Plan Review Details - Permit 19041027
Plan Review Stops For Permit 19041027 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-05-09 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-05-09 |
Time |
17:29 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-05-09 |
Time |
17:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-05-08 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-05-08 |
Time |
10:54 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-05-08 |
Time |
10:54 |
Sent To |
|
|
Notes |
2019-05-08 11:04:22 | ***CORRECTIONS*** | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | BUILDING PLAN REVIEW DENIED: | | | | FBC B 107.2.1 PLEASE PROVIDE THE MEASUREMENTS ON PLANS | | SHOWING COMPLIANCE WITH FAIR HOUSING CHAPTER 7 (USABLE | | KITCHENS) AND (USABLE BATHROOMS) CLEAR FLOOR SPACES. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2019-05-09 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-05-09 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-05-09 |
Time |
10:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2019-04-26 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-04-26 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2019-04-26 |
Time |
11:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-05-09 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2019-05-09 |
Time |
17:29 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2019-05-09 |
Time |
14:26 |
Sent To |
|
|
Notes |
2019-05-09 14:26:41 | RESUB ROUTED TO THUNT |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-05-09 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2019-05-09 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2019-04-19 |
Time |
13:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2019-05-09 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-05-09 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-05-09 |
Time |
15:13 |
Sent To |
B |
|
Notes |
2019-05-09 15:13:22 | ROUTED TO PV |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-04-30 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2019-04-30 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-04-30 |
Time |
15:10 |
Sent To |
|
|
Notes |
2019-04-30 15:11:13 | PLUMBING 1ST REVISION REVIEW**DENIED** | | | | NOTE: THIS BUILDING CONSTRUCTED IN 2006 WAS BUILT UNDER | | THE FAIR HOUSING ACT (FHA) THE APPROVED PLAN ON RECORD | | PROVIDE INFORMATION THAT HIS PLAN IS NOW MISSING. | | PLEASE FEEL FREE TO CALL AND DISCUSS IF NEEDED | | | | | | 1) THE MEASUREMENT FROM THE REFRIGERATOR WALL TO THE | | NEW ISLAND IS MISSING ON THIS REVISED PLAN. SHT. A300 | | OF THE CURRENT APPROVED PLAN LISTED AS 3'6" (42") UNDER | | FHA 7.7 THE MIN REQUIRED SPACE FROM THE EDGE OF THE | | REFRIGERATOR TO THE LEAD EDGE OF THE COUNTER TOP AND OR | | CABINET MUST BE 40". PLEASE PROVIDE WHAT THE | | MEASUREMENT IS. FBC 107.2.1 | | | | 2) PROVIDE CLEAR FLOOR SPACES @ ALL KITCHEN FIXTURES/ | | APPLIANCES TO INCLUDE. KITCHEN SINK, REFRIGERATOR, | | DISHWASHER, STOVE, AND THE RANGE. PLEASE REFER TO FHA | | 7.4, 7.5, 7.6 | | | | | | TIM HUNT | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | BUILDING DIVISION | | CITY OF WEST PALM BEACH | | 401 CLEMATIS STREET, 1ST FLOOR | | WEST PALM BEACH, FL 33401 | | 561-248-2703 | | [email protected] |
|
|
|
Account Summary | Usage Policy | Privacy Policy