ARTIFICIAL TURF IS UTILIZED FOR INSTITUTIONAL
 RECREATIONAL USES (E.G., PLAYGROUNDS, ATHLETIC FIELDS),
 THE ARTIFICIAL TURF PRODUCT INSTALLED SHALL BE DESIGNED
 FOR THE INTENDED USE AND MEET THE APPROPRIATE
 ADDITIONAL STANDARDS.
 SHOW INTENDED USE IN DOCUMENTATION
 (3) ARTIFICIAL TURF INSTALLATIONS SHALL HAVE A MINIMUM
 PERMEABILITY OF 30 INCHES PER HOUR PER SQUARE YARD.
 SUBMIT PERMEABILITY RATE
 (4) ALL ARTIFICIAL TURF SHALL HAVE A MINIMUM EIGHT YEAR
 MANUFACTURER'S WARRANTY THAT PROTECTS AGAINST COLOR
 FADING AND A DECREASE IN PILE HEIGHT.
 SUBMIT COPY OF WARRANTY
 (5) ARTIFICIAL TURF SHALL BE LEAD FREE.
 SUBMIT LEAD TESTING RESULT DOCUMENTATION
 (6) ALL MATERIALS MUST INCLUDE TEST DOCUMENTATION WHICH
 DECLARES THAT THE ARTIFICIAL TURF YARN AND BACKING
 MATERIALS ARE DISPOSABLE UNDER NORMAL CONDITIONS, AT
 ANY U.S. LANDFILL STATION (TOTAL CONTENT LEACH PROTOCOL
 (TCLP) TEST). DOCUMENTATION MUST ALSO BE PROVIDED THAT
 IDENTIFIES ALL COMPONENTS THAT ARE RECYCLABLE AND ALL
 COMPONENTS THAT CONSIST OF RECYCLED MATERIAL.
 PROVIDE STATEMENT FROM MANUFACTURER
  

Review Stop Z ZONING
Rev No 2 Status N Date 2019-05-17 Cont ID  
Sent By rcaranci Date 2019-05-17 Time 15:00 Rev Time 0.00
Received By rcaranci Date 2019-05-14 Time 15:01 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2019-04-22 Cont ID  
Sent By rcaranci Date 2019-04-22 Time 17:20 Rev Time 0.00
Received By rcaranci Date 2019-04-22 Time 17:20 Sent To  
Notes
***NONE***