Plan Review Details - Permit 19040734
Plan Review Stops For Permit 19040734
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-05-20 Cont ID  
Sent By jduprey Date 2019-05-20 Time 09:42 Rev Time 0.00
Received By jduprey Date 2019-05-20 Time 09:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-05-13 Cont ID  
Sent By jduprey Date 2019-05-13 Time 08:30 Rev Time 0.00
Received By jduprey Date 2019-05-13 Time 08:15 Sent To  
Notes
2019-05-13 08:33:55BUILDING PLAN REVIEW
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
  
 JOSEAN A. DUPREY
 BUILDING PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6716
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 1ST REVIEW
 RESULTS: DENIED
 YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED
 BELOW.
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. IS NOT CLEAR WHERE THE GAS TANK WILL BE SITTING,
 OVER A CONCRETE PAD? PLEASE CLARIFY. 107.2.1.3
 ADDITIONAL INFORMATION IS REQUIRED.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-05-18 Cont ID  
Sent By fgiaquin Date 2019-05-18 Time 12:26 Rev Time 0.00
Received By fgiaquin Date 2019-05-18 Time 12:02 Sent To G
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-05-08 Cont ID  
Sent By fgiaquin Date 2019-05-08 Time 17:45 Rev Time 0.00
Received By fgiaquin Date 2019-05-08 Time 17:18 Sent To  
Notes
2019-05-08 17:28:06ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ELECTRICAL PLAN IS REQUIRED TO BE DESIGNED AND
 SIGNED/SEALED BY A DESIGN PROFESSIONAL OR SIGNED BY THE
 ELECTRICAL CONTRACTOR QUALIFIER. PROVIDE CORRECTION. FS
 471.003(2)(H); 471.025; WPB FBC 107.1
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  
  

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2019-05-20 Cont ID  
Sent By thunt Date 2019-05-20 Time 13:45 Rev Time 0.00
Received By thunt Date 2019-05-20 Time 13:45 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2019-05-20 Cont ID  
Sent By thunt Date 2019-05-20 Time 08:35 Rev Time 0.00
Received By thunt Date 2019-05-20 Time 08:35 Sent To B
Notes
2019-05-20 08:44:06GAS 2ND REVIEW**DENIED**FL ST 553.80 (B)2B WITH RESPECT
 TO EVALUATION OF DESIGN PROFESSIONALS? DOCUMENTS, IF A
 LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO
 ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND
 ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY
 THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A
 CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN
 EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS,
 FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
  
  
 1) 2ND REQUEST. COPIES OF ANY SUBMITTAL DOCUMENTS THAT
 IS SIGNED OR BEAR THE TITLE BLOCK OF A DESIGN
 PROFESSIONAL MUST BE WET SIGNED. COPIES OF ANY
 SUBMITTAL DOCUMENTS OF A P.E SIGNATURE IS NOT
 PERMITTED. ANY FUTURE VIOLATION OF FAC 61G15-23.001
 WILL RESULT IN A COMPLAINT FILE WITH THE BOARD OF
 PROFESSIONAL ENGINEERS.
  
 2) HOLD DOWN DETAIL IS ILLEGIBLE. PROVIDE THE SIZE OF
 THE HOLD-DOWN CABLES/STRAPS FOR THE TANK AND THE TYPE
 AND LENGTH OF GROUND ANCHORS TO BE INSTALLED TO PREVENT
 FLOTATION. NFPA 58 SEC. 6.6.1.6.
  
 3) PROVIDE MANUFACTURES INSTALLATION MAUNAL FOR THE
 TANK VERIFY COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58,
 AND FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 GAS
 APPLIANCES SHALL BE LISTED AND LABELED
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 561-248-2703
 [email protected]
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-04-22 Cont ID  
Sent By thunt Date 2019-04-22 Time 14:42 Rev Time 0.00
Received By thunt Date 2019-04-22 Time 14:42 Sent To  
Notes
2019-04-22 14:42:04GAS 1ST REVIEW**DENIED**
  
 1) COPIES THAT BARE THE SIGNATURE FOR P.E GORDON
 DIBATISTO SHALL BE WET SIGNED. FAC 61G15-23.001
  
 2) HOLD DOWN DETAIL IS ILLEGIBLE. PROVIDE THE SIZE OF
 THE HOLD-DOWN CABLES/STRAPS FOR THE TANK AND THE TYPE
 AND LENGTH OF GROUND ANCHORS TO BE INSTALLED TO PREVENT
 FLOTATION. NFPA 58 SEC. 6.6.1.6.
  
 3) PROVIDE MANUFACTURES INSTALLATION MAUNAL FOR THE
 TANK VERIFY COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58,
 AND FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 GAS
 APPLIANCES SHALL BE LISTED AND LABELED
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 561-248-2703
 [email protected]
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-05-20 Cont ID  
Sent By thunt Date 2019-05-20 Time 13:44 Rev Time 0.00
Received By thunt Date 2019-05-20 Time 13:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-05-20 Cont ID  
Sent By jduprey Date 2019-05-20 Time 09:42 Rev Time 0.00
Received By jduprey Date 2019-05-16 Time 13:35 Sent To  
Notes
2019-05-17 13:35:21RESUB ROUTED TO FGIAQUINTO

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-05-13 Cont ID  
Sent By jduprey Date 2019-05-13 Time 08:34 Rev Time 0.00
Received By jduprey Date 2019-04-15 Time 11:26 Sent To  
Notes
2019-05-08 17:57:13TO MISC 2
  
2019-04-16 11:26:18ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 1 Status P Date 2019-04-19 Cont ID  
Sent By mcruz Date 2019-04-19 Time 15:18 Rev Time 0.00
Received By mcruz Date 2019-04-19 Time 15:17 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved