Plan Review Stops For Permit 19040734 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2019-05-20 |
|
|
Cont ID |
|
Sent By |
jduprey |
Date |
2019-05-20 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
jduprey |
Date |
2019-05-20 |
Time |
09:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-05-13 |
|
|
Cont ID |
|
Sent By |
jduprey |
Date |
2019-05-13 |
Time |
08:30 |
Rev Time |
0.00 |
Received By |
jduprey |
Date |
2019-05-13 |
Time |
08:15 |
Sent To |
|
|
Notes |
2019-05-13 08:33:55 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | JOSEAN A. DUPREY | | BUILDING PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6716 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 1ST REVIEW | | RESULTS: DENIED | | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED | | BELOW. | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | 1. IS NOT CLEAR WHERE THE GAS TANK WILL BE SITTING, | | OVER A CONCRETE PAD? PLEASE CLARIFY. 107.2.1.3 | | ADDITIONAL INFORMATION IS REQUIRED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2019-05-18 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2019-05-18 |
Time |
12:26 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2019-05-18 |
Time |
12:02 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-05-08 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2019-05-08 |
Time |
17:45 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2019-05-08 |
Time |
17:18 |
Sent To |
|
|
Notes |
2019-05-08 17:28:06 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. ELECTRICAL PLAN IS REQUIRED TO BE DESIGNED AND | | SIGNED/SEALED BY A DESIGN PROFESSIONAL OR SIGNED BY THE | | ELECTRICAL CONTRACTOR QUALIFIER. PROVIDE CORRECTION. FS | | 471.003(2)(H); 471.025; WPB FBC 107.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2017 6TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-657-1653 | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2019-05-20 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-05-20 |
Time |
13:45 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-05-20 |
Time |
13:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2019-05-20 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-05-20 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-05-20 |
Time |
08:35 |
Sent To |
B |
|
Notes |
2019-05-20 08:44:06 | GAS 2ND REVIEW**DENIED**FL ST 553.80 (B)2B WITH RESPECT | | TO EVALUATION OF DESIGN PROFESSIONALS? DOCUMENTS, IF A | | LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO | | ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND | | ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY | | THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A | | CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN | | EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS, | | FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | 1) 2ND REQUEST. COPIES OF ANY SUBMITTAL DOCUMENTS THAT | | IS SIGNED OR BEAR THE TITLE BLOCK OF A DESIGN | | PROFESSIONAL MUST BE WET SIGNED. COPIES OF ANY | | SUBMITTAL DOCUMENTS OF A P.E SIGNATURE IS NOT | | PERMITTED. ANY FUTURE VIOLATION OF FAC 61G15-23.001 | | WILL RESULT IN A COMPLAINT FILE WITH THE BOARD OF | | PROFESSIONAL ENGINEERS. | | | | 2) HOLD DOWN DETAIL IS ILLEGIBLE. PROVIDE THE SIZE OF | | THE HOLD-DOWN CABLES/STRAPS FOR THE TANK AND THE TYPE | | AND LENGTH OF GROUND ANCHORS TO BE INSTALLED TO PREVENT | | FLOTATION. NFPA 58 SEC. 6.6.1.6. | | | | 3) PROVIDE MANUFACTURES INSTALLATION MAUNAL FOR THE | | TANK VERIFY COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, | | AND FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 GAS | | APPLIANCES SHALL BE LISTED AND LABELED | | | | TIM HUNT | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | CITY OF WEST PALM BEACH | | 561-248-2703 | | [email protected] | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2019-04-22 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-04-22 |
Time |
14:42 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-04-22 |
Time |
14:42 |
Sent To |
|
|
Notes |
2019-04-22 14:42:04 | GAS 1ST REVIEW**DENIED** | | | | 1) COPIES THAT BARE THE SIGNATURE FOR P.E GORDON | | DIBATISTO SHALL BE WET SIGNED. FAC 61G15-23.001 | | | | 2) HOLD DOWN DETAIL IS ILLEGIBLE. PROVIDE THE SIZE OF | | THE HOLD-DOWN CABLES/STRAPS FOR THE TANK AND THE TYPE | | AND LENGTH OF GROUND ANCHORS TO BE INSTALLED TO PREVENT | | FLOTATION. NFPA 58 SEC. 6.6.1.6. | | | | 3) PROVIDE MANUFACTURES INSTALLATION MAUNAL FOR THE | | TANK VERIFY COMPLIANCE WITH STANDARDS NFPA 54, NFPA 58, | | AND FBC-2017 FUEL GAS CODE SEC. 402.2, AND 301.3 GAS | | APPLIANCES SHALL BE LISTED AND LABELED | | | | TIM HUNT | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | CITY OF WEST PALM BEACH | | 561-248-2703 | | [email protected] | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-05-20 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-05-20 |
Time |
13:44 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-05-20 |
Time |
13:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-05-20 |
|
|
Cont ID |
|
Sent By |
jduprey |
Date |
2019-05-20 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
jduprey |
Date |
2019-05-16 |
Time |
13:35 |
Sent To |
|
|
Notes |
2019-05-17 13:35:21 | RESUB ROUTED TO FGIAQUINTO |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-05-13 |
|
|
Cont ID |
|
Sent By |
jduprey |
Date |
2019-05-13 |
Time |
08:34 |
Rev Time |
0.00 |
Received By |
jduprey |
Date |
2019-04-15 |
Time |
11:26 |
Sent To |
|
|
Notes |
2019-05-08 17:57:13 | TO MISC 2 | | | 2019-04-16 11:26:18 | ROUTED TO ZONING INBOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2019-04-19 |
|
|
Cont ID |
|
Sent By |
mcruz |
Date |
2019-04-19 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
mcruz |
Date |
2019-04-19 |
Time |
15:17 |
Sent To |
|
|
Notes |
|
|