2019-05-01 17:34:54 | BUILDING PLAN REVIEW |
| 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| BUILDING PLANS EXAMINER, PX3169 |
| 1&2 FAMILY PLANS EXAMINER, SFP306 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| 1ST REVIEW |
| RESULTS: DENIED |
| YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| BELOW. |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| 1. VALUE HAS BEEN ADJUSTED FRO 120000 TO 173580 BASED |
| ON THE ICC BUILDING VALUATION DATA PUBLISHED FEB. 2019. |
| CITY OF WPB CHPT. 1 VALUE |
| 109.3 BUILDING PERMIT VALUATIONS. |
| FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE |
| BUILDING OFFICIAL. |
| |
| 2. PROVIDE SITE DRAINAGE PLAN. |
| FBC R401.3 SITE DRAINAGE |
| PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING |
| COMPLIANCE WITH FBC R401.3 |
| |
| 3. DESIGN PROFESSIONALS SIGNATURE AND SEAL ON SOILS |
| REPORT IS INVALID. |
| PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND |
| SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE, |
| DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE |
| 61G15-23.001. |
| |
| 4. PROVIDE SITE PLAN. |
| 107.2.5 SITE PLAN. |
| |
| 5. BUILDING ORIENTATION TO CARDINAL NORTH ON PLAN PAGE |
| A-1 IS INCORRECT. |
| FBC 107.2.1 & FBC ENERGY CONSERVATION R405.4.2.1 |
| |
| 6. PROVIDE PRODUCT SPECIFICATIONS AND INSTALLATION |
| INSTRUCTIONS FOR THE PROPOSED ICYNENE INSULATION. |
| 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| |
| 7. PROVIDE DETAIL FOR ALL WELDED CONNECTIONS. |
| 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| |
| 8. SHOW FINISHED FLOOR ELEVATION ON SITE PLAN/FLOOR |
| PLAN. |
| R403.1.7.3 FOUNDATION ELEVATION. |
| |
| 9. BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| APPLICATION. PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| 10. GUTTERS REQUIRED. |
| R318.5PROTECTION AGAINST DECAY AND TERMITES. |
| GUTTERS WITH DOWNSPOUTS ARE REQUIRED ON ALL BUILDINGS |
| WITH EAVES OF LESS THAN 6 INCHES (152 MM) HORIZONTAL |
| PROJECTION EXCEPT FOR GABLE END RAKES OR ON A ROOF |
| ABOVE ANOTHER ROOF |
| |
| 11. FBC 107.3.5.3 ? INDICATE THE MEANS OF TERMITE |
| PROTECTION PROPOSED PURSUANT TO FBC-R318. |
| |
| 12. INCREASE OPENING PRESSURE TO CORRESPOND WITH THE |
| 20FT. MRH PER FBC R301.2.1. |
| |
| 13. NOA 17-0130.04 ELASTATITE G 20140 IS FOR ROOF TILE. |
| REMOVE FROM SUBMITTAL. |
| |
| 14. IDENTIFY ROOFING SYSTEM COMPONENTS TO BE USED ON |
| PAGE 3 OF 4 OF THE TRINITY EVALUATION REPORT. |
| |
| 15. PROVIDE TYPICAL EXTERIOR DOOR FRAMING DETAIL. |
| 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| |
| 16. EXTERIOR CLADDING (STUCCO) SHALL TERMINATE 6 INCHES |
| ABOVE FINISHED GRADE. |
| R318.7 INSPECTION FOR TERMITES. |
| IN ORDER TO PROVIDE FOR INSPECTION FOR TERMITE |
| INFESTATION, CLEARANCE BETWEEN EXTERIOR WALL COVERINGS |
| AND FINAL EARTH GRADE ON THE EXTERIOR OF A BUILDING |
| SHALL NOT BE LESS THAN 6 INCHES (152 MM). |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY |
| REVIEWED SHEETS DETACHED. |
| |
| |
| THE FOLLOWING PROVISOS WILL BE PLACED ON THE PLANS FOR |
| FIELD VERIFICATION: |
| 1. WELDER CERTIFICATIONS. |
| 2. INSTALLATION INSTRUCTIONS FOR ICYNENE INSULATION. |
| |
| |