Plan Review Details - Permit 19040731
Plan Review Stops For Permit 19040731
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2019-06-10 Cont ID  
Sent By cthroop Date 2019-06-10 Time 15:44 Rev Time 0.00
Received By cthroop Date 2019-06-10 Time 15:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-06-04 Cont ID  
Sent By shill Date 2019-06-04 Time 15:22 Rev Time 0.00
Received By shill Date 2019-06-04 Time 15:22 Sent To  
Notes
2019-06-04 15:25:40****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. FBC 107, PROVIDE TWO COLLATED SETS OF PLANS FOR
 REVIEW. IT IS NOT CLEAR WHICH OF THE CONCRETE PADS IS
 PROPOSED. ASSEMBLE TWO IDENTICAL SETS OF PLANS FOR
 PERMIT ISSUANCE, AND MARK OTHER SHEETS "VOID".
  
 NOTE THAT SIGNED, SEALED ORIGINAL ENGINEERING IS
 REQUIRED (SOME OF THE ENGINEERING WAS ORIGINAL, SOME
 WERE COPIES).
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2019-05-13 Cont ID  
Sent By jduprey Date 2019-05-13 Time 10:32 Rev Time 0.00
Received By jduprey Date 2019-05-13 Time 10:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-06-03 Cont ID  
Sent By fgiaquin Date 2019-06-03 Time 06:25 Rev Time 0.00
Received By fgiaquin Date 2019-06-03 Time 05:50 Sent To G
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-05-08 Cont ID  
Sent By fgiaquin Date 2019-05-08 Time 17:13 Rev Time 0.00
Received By fgiaquin Date 2019-05-08 Time 16:52 Sent To  
Notes
2019-05-08 17:13:46ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ELECTRICAL PLAN IS REQUIRED TO BE DESIGNED AND
 SIGNED/SEALED BY A DESIGN PROFESSIONAL OR SIGNED BY THE
 ELECTRICAL CONTRACTOR QUALIFIER. PROVIDE CORRECTION. FS
 471.003(2)(H); 471.025; WPB FBC 107.1
  
 2. PROVIDE CUT SHEET OF TRANSFER SWITCH FOR PRODUCT
 APPROVAL. FBC 107.2.1 NEC 90.7, 110.2, 110.3B
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
 CODES IN EFFECT:
  
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2017 6TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 FRANK GIAQUINTO III
 ELECTRICAL INSPECTOR
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 [email protected]
 CELL: 561-657-1653
  

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2019-06-10 Cont ID  
Sent By thunt Date 2019-06-10 Time 15:13 Rev Time 0.00
Received By thunt Date 2019-06-10 Time 15:13 Sent To B
Notes
2019-06-10 15:14:27ROUTED TO C.T

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2019-06-04 Cont ID  
Sent By thunt Date 2019-06-04 Time 09:12 Rev Time 0.00
Received By thunt Date 2019-06-04 Time 09:12 Sent To B
Notes
2019-06-04 09:14:37GAS 2ND REVIEW**DENIED**
  
 RESUBMITTED PLANS ARE MIXED IN WITH OLD PLANS AND
 COMPLETELY DISORGANIZED. PLEASE REMOVE OR VOID OUT OLD
 PLANS AND SUBMIT 2 COMPLETE PLAN PACKETS. A REVIEW CAN
 NOT BE PERFORMED AT THIS TIME AS I HAVE NO CLEAR IDEA
 WHICH SET OF PLANS I AM LOOKING AT. FBC 107.3.5
  
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2019-04-22 Cont ID  
Sent By thunt Date 2019-04-22 Time 15:11 Rev Time 0.00
Received By thunt Date 2019-04-22 Time 15:11 Sent To  
Notes
2019-04-22 15:15:48GAS 1ST REVIEW**DENIED**
  
 1) COPIES THAT BARE THE SIGNATURE FOR P.E GORDON
 DIBATISTO SHALL BE WET SIGNED. FAC 61G15-23.001
  
 2) CITY RECORDS (PERMIT #16090271) LIST BTU AS 419,000.
 YOUR EXISTING LOAD ON SYSTEM IS 185,000. PLEASE CORRECT
 ISOMETRIC FORM. FBC_107.3.5
  
 3) CITY RECORDS (PERMIT) #16090271) SHOWS SYSTEM IS
 ALREADY A 2PSI. PLEASE CLAIRFY. FBC 107.2.1
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 CITY OF WEST PALM BEACH
 561-248-2703
 [email protected]
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-06-10 Cont ID  
Sent By cthroop Date 2019-06-10 Time 15:45 Rev Time 0.00
Received By cthroop Date 2019-06-06 Time 13:34 Sent To  
Notes
2019-06-07 13:35:09RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-06-04 Cont ID  
Sent By shill Date 2019-06-04 Time 15:25 Rev Time 0.00
Received By shill Date 2019-05-28 Time 10:15 Sent To  
Notes
2019-05-30 10:15:20RESUB ROUTED TO FGIAQUINTO

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-05-13 Cont ID  
Sent By jduprey Date 2019-05-13 Time 10:32 Rev Time 0.00
Received By jduprey Date 2019-04-15 Time 11:27 Sent To  
Notes
2019-05-08 17:58:41TO MISC 2
  
2019-04-16 11:27:49ROUTED TO ZONING INBOX

Review Stop Z ZONING
Rev No 1 Status P Date 2019-04-19 Cont ID  
Sent By mcruz Date 2019-04-19 Time 15:16 Rev Time 0.00
Received By mcruz Date 2019-04-19 Time 15:13 Sent To  
Notes
***NONE***