Plan Review Details - Permit 19040663
Plan Review Stops For Permit 19040663 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2019-07-05 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-07-05 |
Time |
08:01 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-06-25 |
Time |
10:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2019-06-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-06-10 |
Time |
18:23 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-06-10 |
Time |
09:31 |
Sent To |
|
|
Notes |
2019-06-10 09:57:48 | SECOND BUILDING REVIEW CHECKLIST. | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | NOTE: | | PLANS THAT WERE REVIEWED THE FIRST TIME WERE NOT | | RE-SUBMITTED. THIS MAKES THE REVIEW MORE DIFFICULT | | BECAUSE THERE IS NO REFERENCE OF WHAT WAS REVIEWED. IN | | THE FUTURE PLEASE SUBMIT THE PLANS THAT WERE REVIEWED | | TO HELP EXPEDITE THE REVIEW PROCESS. THANK YOU. | | | | | | | | 1) OK. | | | | ORIGINAL COMMENT: | | 2) THE COVERSHEET UNDER THE HEADING OCCUPANCY LOADS | | STATES THE CUSTOMER AREA AS BASED ON STANDING | | UNCONCENTRATED TABLES AND CHAIRS @ 15 SQ. FT. PER | | OCCUPANT. PLEASE REVIEW THE 2017 FBC-B | | TABLE 1004.1.2. | | ASSEMBLY WITHOUT FIXED SEATS | | CONCENTRATED (CHAIRS ONLY- NOT FIXED 7 NET | | STANDING SPACE 5 NET | | UNCONCENTRATED (TABLES & CHAIRS) 15 NET | | | | YOU NEED TO DECIDE IF YOU ARE TAKING THE SQUARE FEET AT | | STANDING 441/5= 89 OCCUPANTS REQUIRING 2 EXITS. | | OR | | IF YOU ARE TAKING THE UNCONCENTRATED (TABLES & CHAIRS) | | @ 15 NET. 441/15=30 OCCUPANTS. | | | | RESPONSEE: | | REVISED CALCULATIONS SHOW 10 PEOPLE AS THE TOTAL NUMBER | | OF PEOPLE. THIS IS INCORRECT. THE OCCUPANT LOAD IS | | BASED ON THE ACTUAL FUNCTION OF EACH SPACE AS REQUIRED | | BY TABLE 1004.1.2 FBC-BUILDING. PROVIDE THE OCCUPANT | | LOAD OF EACH ROOM OR AREA AS REQUIRED BY SEC. | | 1004.1.1.1 FBC-BUILDING, THEN ADD THEM UP AND PROVIDE | | THE TOTAL OCCUPANT LOAD. | | NOTE: THE BUSINESS CLASSIFICATION IS JUST FOR THE | | OCCUPANCY CLASSIFICATION SINCE THIS IS AN SMALL | | ASSEMBLY GROUP WITH AN OCCUPANT LOAD OF LESS THAN 50 | | PEOPLE. OCCUPANT LOAD IS ALWAYS CALCULATED USING TABLE | | 1004.1.2. | | | | ORIGINAL COMMENT: | | 3) PLEASE NOTE ON THE COVER SHEET THE DESIGNER OF | | RECORD HAS THE NUMBER OF EXITS REQUIRED AS 1 BUT 2 | | PROVIDED AND THE MAXIMUM TRAVEL DISTANCE OF 27 FEET 6 | | INCHES. IF THE TRAVEL DISTANCE IS GOING TO BE TAKEN | | FROM THE MIDDLE OF THE FLOOR REQUIRING THE 2 EXITS, | | THEN SHOW COMPLIANCE WITH: | | 2017 ACCESS. CODE 206.4.1 PUBLIC ENTRANCES. IN ADDITION | | TO ENTRANCES REQUIRED BY 206.4.2 THROUGH 206.4.9, AT | | LEAST 60 PERCENT OF ALL PUBLIC ENTRANCES SHALL COMPLY | | WITH 404. | | | | 2017 FBC-ACCESSIBILITY CODE SECTION 207.1 MEANS OF | | EGRESS SHALL COMPLY WITH SECTION 1003.2.13 OF THE | | INTERNATIONAL BUILDING CODE (2000 EDITION AND 2001 | | SUPPLEMENT) OR SECTION 1007 OF THE INTERNATIONAL | | BUILDING CODE (2003 EDITION). | | | | 2003 IBC-B 1007.1 WHERE MORE THAN ONE MEANS OF EGRESS | | IS REQUIRED BY SECTIONS 1014.1 OR 1018.1 FROM ANY | | ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE | | SHALL BE SERVED BY NOT LESS THAN TWO MEANS OF EGRESS. | | THERE IS AT LEAST A 6 INCH DROP OUT THE BACK DOOR TO | | THE COURTYARD DECK MAKING IT NOT ABLE TO BE AN | | ACCESSIBLE MEANS OF EGRESS. | | | | RESPONSE: | | A)THE MEASUREMENT OF THE TRAVEL DISTANCE IS TAKEN FROM | | THE MOST REMOTE POINT TO THE ENTRANCE TO AN EXIT. SEE | | SEC. 1017.3 FBC-BUILDING. LIFE SAFETY PLAN ON SHEET A-1 | | SHOWS THE DISTANCE FROM THE REAR DOOR TO THE ENTRY | | DOOR. CLARIFY WHY MEASURING THE DISTANCE FROM ONE DOOR | | TO THE OTHER. IT LOOKS LIKE THE MOST REMOTE POINT WOULD | | BE THE FREEZER. REVISE AS REQUIRED. | | | | B) REVISE THE EGRESS WIDTH INFORMATION SHOWN ON SHEET | | CVR: | | (1)REVISE THE NUMBER OF OCCUPANTS. SEE RESPONSE TO | | COMMENT #2 ABOVE AND REVISE THE EGRESS WIDTH PROVIDED. | | 36" PROVIDED IS INCORRECT. THE WIDTH PROVIDED IS THE | | CLEAR WIDTH OPENING NOT THE SIZE OF THE DOOR. SEE SEC. | | 1010.1.1 FBC-BUILDING FOR PROPER WAY OF DIMENSIONING | | THE CLEAR WIDTH AND REVISE AS REQUIRED. TYPICALLY A 36" | | DOOR WOULD PROVIDE 32" CLEAR WIDTH OPENING. NOTE: | | PROVIDE THE SIZE OF THE EXISTING DOORS. DORO SCHEDULE | | DOESN'T SPECIFY THE SIZE OF THE EXISTING DOORS. THIS | | INFORMATION IS REQUIRED. | | | | (1)THERE IS NOT TABLE 1005.1 IN TH FBC-BUILDING CODE. | | | | | | 4) OK. ARCHITECT'S RESPONSE LETTER STATES THAT " THE | | TENANT DOES NOT INTEND TO USE THE COURTYARD FOR | | SEASONAL SEATING". | | | | 4A) OK. | | | | 4B) OK. | | | | 4C) OK. | | | | 4D)OK. | | | | ORIGINAL COMMENT: | | 4D)(1) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR | | SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD | | APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE | | COMPLYING WITH 306 SHALL BE PROVIDED. | | | | RESPONSE: | | KNEE AND TOE CLEARANCES WERE NOT PROVIDED. THERE ARE NO | | DETAILS FOR FRONT COUNTER AND PICK UP COUNTER BY THE | | PREP/SERV AREA. | | ALSO, CLARIFY WHERE DOES RECEPTION COUNTER ADA DETAIL | | 5/A-2 APPLIES TO?. SEC. 107.2.1 CITY AMENDMENTS. | | | | ORIGINAL COMMENT: | | 4D)(2) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND | | WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES | | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | RESPONS: | | THE HEIGHT OF THE PICK UP COUNTER DOESN'T COMPLY. | | REVISE AS REQUIRED. | | ALSO, CLARIFY WHERE DOES RECEPTION COUNTER ADA DETAIL | | 5/A-2 APPLIES TO?. SEC. 107.2.1 CITY AMENDMENTS. | | | | ORIGINAL COMMENT: | | 5) THE VALUE FOR THIS PERMIT IS EXTREMELY LOW | | CONSIDERING ALL OF THE KITCHEN EQUIPMENT THAT IS GOING | | INTO THIS SPACE AND THE REQUIRED GREASE TRAP. 109.3* | | BUILDING PERMIT VALUATION. | | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE | | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, | | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS | | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE | | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE | | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR | | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR | | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING | | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS | | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE | | CONGRESS. | | | | THIS MAIN BUILDING PERMIT WILL INCLUDE THE FEES FOR THE | | MECHANICAL, ELECTRICAL, PLUMBING & ROOFING PERMITS. | | WHEN THE GENERAL CONTRACTOR COMES IN FOR A BUILDING | | PERMIT WITH THE SIGNED PERMIT APPLICATION FORM BY THE | | QUALIFIER AND OWNER AND BRINGS IN THE LISTED | | SUB-PERMITS M-E-P & ROOFING PERMITS SIGNED BY THE | | QUALIFIER OF EACH COMPANY, THEIR INSURANCES AND | | LICENSURE UP TO DATE, THE M-E-P AND ROOFING PERMITS ARE | | FREE OF CHARGE. IF THE M-E-P & ROOFING PERMITS COME IN | | LATER THERE WILL BE AN $80.00 ADMINISTRATIVE FEE FOR | | EACH PERMIT. | | | | ALL OTHER PERMITS FIRE SPRINKLER, FIRE ALARM, RACK | | STORAGE, EXHAUST HOODS, ANSUL SYSTEMS OR ALTERNATIVE | | AUTOMATIC FIRE-EXTINGUISHING SYSTEMS, WALK IN COOLERS & | | FREEZERS, ALL LOW VOLTAGE PERMITS, GENERATORS & FUEL | | TANKS, GAS PERMIT, POOL, JACUZZI AND ASSOCIATED | | SUB-PERMITS, AWNING, SCREEN ENCLOSURES, CANOPY, FENCE, | | LANDSCAPE, IRRIGATION, AUGER CAST PILE AND OR | | FOUNDATION OR STRUCTURE ONLY PERMIT WILL BE SEPARATE | | REVIEWS AND ASSOCIATED FEES WITH EACH PERMIT. | | PLEASE PROVIDE AN ITEMIZED LIST AND SUBTRACT THESE LINE | | ITEMS AND THEIR VALUE FROM THE OVERALL BUILDING VALUE | | STATED ON THE PERMIT APPLICATION FOR THIS PROJECT. THE | | REMAINING BALANCE WILL BE AFFECTIVELY THE VALUE OF THE | | BUILDING YOU WILL BE PAYING FOR THIS PERMIT. THE | | BUILDING DEPARTMENT DOES NOT WANT TO COLLECT TWICE FOR | | THE VALUE OF THESE SUB-PERMITS NOT COVERED UNDER THE | | PRIME OR MASTER PERMIT. | | | | RESPONSE: | | PLEASE PROVIDE THE ITEMIZED LIST REQUESTED BY THE | | PREVIOUS PLANS EXAMINER. INLCUDE THE DESIGN | | PROFESSIONAL FEES. | | | | | | ORIGINAL COMMENT: | | 6) PLEASE PROVIDE THE DIMENSION OF THE EXISTING | | RESTROOM TO SEE IF THE RESTROOM COMPLIES WITH THE 2017 | | FBC-ACCESSIBILITY CODE? 107.2.1.2 ADDITIONAL | | INFORMATION IS REQUIRED. | | | | RESPONSE: | | ARCHITECT'S RESPONSE LETTER STATES THAT THE RESTROOM | | DESIGN HAS BEEN REVISED TO CONFORM TO THE 2017 | | FBC-ACCESSIBILITY CODE". | | FLOOR PLANS WERE REVISED BUT IS NOT CLEAR WHAT WALLS | | ARE NEW AND WHAT WALLS ARE EXISTING. PLEASE COORDINATE | | WITH THE WALL PLAN LEGEND AND REVISE ACCORDINGLY TO | | AVOID CONFUSION. SEC. 107.2.1 CITY AMENDMENTS. | | | | | | 7) OK. | | | | ORIGINAL COMMENT: | | 8) SHEET A-1 SHOWS UNDER THE STAIR STORAGE. PLEASE SHOW | | HOW COMPLIANCE WITH THE 2017 FBC-B SECTION | | 1011.7.3 ENCLOSURES UNDER INTERIOR STAIRWAYS. THE WALLS | | AND SOFFITS WITHIN ENCLOSED USABLE SPACES UNDER | | ENCLOSED AND UNENCLOSED STAIRWAYS SHALL BE PROTECTED BY | | 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION OR THE | | FIRE-RESISTANCE RATING OF THE STAIRWAY ENCLOSURE, | | WHICHEVER IS GREATER. | | | | RESPONSE: | | DETAIL PROVIDED ON SHEET A-1 DOESN'T SEEM TO APPLY TO | | THE EXISTING CONDITIONS. PROVIDE DETAIL THAT MATCHES | | EXISTING CONDITIONS. SEC. 107.2.1 CITY AMENDMENTS. | | | | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. SUBMIT OLD DRAWINGS FOR REFERENCE. (PLEASE | | DON'T STAPLE OLD DRAWINGS TO RESUBMITTED PACKAGE). A | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 10- A NEW CERTIFICATE OF OCCUPANCY WILL BE REQUIRED | | AFTER COMPLETION OF WORK. | | SEC. 1001.2 FBC-EXISTING BUILDING. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-04-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2019-04-30 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2019-04-30 |
Time |
09:46 |
Sent To |
|
|
Notes |
2019-04-30 12:34:58 | 2017 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 19040663 | | ADD: 513 CLEMATIS ST. / SUITE: 103 | | CONT: TBD/ TO BE DETERMINED | | TEL: 314-397-9047 | | E-MAIL: [email protected] | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: TUES. APRIL 20/ 2019 | | ACTION: DENIED | | | | 1) THIS REVIEW, BUILDING WILL BE REVIEWING THIS TENANT | | SPACE AS A BUSINESS OCCUPANCY. THE USE BEFORE PERMITTED | | AS A BUSINESS OCCUPANCY (13070239/ 2010 FBC-B 303.1 | | EXCEPT. 2) OCCUPANT LOAD LESS THAN 50. SHEET A-1 UNDER | | EGRESS AND LIFE SAFETY NOTES INDICATES A MERCANTILE | | OCCUPANCY WHERE A ON THIS SAME PAGE THE FLAME SPREAD | | RATINGS ARE TAKEN FOR A BUSINESS OCCUPANCY. DISCREPANCY | | IN THE OCCUPANCY TYPE? | | 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED. | | | | 2) THE COVERSHEET UNDER THE HEADING OCCUPANCY LOADS | | STATES THE CUSTOMER AREA AS BASED ON STANDING | | UNCONCENTRATED TABLES AND CHAIRS @ 15 SQ. FT. PER | | OCCUPANT. PLEASE REVIEW THE 2017 FBC-B | | TABLE 1004.1.2. | | ASSEMBLY WITHOUT FIXED SEATS | | CONCENTRATED (CHAIRS ONLY- NOT FIXED 7 NET | | STANDING SPACE 5 NET | | UNCONCENTRATED (TABLES & CHAIRS) 15 NET | | | | YOU NEED TO DECIDE IF YOU ARE TAKING THE SQUARE FEET AT | | STANDING 441/5= 89 OCCUPANTS REQUIRING 2 EXITS. | | OR | | IF YOU ARE TAKING THE UNCONCENTRATED (TABLES & CHAIRS) | | @ 15 NET. 441/15=30 OCCUPANTS | | | | 3) PLEASE NOTE ON THE COVER SHEET THE DESIGNER OF | | RECORD HAS THE NUMBER OF EXITS REQUIRED AS 1 BUT 2 | | PROVIDED AND THE MAXIMUM TRAVEL DISTANCE OF 27 FEET 6 | | INCHES. IF THE TRAVEL DISTANCE IS GOING TO BE TAKEN | | FROM THE MIDDLE OF THE FLOOR REQUIRING THE 2 EXITS, | | THEN SHOW COMPLIANCE WITH: | | 2017 ACCESS. CODE 206.4.1 PUBLIC ENTRANCES. IN ADDITION | | TO ENTRANCES REQUIRED BY 206.4.2 THROUGH 206.4.9, AT | | LEAST 60 PERCENT OF ALL PUBLIC ENTRANCES SHALL COMPLY | | WITH 404. | | | | 2017 FBC-ACCESSIBILITY CODE SECTION 207.1 MEANS OF | | EGRESS SHALL COMPLY WITH SECTION 1003.2.13 OF THE | | INTERNATIONAL BUILDING CODE (2000 EDITION AND 2001 | | SUPPLEMENT) OR SECTION 1007 OF THE INTERNATIONAL | | BUILDING CODE (2003 EDITION). | | | | 2003 IBC-B 1007.1 WHERE MORE THAN ONE MEANS OF EGRESS | | IS REQUIRED BY SECTIONS 1014.1 OR 1018.1 FROM ANY | | ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE | | SHALL BE SERVED BY NOT LESS THAN TWO MEANS OF EGRESS. | | THERE IS AT LEAST A 6 INCH DROP OUT THE BACK DOOR TO | | THE COURTYARD DECK MAKING IT NOT ABLE TO BE AN | | ACCESSIBLE MEANS OF EGRESS. | | | | 4) IF THE TENANT INTENDS TO USE THE COURTYARD AREA FOR | | SEASONAL SEATING, THEN THE BACK DOOR WILL NEED TO HAVE | | AN UPPER LANDING AND AN ACCESSIBLE RAMP TO THE | | COURTYARD AREA. HANDRAILS MAYBE REQUIRED ON THE | | DIFFERENCE IN GRADE. | | 4A) 226.1 WHERE DINING SURFACES ARE PROVIDED FOR THE | | CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE | | SEATING SPACES AND STANDING SPACES AT THE DINING | | SURFACES SHALL COMPLY WITH 902. | | | | 4B) 226.2 DISPERSION. DINING SURFACES REQUIRED TO | | COMPLY WITH 902 SHALL BE DISPERSED THROUGHOUT THE SPACE | | OR FACILITY CONTAINING DINING SURFACES AND WORK | | SURFACES. | | | | 4C) 206.2.5 206.2.5 RESTAURANTS AND CAFETERIAS. IN | | RESTAURANTS AND CAFETERIAS, AN ACCESSIBLE ROUTE SHALL | | BE PROVIDED TO ALL DINING AREAS, INCLUDING RAISED OR | | SUNKEN DINING AREAS, AND OUTDOOR DINING AREAS. | | | | 4D) 902.1 .DINING SURFACES SHALL COMPLY WITH 902.2 AND | | 902.3. ADVISORY 902.1 GENERAL. DINING SURFACES INCLUDE, | | BUT ARE NOT LIMITED TO, BARS, TABLES, LUNCH COUNTERS, | | AND BOOTHS | | | | 4D)(1) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR | | SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD | | APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE | | COMPLYING WITH 306 SHALL BE PROVIDED. | | | | 4D)(2) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND | | WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES | | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. | | | | 5) THE VALUE FOR THIS PERMIT IS EXTREMELY LOW | | CONSIDERING ALL OF THE KITCHEN EQUIPMENT THAT IS GOING | | INTO THIS SPACE AND THE REQUIRED GREASE TRAP. 109.3* | | BUILDING PERMIT VALUATION. | | IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE | | CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE, | | ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS | | APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE | | PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES, | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL | | REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE | | STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR | | FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR | | BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING | | COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS | | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE | | CONGRESS. | | | | THIS MAIN BUILDING PERMIT WILL INCLUDE THE FEES FOR THE | | MECHANICAL, ELECTRICAL, PLUMBING & ROOFING PERMITS. | | WHEN THE GENERAL CONTRACTOR COMES IN FOR A BUILDING | | PERMIT WITH THE SIGNED PERMIT APPLICATION FORM BY THE | | QUALIFIER AND OWNER AND BRINGS IN THE LISTED | | SUB-PERMITS M-E-P & ROOFING PERMITS SIGNED BY THE | | QUALIFIER OF EACH COMPANY, THEIR INSURANCES AND | | LICENSURE UP TO DATE, THE M-E-P AND ROOFING PERMITS ARE | | FREE OF CHARGE. IF THE M-E-P & ROOFING PERMITS COME IN | | LATER THERE WILL BE AN $80.00 ADMINISTRATIVE FEE FOR | | EACH PERMIT. | | | | ALL OTHER PERMITS FIRE SPRINKLER, FIRE ALARM, RACK | | STORAGE, EXHAUST HOODS, ANSUL SYSTEMS OR ALTERNATIVE | | AUTOMATIC FIRE-EXTINGUISHING SYSTEMS, WALK IN COOLERS & | | FREEZERS, ALL LOW VOLTAGE PERMITS, GENERATORS & FUEL | | TANKS, GAS PERMIT, POOL, JACUZZI AND ASSOCIATED | | SUB-PERMITS, AWNING, SCREEN ENCLOSURES, CANOPY, FENCE, | | LANDSCAPE, IRRIGATION, AUGER CAST PILE AND OR | | FOUNDATION OR STRUCTURE ONLY PERMIT WILL BE SEPARATE | | REVIEWS AND ASSOCIATED FEES WITH EACH PERMIT. | | PLEASE PROVIDE AN ITEMIZED LIST AND SUBTRACT THESE LINE | | ITEMS AND THEIR VALUE FROM THE OVERALL BUILDING VALUE | | STATED ON THE PERMIT APPLICATION FOR THIS PROJECT. THE | | REMAINING BALANCE WILL BE AFFECTIVELY THE VALUE OF THE | | BUILDING YOU WILL BE PAYING FOR THIS PERMIT. THE | | BUILDING DEPARTMENT DOES NOT WANT TO COLLECT TWICE FOR | | THE VALUE OF THESE SUB-PERMITS NOT COVERED UNDER THE | | PRIME OR MASTER PERMIT. | | | | 6) PLEASE PROVIDE THE DIMENSION OF THE EXISTING | | RESTROOM TO SEE IF THE RESTROOM COMPLIES WITH THE 2017 | | FBC-ACCESSIBILITY CODE? 107.2.1.2 ADDITIONAL | | INFORMATION IS REQUIRED. | | | | 7) PLEASE PROVIDE COMPLIANCE WITH THE 2017 | | FBC-ACCESSIBILITY CODE SECTION: | | 202.4.1 DISPROPORTIONATE COST. ALTERATIONS MADE TO | | PROVIDE AN ACCESSIBLE PATH OF TRAVEL TO THE ALTERED | | AREA WILL BE DEEMED DISPROPORTIONATE TO THE OVERALL | | ALTERATION WHEN THE COST EXCEEDS 20% OF THE COST OF THE | | ALTERATION TO THE PRIMARY FUNCTION AREA. | | | | 202.4.2 ACCESSIBLE FEATURES IN THE EVENT OF | | DISPROPORTIONALITY. WHEN THE COST OF ALTERATIONS | | NECESSARY TO MAKE THE PATH OF TRAVEL TO THE ALTERED | | AREA FULLY ACCESSIBLE IS DISPROPORTIONATE TO THE COST | | OF THE OVERALL ALTERATION, THE PATH OF TRAVEL SHALL BE | | MADE ACCESSIBLE TO THE EXTENT THAT IT CAN BE MADE | | ACCESSIBLE WITHOUT INCURRING DISPROPORTIONATE COSTS. IN | | CHOOSING WHICH ACCESSIBLE ELEMENTS TO PROVIDE, PRIORITY | | SHOULD BE GIVEN TO THOSE ELEMENTS THAT WILL PROVIDE THE | | GREATEST ACCESS, IN THE FOLLOWING ORDER: (I) AN | | ACCESSIBLE ENTRANCE; (II) AN ACCESSIBLE ROUTE TO THE | | ALTERED AREA; (III) AT LEAST ONE ACCESSIBLE RESTROOM | | FOR EACH SEX OR A SINGLE UNISEX RESTROOM; (IV) | | ACCESSIBLE TELEPHONES; (V) ACCESSIBLE DRINKING | | FOUNTAINS; AND (VI) WHEN POSSIBLE, ADDITIONAL | | ACCESSIBLE ELEMENTS SUCH AS PARKING, STORAGE, AND | | ALARMS. | | | | EITHER THE DESIGNER OF RECORD OR CONTRACTOR ON THEIR | | LETTERHEAD CAN SHOW WHERE 0.20 % OF THE VALUE OF THE | | PROJECT, THIS ENCLUDESDESIGN FEES, IS GOING TO MAKE | | THIS UNIT ACCESSIBLE. | | | | 8) SHEET A-1 SHOWS UNDER THE STAIR STORAGE. PLEASE SHOW | | HOW COMPLIANCE WITH THE 2017 FBC-B SECTION | | 1011.7.3 ENCLOSURES UNDER INTERIOR STAIRWAYS. THE WALLS | | AND SOFFITS WITHIN ENCLOSED USABLE SPACES UNDER | | ENCLOSED AND UNENCLOSED STAIRWAYS SHALL BE PROTECTED BY | | 1-HOUR FIRE-RESISTANCE-RATED CONSTRUCTION OR THE | | FIRE-RESISTANCE RATING OF THE STAIRWAY ENCLOSURE, | | WHICHEVER IS GREATER. | | | | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2019-07-12 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-07-12 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-07-12 |
Time |
07:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2019-05-31 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2019-05-31 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2019-05-31 |
Time |
11:10 |
Sent To |
|
|
Notes |
2019-05-31 11:10:43 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | 250.50, 250.94, 408.30 | | 2. PROVIDE ACCURATE LOAD CALCULATION FOR COMMERCIAL | | SERVICE INCLUDING ALL LOADS. NEC 220; WPB FBC 107.2.1 | | 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10 | | 10. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS, | | DAS, LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | SYSTEMS, WALK IN COOLERS, SIGNS, SITE LIGHTING, AND | | SWIMMING POOLS (WHERE APPLICABLE) ARE NOT INCLUDED IN | | THE SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE | | INDICATING THE REQUIRED SEPARATE PERMITS AND PLAN | | SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. WPB FBC | | 105.1, 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | PHIL PETTY | | ELECTRICAL PLANS EXAMINER | | 561-805-6742 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-05-07 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-05-07 |
Time |
15:55 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-05-07 |
Time |
14:27 |
Sent To |
|
|
Notes |
2019-05-07 15:54:57 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | 250.50, 250.94, 408.30 | | 2. PROVIDE ACCURATE LOAD CALCULATION FOR COMMERCIAL | | SERVICE INCLUDING ALL LOADS. NEC 220; WPB FBC 107.2.1 | | 3. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR | | SERVICE INCLUDING INFORMATION FROM THE POWER COMPANY | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | SERVICE EQUIPMENT IS ADEQUATE. NEC 110.9, 110.10 | | 4. PROVIDE GFCI PROTECTION FOR ALL RECEPTACLES IN FOOD | | PREP / KITCHEN AREAS. NEC 210.8 | | 5. PROVIDE THE ADDITIONAL AUTOMATIC LIGHTING CONTROLS | | STIPULATED IN THE FBC ENERGY CODE. FBC EC C405.2 | | 6. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES | | EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN | | RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR | | LIGHTING PROPOSED TO COMPLY WITH CODE. FBC EC C405.4.2 | | 7. NOTE 1 STATES THE 2010 FBC AS BASIS OF DESIGN. | | PROVIDE CORRECTION. FBC PREFACE | | 8. SOME OF THE ELECTRICAL NOTES ARE THOSE USED FOR | | RESIDENTIAL APPLICATIONS. REMOVE ANY NOTES NOT | | PERTAINING TO THIS JOB. WPB FBC 107.2.1 | | 9. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | 109.3 | | 10. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS, | | DAS, LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | SYSTEMS, WALK IN COOLERS, SIGNS, SITE LIGHTING, AND | | SWIMMING POOLS (WHERE APPLICABLE) ARE NOT INCLUDED IN | | THE SCOPE OF THIS PLAN REVIEW. PROVIDE A BLOCK NOTE | | INDICATING THE REQUIRED SEPARATE PERMITS AND PLAN | | SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. WPB FBC | | 105.1, 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2019-07-08 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-07-08 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-07-08 |
Time |
14:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2019-05-23 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-05-23 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-05-23 |
Time |
14:53 |
Sent To |
|
|
Notes |
2019-05-23 15:30:56 | 5/23/19 | | | | IN A EFFORT TO MOVE THIS PROJECT FORWARD THE FOLLOWING | | WAS PROVIOSED | | | | | | 1) SHEET CVR - YOUR OCCUPANCY CLASSIFICATION WAS | | MODIFIED AND LOADS RECLACULATED PER THE FLORIDA FIRE | | PREVENTION CODE. | | | | USING A BUSINESS OCCUPANCY CALCULATION OF 10 FOR THIS | | ENTIRE SPACE IS AN INCORRECT APPLICATION OF THE CODE. | | | | THIS IS AN ASSEMBLY OCCUPANCY WITH LESS THAN 50 PERSON, | | AND THUSLY MERCANTILE PER THE FFPC. | | | | THE OCCUPANCY LOAD CALCULATION; HOWEVER, DOES NOT | | CHANGE FOR THE ASSEMBLY SPACE. | | | | YOU WERE GIVEN CREDIT FOR BUSINESS, KITCHEN AND STORAGE | | USE FORMULAS IN THOSE OTHER APPLICABLE AREAS . | | | | YOUR TOTAL OCCUPANCY LOAD IS 31. | | | | | | 2) SHOULD YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE | | CONTACT MY OFFICE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2019-05-01 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-05-01 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-05-01 |
Time |
14:03 |
Sent To |
|
|
Notes |
2019-05-01 14:20:08 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | 1) SHEET CVR & A 1 - THERE IS AN INDICATION OF ONE EXIT | | REQUIRED AND TWO PROVIDED. SHEET A 1 INDICATES THAT THE | | BATHROOM AND OFFICE DOORS OPEN INTO THE EXIT CORRIDOR | | ENCROACHING INTO THE REQUIRED EGRESS WIDTH. | | | | PER NFPA 101, CH 7, MEANS OF EGRESS | | | | 7.2.1.4.3 DOOR LEAF ENCROACHMENT | | 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS | | OF EGRESS SHALL LEAVE NOT LESS THAN ONE-HALF OF THE | | REQUIRED WIDTH OF AN AISLE, A CORRIDOR, A PASSAGEWAY, | | OR A LANDING UNOBSTRUCTED AND SHALL NOT PROJECT NOT | | MORE THAN 7 IN. INTO THE REQUIRED WIDTH OF AN AISLE, A | | CORRIDOR, A PASSAGE WAY, OR A LANDING, WHEN FULLY OPEN, | | UNLESS BOTH OF THE FOLLOWING CONDITIONS ARE MET: | | (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN | | EXISTING BUILDING. | | (2) THE DOOR OPENING MEETS THE REQUIREMENTS THAT LIMITS | | PROJECTION TO NOT MORE THAN 7 IN. INTO THE REQUIRED | | WIDTH OF THE STAIR LANDING WHEN THE DOOR | | LEAF IS FULLY OPEN. | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | 2) SHEET E 1 & A 1 - THERE ARE NO INDICTIONS, EXISTING | | OR PROPOSED, OF EXITS SIGNS OVER THE EXIT DOORS. | | | | PER NFPA 101 CH 7, MEANS OF EGRESS | | | | 7.10 MARKING OF MEANS OF EGRESS. | | 7.10.1 GENERAL. | | 7.10.1.1 WHERE REQUIRED. MEANS OF EGRESS SHALL BE | | MARKED IN | | ACCORDANCE WITH SECTION 7.10 WHERE REQUIRED IN CHAPTERS | | 11 | | THROUGH 43. | | 7.10.1.2 EXITS. | | 7.10.1.2.1* EXITS, OTHER THAN MAIN EXTERIOR EXIT DOORS | | THAT OBVIOUSLY | | AND CLEARLY ARE IDENTIFIABLE AS EXITS, SHALL BE MARKED | | BY AN APPROVED | | SIGN THAT IS READILY VISIBLE FROM ANY DIRECTION OF EXIT | | ACCESS. | | | | PER NFPA 101, NEW MERCANTILE OCCUPANCIES | | | | 36.2.8 ILLUMINATION OF MEANS OF EGRESS. MEANS OF EGRESS | | SHALL | | BE ILLUMINATED IN ACCORDANCE WITH SECTION 7.8. | | | | 7.8 ILLUMINATION OF MEANS OF EGRESS. | | 7.8.1 GENERAL. | | 7.8.1.1* ILLUMINATION OF MEANS OF EGRESS SHALL BE | | PROVIDED IN | | ACCORDANCE WITH SECTION 7.8 FOR EVERY BUILDING AND | | STRUCTURE WHERE | | REQUIRED IN CHAPTERS 11 THROUGH 43. FOR THE PURPOSES OF | | THIS | | REQUIREMENT, EXIT ACCESS SHALL INCLUDE ONLY DESIGNATED | | STAIRS, AISLES, | | CORRIDORS, RAMPS, ESCALATORS, AND PASSAGEWAYS LEADING | | TO AN EXIT. FOR THE | | PURPOSES OF THIS REQUIREMENT, EXIT DISCHARGE SHALL | | INCLUDE ONLY | | DESIGNATED STAIRS, AISLES, CORRIDORS, RAMPS, | | ESCALATORS, WALKWAYS, AND EXIT | | PASSAGEWAYS LEADING TO A PUBLIC WAY. | | 7.8.1.2 ILLUMINATION OF MEANS OF EGRESS SHALL BE | | CONTINUOUS DURING THE | | TIME THAT THE CONDITIONS OF OCCUPANCY REQUIRE THAT THE | | MEANS OF EGRESS | | BE AVAILABLE FOR USE, UNLESS OTHERWISE PROVIDED IN | | 7.8.1.2.2. | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | 3) SHEET A 1 - THERE IS AN INCORRECT REFERENCE, 2014, | | OF NFPA. IS THIS REFERENCE A GENERAL REFERENCE OR | | SPECIFIC ONE? | | | | THE CURRENT EDITION OF NFPA 1 PER THE FLORIDA FIRE | | PREVENTION CODE IS 2015. | | | | PLEASE REVIEW ANC CLARIFY AND/OR CORRECT. | | | | | | | | 4) SHEET CVR - THE IS AN INDICATION UNDER CODE RESEACH: | | OCCUPANCY, OF BUSINESS (B GROUP) | | | | PER THE FLORIDA FIRE PREVENTION CODE THIS WOULD BE | | CONSIDERED A MERCANTILE OCCUPANCY;(ASSEMBLY LESS THAN | | 50) | | | | PLEASE REVIEW AND PROVIDE A CARRECTIVE NOTE FOR THE | | FFPC AND ENSURE COMPLIANCE. | | | | | | | | 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
N |
Date |
2019-07-12 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2019-07-12 |
Time |
16:24 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2019-07-12 |
Time |
16:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2019-06-04 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2019-06-04 |
Time |
11:30 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2019-06-04 |
Time |
11:30 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2019-05-09 |
|
|
Cont ID |
|
Sent By |
fmittner |
Date |
2019-05-09 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
fmittner |
Date |
2019-05-09 |
Time |
09:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-07-15 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-06-20 |
Time |
12:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-06-13 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2019-06-13 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-05-21 |
Time |
14:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-05-09 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2019-05-09 |
Time |
10:17 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2019-04-15 |
Time |
14:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2019-04-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2019-04-30 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2019-04-30 |
Time |
09:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2019-07-15 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-07-15 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-07-10 |
Time |
10:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2019-06-11 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-06-11 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-06-11 |
Time |
11:42 |
Sent To |
|
|
Notes |
2019-06-11 12:04:06 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #19040663 | | 6/11/19 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SEPARATE PERMITS ARE REQUIRED FOR THE WALK-IN | | FREEZER AND ANY PROPOSED KITCHEN EXHAUST HOODS AND FIRE | | SUPPRESSION SYSTEMS- SECTION 107.2.1 WPB. PLEASE PLACE | | A NOTE ON THE PLAN ACCORDINGLY. | | | | 2) ALTHOUGH THE PLAN INDICATES NO MECHANICAL WORK, | | THERE IS A REQUIREMENT TO VERIFY ADEQUATE VENTILATION | | IS BEING PROVIDED TO THE NEW SPACES. PLEASE REFER TO | | SECTION 809.2 FBC-17 EXISTING BUILDING CODE AND PROVIDE | | MINIMUM VENTILATION CALCULATIONS FOR ALL ROOMS AND | | SPACES PER TABLE 403.3.1.1 FBC-17 MECHANICAL. PROVIDE A | | SCHEDULE THAT INDICATES THE REQUIRED AND PROVIDED CFMS | | OF OUTDOOR AIR. | | | | 3) COOKING KITCHENS REQUIRE AN EXHAUST SYSTEM SIZED AT | | A RATE 0.7 CFMS PER SQUARE FT, AND RECIRCULATION OF AIR | | FROM THE KITCHEN TO OTHER ROOMS AND SPACES IS | | PROHIBITED- SEE TABLE 403.1.1 FBC M FOOTNOTE B. PLEASE | | CLARIFY IF ANY ELECTRIC OR GAS-FIRED COOKING | | APPLLIANCES ARE TO BE INSTALLED AND PROVIDE AN | | EQUIPMENT SCHEDULE AND PLAN IF APPLICABLE. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS. | | | | CHRISTOPHER L. COLE | | BUILDING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2019-07-11 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-07-11 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-07-11 |
Time |
08:51 |
Sent To |
|
|
Notes |
2019-07-11 14:46:04 | PROVISO PLANS REDLINED. | | | | 1) EACH BUILDING DRAIN REQUIRES 1 VENT THAT EXTENDS TO | | THE OUTDOORS. THE DIPPING WELL, HAND SINK, AND THE ICE | | CUBE DRAIN ALL SHOW AAV VENTS. PROVIDE 1 THAT VENTS TO | | THE OUTDOORS ON THIS BUILDING DRAIN. FBC P 904.1. THE | | ONLY VENT THAT EXTENDS IS ON THE INLET SIDE OFT HE | | GREASE INTERCEPTOR. | | | | 3) PROVIDE SHUT OFF VALVES AT THE TOP OF EVERY WATER | | DOWN FEED PIPE. FBC P 606.1 (5). ACCESS PANEL TO THESE | | VALVES SHALL BE PROVIDE. FBC P606.3 | | | | 4) PROVIDE BATHROOM ACCESSIBILITY DETAILS FOR THE GRAB | | BARS AND THE TOILET PAPER HOLDER. FBC-ACC 604.5.1, | | 604.5.2, 604.7, 603.3, 604.2, 604.6, 604.4, 606.3, | | 609.4 | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2019-07-08 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-07-08 |
Time |
12:07 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-07-08 |
Time |
09:09 |
Sent To |
|
|
Notes |
2019-07-08 12:07:02 | PLUMBING 3RD REVIEW**DENIED** | | | | 1) EACH BUILDING DRAIN REQUIRES 1 VENT THAT EXTENDS TO | | THE OUTDOORS. THE DIPPING WELL, HAND SINK, AND THE ICE | | CUBE DRAIN ALL SHOW AAV VENTS. PROVIDE 1 THAT VENTS TO | | THE OUTDOORS ON THIS BUILDING DRAIN. FBC P 904.1. THE | | ONLY VENT THAT EXTENDS IS ON THE INLET SIDE OFT HE | | GREASE INTERCEPTOR. | | | | 2) SHT. P1 PLUMBING ISOMETRIC THE TOILET IS MISSING | | FROM THE DRAWING. FBC 107.3.5 | | | | 3) PROVIDE SHUT OFF VALVES AT THE TOP OF EVERY WATER | | DOWN FEED PIPE. FBC P 606.1 (5). ACCESS PANEL TO THESE | | VALVES SHALL BE PROVIDE. FBC P606.3 | | | | 4) PROVIDE BATHROOM ACCESSIBILITY DETAILS FOR THE GRAB | | BARS AND THE TOILET PAPER HOLDER. FBC-ACC 604.5.1, | | 604.5.2, 604.7 | | | | | | TIM HUNT | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | CITY OF WEST PALM BEACH | | 561-248-2703 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2019-06-12 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-06-12 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-06-06 |
Time |
11:29 |
Sent To |
|
|
Notes |
2019-06-12 09:19:17 | | | 2ND REVIEW: | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | PLUMBING COMMENTS: | | | | 1. YOUR SIZING CALCULATION FOR YOUR GREASE INTERCEPTOR | | IS INACCURATE THIS FORMULA IS MEANT TO BE USED FOR | | LARGER SIT DOWN RESTAURANTS AND IT IS ONLY LISTING 1 | | SEAT AND THE PLAN SHOWS 4, YOU NEED TO USE THE | | CALCULATIONS THE USE THE VOLUME OF THE SINKS TO | | DETERMINE THE GPM ALSO KNOWN AS THE PDI METHOD. IN | | ORDER TO APPROVE THIS INTERCEPTOR YOU SHALL PROVIDE | | SIZING CALCULATIONS FROM THE MANUFACTURE THEY CAN BE | | EASILY FOUND ON THE MANUFACTURE,S WEB SITE. PER FBC PL | | 1003.2 AND WPB AMEND TO FBC 107.2.1 | | | | 2. YOU PROVIDED MANUFACTURE SPECIFICATIONS BUT YOU DID | | NOT LIST THE MODEL THAT YOU WILL BE USING PLEASE MARK | | THE MODEL ON THE SPECS AND PROVIDE MANUFACTURE | | INSTALLATION GUIDE. WPB AMEND TO FBC 107.2.1 | | | | 3. YOUR SANITARY ISOMETRIC IS NOTING STUDOR VENTS ON | | ALL OF THE VENT STACKS AT LEAST ONE OF THE VENTS SHALL | | DISCHARGE TO THE EXTERIOR OF THE BUILDING.PER FBC PL | | 904.1 | | | | 4. THE ICE MACHINE REQUIRES A AIR HAMMER ARRESTOR | | LOCATE AT THE APPLIANCE.PER FBC PL 604.9 | | | | 5. SHUT OFF VALVES ARE REQUIRED AT ALL DROPS ON THE HOT | | AND COLD WATER SYSTEM PLEASE SHOW ON ISOMETRIC . PER | | FBC PL 606.1(5) | | | | 6. PLEASE NOTE ON THE PLAN THE EXISTING FLOOR DRAIN | | SHALL HAVE A TRAP PRIMER.FBC PL 1002.4.1 | | | | 7. THE 3 COMP SINK AND THE PREP SINK SHALL BE INDIRECT | | WASTE PLEASE NOT ON PLAN. PER FBC PL 802.1.1 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-04-25 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-04-25 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-04-25 |
Time |
09:02 |
Sent To |
|
|
Notes |
2019-04-25 12:12:26 | 1ST REVIEW: | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | PLUMBING COMMENTS: | | | | 1. THE PREVIOUS OCCUPANCY OF THE THIS SPACE WAS A | | MERCANTILE WHICH WOULD MAKE THIS A CHANGE OF OCCUPANCY | | NOT LEVEL 2 ALTERATION. PER BUSINESS LICENSE RECORD OF | | PROPERTY. SHALL COMPLY WITH FBC EX 506.1 AND CH 10 | | | | 2. THE COVER SHEET STATES AS BUSINESS OCCUPANCY SHT A-1 | | UNDER LIFE SAFETY NOTES LIST IT AS MERCANTILE PLEASE | | CLARIFY. THIS IS AN ASSEMBLY THAT IS CLASSIFIED AS A | | BUSINESS PER FBC 303.1.1 SMALL BUILDINGS AND TENANT | | SPACES. A BUILDING OR TENANT SPACE USED FOR ASSEMBLY | | PURPOSES WITH AN OCCUPANT LOAD OF LESS THAN 50 PERSONS | | SHALL BE CLASSIFIED AS A GROUP B OCCUPANCY. | | | | 3. TWO BATHROOMS ARE REQUIRED PER FBC PL 403.2 SEPARATE | | FACILITIES. WHERE PLUMBING FIXTURES ARE REQUIRED, | | SEPARATE FACILITIES SHALL BE PROVIDED FOR EACH SEX. PER | | FBC EX 1010.1 | | | | 4. IS THE EXISTING BATHROOM FULLY ACCESSIBLE PER 2017 | | FBC ACC 6TH EDITION PLEASE SHOW LEVEL OF ACCESSIBILITY | | SUCH AS GRAB BARS TOILET AND LAVATORY AND CLEAR FLOOR | | SPACE FOR THE FIXTURES. PER WPB AMEND TO FBC 107.2.1. A | | MINIMUM OF 20% OF THE TOTAL COST OF THE JOB SHALL BE | | USED TO BRING UP THE LEVEL OF ACCESSIBILITY OF THE | | SPACE. PER FBC ACC 202.4, 202.4.1 | | | | 5.EVEN THOUGH THERE MAY NOT BE COCKING BEING DONE ANY | | TIME FOOD OR DRINKS ARE BEING MADE THAT COULD PRODUCE | | ANY TYPE OF GREASE SUCH AS DIARY , NUT BUTTERS A GREASE | | TRAP IS REQUIRED FOR ANY TYPE OF KITCHEN THERE ARE NO | | EXEMPTIONS. PER FBC PL 1003.1 AND WPB UTILITIES | | DEPARTMENT FOG PROGRAM | | | | 6. PLEASE PROVIDE A WATER ISOMETRIC DRAWING. PER FBC PL | | 107.3.5.1.3 | | | | 7. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES | | AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET | | FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND | | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN | | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT | | CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC 416.5 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] |
|
|
Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
Rev No |
2 |
Status |
P |
Date |
2019-07-08 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-07-08 |
Time |
12:07 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-07-08 |
Time |
12:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P-GREASE |
GREASE INTERCEPTOR/TRAP REVIEW |
Rev No |
1 |
Status |
F |
Date |
2019-06-12 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-06-12 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-06-12 |
Time |
09:20 |
Sent To |
|
|
Notes |
2019-06-12 09:22:35 | 2NDREVIEW: | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | PLUMBING COMMENTS: | | | | 1. YOUR SIZING CALCULATION FOR YOUR GREASE INTERCEPTOR | | IS INACCURATE THIS FORMULA IS MEANT TO BE USED FOR | | LARGER SIT DOWN RESTAURANTS AND IT IS ONLY LISTING 1 | | SEAT AND THE PLAN SHOWS 4, YOU NEED TO USE THE | | CALCULATIONS THE USE THE VOLUME OF THE SINKS TO | | DETERMINE THE GPM ALSO KNOWN AS THE PDI METHOD. IN | | ORDER TO APPROVE THIS INTERCEPTOR YOU SHALL PROVIDE | | SIZING CALCULATIONS FROM THE MANUFACTURE THEY CAN BE | | EASILY FOUND ON THE MANUFACTURE,S WEB SITE. PER FBC PL | | 1003.2 AND WPB AMEND TO FBC 107.2.1 | | | | 2. YOU PROVIDED MANUFACTURE SPECIFICATIONS BUT YOU DID | | NOT LIST THE MODEL THAT YOU WILL BE USING PLEASE MARK | | THE MODEL ON THE SPECS AND PROVIDE MANUFACTURE | | INSTALLATION GUIDE. WPB AMEND TO FBC 107.2.1 | | | | 3. PLEASE NOTE ON THE PLAN A SEPARATE PERMIT IS | | REQUIRED FOR THE GREASE INTERCEPTOR. PER WPB UTILITIES | | DEPT. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2019-07-15 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2019-07-15 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2019-07-15 |
Time |
|
Sent To |
|
|
Notes |
2019-07-15 11:31:02 | APPROVAL STAMPED ON 7/12/19 BY AAPONTE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2019-06-12 |
|
|
Cont ID |
|
Sent By |
aaponte |
Date |
2019-06-12 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
aaponte |
Date |
2019-06-12 |
Time |
14:43 |
Sent To |
|
|
Notes |
|
|
|