Plan Review Details - Permit 19040448
Plan Review Stops For Permit 19040448
Review Stop AIPP ART IN PUBLIC PLACES
Rev No 3 Status P Date 2020-08-24 Cont ID  
Sent By shill Date 2020-08-24 Time 14:49 Rev Time 0.00
Received By shill Date 2020-08-24 Time 14:49 Sent To  
Notes
***NONE***

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 2 Status F Date 2020-01-06 Cont ID  
Sent By jgomez Date 2020-01-06 Time 16:08 Rev Time 0.00
Received By jgomez Date 2020-01-06 Time 16:08 Sent To  
Notes
2020-01-06 16:08:37ART IN PUBLIC PLACES PROVISO:
 PLEASE CONTACT THE PERSON BELOW TO COORDINATE THIS
 REQUIREMENT AND TO PASS THIS REVIEW:
 MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR
 822-1515 E-MAIL: [email protected]
  

Review Stop AIPP ART IN PUBLIC PLACES
Rev No 1 Status F Date 2019-12-02 Cont ID  
Sent By jgomez Date 2019-12-02 Time 14:59 Rev Time 0.00
Received By jgomez Date 2019-12-02 Time 14:59 Sent To  
Notes
2019-12-02 15:00:13ART IN PUBLIC PLACES
 PLEASE CONTACT THE PERSON BELOW TO COORDINATE THIS
 REQUIREMENT AND TO PASS THIS REVIEW:
 MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR
 822-1515 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2020-01-06 Cont ID  
Sent By jgomez Date 2020-01-06 Time 17:12 Rev Time 0.00
Received By jgomez Date 2020-01-06 Time 17:11 Sent To  
Notes
2020-01-06 17:12:15BUILDING REVIEW APPROVED WITH PROVISO:
 1) REVISE BUILDING AREA SHOWN ON SHEET G-001 AND SHEET
 G-101 TO MATCH.
  
 2) AREA OF REFUGE: CLEARLY MARK THE DOOR PROVIDING
 ACCESS TO THE REFUGE AREA. SEE SEC 1007.6.5 2003
 INTERNATIONAL BUILDING CODE FOR SPECIFIC REQUIREMENTS.
 PROVIDE INFORMATION FOR REVIEW.,
  
 3) TYPE III-B CONSTRUCTION REQUIRES ALL EXTERIOR
 BEARING WALLS TO BE 2 HOUR FIRE RATED. VERIFY IN FIELD
 2 HOUR CONCRETE BLOCK FOR ALL 2 HOUR FIRE RATED WALLS
 SHOWN ON PLANS.
  
 4) PROVIDE ROOFING PRODUCT APPROVAL AND CLEARLY MARK
 ASSEMBLY TO BE INSTALLED.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 5)THE SUBMITTAL NOA: 16-0219.01 TC-5 SERIES STEEL ROOF
 CURB FOR TRANE ROOF TOP UNITS.
 PLEASE REVISE ROOFTOP MECHANICAL UNIT CURB AND
 ATTACHMENT RESPONSE LETTER. THE SECOND PARAGRAPH OF THE
 LETTER STATS THAT 2 BRACKETS ARE REQUIRED PER SIDE FOR
 A TOTAL OF 4 BRACKETS EACH UNIT. IF TWO BRACKETS ARE
 REQUIRED PER SIDE, THEN THE TOTAL IS 8 BRACKETS PER
 UNIT NOT 4.
  
 6) THE SUBMITTAL NOA: 17-1017.14 TRULITE SERIES 3100
 REGISTER ALUMINUM STOREFRONT/ WINDOW WALL SYSTEM- L. M.
 I.
 NEED TO PROVIDE THE NOA FOR TRULITE DOORS AS SPECIFIED
 ON THE STOREFRONT NOA.
  
 7- SEPARATE PERMIT IS REQUIRED FOR THE DIESEL TANK
 SHOWN ON PLANS.
  
  
 ART IN PUBLIC PLACES PROVISO:
 PLEASE CONTACT THE PERSON BELOW TO COORDINATE THIS
 REQUIREMENT AND TO PASS THIS REVIEW:
 MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR
 822-1515 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2019-12-02 Cont ID  
Sent By jgomez Date 2019-12-02 Time 14:04 Rev Time 0.00
Received By jgomez Date 2019-11-27 Time 10:05 Sent To  
Notes
2019-11-27 14:33:15BUILDING REVIEW APPROVED WITH PROVISO:
 1) REVISE BUILDING AREA SHOWN ON SHEET G-001 AND SHEET
 G-101 TO MATCH.
  
 2) AREA OF REFUGE: CLEARLY MARK THE DOOR PROVIDING
 ACCESS TO THE REFUGE AREA. SEE SEC 1007.6.5 2003
 INTERNATIONAL BUILDING CODE FOR SPECIFIC REQUIREMENTS.
 PROVIDE INFORMATION FOR REVIEW.,
  
 3) TYPE III-B CONSTRUCTION REQUIRES ALL EXTERIOR
 BEARING WALLS TO BE 2 HOUR FIRE RATED. VERIFY IN FIELD
 2 HOUR CONCRETE BLOCK FOR ALL 2 HOUR FIRE RATED WALLS.
 SOWN ON PLANS.
  
 4) PROVIDE ROOFING PRODUCT APPROVAL AND CLEARLY MARK
 ASSEMBLY TO BE INSTALLED.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 5)THE SUBMITTAL NOA: 16-0219.01 TC-5 SERIES STEEL ROOF
 CURB FOR TRANE ROOF TOP UNITS.
 PLEASE REVISE ROOFTOP MECHANICAL UNIT CURB AND
 ATTACHMENT RESPONSE LETTER. THE SECOND PARAGRAPH OF THE
 LETTER STATS THAT 2 BRACKETS ARE REQUIRED PER SIDE FOR
 A TOTAL OF 4 BRACKETS EACH UNIT. IF TWO BRACKETS ARE
 REQUIRED PER SIDE, THEN THE TOTAL IS 8 BRACKETS PER
 UNIT NOT 4.
  
 6) THE SUBMITTAL NOA: 17-1017.14 TRULITE SERIES 3100
 REGISTER ALUMINUM STOREFRONT/ WINDOW WALL SYSTEM- L. M.
 I.
 NEED TO PROVIDE THE NOA FOR TRULITE DOORS AS SPECIFIED
 ON THE STOREFRONT NOA.
  
 7- SEPARATE PERMIT IS REQUIRED FOR THE DIESEL TANK
 SHOWN ON PLANS.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2019-11-08 Cont ID  
Sent By jgomez Date 2019-11-08 Time 16:54 Rev Time 0.00
Received By jgomez Date 2019-11-08 Time 09:27 Sent To  
Notes
2019-11-08 16:55:11NEW AUTOMOBILE DEALERSHIP, THIRD BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
  
 NOTICE: *************** 4X FEE / NOTICE!!!!!
 ARCHITECTS-ENGINEERS
 FLORIDA STATUTE 553.80(2)(B) ******************
 WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS?
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
  
  
 1) SHEET 002-G-101 THE LIFE SAFETY PLAN:
  
 ORIGINAL COMMENT:
 1A) 3RD REQUEST. UNDER THE HEADING BUILDING CODE
 SUMMARY THE PROPOSED USE IS LISTED AS BUSINESS (B) AND
 STORAGE (S1). PLEASE NOTE THAT THE SERVICE SHOP IS
 LISTED AS A S1 OCCUPANCY. FOR MOTOR VEHICLE REPAIR
 GARAGES COMPLYING WITH THE MAXIMUM ALLOWABLE QUANTITIES
 OF HAZARDOUS MATERIALS LISTED IN TABLE 307.1(1).
 PLEASE SUBMIT A LIST OF HAZARDOUS MATERIALS AND
 ALLOWABLE QUANTITIES PER THE 2017 FBC-B TABLE 307.1(1).
  
 RESPONSE:
 THE SAME RESPONSE THAT WAS PROVIDED ON THE PREVIOUS
 COMMENT WAS PROVIDED THIS TIME AGAIN. THE ONLY
 DIFFERENCE IS THAT THE NOTE "G-101 NOTE ADDED (CLOUD
 3)" WAS ADDED.
 THIS DOESN'T ANSWER THE REQUEST FROM THE PREVIOUS
 REVIEWER. THE REQUEST IS TO PROVIDE THE LIST AND
 QUANTITIES OF EACH HAZARDOUS MATERIALS THAT ARE GOING
 TO BE STORED IN THIS PLACE. ALSO, CLEARLY SHOW ON PLANS
 LOCATION OF EACH MATERIAL. ARCHITECT MAY WANT TO
 COORDINATE THIS INFORMATION WITH THE OWNER OF THE
 DEALERSHIP TO VERIFY QUANTITIES OF EACH MATERIAL TO BE
 STORED IN THIS PLACE AND PROVIDE INFORMATION ON
 DRAWINGS.
  
  
 1B) OK
  
 ORIGINAL COMMENT:
 1C) SEMI-COMPLIED. UNDER THE BUILDING DATA THERE IS NO
 LISTING FOR THE REQUIRED AREA OF REFUGE, THIS IS A 2
 STORY BUILDING AND NO FIRE SPRINKLERS. THE 2017
 FBC-ACCESSIBILITY CODE UNDER SECTION 207 ACCESSIBLE
 MEANS OF EGRESS. SECTION 207.1. MEANS OF EGRESS SHALL
 COMPLY WITH SECTION 1007 OF THE INTERNATIONAL BUILDING
 CODE (2003 EDITION).
 PLEASE REVIEW IN THE 2003 IBC-B SECTIONS DEALING WITH:
  
 1007.3 ENCLOSED EXIT STAIRWAYS, 48 INCHES BETWEEN
 HANDRAILS.
 RESPONSE:
 OK. DIMENSIONS ON PLANS WERE REVISED, BUT INFORMATION
 ON SHEET G101 WAS NOT REVISED. REVISE AS REQUIRED TO
 MATCH.
  
 1007.4 ELEVATORS.
 RESPONSE:
 OK. NO USED AS MEANS OF EGRESS.
  
 1007.6 AREAS OF REFUGE.
 RESPONSE:
 OK. BUT, CLEARLY IDENTITY ON PLANS "AREA OF REFUGE AND
 SPECIFY SIZE.
  
 1007.6.1. SIZE.
 RESPONSE:
 CLEARLY IDENTITY ON PLANS "AREA OF REFUGE AND SPECIFY
 SIZE.
  
 1007.6.2. SEPARATION.
 RESPONSE:
 OK. NO REQUIRED.
  
 1007.6.3. TWO-WAY COMMUNICATION.
 RESPONSE:
 OK. BUT NEED TO CLEARLY SPECIFY IT ON PLANS. AND, TWO
 WAY COMMUNICATIONS SHALL INCLUDE BOTH AUDIBLE AND
 VISIBLE SIGNALS.
  
 1007.6.4. INSTRUCTIONS.
 RESPONSE:
 CLEARLY SPECIFY ON PLANS REQUIRED INSTRUCTIONS.
  
 1007.6.5. IDENTIFICATION.
 RESPONSE:
 CLEARLY PROVIDE ON PLANS THE IDENTIFICATION
 INFORMATION.
  
 1007.7.7. SIGNAGE.
 RESPONSE:
 CLEARLY SPECIFY ON PLANS SIGNAGE THAT ELEVATOR IS NOT
 AN APPROVED ACCESSIBLE MEANS OF EGRESS AND INDICATE
 LOCATION OF ACCESSIBLE MEANS OF EGRESS.
  
  
 ORIGINAL COMMENT:
 1D) 3RD REQUEST. SEPARATED MIXED OCCUPANCY SHOWS THE
 FORMULA FOR AREA CALCULATIONS BUT HAS LEFT THE
 CALCULATION BLANK. PLEASE PROVIDE THE ACTUAL AND
 ALLOWABLE SQUARE FEET FOR EACH OF THE OCCUPANCIES AND
 THE END CALCULATION. 2017 FBC-B 508.3.3.
  
 RESPONSE:
 OCCUPANCIES LISTED ON SHEET G-101 (A AND M OCCUPANCIES)
 DON'T CORRESPOND TO THE OCCUPANCIES LISTED UNDER
 "ALLOWABLE AREA" (B AND S-1 OCCUPANCIES). REVISE AS
 REQUIRED.
  
  
 ORIGINAL COMMENT:
 1E) SEMI-COMPLIED. PLEASE NOTE THE PLANS DOES NOT STATE
 THE ACTUAL OCCUPANT LOAD FOR EACH OF THE OCCUPANCIES.
 THE EXIT WIDTH DOES PROVIDE THE AREA FOR EACH OCCUPANCY
 AND AREA PER OCCUPANT (TABLE 1004.1.2) BUT DOES NOT
 GIVE THE ACTUAL OCCUPANT LOAD PER STORY AND THE TOTAL
 OCCUPANT LOAD. 2017 FBC-B 1004.1 & TABLE 1004.1.2.
  
 RESPONSE:
 INFORMATION SHOWN ON THE "EGRESS WIDTH" TABLE AND
 INFORMATION SHOWN ON PLANS DON'T MATCH. PROVIDE THE
 NUMBER OF PEOPLE FOR EACH OCCUPANCY BASED ON THE GROSS
 SQUARE FOOTAGE AS REQUIRED BY TABLE 1004.1.2
 FBC-BUILDING. AND, COORDINATE WITH NUMBER OF PEOPLE
 SHOWN ON FLOOR PLANS FOR EACH OCCUPANCY. CLARIFY WHY ON
 THE SECOND FLOOR THERE ARE MORE CHAIRS THAN NUMBER OF
 PEOPLE SPECIFIED?. SEC. 107.2.1 CITY AMENDMENTS.
  
 ALSO, REVISE INFORMATION ON THE EXIT WIDTH TABLE.
 REVISE SIZE OF STAIRS TO MATCH PLANS REVISED TO COMPLY
 WITH THE ACCESSIBILITY REQUIREMENTS. AND, REVISE THE
 "EGRESS CAPACITY FACTOR" OF THE STAIRS TO COMPLY WITH
 SEC. 1005.3.1 FBC-BUILDING. THE FACTOR IS 0.3 NOT 0.2.
  
 IN ADDITION, REVISE THE ACTUAL WIDTH OF OPENINGS FOR
 "OTHER EGRESS COMPONENTS" ( EGRESS DOORS FOR EXAMPLE).
 SEE SEC. 1010.1.1 FBC-BUILDING FOR ACTUAL SIZE OF
 EGRESS DOORS AND REVISE INFORMATION ON PLANS AS
 REQUIRED.
  
  
 ORIGINAL COMMENT:
 1F)KEY NOTES ON SHEET 041-A-101 INDICATE THE DESIGNER
 OF RECORD REQUIRING A 2 HOUR WALL BETWEEN THE B & S1
 OCCUPANCY AND DECLARING THE BLOCK TO COMPLY WITH
 (U905). THIS DESIGN REQUIRES A D-2 A 8 INCH BLOCK, AND
 2 HOUR FIRE RATED CONCRETE BLOCK. PLEASE NOTE WE WILL
 REQUIRE DOCUMENTATION FROM THE BLOCK MANUFACTURER THAT
 THEIR 2 HOUR RATING OF BLOCK COMPLIES WITH TABLE
 722.3.2. (2017 FBC-B) MINIMUM EQUIVALENT THICKNESS OF
 BEARING OR NONBEARING CONCRETE MASONRY WALLS. PROVIDE
 THE TYPE OF AGGREGATE AND EQUIVALENT THICKNESS FOR THE
 2 HOUR FIRE RATING. THE SAME FOR 12 INCH WIDE BLOCK,
 PROVIDE A LETTER FROM THE BLOCK MANUFACTURER.
  
 RESPONSE:
 WALL TYPES AND PLANS ARE NOT CLEAR. MISSING DETAILS FOR
 THE SPECIFIED FIRE RATED WALLS. PROVIDE COMPLETE WALL
 DETAIL FOR THE 2 HOUR FIRE RATED CONCRETE BLOCK WALLS
 (U905) SPECIFYING 2HR BLOCK. ALSO, PROVIDE COMPLETE
 WALL DETAIL FOR THE ONE HOUR FIRE RATED PARTITION
 (U419). AND, CLEARLY TAG THEM ON THE FLOOR PLANS. IN
 ADDITION, CLEARLY SPECIFY IF IT'S 8" OR 12" CONCRETE
 BLOCK. SEC. 107.2.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 1G) 3RD REQUEST. SHEET A-501 WALL TYPES A3-A6 ALL SHOW
 BLOCK WALLS WITH EITHER 8 INCH OR 12 INCH CMU. EACH
 DETAIL SHOULD BE SPECIFIC TO BLOCK TYPE AND WALL TYPE.
 AGAIN THESE DETAILS DO NOT MATCH THE WALL
 IDENTIFICATION TAGS LOCATED IN SHEETS 041-A-101 AND
 042-A-102. INFORMATION ON THE PLANS HAS TO BE SPECIFIC
 NO EITHER, OR. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 RESPONSE:
 SEE RESPONSE FOR ITEM 1(F) ABOVE.
  
 1H) OK.
  
  
  
 ORIGINAL COMMENT:
 SECOND ROUND OF COMMENTS. THE LIFE SAFETY SHEET
 002-G-101 SHOWS A SECOND STORY BUSINESS AND STORAGE
 OCCUPANCY, (ASSUMED S-1). THE TRAVEL DISTANCE IS SHOWN
 GOING DOWN THROUGH THE STAIRWAY MAKING THIS STAIRWAY
 EXIT ACCESS AND THE TRAVEL DISTANCE ON THE STAIRS TO BE
 TAKEN PARALLEL TO THE STAIRS. FROM THE FURTHEST POINT
 TAKEN ON THE SECOND FLOOR TO THE FIRST FLOOR LANDING
 THE TRAVEL DISTANCE IS BETWEEN 85 TO 90 FEET. THIS IS
 OVER THE ALLOWABLE MAXIMUM COMMON PATH OF TRAVEL FROM
 TABLE 1006.3.2(2) OF 75 FEET AND OCCUPANT LOAD OF 49
 FOR BUSINESS OR 29 FOR STORAGE OCCUPANCY. IF THE
 STAIRWAY WAS A RATED 1 HOUR EXIT STAIRWAY WITH OPENING
 PROTECTIVES AND EXIT PASSAGEWAY TO THE EXTERIOR, THEN
 THE TRAVEL DISTANCE FOR THE 2ND FLOOR WOULD WORK.
 PLEASE REVIEW ALL OF THE REQUIREMENTS FOR EXIT AND EXIT
 PASSAGEWAYS. EXIT PASSAGEWAYS ARE FOUND UNDER FBC-B
 1024. PLEASE REVIEW VENTILATION REQUIREMENTS (FBC-B
 1024.7) FOR EXIT PASSAGEWAYS AS WELL.
  
 RESPONSE:
 THIS IS A TWO STORY BUILDING. TABLE 1006.3.2(2)
 FBC-BUILDING IS THE TABLE THAT APPLIES TO THIS
 BUILDING. IF THERE IS A DIFFERENCE BETWEEN THE FIRE
 CODE AND BUILDING CODE THEN THE MOST STRINGENT CODE
 PREVAILS. IT LOOKS LIKE THE STAIRWAY IS GOING TO BE AT
 LEAST ONE HOUR FIRE RATED. REVISE TRAVEL DISTANCE. SHOW
 TRAVEL DISTANCE UP TO THE ENTRY OF THE STAIRWAY.
  
  
 ORIGINAL COMMENT:
 1J) 3RD REQUEST. VERSION # 2 STILL DOES NOT SHOW
 COMPLIANCE WITH FBC-B 1015.4 OPENING LIMITATIONS.
 REQUIRED GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW
 PASSAGE OF A SPHERE 4 INCHES (102 MM) IN DIAMETER FROM
 THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT. ALSO
 THERE IS A DETAIL FOR RISE AND RUN BUT NO DIMENSION FOR
 COMPLIANCE WITH 1015.4 FBC-B EXCEPTION 2. THE
 TRIANGULAR OPENINGS AT THE OPEN SIDES OF A STAIR,
 FORMED BY THE RISER, TREAD AND BOTTOM RAIL SHALL NOT
 ALLOW PASSAGE OF A SPHERE 6 INCHES IN DIAMETER.
 1 ST ROUND OF COMMENTS. STAIRWAY GUARDRAIL. SHEET
 049-A-101. PLEASE PROVIDE A DETAIL SHOWING COMPLIANCE
 WITH: 2017 FBC-B 1015.4 OPENING LIMITATIONS. REQUIRED
 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW PASSAGE OF A
 SPHERE 4 INCHES (102 MM) IN DIAMETER FROM THE WALKING
 SURFACE TO THE REQUIRED GUARD HEIGHT.
  
 RESPONSE:
 STAIR SECTION A4 ON SHEET 049-A-401 SPECIFIES 4"
 BETWEEN THE HORIZONTAL RAILING. THE DIMENSION NEEDS TO
 BE SMALLER THAN 4 INCHES SO IT DOESN'T ALLOW THE
 PASSAGE OF 4" SPHERE. REVISE AS REQUIRED.
 ALSO, THE REQUESTED INFORMATION FOR THE LIMITATIONS ON
 THE TRIANGULAR AREA AT THE OPEN SIDE OF THE STAIRS WAS
 NOT PROVIDED. PROVIDE COMPLETE INFORMATION.
  
  
 ORIGINAL COMMENT:
 2A) 3RD REQUEST. THERE MUST BE A PERMANENT MEANS OF
 EGRESS TO REACH THE ROOF TOP HATCH.
 1ST ROUND OF COMMENTS. SHEET 042-A102 THE 2ND FLOOR
 PLAN AND ROOF PLAN OF THE REPAIR GARAGE, SHOWS A ROOF
 HATCH TO GAIN ACCESS TO THE MECHANICAL EQUIPMENT ON THE
 ROOF. SHEET 047-A-301 SHOWS A VERTICAL DISTANCE FROM
 THE FINISH FLOOR TO THE BOTTOM OF THE BAR JOIST OF
 14.66 FEET, CENTERED IN THE SERVICE BAY DOORWAY. THE
 VERTICAL DISTANCE FROM FINISH FLOOR TO THE TOP OF THE
 ROOF AT THE ROOF HATCH IS OVER 18.50 FEET. PLEASE SHOW
 HOW COMPLIANCE WITH 306.5 OF THE 2017 MECHANICAL CODE
 WILL BE MET:
 2017 FBC-MECHANICAL. 306.5 EQUIPMENT AND APPLIANCES ON
 ROOFS OR ELEVATED STRUCTURES.
 WHERE EQUIPMENT REQUIRING ACCESS OR APPLIANCES ARE
 LOCATED ON AN ELEVATED STRUCTURE OR THE ROOF OF A
 BUILDING SUCH THAT PERSONNEL WILL HAVE TO CLIMB HIGHER
 THAN 16 FEET (4877 MM) ABOVE GRADE TO ACCESS SUCH
 EQUIPMENT OR APPLIANCES, AN INTERIOR OR EXTERIOR MEANS
 OF ACCESS SHALL BE PROVIDED. SUCH ACCESS SHALL NOT
 REQUIRE CLIMBING OVER OBSTRUCTIONS GREATER THAN 30
 INCHES (762 MM) IN HEIGHT.
  
 RESPONSE:
 UNABLE TO FIND DETAIL A6/A-503 FOR ROOF LADDER. PROVIDE
 INFORMATION SHOWING COMPLIANCE.
  
 2B) OK.
 2C) OK.
 3) OK.
 4) OK.
 5) OK
  
 ORIGINAL COMMENT:
 6) 3RD REQUEST. THE SUBMITTED NOA: 14-0827.18TAMKO
 MODIFIED BITUMEN ROOF SYSTEM OVER STEEL DECK HAS
 VARIOUS SUB-SYSTEMS LISTED WITHIN THE REPORT BUT NONE
 OF THE SUB-SYSTEMS WERE IDENTIFIED AS THE ONE BEING
 INSTALLED. : FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY
 ALL ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES
 FOR ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL
 LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED
 (LIMITATION #7 ALLOWS ENHANCED FASTENING, LIMITATION #
 9 DOES NOT ALLOW ENHANCED FASTENING) FOR ROOF ZONES 2 &
 3. FASTENER DENSITIES SHALL BE INCREASED FOR BOTH
 INSULATION & THE BASE SHEET AS CALCULATED IN COMPLIANCE
 WITH ROOFING APPLICATION STANDARDS RAS 117. CALCULATION
 PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED
 PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT.
 1609.6.4.4.1 COMPONENTS & CLADDING.
  
 RESPONSE:
 APPROVED ASSEMBLY WAS NOT SELECTED. AND, NEED SIGNED
 AND SEALED RAS 117 CALCULATIONS FOR SELECTED ASSEMBLY
 (GENERAL LIMITATION #7 ONLY). IF THE SELECTED ASSEMBLY
 IS LIMITED BY GENERAL LIMITATION #9 AND THE ASSEMBLY
 DOESN'T MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES,
 THEN IT CAN NOT BE USED.
 NOTE: ALL PRODUCT APPROVALS CAN BE SUBMITTED LATER AS
 DEFERRED SUBMITTAL. ADVICE IF PREFER TO SUBMIT PRODUCT
 APPROVALS AS DEFERRED SUBMITTAL.
  
 ORIGINAL COMMENT:
 7) 3RD REQUEST. THE SUBMITTAL NOA: 16-0219.01 TC-5
 SERIES STEEL ROOF CURB FOR TRANE ROOF TOP UNITS. PLEASE
 REVIEW SHEET 4 AND 5 OF THE PRODUCT APPROVAL FOR
 TECHNICAL NOTES. RESTRAINT BRACKET QUANTITY IS
 DETERMINED BY PROJECT SPECIFIC CALCULATIONS, PERFORMED
 BY A FLORIDA LICENSED PE OR FLORIDA REGISTERED
 ARCHITECT THAT CONSIDER THE UNIQUE COMBINATION OF THE
 UNIT SIZE AND APPLICABLE LATERAL AND UPLIFT PRESSURES
 FOR EACH JOB. PLEASE PROVIDE CALCULATION FOR HOW MANY
 BRACKETS WILL BE NEEDED FOR EACH TYPE OF UNIT.
 107.2.1.3. ADDITIONAL INFORMATION IS REQUIRED. 2017
 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL EQUIPMENT,
 APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO WIND SHALL
 BE DESIGNED AND INSTALLED TO RESIST THE WIND PRESSURES
 DETERMINED IN ACCORDANCE WITH THE FLORIDA BUILDING
 CODE, BUILDING.
  
 RESPONSE:
 PLEASE CLARIFY ROOFTOP MECHANICAL UNIT CURB AND
 ATTACHMENT RESPONSE LETTER. THE SECOND PARAGRAPH OF THE
 LETTER STATS THAT 2 BRACKETS ARE REQUIRED PER SIDE FOR
 A TOTAL OF 4 BRACKETS EACH UNIT. IF TWO BRACKETS ARE
 REQUIRED PER SIDE, THEN THE TOTAL IS 8 BRACKETS PER
 UNIT NOT 4. CLARIFY/REVISE AS REQUIRED. SEC. 107.2.1
 CITY AMENDMENTS.
  
  
 ORIGINAL COMMENT:
 8) 3RD REQUEST. THE SUBMITTAL NOA: 17-1017.14 TRULITE
 SERIES 3100 REGISTER ALUMINUM STOREFRONT/ WINDOW WALL
 SYSTEM- L. M. I. SHEETS 2-5 DO NOT OPEN FOR REVIEW.
 PLEASE NOTE ON PAGE 6 ONLY THE BOTTOM SERIES OF GLASS
 IS HIGHLIGHTED FOR PRESSURES. THE UPPER WINDOW GLASS IS
 NOT MENTIONED. THE UPPER GLAZING UNITS WHICH HAVE BOTH
 VERTICAL AND HORIZONTAL FRAMING MEMBERS ARE NOT
 IDENTIFIED ON SHEETS 8 AND 9 OF THE REPORT NOR IS THE
 CHART HIGHLIGHTED OR CIRCLED TO IF THE JAMBS ARE
 REQUIRED TO BE STEEL RE-ENFORCED. SHEET 10 OF 17 THE
 DOOR MULLION INDICATES TRULITE DOORS ARE UNDER A
 SEPARATE NOA. SHEET 13 OF 17 THE ANCHOR LOAD CHART IS
 NOT IDENTIFIED AS TO THE TYPE OF ANCHOR FOR THE FRAME
 WIDTH AND HEIGHT.
 IDENTIFY GLAZING/ MULLIONS.
 PLEASE IDENTIFY ON THE PRODUCT APPROVAL BEFORE
 SUBMITTING TO DESIGNER OF RECORD AND BEFORE SUBMISSION
 TO THE BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH
 GLAZING, PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT,
 TYPE OF GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED
 OR REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND
 ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2017 FBC-B
 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE
 INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER?S
 INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE
 PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED
 BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS.
  
 RESPONSE:
 NEED TO PROVIDE THE NOA FOR TRULITE DOORS AS SPECIFIED
 ON THE STOREFRONT NOA AND AS SHOWN ON PLANS.
  
 9) OK.
 10) OK
 11) OK
 12) OK
  
 13) INFORMATIONAL: ART IN PUBLIC PLACES
 FOR CONTACT INFORMATION PLEASE CONTACT:
 MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR
 822-1515 E-MAIL: [email protected]
  
 14) IMPACT FEES - SEE IMPACT FEES REVIEW STOP FOR
 PROCEDURE.
  
 15) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 IN ORDER TO AVOID MULTIPLE SUBMITTALS, PLEASE FEEL FREE
 TO CONTACT ME IF YOU HAVE ANY QUESTIONS REGARDING THESE
 COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2019-08-12 Cont ID  
Sent By jwitmer Date 2019-08-12 Time 11:49 Rev Time 0.00
Received By jwitmer Date 2019-08-12 Time 07:53 Sent To  
Notes
2019-08-12 11:49:532017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19040448
 ADD: 2700 S AUSTRALIAN AVE.
 CONT: AUTOBUILDERS GENERAL CONT. SVCS. INC.
 TEL: 561-622-3515
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
 2ND REVIEW
 DATE: MONDAY, AUGUST 12TH/2019
 ACTION: DENIED
  
 NOTICE: *************** 4X FEE / NOTICE!!!!! FLORIDA
 STATUTE 553.80(2)(B) ******************
 WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS?
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
  
 1) SHEET 002-G-101 THE LIFE SAFETY PLAN:
 1A).2ND REQUEST. UNDER THE HEADING BUILDING CODE
 SUMMARY THE PROPOSED USE IS LISTED AS BUSINESS (B) AND
 STORAGE (S1). PLEASE NOTE THAT THE SERVICE SHOP IS
 LISTED AS A S1 OCCUPANCY. FOR MOTOR VEHICLE REPAIR
 GARAGES COMPLYING WITH THE MAXIMUM ALLOWABLE QUANTITIES
 OF HAZARDOUS MATERIALS LISTED IN TABLE 307.1(1).
 PLEASE SUBMIT A LIST OF HAZARDOUS MATERIALS AND
 ALLOWABLE QUANTITIES PER THE 2017 FBC-B TABLE 307.1(1).
  
 1B) 2N REQUEST. UNDER THE HEADING OF BUILDING DATA THE
 PLANS ARE INDICATED THEY ARE DESIGNED UNDER THE 2014
 FBC. PLEASE NOTE THAT THE 2017 FBC-B WAS ADOPTED
 STATEWIDE ON DEC. 31/ 2017. PLEASE UPDATE PLANS.
  
 1C) 2ND REQUEST. UNDER THE BUILDING DATA THERE IS NO
 LISTING FOR THE REQUIRED AREA OF REFUGE, THIS IS A 2
 STORY BUILDING AND NO FIRE SPRINKLERS. THE 2017
 FBC-ACCESSIBILITY CODE UNDER SECTION 207 ACCESSIBLE
 MEANS OF EGRESS. SECTION 207.1. MEANS OF EGRESS SHALL
 COMPLY WITH SECTION 1007 OF THE INTERNATIONAL BUILDING
 CODE (2003 EDITION).
 PLEASE REVIEW IN THE 2003 IBC-B SECTIONS DEALING WITH:
 1007.3 ENCLOSED EXIT STAIRWAYS, 48 INCHES BETWEEN
 HANDRAILS.
 1007.4 ELEVATORS.
 1007.6 AREAS OF REFUGE.
 1007.6.1. SIZE.
 1007.6.2. SEPARATION.
 1007.6.3. TWO-WAY COMMUNICATION.
 1007.6.4. INSTRUCTIONS.
 1007.6.5. IDENTIFICATION.
 1007.7.7. SIGNAGE.
  
 1D) 2ND REQUEST. SEPARATED MIXED OCCUPANCY SHOWS THE
 FORMULA FOR AREA CALCULATIONS BUT HAS LEFT THE
 CALCULATION BLANK. PLEASE PROVIDE THE ACTUAL AND
 ALLOWABLE SQUARE FEET FOR EACH OF THE OCCUPANCIES AND
 THE END CALCULATION. 2017 FBC-B 508.3.3.
  
 1E) COMPLIED. PLEASE NOTE THE PLANS DOES NOT STATE THE
 ACTUAL OCCUPANT LOAD FOR EACH OF THE OCCUPANCIES. THE
 EXIT WIDTH DOES PROVIDE THE AREA FOR EACH OCCUPANCY AND
 AREA PER OCCUPANT (TABLE 1004.1.2) BUT DOES NOT GIVE
 THE ACTUAL OCCUPANT LOAD PER STORY AND THE TOTAL
 OCCUPANT LOAD. 2017 FBC-B 1004.1 & TABLE 1004.1.2.
  
 1F)SEMI-COMPLIED. KEY NOTES ON SHEET 041-A-101 INDICATE
 THE DESIGNER OF RECORD REQUIRING A 2 HOUR WALL BETWEEN
 THE B & S1 OCCUPANCY AND DECLARING THE BLOCK TO COMPLY
 WITH (U905). THIS DESIGN REQUIRES A D-2 A 8 INCH BLOCK,
 AND 2 HOUR FIRE RATED CONCRETE BLOCK. PLEASE NOTE WE
 WILL REQUIRE DOCUMENTATION FROM THE BLOCK MANUFACTURER
 THAT THEIR 2 HOUR RATING OF BLOCK COMPLIES WITH TABLE
 722.3.2. (2017 FBC-B) MINIMUM EQUIVALENT THICKNESS OF
 BEARING OR NONBEARING CONCRETE MASONRY WALLS. PROVIDE
 THE TYPE OF AGGREGATE AND EQUIVALENT THICKNESS FOR THE
 2 HOUR FIRE RATING. THE SAME FOR 12 INCH WIDE BLOCK,
 PROVIDE A LETTER FROM THE BLOCK MANUFACTURER.
 THE OTHER ISSUE WITH NOTES 10 AND 11 GO BACK TO THE
 WORD OR, 8 INCH OR 12 INCH BLOCK. THE REQUIREMENT HAS
 TO BE SPECIFIC. 2017 WEST PALM BEACH AMENDMENTS TO THE
 FLORIDA BUILDING CODE, CHAPTER 1 ADMINISTRATIVE CODE
 SECTION 107.2.1.3. DRAWINGS & SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC TO THE TECHNICAL CODES
 "SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR THE TERM
 "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR
 SPECIFIC INFORMATION". CONSTRUCTION DOCUMENTS SHALL BE
 SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND
 EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT
 WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
 1ST ROUND COMMENT. THE LIFE SAFETY SHEET 002-G-101
 UNDER THE HEADING OF ALLOWABLE AREA, MIXED OCCUPANCY
 INDICATES YES, AND SEPARATION 2 HRS. THE FIRST FLOOR
 PARTS ROOM HAS A NOTE 2 HRS. IT WOULD APPEAR THAT THIS
 NOTE REFERS TO THE BLOCK WALL BETWEEN THE BUSINESS
 OCCUPANCY AND S1 REPAIR GARAGE. THE FIRST FLOOR PLAN
 SHEET 041-A-101 HAS THIS SAME WALL WITH A WALL
 IDENTIFICATION TAG IDENTIFIED AS WALL TYPE 10. SHEET
 042-A-102 THE SECOND FLOOR HAS THE SAME WALL TYPE
 IDENTIFIED WITH A WALL IDENTIFICATION TAG AS WALL TYPE
 6. WHEN YOU OPEN UP SHEET 050-A-501 WALL TYPES NONE OF
 THE WALL TYPES SHOWN HAVE THE SAME NAMING CONVENTION.
  
 1G) 2ND REQUEST. SHEET A-501 WALL TYPES A3-A6 ALL SHOW
 BLOCK WALLS WITH EITHER 8 INCH OR 12 INCH CMU. EACH
 DETAIL SHOULD BE SPECIFIC TO BLOCK TYPE AND WALL TYPE.
 AGAIN THESE DETAILS DO NOT MATCH THE WALL
 IDENTIFICATION TAGS LOCATED IN SHEETS 041-A-101 AND
 042-A-102. INFORMATION ON THE PLANS HAS TO BE SPECIFIC
 NO EITHER, OR. SUCH DRAWINGS AND SPECIFICATIONS SHALL
 CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE,
 AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS
 ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH
 INFORMATION SHALL BE SPECIFIC. 107.2.1 INFORMATION ON
 CONSTRUCTION DOCUMENTS.
  
 1H) INFORMATIONAL ONLY. PLEASE NOTE THE DESIGNER OF
 RECORD CAN DESIGN TO A MORE STRINGENT STANDARD, BUT
 UNDER THE 2017
 FBC-B TABLE 508.4 THERE IS NO OCCUPANCY SEPARATION
 REQUIRED BETWEEN A B AND S1 OCCUPANCY. IF THERE IS A
 DIFFERENCE BETWEEN THE FIRE CODE AND BUILDING CODE THEN
 THE MOST STRINGENT CODE PREVAILS.
  
 1I) 2ND REQUEST, SEMI-COMPLIED. YOU HAVE NOT COMPLIED
 WITH THE REQUIREMENTS OF COMMENT 1-C. THIS IS NEW
 CONSTRUCTION, 2 STORY NOT SPRINKLERED REQUIRING AN AREA
 OF REFUGE.
 PLEASE REVIEW IN THE 2003 IBC-B SECTIONS DEALING WITH:
 1007.3 ENCLOSED EXIT STAIRWAYS, 48 INCHES BETWEEN
 HANDRAILS.
 1007.4 ELEVATORS.
 1007.6 AREAS OF REFUGE.
 1007.6.1. SIZE.
 1007.6.2. SEPARATION.
 1007.6.3. TWO-WAY COMMUNICATION.
 1007.6.4. INSTRUCTIONS.
 1007.6.5. IDENTIFICATION.
 1007.7.7. SIGNAGE.
  
  
 1ST ROUND OF COMMENTS. THE LIFE SAFETY SHEET 002-G-101
 SHOWS A SECOND STORY BUSINESS AND STORAGE OCCUPANCY,
 (ASSUMED
 S-1). THE TRAVEL DISTANCE IS SHOWN GOING DOWN THROUGH
 THE STAIRWAY MAKING THIS STAIRWAY EXIT ACCESS AND THE
 TRAVEL DISTANCE ON THE STAIRS TO BE TAKEN PARALLEL TO
 THE STAIRS. FROM THE FURTHEST POINT TAKEN ON THE SECOND
 FLOOR TO THE FIRST FLOOR LANDING THE TRAVEL DISTANCE IS
 BETWEEN 85 TO 90 FEET. THIS IS OVER THE ALLOWABLE
 MAXIMUM COMMON PATH OF TRAVEL FROM TABLE 1006.3.2(2) OF
 75 FEET AND OCCUPANT LOAD OF 49 FOR BUSINESS OR 29 FOR
 STORAGE OCCUPANCY. IF THE STAIRWAY WAS A RATED 1 HOUR
 EXIT STAIRWAY WITH OPENING PROTECTIVES AND EXIT
 PASSAGEWAY TO THE EXTERIOR, THEN THE TRAVEL DISTANCE
 FOR THE 2ND FLOOR WOULD WORK. PLEASE REVIEW ALL OF THE
 REQUIREMENTS FOR EXIT AND EXIT PASSAGEWAYS. EXIT
 PASSAGEWAYS ARE FOUND UNDER FBC-B 1024. PLEASE REVIEW
 VENTILATION REQUIREMENTS (FBC-B 1024.7) FOR EXIT
 PASSAGEWAYS AS WELL.
  
 1J) 2ND REQUEST. VERSION # 2 STILL DOES NOT SHOW
 COMPLIANCE WITH FBC-B 1015.4 OPENING LIMITATIONS.
 REQUIRED GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW
 PASSAGE OF A SPHERE 4 INCHES (102 MM) IN DIAMETER FROM
 THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT. ALSO
 THERE IS A DETAIL FOR RISE AND RUN BUT NO DIMENSION FOR
 COMPLIANCE WITH 1015.4 FBC-B EXCEPTION 2. THE
 TRIANGULAR OPENINGS AT THE OPEN SIDES OF A STAIR,
 FORMED BY THE RISER, TREAD AND BOTTOM RAIL SHALL NOT
 ALLOW PASSAGE OF A SPHERE 6 INCHES IN DIAMETER.
 1 ST ROUND OF COMMENTS. STAIRWAY GUARDRAIL. SHEET
 049-A-101. PLEASE PROVIDE A DETAIL SHOWING COMPLIANCE
 WITH: 2017 FBC-B 1015.4 OPENING LIMITATIONS. REQUIRED
 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW PASSAGE OF A
 SPHERE 4 INCHES (102 MM) IN DIAMETER FROM THE WALKING
 SURFACE TO THE REQUIRED GUARD HEIGHT.
  
 2A) 2ND REQUEST. THERE MUST BE A PERMANENT MEANS OF
 EGRESS TO REACH THE ROOF TOP HATCH.
 1ST ROUND OF COMMENTS. SHEET 042-A102 THE 2ND FLOOR
 PLAN AND ROOF PLAN OF THE REPAIR GARAGE, SHOWS A ROOF
 HATCH TO GAIN ACCESS TO THE MECHANICAL EQUIPMENT ON THE
 ROOF. SHEET 047-A-301 SHOWS A VERTICAL DISTANCE FROM
 THE FINISH FLOOR TO THE BOTTOM OF THE BAR JOIST OF
 14.66 FEET, CENTERED IN THE SERVICE BAY DOORWAY. THE
 VERTICAL DISTANCE FROM FINISH FLOOR TO THE TOP OF THE
 ROOF AT THE ROOF HATCH IS OVER 18.50 FEET. PLEASE SHOW
 HOW COMPLIANCE WITH 306.5 OF THE 2017 MECHANICAL CODE
 WILL BE MET:
 2017 FBC-MECHANICAL. 306.5 EQUIPMENT AND APPLIANCES ON
 ROOFS OR ELEVATED STRUCTURES.
 WHERE EQUIPMENT REQUIRING ACCESS OR APPLIANCES ARE
 LOCATED ON AN ELEVATED STRUCTURE OR THE ROOF OF A
 BUILDING SUCH THAT PERSONNEL WILL HAVE TO CLIMB HIGHER
 THAN 16 FEET (4877 MM) ABOVE GRADE TO ACCESS SUCH
 EQUIPMENT OR APPLIANCES, AN INTERIOR OR EXTERIOR MEANS
 OF ACCESS SHALL BE PROVIDED. SUCH ACCESS SHALL NOT
 REQUIRE CLIMBING OVER OBSTRUCTIONS GREATER THAN 30
 INCHES (762 MM) IN HEIGHT.
  
 2B) 2ND REQUEST. 2017 FBC-B 1015.6 MECHANICAL
 EQUIPMENT. GUARDS SHALL BE PROVIDED WHERE APPLIANCES,
 EQUIPMENT, FANS, ROOF HATCH OPENINGS OR OTHER
 COMPONENTS THAT REQUIRE SERVICE ARE LOCATED WITHIN 10
 FEET (3048 MM) OF A ROOF EDGE OR OPEN SIDE OF A WALKING
 SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN
 30 INCHES ABOVE THE FLOOR, ROOF OR GRADE BELOW. THE
 GUARD SHALL BE CONSTRUCTED SO AS TO PREVENT THE PASSAGE
 OF A SPHERE 21 INCHES IN DIAMETER. THE GUARD SHALL
 EXTEND NOT LESS THAN 30 INCHES BEYOND EACH END OF SUCH
 APPLIANCE, EQUIPMENT, FAN OR COMPONENT.
  
 2C)2ND REQUEST. PLEASE ALSO PROVIDE CODE COMPLIANCE
 WITH: 2017 FBC-B ROOF HATCH EXCEPTION: IN BUILDINGS
 WITHOUT AN OCCUPIED ROOF, ACCESS TO THE ROOF SHALL BE
 PERMITTED TO BE A ROOF HATCH OR TRAP DOOR NOT LESS THAN
 16 SQUARE FEET IN AREA AND HAVING A MINIMUM DIMENSION
 OF 2 FEET.
  
 3) 2ND REQUEST. SHEET 028-S-1.0. EARTHWORK GENERAL
 NOTES: NOTE # 1 INDICATES ALL EARTHWORK SHALL BE DONE
 IN ACCORDANCE WITH THE REQUIREMENTS OUTLINED IN THE
 GEOTECHNICAL REPORT BY UNIVERSAL ENGINEERING SCIENCES.
 REPORT # 16357, DATED APRIL 22, 2019. SUBMIT REPORT.
 PLEASE SHOW COMPLIANCE WITH THE 2017 FBC-B 1803.5.2
 QUESTIONABLE SOIL. WHERE THE CLASSIFICATION, STRENGTH
 OR COMPRESSIBILITY OF THE SOIL IS IN DOUBT OR WHERE A
 LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED IN THIS
 CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL BE
 PERMITTED TO REQUIRE THAT A GEOTECHNICAL INVESTIGATION
 BE CONDUCTED.
 IF THE SOILS REPORT DOES NOT HAVE AN ELECTRONIC
 SIGNATURE, THEN SUBMIT ONE PAPER ORIGINAL WITH
 SIGNATURE AND SEAL. 61G15-23.002 ENGINEER SEAL
 SIGNATURE.
 1ST ROUND OF COMMENTS. SHEET 028-S-1.0. EARTHWORK
 GENERAL NOTES: NOTE # 1 INDICATES ALL EARTHWORK SHALL
 BE DONE IN ACCORDANCE WITH THE REQUIREMENTS OUTLINED IN
 THE GEOTECHNICAL REPORT BY XXXXXXX/ DATE: XXXXX,
 MINIMUM BEARING PRESSURE XXXXXXX. PLEASE SHOW
 COMPLIANCE WITH THE 2017 FBC-B 1803.5.2 QUESTIONABLE
 SOIL. WHERE THE CLASSIFICATION, STRENGTH OR
 COMPRESSIBILITY OF THE SOIL IS IN DOUBT OR WHERE A
 LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED IN THIS
 CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL BE
 PERMITTED TO REQUIRE THAT A GEOTECHNICAL INVESTIGATION
 BE CONDUCTED.
  
 4) COMPLIED. PRESSURES ARE IN VASD AND PRESSURE ZONES
 1-5 ARE GOOD.
  
 5) PROVISO: THIS BUILDING HAS WELDED AND BOLTED STEEL
 CONNECTIONS, PLEASE PROVIDE COMPLIANCE WITH, THE
 CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE
 SPECIFICATIONS & WELDER OPERATOR PERFORMANCE
 QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED
 STANDARDS AT TIME OF INSPECTION.
 2014 FBC-B 2204.1 WELDING
 2014 FBC-B 2204.2 BOLTING.
  
 6) 2ND REQUEST. THE SUBMITTED NOA: 14-0827.18TAMKO
 MODIFIED BITUMEN ROOF SYSTEM OVER STEEL DECK HAS
 VARIOUS SUB-SYSTEMS LISTED WITHIN THE REPORT BUT NONE
 OF THE SUB-SYSTEMS WERE IDENTIFIED AS THE ONE BEING
 INSTALLED. : FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY
 ALL ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES
 FOR ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL
 LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED
 (LIMITATION #7 ALLOWS ENHANCED FASTENING, LIMITATION #
 9 DOES NOT ALLOW ENHANCED FASTENING) FOR ROOF ZONES 2 &
 3. FASTENER DENSITIES SHALL BE INCREASED FOR BOTH
 INSULATION & THE BASE SHEET AS CALCULATED IN COMPLIANCE
 WITH ROOFING APPLICATION STANDARDS RAS 117. CALCULATION
 PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED
 PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT.
 1609.6.4.4.1 COMPONENTS & CLADDING.
  
 7) 2ND REQUEST. THE SUBMITTAL NOA: 16-0219.01 TC-5
 SERIES STEEL ROOF CURB FOR TRANE ROOF TOP UNITS. PLEASE
 REVIEW SHEET 4 AND 5 OF THE PRODUCT APPROVAL FOR
 TECHNICAL NOTES. RESTRAINT BRACKET QUANTITY IS
 DETERMINED BY PROJECT SPECIFIC CALCULATIONS, PERFORMED
 BY A FLORIDA LICENSED PE OR FLORIDA REGISTERED
 ARCHITECT THAT CONSIDER THE UNIQUE COMBINATION OF THE
 UNIT SIZE AND APPLICABLE LATERAL AND UPLIFT PRESSURES
 FOR EACH JOB. PLEASE PROVIDE CALCULATION FOR HOW MANY
 BRACKETS WILL BE NEEDED FOR EACH TYPE OF UNIT.
 107.2.1.3. ADDITIONAL INFORMATION IS REQUIRED. 2017
 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL EQUIPMENT,
 APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO WIND SHALL
 BE DESIGNED AND INSTALLED TO RESIST THE WIND PRESSURES
 DETERMINED IN ACCORDANCE WITH THE FLORIDA BUILDING
 CODE, BUILDING.
  
 8) 2ND REQUEST. THE SUBMITTAL NOA: 17-1017.14 TRULITE
 SERIES 3100 REGISTER ALUMINUM STOREFRONT/ WINDOW WALL
 SYSTEM- L. M. I. SHEETS 2-5 DO NOT OPEN FOR REVIEW.
 PLEASE NOTE ON PAGE 6 ONLY THE BOTTOM SERIES OF GLASS
 IS HIGHLIGHTED FOR PRESSURES. THE UPPER WINDOW GLASS IS
 NOT MENTIONED. THE UPPER GLAZING UNITS WHICH HAVE BOTH
 VERTICAL AND HORIZONTAL FRAMING MEMBERS ARE NOT
 IDENTIFIED ON SHEETS 8 AND 9 OF THE REPORT NOR IS THE
 CHART HIGHLIGHTED OR CIRCLED TO IF THE JAMBS ARE
 REQUIRED TO BE STEEL RE-ENFORCED. SHEET 10 OF 17 THE
 DOOR MULLION INDICATES TRULITE DOORS ARE UNDER A
 SEPARATE NOA. SHEET 13 OF 17 THE ANCHOR LOAD CHART IS
 NOT IDENTIFIED AS TO THE TYPE OF ANCHOR FOR THE FRAME
 WIDTH AND HEIGHT.
 IDENTIFY GLAZING/ MULLIONS.
 PLEASE IDENTIFY ON THE PRODUCT APPROVAL BEFORE
 SUBMITTING TO DESIGNER OF RECORD AND BEFORE SUBMISSION
 TO THE BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH
 GLAZING, PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT,
 TYPE OF GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED
 OR REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND
 ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2017 FBC-B
 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE
 INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER?S
 INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE
 PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED
 BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS.
  
 9) 2ND REQUEST. GENSTEEL SERIES GENSTORM OUTSWING DOOR
 NOA: 17-0803.01 PLEASE PROVIDE THE TYPE OF LOCK OPTION
 THAT WILL BE USED WITH THIS DOOR. SEE SHEET 9 OF 11.
  
 10) 2ND REQUEST. THE SUBMITTAL NOA: 17-1218.02 MIAMI
 TECH ALUMINUM A/C STAND. THE ROOF TOP A/C STAND PRODUCT
 APPROVAL A MIAMI-DADE NOA # 17-1218.02 WAS SUBMITTED,
 REVIEWED BY THE DESIGNER OF RECORD. PLEASE IDENTIFY THE
 FOLLOWING REQUIREMENTS CALCULATING THE AREA (SIDE VIEW)
 OF THE ROOF TOP COMPRESSORS, CONFIGURATION ON STAND,
 THE MEAN ROOF HEIGHT OF THE STAND AND COMPRESSORS,
 WEIGHT, CIRCLED THE DESIGN PARAMETERS IN THE TABLES,
 ANCHORS AND UPLIFT VERSES MOMENT FOR THE UNIT TO THE
 STAND AND THE STAND TO THE ROOF. THE PRODUCT APPROVAL
 IS TO BE REVIEWED BY THE DESIGNER OF RECORD, APPROVED
 BEFORE SUBMISSION TO THE BUILDING DEPARTMENT.
  
 11) THE PERMIT APPLICATION INDICATES THAT THE SQUARE
 FOOTAGE OF THE AUTO DEALERSHIP BEING 15,805 SQ. FT.
 THAT WOULD APPEAR TO BE THE 1ST FLOOR ONLY. THE TOTAL
 SQ. FOOTAGE I CALCULATED WAS 18,534.00 SQ. FT.
 DISCREPANCY IN SQ. FT.
  
 108.3* BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 THIS MAIN BUILDING PERMIT WILL INCLUDE THE FEES FOR THE
 MECHANICAL, ELECTRICAL, PLUMBING & ROOFING PERMITS.
 WHEN THE GENERAL CONTRACTOR COMES IN FOR A BUILDING
 PERMIT WITH THE SIGNED PERMIT APPLICATION FORM BY THE
 QUALIFIER AND OWNER AND BRINGS IN THE LISTED
 SUB-PERMITS M-E-P & ROOFING PERMITS SIGNED BY THE
 QUALIFIER OF EACH COMPANY, THEIR INSURANCES AND
 LICENSURE UP TO DATE, THE M-E-P AND ROOFING PERMITS ARE
 FREE OF CHARGE. IF THE M-E-P & ROOFING PERMITS COME IN
 LATER THERE WILL BE AN $80.00 ADMINISTRATIVE FEE FOR
 EACH PERMIT.
  
 ALL OTHER PERMITS FIRE SPRINKLER, FIRE ALARM, RACK
 STORAGE, EXHAUST HOODS, ANSUL SYSTEMS OR ALTERNATIVE
 AUTOMATIC FIRE-EXTINGUISHING SYSTEMS, WALK IN COOLERS &
 FREEZERS, ALL LOW VOLTAGE PERMITS, GENERATORS & FUEL
 TANKS, GAS PERMIT, POOL, JACUZZI AND ASSOCIATED
 SUB-PERMITS, AWNING, SCREEN ENCLOSURES, CANOPY, FENCE,
 LANDSCAPE, IRRIGATION, AUGER CAST PILE AND OR
 FOUNDATION OR STRUCTURE ONLY PERMIT WILL BE SEPARATE
 REVIEWS AND ASSOCIATED FEES WITH EACH PERMIT.
 PLEASE PROVIDE AN ITEMIZED LIST AND SUBTRACT THESE LINE
 ITEMS AND THEIR VALUE FROM THE OVERALL BUILDING VALUE
 STATED ON THE PERMIT APPLICATION FOR THIS PROJECT. THE
 REMAINING BALANCE WILL BE AFFECTIVELY THE VALUE OF THE
 BUILDING YOU WILL BE PAYING FOR THIS PERMIT. THE
 BUILDING DEPARTMENT DOES NOT WANT TO COLLECT TWICE FOR
 THE VALUE OF THESE SUB-PERMITS NOT COVERED UNDER THE
 PRIME OR MASTER PERMIT.
  
 12) 2ND REQUEST. INFORMATION REQUIRED, SINCE THIS
 PROJECT IS A NEW AUTOMOBILE DEALERSHIP WILL THEY BE
 FILLING THE CARS WITH GASOLINE? I DIDN'T SEE TANKS ON
 ANY PLAN, ARE THEY TO BE ABOVE GROUND OR BENEATH THE
 GROUND? NOTE PETROLEUM TANKS ARE TO BE REVIEWED UNDER
 SEPARATE PERMIT, FEES AND REVIEWS.
 107.2.1.2. ADDITIONAL INFORMATION IS REQUIRED.
  
 13) INFORMATIONAL: ART IN PUBLIC PLACES
 THE CITY OF WEST PALM BEACH ART IN PUBLIC PLACES
 ORDINANCE REQUIREMENT THAT APPLIES TO ANY REMODEL OR
 NEW CONSTRUCTION PROJECT FOR WHICH THE PERMIT
 APPLICATION WAS SUBMITTED AFTER 6/29/14, AND THE TOTAL
 PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN
 $750,000 WILL NEED TO COMPLY WITH THIS ORDINANCE.
 PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND
 CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V,
 ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION
 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL
 PROJECT CONSTRUCTION COST.
 PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE
 V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND
 NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO
 THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE
 PROJECTS.
 SEC. 78-129. - PUBLIC ART ASSESSMENT FOR PRIVATE
 DEVELOPMENT.
 (A) APPLICABILITY. THE PROVISIONS OF THIS ARTICLE AND
 THE PUBLIC ART ASSESSMENT SECTION SHALL APPLY TO ALL
 PRIVATE DEVELOPMENT PROJECTS, INCLUDING NEW
 CONSTRUCTION, OR THE RENOVATION OR IMPROVEMENT OF AN
 EXISTING BUILDING, WHERE TOTAL CONSTRUCTION COSTS ARE
 EQUAL TO OR GREATER THAN $750,000.00. ALL BUILDINGS
 WITHIN NEW PLANNED DEVELOPMENTS SHALL BE ASSESSED
 CUMULATIVELY TOWARDS THIS ART IN PUBLIC PLACES
 REQUIREMENT, EVEN IF THE BUILDINGS ARE PERMITTED
 SEPARATELY OR DEVELOPED IN PHASES. THE PROVISIONS OF
 THIS SECTION APPLY TO NEW DEVELOPMENT OR NEW
 CONSTRUCTION WITHIN EXISTING PLANNED DEVELOPMENTS.
 FOR CONTACT INFORMATION PLEASE CONTACT:
 MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR
 822-1515 E-MAIL: [email protected]
  
 14) 2ND REQUEST. IMPACT FEES - DIGITAL SUBMITTALS:
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
 PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300
 N. JOG RD. ROOM?S 2W01-2W14 WEST PALM BEACH, FL.
  
 15) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-05-30 Cont ID  
Sent By jwitmer Date 2019-05-30 Time 09:06 Rev Time 0.00
Received By jwitmer Date 2019-05-28 Time 13:02 Sent To  
Notes
2019-05-30 09:06:072017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 19040448
 ADD: 2700 S AUSTRALIAN AVE.
 CONT: AUTOBUILDERS GENERAL CONT. SVCS. INC.
 TEL: 561-622-3515
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. MAY 29/2019
 ACTION: DENIED
  
 1) SHEET 002-G-101 THE LIFE SAFETY PLAN:
 1A). UNDER THE HEADING BUILDING CODE SUMMARY THE
 PROPOSED USE IS LISTED AS BUSINESS (B) AND STORAGE
 (S1). PLEASE NOTE THAT THE SERVICE SHOP IS LISTED AS A
 S1 OCCUPANCY. FOR MOTOR VEHICLE REPAIR GARAGES
 COMPLYING WITH THE MAXIMUM ALLOWABLE QUANTITIES OF
 HAZARDOUS MATERIALS LISTED IN TABLE 307.1(1).
 PLEASE SUBMIT A LIST OF HAZARDOUS MATERIALS AND
 ALLOWABLE QUANTITIES PER THE 2017 FBC-B TABLE 307.1(1).
  
 1B) UNDER THE HEADING OF BUILDING DATA THE PLANS ARE
 INDICATED THEY ARE DESIGNED UNDER THE 2014 FBC. PLEASE
 NOTE THAT THE 2017 FBC-B WAS ADOPTED STATEWIDE ON DEC.
 31/ 2017. PLEASE UPDATE PLANS.
  
 1C) UNDER THE BUILDING DATA THERE IS NO LISTING FOR THE
 REQUIRED AREA OF REFUGE, THIS IS A 2 STORY BUILDING AND
 NO FIRE SPRINKLERS. THE 2017 FBC-ACCESSIBILITY CODE
 UNDER SECTION 207 ACCESSIBLE MEANS OF EGRESS. SECTION
 207.1. MEANS OF EGRESS SHALL COMPLY WITH SECTION 1007
 OF THE INTERNATIONAL BUILDING CODE (2003 EDITION).
 PLEASE REVIEW IN THE 2003 IBC-B SECTIONS DEALING WITH:
 1007.3 ENCLOSED EXIT STAIRWAYS, 48 INCHES BETWEEN
 HANDRAILS.
 1007.4 ELEVATORS.
 1007.6 AREAS OF REFUGE.
 1007.6.1. SIZE.
 1007.6.2. SEPARATION.
 1007.6.3. TWO-WAY COMMUNICATION.
 1007.6.4. INSTRUCTIONS.
 1007.6.5. IDENTIFICATION.
 1007.7.7. SIGNAGE.
  
 1D) SEPARATED MIXED OCCUPANCY SHOWS THE FORMULA FOR
 AREA CALCULATIONS BUT HAS LEFT THE CALCULATION BLANK.
 PLEASE PROVIDE THE ACTUAL AND ALLOWABLE SQUARE FEET FOR
 EACH OF THE OCCUPANCIES AND THE END CALCULATION. 2017
 FBC-B 508.3.3.
  
 1E) PLEASE NOTE THE PLANS DOES NOT STATE THE ACTUAL
 OCCUPANT LOAD FOR EACH OF THE OCCUPANCIES. THE EXIT
 WIDTH DOES PROVIDE THE AREA FOR EACH OCCUPANCY AND AREA
 PER OCCUPANT (TABLE 1004.1.2) BUT DOES NOT GIVE THE
 ACTUAL OCCUPANT LOAD PER STORY AND THE TOTAL OCCUPANT
 LOAD. 2017 FBC-B 1004.1 & TABLE 1004.1.2.
  
 1F) THE LIFE SAFETY SHEET 002-G-101 UNDER THE HEADING
 OF ALLOWABLE AREA, MIXED OCCUPANCY INDICATES YES, AND
 SEPARATION 2 HRS. THE FIRST FLOOR PARTS ROOM HAS A NOTE
 2 HRS. IT WOULD APPEAR THAT THIS NOTE REFERS TO THE
 BLOCK WALL BETWEEN THE BUSINESS OCCUPANCY AND S1 REPAIR
 GARAGE. THE FIRST FLOOR PLAN SHEET 041-A-101 HAS THIS
 SAME WALL WITH A WALL IDENTIFICATION TAG IDENTIFIED AS
 WALL TYPE 10. SHEET 042-A-102 THE SECOND FLOOR HAS THE
 SAME WALL TYPE IDENTIFIED WITH A WALL IDENTIFICATION
 TAG AS WALL TYPE 6. WHEN YOU OPEN UP SHEET 050-A-501
 WALL TYPES NONE OF THE WALL TYPES SHOWN HAVE THE SAME
 NAMING CONVENTION.
  
 1G) SHEET A-501 WALL TYPES A3-A6 ALL SHOW BLOCK WALLS
 WITH EITHER 8 INCH OR 12 INCH CMU. INFORMATION ON THE
 PLANS HAS TO BE SPECIFIC NO EITHER, OR. SUCH DRAWINGS
 AND SPECIFICATIONS SHALL CONTAIN INFORMATION, IN THE
 FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC. 107.2.1 INFORMATION ON CONSTRUCTION
 DOCUMENTS.
  
 1H) PLEASE NOTE THE DESIGNER OF RECORD CAN DESIGN TO A
 MORE STRINGENT STANDARD, BUT UNDER THE 2017
 FBC-B TABLE 508.4 THERE IS NO OCCUPANCY SEPARATION
 REQUIRED BETWEEN A B AND S1 OCCUPANCY. IF THERE IS A
 DIFFERENCE BETWEEN THE FIRE CODE AND BUILDING CODE THEN
 THE MOST STRINGENT CODE PREVAILS.
  
 1I) THE LIFE SAFETY SHEET 002-G-101 SHOWS A SECOND
 STORY BUSINESS AND STORAGE OCCUPANCY,
 (ASSUMED S-1). THE TRAVEL DISTANCE IS SHOWN GOING DOWN
 THROUGH THE STAIRWAY MAKING THIS STAIRWAY EXIT ACCESS
 AND THE TRAVEL DISTANCE ON THE STAIRS TO BE TAKEN
 PARALLEL TO THE STAIRS. FROM THE FURTHEST POINT TAKEN
 ON THE SECOND FLOOR TO THE FIRST FLOOR LANDING THE
 TRAVEL DISTANCE IS BETWEEN 85 TO 90 FEET. THIS IS OVER
 THE ALLOWABLE MAXIMUM COMMON PATH OF TRAVEL FROM TABLE
 1006.3.2(2) OF 75 FEET AND OCCUPANT LOAD OF 49 FOR
 BUSINESS OR 29 FOR STORAGE OCCUPANCY. IF THE STAIRWAY
 WAS A RATED 1 HOUR EXIT STAIRWAY WITH OPENING
 PROTECTIVES AND EXIT PASSAGEWAY TO THE EXTERIOR, THEN
 THE TRAVEL DISTANCE FOR THE 2ND FLOOR WOULD WORK.
 PLEASE REVIEW ALL OF THE REQUIREMENTS FOR EXIT AND EXIT
 PASSAGEWAYS. EXIT PASSAGEWAYS ARE FOUND UNDER FBC-B
 1024. PLEASE REVIEW VENTILATION REQUIREMENTS (FBC-B
 1024.7) FOR EXIT PASSAGEWAYS AS WELL.
  
 1J) STAIRWAY GUARDRAIL. SHEET 049-A-101. PLEASE PROVIDE
 A DETAIL SHOWING COMPLIANCE WITH:
 2017 FBC-B 1015.4 OPENING LIMITATIONS. REQUIRED GUARDS
 SHALL NOT HAVE OPENINGS THAT ALLOW PASSAGE OF A SPHERE
 4 INCHES (102 MM) IN DIAMETER FROM THE WALKING SURFACE
 TO THE REQUIRED GUARD HEIGHT.
  
 2A) SHEET 042-A102 THE 2ND FLOOR PLAN AND ROOF PLAN OF
 THE REPAIR GARAGE, SHOWS A ROOF HATCH TO GAIN ACCESS TO
 THE MECHANICAL EQUIPMENT ON THE ROOF. SHEET 047-A-301
 SHOWS A VERTICAL DISTANCE FROM THE FINISH FLOOR TO THE
 BOTTOM OF THE BAR JOIST OF 14.66 FEET, CENTERED IN THE
 SERVICE BAY DOORWAY. THE VERTICAL DISTANCE FROM FINISH
 FLOOR TO THE TOP OF THE ROOF AT THE ROOF HATCH IS OVER
 18.50 FEET. PLEASE SHOW HOW COMPLIANCE WITH 306.5 OF
 THE 2017 MECHANICAL CODE WILL BE MET:
 2017 FBC-MECHANICAL. 306.5 EQUIPMENT AND APPLIANCES ON
 ROOFS OR ELEVATED STRUCTURES.
 WHERE EQUIPMENT REQUIRING ACCESS OR APPLIANCES ARE
 LOCATED ON AN ELEVATED STRUCTURE OR THE ROOF OF A
 BUILDING SUCH THAT PERSONNEL WILL HAVE TO CLIMB HIGHER
 THAN 16 FEET (4877 MM) ABOVE GRADE TO ACCESS SUCH
 EQUIPMENT OR APPLIANCES, AN INTERIOR OR EXTERIOR MEANS
 OF ACCESS SHALL BE PROVIDED. SUCH ACCESS SHALL NOT
 REQUIRE CLIMBING OVER OBSTRUCTIONS GREATER THAN 30
 INCHES (762 MM) IN HEIGHT.
  
 2B) 2017 FBC-B 1015.6 MECHANICAL EQUIPMENT. GUARDS
 SHALL BE PROVIDED WHERE APPLIANCES, EQUIPMENT, FANS,
 ROOF HATCH OPENINGS OR OTHER COMPONENTS THAT REQUIRE
 SERVICE ARE LOCATED WITHIN 10 FEET (3048 MM) OF A ROOF
 EDGE OR OPEN SIDE OF A WALKING SURFACE AND SUCH EDGE OR
 OPEN SIDE IS LOCATED MORE THAN 30 INCHES ABOVE THE
 FLOOR, ROOF OR GRADE BELOW. THE GUARD SHALL BE
 CONSTRUCTED SO AS TO PREVENT THE PASSAGE OF A SPHERE 21
 INCHES IN DIAMETER. THE GUARD SHALL EXTEND NOT LESS
 THAN 30 INCHES BEYOND EACH END OF SUCH APPLIANCE,
 EQUIPMENT, FAN OR COMPONENT.
  
 2C) PLEASE ALSO PROVIDE CODE COMPLIANCE WITH: 2017
 FBC-B ROOF HATCH EXCEPTION: IN BUILDINGS WITHOUT AN
 OCCUPIED ROOF, ACCESS TO THE ROOF SHALL BE PERMITTED TO
 BE A ROOF HATCH OR TRAP DOOR NOT LESS THAN 16 SQUARE
 FEET IN AREA AND HAVING A MINIMUM DIMENSION OF 2 FEET.
  
 3) SHEET 028-S-1.0. EARTHWORK GENERAL NOTES: NOTE # 1
 INDICATES ALL EARTHWORK SHALL BE DONE IN ACCORDANCE
 WITH THE REQUIREMENTS OUTLINED IN THE GEOTECHNICAL
 REPORT BY XXXXXXX/ DATE: XXXXX, MINIMUM BEARING
 PRESSURE XXXXXXX. PLEASE SHOW COMPLIANCE WITH THE 2017
 FBC-B 1803.5.2 QUESTIONABLE SOIL. WHERE THE
 CLASSIFICATION, STRENGTH OR COMPRESSIBILITY OF THE SOIL
 IS IN DOUBT OR WHERE A LOAD-BEARING VALUE SUPERIOR TO
 THAT SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING
 OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A
 GEOTECHNICAL INVESTIGATION BE CONDUCTED.
  
 4) SHEET 029-S-1.1 PROVIDES THE WIND PRESSURES (VASD)
 FOR WALL ZONES 4 & 5 BUT THERE ARE NO PRESSURES FOR
 ROOF ZONES 1, 2 OR 3. 2017 FBC-B 1603.1.4. WIND DESIGN
 DATA.
  
 5) THIS BUILDING HAS WELDED AND BOLTED STEEL
 CONNECTIONS, PLEASE PROVIDE COMPLIANCE WITH, THE
 CONTRACTOR IS REQUIRED TO PROVIDE WELD PROCEDURE
 SPECIFICATIONS & WELDER OPERATOR PERFORMANCE
 QUALIFICATION RECORDS IN ACCORDANCE WITH THE REFERENCED
 STANDARDS AT TIME OF INSPECTION.
 2014 FBC-B 2204.1 WELDING
 2014 FBC-B 2204.2 BOLTING.
  
 6) THE SUBMITTED NOA: 14-0827.18TAMKO MODIFIED BITUMEN
 ROOF SYSTEM OVER STEEL DECK HAS VARIOUS SUB-SYSTEMS
 LISTED WITHIN THE REPORT BUT NONE OF THE SUB-SYSTEMS
 WERE IDENTIFIED AS THE ONE BEING INSTALLED. : FOR ALL
 ROOFING PRODUCTS PLEASE IDENTIFY ALL ROOFING
 SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR ROOF
 ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, IF
 ENHANCED FASTENING IS ALLOWED
 (LIMITATION #7 ALLOWS ENHANCED FASTENING, LIMITATION #
 9 DOESN?T) FOR ROOF ZONES 2 & 3. FASTENER DENSITIES
 SHALL BE INCREASED FOR BOTH INSULATION & THE BASE SHEET
 AS CALCULATED IN COMPLIANCE WITH ROOFING APPLICATION
 STANDARDS RAS 117. CALCULATION PREPARED, SIGNED AND
 SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR
 REGISTERED ARCHITECT. 1609.6.4.4.1 COMPONENTS &
 CLADDING.
  
 7) THE SUBMITTAL NOA: 16-0219.01 TC-5SERIES STEEL ROOF
 CURB FOR TRANE ROOF TOP UNITS. PLEASE REVIEW SHEET 4
 AND 5 OF THE PRODUCT APPROVAL FOR TECHNICAL NOTES.
 RESTRAINT BRACKET QUANTITY IS DETERMINED BY PROJECT
 SPECIFIC CALCULATIONS, PERFORMED BY A FLORIDA LICENSED
 PE OR FLORIDA REGISTERED ARCHITECT THAT CONSIDER THE
 UNIQUE COMBINATION OF THE UNIT SIZE AND APPLICABLE
 LATERAL AND UPLIFT PRESSURES FOR EACH JOB. PLEASE
 PROVIDE CALCULATION FOR HOW MANY BRACKETS WILL BE
 NEEDED FOR EACH TYPE OF UNIT. 107.2.1.3. ADDITIONAL
 INFORMATION IS REQUIRED. 2017 FBC-M- 301.15 WIND
 RESISTANCE. MECHANICAL EQUIPMENT, APPLIANCES AND
 SUPPORTS THAT ARE EXPOSED TO WIND SHALL BE DESIGNED AND
 INSTALLED TO RESIST THE WIND PRESSURES DETERMINED IN
 ACCORDANCE WITH THE FLORIDA BUILDING CODE, BUILDING.
  
 8) THE SUBMITTAL NOA: 17-1017.14 TRULITE SERIES 3100
 REGISTER ALUMINUM STOREFRONT/ WINDOW WALL SYSTEM- L. M.
 I. SHEETS 2-5 DO NOT OPEN FOR REVIEW. PLEASE NOTE ON
 PAGE 6 ONLY THE BOTTOM SERIES OF GLASS IS HIGHLIGHTED
 FOR PRESSURES. THE UPPER WINDOW GLASS IS NOT MENTIONED.
 THE UPPER GLAZING UNITS WHICH HAVE BOTH VERTICAL AND
 HORIZONTAL FRAMING MEMBERS ARE NOT IDENTIFIED ON SHEETS
 8 AND 9 OF THE REPORT NOR IS THE CHART HIGHLIGHTED OR
 CIRCLED TO IF THE JAMBS ARE REQUIRED TO BE STEEL
 RE-ENFORCED. SHEET 10 OF 17 THE DOOR MULLION INDICATES
 TRULITE DOORS ARE UNDER A SEPARATE NOA. SHEET 13 OF 17
 THE ANCHOR LOAD CHART IS NOT IDENTIFIED AS TO THE TYPE
 OF ANCHOR FOR THE FRAME WIDTH AND HEIGHT.
 IDENTIFY GLAZING/ MULLIONS.
 PLEASE IDENTIFY ON THE PRODUCT APPROVAL BEFORE
 SUBMITTING TO DESIGNER OF RECORD AND BEFORE SUBMISSION
 TO THE BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH
 GLAZING, PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT,
 TYPE OF GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED
 OR REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND
 ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2017 FBC-B
 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE
 INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER?S
 INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE
 PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED
 BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS.
  
 9) GENSTEEL SERIES GENSTORM OUTSWING DOOR NOA:
 17-0803.01 PLEASE PROVIDE THE TYPE OF LOCK OPTION THAT
 WILL BE USED WITH THIS DOOR. SEE SHEET 9 OF 11.
  
 10) THE SUBMITTAL NOA: 17-1218.02 MIAMI TECH ALUMINUM
 A/C STAND. THE ROOF TOP A/C STAND PRODUCT APPROVAL A
 MIAMI-DADE NOA # 17-1218.02 WAS SUBMITTED, REVIEWED BY
 THE DESIGNER OF RECORD. PLEASE IDENTIFY THE FOLLOWING
 REQUIREMENTS CALCULATING THE AREA (SIDE VIEW) OF THE
 ROOF TOP COMPRESSORS, CONFIGURATION ON STAND, THE MEAN
 ROOF HEIGHT OF THE STAND AND COMPRESSORS, WEIGHT,
 CIRCLED THE DESIGN PARAMETERS IN THE TABLES, ANCHORS
 AND UPLIFT VERSES MOMENT FOR THE UNIT TO THE STAND AND
 THE STAND TO THE ROOF. THE PRODUCT APPROVAL IS TO BE
 REVIEWED BY THE DESIGNER OF RECORD, APPROVED BEFORE
 SUBMISSION TO THE BUILDING DEPARTMENT.
  
 11) THE PERMIT APPLICATION INDICATES THAT THE SQUARE
 FOOTAGE OF THE AUTO DEALERSHIP BEING 15,805 SQ. FT.
 THAT WOULD APPEAR TO BE THE 1ST FLOOR ONLY. THE TOTAL
 SQ. FOOTAGE I CALCULATED WAS 18,534.00 SQ. FT.
 DISCREPANCY IN SQ. FT.
  
 108.3* BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 THIS MAIN BUILDING PERMIT WILL INCLUDE THE FEES FOR THE
 MECHANICAL, ELECTRICAL, PLUMBING & ROOFING PERMITS.
 WHEN THE GENERAL CONTRACTOR COMES IN FOR A BUILDING
 PERMIT WITH THE SIGNED PERMIT APPLICATION FORM BY THE
 QUALIFIER AND OWNER AND BRINGS IN THE LISTED
 SUB-PERMITS M-E-P & ROOFING PERMITS SIGNED BY THE
 QUALIFIER OF EACH COMPANY, THEIR INSURANCES AND
 LICENSURE UP TO DATE, THE M-E-P AND ROOFING PERMITS ARE
 FREE OF CHARGE. IF THE M-E-P & ROOFING PERMITS COME IN
 LATER THERE WILL BE AN $80.00 ADMINISTRATIVE FEE FOR
 EACH PERMIT.
  
 ALL OTHER PERMITS FIRE SPRINKLER, FIRE ALARM, RACK
 STORAGE, EXHAUST HOODS, ANSUL SYSTEMS OR ALTERNATIVE
 AUTOMATIC FIRE-EXTINGUISHING SYSTEMS, WALK IN COOLERS &
 FREEZERS, ALL LOW VOLTAGE PERMITS, GENERATORS & FUEL
 TANKS, GAS PERMIT, POOL, JACUZZI AND ASSOCIATED
 SUB-PERMITS, AWNING, SCREEN ENCLOSURES, CANOPY, FENCE,
 LANDSCAPE, IRRIGATION, AUGER CAST PILE AND OR
 FOUNDATION OR STRUCTURE ONLY PERMIT WILL BE SEPARATE
 REVIEWS AND ASSOCIATED FEES WITH EACH PERMIT.
 PLEASE PROVIDE AN ITEMIZED LIST AND SUBTRACT THESE LINE
 ITEMS AND THEIR VALUE FROM THE OVERALL BUILDING VALUE
 STATED ON THE PERMIT APPLICATION FOR THIS PROJECT. THE
 REMAINING BALANCE WILL BE AFFECTIVELY THE VALUE OF THE
 BUILDING YOU WILL BE PAYING FOR THIS PERMIT. THE
 BUILDING DEPARTMENT DOES NOT WANT TO COLLECT TWICE FOR
 THE VALUE OF THESE SUB-PERMITS NOT COVERED UNDER THE
 PRIME OR MASTER PERMIT.
  
 12) INFORMATION REQUIRED, SINCE THIS PROJECT IS A NEW
 AUTOMOBILE DEALERSHIP WILL THEY BE FILLING THE CARS
 WITH GASOLINE? I DIDN'T SEE TANKS ON ANY PLAN, ARE THEY
 TO BE ABOVE GROUND OR BENEATH THE GROUND? NOTE
 PETROLEUM TANKS ARE TO BE REVIEWED UNDER SEPARATE
 PERMIT, FEES AND REVIEWS.
 107.2.1.2. ADDITIONAL INFORMATION IS REQUIRED.
  
 13) ART IN PUBLIC PLACES
 THE CITY OF WEST PALM BEACH ART IN PUBLIC PLACES
 ORDINANCE REQUIREMENT THAT APPLIES TO ANY REMODEL OR
 NEW CONSTRUCTION PROJECT FOR WHICH THE PERMIT
 APPLICATION WAS SUBMITTED AFTER 6/29/14, AND THE TOTAL
 PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN
 $750,000 WILL NEED TO COMPLY WITH THIS ORDINANCE.
 PER CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND
 CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V,
 ART IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION
 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL
 PROJECT CONSTRUCTION COST.
 PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE
 V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND
 NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO
 THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE
 PROJECTS.
 SEC. 78-129. - PUBLIC ART ASSESSMENT FOR PRIVATE
 DEVELOPMENT.
 (A) APPLICABILITY. THE PROVISIONS OF THIS ARTICLE AND
 THE PUBLIC ART ASSESSMENT SECTION SHALL APPLY TO ALL
 PRIVATE DEVELOPMENT PROJECTS, INCLUDING NEW
 CONSTRUCTION, OR THE RENOVATION OR IMPROVEMENT OF AN
 EXISTING BUILDING, WHERE TOTAL CONSTRUCTION COSTS ARE
 EQUAL TO OR GREATER THAN $750,000.00. ALL BUILDINGS
 WITHIN NEW PLANNED DEVELOPMENTS SHALL BE ASSESSED
 CUMULATIVELY TOWARDS THIS ART IN PUBLIC PLACES
 REQUIREMENT, EVEN IF THE BUILDINGS ARE PERMITTED
 SEPARATELY OR DEVELOPED IN PHASES. THE PROVISIONS OF
 THIS SECTION APPLY TO NEW DEVELOPMENT OR NEW
 CONSTRUCTION WITHIN EXISTING PLANNED DEVELOPMENTS.
 FOR CONTACT INFORMATION PLEASE CONTACT:
 MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR
 822-1515 E-MAIL: [email protected]
  
 14) IMPACT FEES - DIGITAL SUBMITTALS:
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
 PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300
 N. JOG RD. ROOM?S 2W01-2W14 WEST PALM BEACH, FL.
  
 15) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2019-10-15 Cont ID  
Sent By jleahy Date 2019-10-15 Time 12:56 Rev Time 0.00
Received By jleahy Date 2019-10-15 Time 12:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-08-08 Cont ID  
Sent By jleahy Date 2019-08-08 Time 16:01 Rev Time 0.00
Received By jleahy Date 2019-08-07 Time 11:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-05-09 Cont ID  
Sent By jleahy Date 2019-05-09 Time 11:53 Rev Time 0.00
Received By jleahy Date 2019-05-09 Time 11:53 Sent To  
Notes
2019-05-09 12:28:50ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 FLORIDA BUILDING CODE 2017 6TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 6TH ED
 NFPA 70 2014 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) NEED LOAD CALCULATION FOR SIZING THE SERVIE
  
 2) NEED LOAD CALCULATION FOR SIZING THE GENERATOR
  
 3) NEED LOAD CALCULATION FOR THE ATS
  
 4) ATS WILL HAVE TO MEET THE REQUIREMENTS ON 240.87
  
 240.87 ARC ENERGY REDUCTION
 WHERE THE HIGHEST CONTINUOUS CURRENT TRIP SETTING FOR
 WHICH THE
 ACTUAL OVERCURRENT DEVICE INSTALLED IN A CIRCUIT
 BREAKER IS RATED
 OR CAN BE ADJUSTED IS 1200 A OR HIGHER, 240.87(A) AND
 (B) SHALL
 APPLY

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2019-10-15 Cont ID  
Sent By jleahy Date 2019-10-15 Time 12:57 Rev Time 0.00
Received By jleahy Date 2019-10-15 Time 12:57 Sent To  
Notes
2019-10-15 13:01:41TELEPHONE AND DATA ONLY

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2019-09-24 Cont ID  
Sent By rrossano Date 2019-09-24 Time   Rev Time 0.00
Received By rrossano Date 2019-09-24 Time   Sent To  
Notes
2019-09-24 06:56:10REVIEWED UNDER FORMAL ENGINEERING SUBMITTAL E19030008.

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2019-07-26 Cont ID  
Sent By shill Date 2019-07-26 Time 16:31 Rev Time 0.00
Received By shill Date 2019-07-26 Time 16:31 Sent To  
Notes
2019-07-26 16:31:48CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT
 APPLICATION IF REQUIRED
 HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS
 /FORMS,-PERMITS-APPLICATIONS
  
 ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE
  
 MAIN PHONE: (561) 822-1200
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2019-04-30 Cont ID  
Sent By shill Date 2019-04-30 Time 10:34 Rev Time 0.00
Received By shill Date 2019-04-30 Time 16:31 Sent To  
Notes
2019-04-30 10:34:17CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT
 APPLICATION IF REQUIRED
 HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS
 /FORMS,-PERMITS-APPLICATIONS
  
 ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE
  
 MAIN PHONE: (561) 822-1200
  
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2019-11-25 Cont ID  
Sent By pleduc Date 2019-11-25 Time   Rev Time 0.00
Received By pleduc Date 2019-11-25 Time 10:10 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2019-10-10 Cont ID  
Sent By pleduc Date 2019-10-10 Time   Rev Time 0.00
Received By pleduc Date 2019-10-10 Time 12:07 Sent To  
Notes
2019-10-10 12:16:42NO NOTES
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-07-22 Cont ID  
Sent By pleduc Date 2019-07-22 Time   Rev Time 0.00
Received By pleduc Date 2019-07-22 Time 09:13 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2019-04-29 Cont ID  
Sent By pleduc Date 2019-04-29 Time 09:39 Rev Time 0.00
Received By pleduc Date 2019-04-24 Time 15:14 Sent To  
Notes
2019-04-25 15:22:21 
 THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) LIFE SAFETY SHEETS - THERE ARE NO INDICATIONS OF
 OCCUPANCY LOADS ON EACH FLOOR.
  
 PER NFPA 101 CH 38
  
 38.1.7 OCCUPANT LOAD. THE OCCUPANT LOAD, IN NUMBER OF
 PERSONS FOR
 WHOM MEANS OF EGRESS AND OTHER PROVISIONS ARE REQUIRED,
 SHALL BE
 DETERMINED ON THE BASIS OF THE OCCUPANT LOAD FACTORS
 THAT ARE
 CHARACTERISTIC OF THE USE OF THE SPACE OR SHALL BE
 DETERMINED AS THE
 MAXIMUM PROBABLE POPULATION OF THE SPACE UNDER
 CONSIDERATION,
 WHICHEVER IS GREATER.
  
 PLEASE CORRECT AND PROVIDE.
  
  
  
 2) SHEET G 101 - THERE IS ONLY ONE EXIT INDICATED FROM
 THE 2ND FLOOR.
  
 PER NFPA 101, CH 38 NEW BUSINESS: SEE (3) (A). THERE
 ARE TWO DOOR OPENINGS INDICATED TO OTHER PARTS OF THE
 BUILDING; PARTS WAREHOUSE & ELEVATOR LOBBY.
  
 38.2.4 NUMBER OF MEANS OF EGRESS.
 38.2.4.1 MEANS OF EGRESS SHALL COMPLY WITH ALL OF THE
 FOLLOWING, EXCEPT
 AS OTHERWISE PERMITTED BY 38.2.4.2 THROUGH 38.2.4.6:
 (1) THE NUMBER OF MEANS OF EGRESS SHALL BE IN
 ACCORDANCE WITH
 SECTION 7.4.
 (2) NOT LESS THAN TWO SEPARATE EXITS SHALL BE PROVIDED
 ON EVERY STORY.
 (3) NOT LESS THAN TWO SEPARATE EXITS SHALL BE
 ACCESSIBLE FROM EVERY
 PART OF EVERY STORY.
 38.2.4.2 EXIT ACCESS, AS REQUIRED BY 38.2.4.1(3), SHALL
 BE PERMITTED TO
 INCLUDE A SINGLE EXIT ACCESS PATH FOR THE DISTANCES
 PERMITTED AS COMMON
 PATHS OF TRAVEL BY 38.2.5.3.
 38.2.4.3 A SINGLE EXIT SHALL BE PERMITTED FOR A ROOM OR
 AREA WITH A TOTAL
 OCCUPANT LOAD OF LESS THAN 100 PERSONS, PROVIDED THAT
 ALL OF THE
 FOLLOWING CRITERIA ARE MET:
 (1) THE EXIT SHALL DISCHARGE DIRECTLY TO THE OUTSIDE AT
 THE LEVEL OF EXIT
 DISCHARGE FOR THE BUILDING.
 (2) THE TOTAL DISTANCE OF TRAVEL FROM ANY POINT,
 INCLUDING TRAVEL WITHIN
 THE EXIT, SHALL NOT EXCEED 100 FT (30 M).
 (3) THE TOTAL DISTANCE OF TRAVEL SPECIFIED IN
 38.2.4.3(2) SHALL BE ON THE
 SAME STORY, OR, IF TRAVERSING OF STAIRS IS NECESSARY,
 SUCH STAIRS SHALL
 NOT EXCEED 15 FT (4570 MM) IN HEIGHT, AND BOTH OF THE
 FOLLOWING
 ALSO SHALL APPLY:
 (A) INTERIOR STAIRS SHALL BE PROVIDED WITH COMPLETE
 ENCLOSURES TO
 SEPARATE THEM FROM ANY OTHER PART OF THE BUILDING, WITH
 NO
 DOOR OPENINGS THEREIN.
 (B) A SINGLE OUTSIDE STAIR IN ACCORDANCE WITH 7.2.2
 SHALL BE
 PERMITTED TO SERVE ALL STORIES PERMITTED WITHIN THE 15
 FT (4570
 MM) VERTICAL TRAVEL LIMITATION.
  
 **********************OR**********************
  
 38.2.4.4 ANY BUSINESS OCCUPANCY THREE OR FEWER STORIES
 IN HEIGHT, AND
 NOT EXCEEDING AN OCCUPANT LOAD OF 30 PEOPLE PER STORY,
 SHALL BE
 PERMITTED A SINGLE SEPARATE EXIT TO EACH STORY,
 PROVIDED THAT ALL OF THE
 FOLLOWING CRITERIA ARE MET:
 (1) THE EXIT SHALL DISCHARGE DIRECTLY TO THE OUTSIDE.
 (2) THE TOTAL TRAVEL DISTANCE TO THE OUTSIDE OF THE
 BUILDING SHALL NOT
 EXCEED 100 FT (30 M).
 (3) THE EXIT SHALL BE ENCLOSED IN ACCORDANCE WITH
 7.1.3.2, AND BOTH OF
 THE FOLLOWING ALSO SHALL APPLY:
 (A) THE STAIR SHALL SERVE AS AN EXIT FROM NO OTHER
 STORIES.
 (B) A SINGLE OUTSIDE STAIR IN ACCORDANCE WITH 7.2.2
 SHALL BE
 PERMITTED TO SERVICE ALL STORIES.
  
 PLEASE REVIEW AND CORRECT OR JUSTIFY WITH SPECIFIC CODE
 REFERENCES AND NARRATIVE.
  
  
  
  
 3) SHEET A 602 - DOOR 117A IS NOT INDICATED AS HAVING A
 FIRE RATING. THIS DOOR IS REQUIRED TO BE RATED TO
 MAINTAIN THE 2 HR OCCUPANCY SEPARATION.
  
 PLEASE REVIEW AND CORRECT OR JUSTIFY WITH SPECIFIC CODE
 REFERENCES AND NARRATIVE.
  
  
  
 4) SHEETS A 101, 102 & 501 - THERE ARE NO INDICATIONS
 OF ANY FIRE RATINGSOF LISTINGS ON ANY OF THE WALLS OR
 CALL OUTS WHERE FIRE RATING IS REQUIRED.
  
 PLEASE REVIEW AND CORRECT OR JUSTIFY WITH SPECIFIC CODE
 REFERENCES AND NARRATIVE.
  
  
  
 5) SHEET A 101 & 602 - DOOR 118 IS NOT INDICATED AS
 HAVING A FIRE RATING. THIS DOOR IS REQUIRED TO BE RATED
 TO MAINTAIN THE 2 HR OCCUPANCY SEPARATION.
  
 PLEASE REVIEW AND CORRECT OR JUSTIFY WITH SPECIFIC CODE
 REFERENCES AND NARRATIVE.
  
  
  
  
 6) SHEET A 101 - THE IS AN AREA/ROOM IN THE MIDDLE OF
 THE 1ST FLOOR INDICATED AS ELEVATOR LOBBY & HALL.
  
 THIS AREA DOES NOT APPEAR EITHER A ELEVATOR LOBBY NOR
 HALL AND IS LABLED DIFFERENTLY THAN ON SHEET G 101.
  
 PLEASE REVIEW AND CLARIFY/CORRECT.
  
  
  
 7) SHEET A 101 & 602 - WINDOW DIAMOND 9 IS INDICATED AS
 A ROLL DOWN FIRE CURTAIN.
  
  
  
  
 8) SHEET A 102 - THE 2ND FLOOR WALL ALONG THE OPEN
 SHOWROOM IS NOT INDICATED AS HAVING A FIRE RATING.
  
 IS THIS A RATED WALL? IT HAS FIRE DROP DOWN DOORS
 INDICATED.
  
 PLEASE CLARIFY AND PROVIDE A APPLICABLE LISTED WALL
 CALLOUT.
  
  
  
 9) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
  
 10) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2019-12-09 Cont ID  
Sent By shill Date 2019-12-09 Time 17:58 Rev Time 0.00
Received By shill Date 2019-11-22 Time 14:57 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-11-08 Cont ID  
Sent By jgomez Date 2019-11-08 Time 16:56 Rev Time 0.00
Received By jgomez Date 2019-10-09 Time 11:06 Sent To  
Notes
2019-10-29 06:13:15****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 1. FBC 107, THIRD FAILED PLUMBING REVIEW. PLEASE
 CONTACT ME PRIOR TO RESUBMITTING SO A PRE-SCREEN OR
 MEETING CAN BE DONE.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-08-21 Cont ID  
Sent By rmcdouga Date 2019-08-21 Time 16:04 Rev Time 0.00
Received By rmcdouga Date 2019-07-17 Time 09:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2019-05-30 Time   Rev Time 0.00
Received By cpuell Date 2019-04-11 Time 11:12 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status P Date 2020-01-06 Cont ID  
Sent By lmarchan Date 2020-01-06 Time 16:27 Rev Time 0.00
Received By lmarchan Date 2019-12-12 Time 09:14 Sent To  
Notes
2020-01-06 16:27:51RECEIPT 2020-0106-120 - $2419.63 - PAID
2019-12-12 09:15:0012/12/19 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2019-12-09 Cont ID  
Sent By jgomez Date 2019-12-09 Time 14:51 Rev Time 0.00
Received By jgomez Date 2019-12-09 Time 14:51 Sent To  
Notes
2019-12-09 14:53:00IMPACT FEES - DIGITAL SUBMITTALS:
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
 PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300
 N. JOG RD. ROOM?S 2W01-2W14 WEST PALM BEACH, FL.
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-05-30 Cont ID  
Sent By jwitmer Date 2019-05-30 Time 08:51 Rev Time 0.00
Received By jwitmer Date 2019-05-28 Time 13:03 Sent To  
Notes
2019-05-30 08:51:53IMPACT FEES - DIGITAL SUBMITTALS:
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO
 YOUR PROJECT OR EMAIL IT TO [email protected] .
 PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300
 N. JOG RD. ROOM?S 2W01-2W14 WEST PALM BEACH, FL.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2019-12-05 Cont ID  
Sent By ccole Date 2019-12-05 Time 10:22 Rev Time 0.00
Received By ccole Date 2019-12-03 Time 15:20 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2019-10-28 Cont ID  
Sent By ccole Date 2019-10-28 Time 14:06 Rev Time 0.00
Received By ccole Date 2019-10-24 Time 15:31 Sent To  
Notes
2019-10-28 14:08:562ND REVIEW FBC-2017 MECHANICAL
 PERMIT #19040448
 10/28/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 PLEASE PROVIDE CORRECTED PLANS AND A NARRATIVE RESPONSE
 TO THE COMMENTS LISTED BELOW THAT ARE REMAINING FROM
 THE 1ST REVIEW- SECTION 107.2.1 WPB. THE NARRATIVE MUST
 BE PROVIDED BY THE DESIGN PROFESSIONAL OF RECORD FOR
 THE PROJECT.
  
 1) COMMISSIONING OF THE MECHANICAL AND SERVICE WATER
 HEATING SYSTEMS IS REQUIRED PER SECTION C408.2 FBC-17
 ENERGY CONSERVATION. SUBMIT A COMMISSIONING PLAN AS
 OUTLINED IN SECTION C408.2.1 AND DESCRIBED IN SECTIONS
 C403.2.2- C408.2.3.3. PLEASE NOTE THAT A COPY OF THE
 COMMISSIONING REPORT SHALL BE SUBMITTED FOR REVIEW AT
 FINAL INSPECTION.
  
 2) CLARIFY IF THE FLAMINGO EXHAUST SYSTEM WILL BE
 INSTALLED UNDER A SEPARATE PERMIT. CURRENTLY THERE ARE
 NO PLANS AND SPECIFICATIONS SUBMITTED EXCEPT FOR THE
 EXHAUST FAN- SECTION 107.2.1 WPB.
  
 5) M2.1 RECIRCULATION OF AIR FROM THE SERVICE ROOM INTO
 THE LOCKER ROOM IS PROHIBITED PER TABLE 403.3.1.1
 FOOTNOTE B.
  
 6) M2.1 & M2.2: AUTOMATICALLY CONTROLLED SHUTOFF
 DAMPERS ARE REQUIRED FOR THE O/A DUCTS AT EACH AIR
 HANDLER LOCATION - SECTION C403.2.4.3 FBC EC.
  
 7) M2.1 & M2.2: PLEASE SHOW THE FLEX DUCT SIZES-
 SECTION 603.2 FBC M.
  
 9) M2.2 & M2.3: PROVIDE CLEARANCE DISTANCE MEASUREMENTS
 FOR MECHANICAL AND GRAVITY AIR INTAKES TO EXHAUST AIR
 OUTLETS- SECTION 401.4 FBC M.
  
 10) M2.2, M2.3, & M7.1: PROVIDE COMPLETE WIND LOAD
 ENGINEERING FOR INSTALLATION OF THE RTU'S, ROOFTOP
 CONDENSERS AND STANDS, ROOFTOP FANS AND CURBS, AND
 GRAVITY VENTILATORS. PLEASE INCLUDE THE DESIGN
 CRITERIA- SECTION 1609 FBC B, AND SECTION 301.15 FBC M,
 AND FL. PRODUCT APPROVALS AND/OR MIAMI-DADE NOA'S FOR
 AC ROOF STANDS AND FAN CURBS.
  
 12) PROVIDE INSTALLATION DETAILS FOR THE CIRCULATION
 FANS IN THE SERVICE AND SERVICE RECEPTION AREAS-
 SECTION 107.2.1 WPB, AND SECTION 304.1 FBC M.
  
 13) EMERGENCY GENERATOR: A) SHOW THE LOCATION ON THE
 MECHANICAL PLANS WITH ALL REQUIRED CLEARANCE DISTANCE
 MEASUREMENTS. B) SUBMIT MANUFACTURER'S SPECIFICATIONS
 FOR THE GENERATOR, EXHAUST AND FUEL OIL PIPING. C)
 SUBMIT THE UL 2200 CERTIFICATE FOR THE GENERATOR. D)
 PROVIDE AN ENLARGED DRAWING SHOWING THE EXHAUST FLUE
 RUN AND TERMINATION LOCATION, AND THE FUEL OIL PIPING
 RUN AND SOURCE LOCATION. E) PROVIDE WIND LOAD
 ENGINEERING FOR INSTALLATION OF THE GENERATOR AND ALL
 ASSOCIATED EXTERIOR EQUIPMENT- SECTION 301.15 FBC M.
 REFERENCES: SECTION 915.1 FBC M, SECTIONS 4.1, 6.1, &
 8.1 NFPA 37, SECTION 4.1 NFPA 110.
  
 14) PLEASE PROVIDE AN ENLARGED COMPRESSOR ROOM PLAN AND
 EQUIPMENT SCHEDULE. IT APPEARS THAT FUEL OIL TANKS WILL
 BE INSTALLED IN THE ROOM WHICH REQUIRES THE ROOM, THE
 TANK INSTALLATION, AND VENTILATION SYSTEM TO BE IN
 COMPLIANCE WITH NFPA 30. A) PLEASE SUBMIT
 MANUFACTURER?S SPECIFICATIONS FOR THE TANKS. B) PROVIDE
 THE CLASSIFICATION OF THE FUEL AND SUBMIT AN MSDS
 SHEET- SECTION 4.3.1. C) PROVIDE EXHAUST VENTILATION
 CALCULATIONS FOR EF-4 AND INDICATE THE SEQUENCE OF
 OPERATION- SECTION 24.10.1 NFPA 30, AND SECTION 510.2
 FBC M.
  
 15) REQUIRED SUBMITTALS LISTED BELOW SHALL BE PROVIDED
 WITH THE CORRECTED PLANS OR MAY BE DEFERRED BY REQUEST.
 ALL SUBMITTALS SHALL BEAR THE SHOP DRAWING APPROVAL
 STAMP BY THE ENGINEER OF RECORD.
  
 1) SIGNED AND SEALED STRUCTURAL ENGINEERING FOR
 INSTALLATION OF ALL EXTERIOR MECHANICAL EQUIPMENT (AS
 NOTED ABOVE IN COMMENT #10).
 2) C0, N02, CO2, FV SENSORS AND CONTROLLERS.
 3) MOTORIZED DAMPERS.
 4) DUCT SMOKE DETECTORS.
 5) FIRE DAMPERS
 6) GENERATOR
 7) FUEL OIL TANKS
 8) AIR COMPRESSOR
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2019-08-20 Cont ID  
Sent By cmontell Date 2019-08-20 Time 13:35 Rev Time 0.00
Received By cmontell Date 2019-08-19 Time 14:53 Sent To  
Notes
2019-08-19 14:52:202ND MECHANICAL REVIEW FAIL
  
 1) M2.1 & M2.2: AUTOMATICALLY CONTROLLED SHUTOFF
 DAMPERS ARE REQUIRED FOR THE O/A DUCTS AT EACH AIR
 HANDLER LOCATION - SECTION C403.2.4.3 FBC EC.
  
 2) M2.1 & M2.2: PLEASE SHOW THE FLEX DUCT SIZES-
 SECTION 603.2 FBC M.
  
 3) PROVIDE CONDENSATE DISPOSAL PLANS FOR THE AC SYSTEMS
 INCLUDING TYPE AND SIZES OF CONDENSATE PIPING, PIPING
 RUNS, PIPING SUPPORTS INSIDE AND ABOVE THE ROOF, AND
 DISCHARGE LOCATIONS- SEE SECTION 307.2 FBC M.
  
 4) PLEASE PROVIDE AN ENLARGED COMPRESSOR ROOM PLAN AND
 EQUIPMENT SCHEDULE. IT APPEARS THAT FUEL OIL TANKS WILL
 BE INSTALLED IN THE ROOM WHICH REQUIRES THE ROOM, THE
 TANK INSTALLATION, AND VENTILATION SYSTEM TO BE IN
 COMPLIANCE WITH NFPA 30. A) PLEASE SUBMIT
 MANUFACTURER?S SPECIFICATIONS FOR THE TANKS. B) PROVIDE
 THE CLASSIFICATION OF THE FUEL AND SUBMIT AN MSDS
 SHEET- SECTION 4.3.1. C) PROVIDE EXHAUST VENTILATION
 CALCULATIONS FOR EF-4 AND INDICATE THE SEQUENCE OF
 OPERATION- SECTION 24.10.1 NFPA 30, AND SECTION 510.2
 FBC M.
  
 5) REQUIRED SUBMITTALS LISTED BELOW SHALL BE PROVIDED
 WITH THE CORRECTED PLANS OR MAY BE DEFERRED BY REQUEST.
 ALL SUBMITTALS SHALL BEAR THE SHOP DRAWING APPROVAL
 STAMP BY THE ENGINEER OF RECORD.
  
 1) SIGNED AND SEALED STRUCTURAL ENGINEERING FOR
 INSTALLATION OF ALL EXTERIOR MECHANICAL EQUIPMENT (AS
 NOTED ABOVE IN COMMENT #10).
 2) C0, N02, CO2, FV SENSORS AND CONTROLLERS.
 3) MOTORIZED DAMPERS.
 4) DUCT SMOKE DETECTORS.
 5) FIRE DAMPERS
 6) GENERATOR
 7) FUEL OIL TANKS
 8) AIR COMPRESSOR
  
 ALL COMMENTS FROM PREVIOUS PLAN REVIEW
  
 CHRIS MONTELLO
 561-805-6733
  
  
  
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-05-10 Cont ID  
Sent By ccole Date 2019-05-10 Time 09:37 Rev Time 0.00
Received By ccole Date 2019-05-09 Time 13:12 Sent To  
Notes
2019-05-10 09:37:491ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19040448
 5/10/19
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) COMMISSIONING OF THE MECHANICAL AND SERVICE WATER
 HEATING SYSTEMS IS REQUIRED PER SECTION C408.2 FBC-17
 ENERGY CONSERVATION. SUBMIT A COMMISSIONING PLAN AS
 OUTLINED IN SECTION C408.2.1 AND DESCRIBED IN SECTIONS
 C403.2.2- C408.2.3.3. PLEASE NOTE THAT A COPY OF THE
 COMMISSIONING REPORT SHALL BE SUBMITTED FOR REVIEW AT
 FINAL INSPECTION.
  
 2) CLARIFY IF THE FLAMINGO EXHAUST SYSTEM WILL BE
 INSTALLED UNDER A SEPARATE PERMIT. CURRENTLY THERE ARE
 NO PLANS AND SPECIFICATIONS SUBMITTED EXCEPT FOR THE
 EXHAUST FAN- SECTION 107.2.1 WPB.
  
 3) SHEET M2.1: AN EXHAUST VENTILATION SYSTEM IS
 REQUIRED FOR THE CAR SERVICE RECEPTION ROOM IN
 COMPLIANCE WITH TABLE 403.3.1.1 AND SECTION 404 FBC M.
 THE ROOM HAVING AN OPENING ON ONLY ONE SIDE DOES NOT
 MEET THE REQUIREMENT OF HAVING OPENINGS ON TWO OR MORE
 SIDES- SEE SECTIONS 406.5, 406.5.2, AND 406.6 FBC B AND
 REVISE THE PLANS AND EXHAUST CALCULATIONS IN THE TABLE
 ON SHEET M0.1:
  
 4) SHEET M2.1 & M2.2: AN EXHAUST VENTILATION SYSTEM IS
 REQUIRED FOR THE CAR SHOWROOM IN COMPLIANCE WITH TABLE
 403.3.1.1 AND SECTION 404 FBC M. ALTHOUGH THE SHOWROOM
 IS CLASSIFIED AS A BUSINESS OCCUPANCY PER SECTION 304.1
 FBC B, MOTOR VEHICLES WILL BE PARKED IN THE ROOM, AND
 THE ROOM IS OPEN TO THE PUBLIC. REVISE THE PLANS, AND
 EXHAUST CALCULATIONS IN THE TABLE ON SHEET M0.1:
  
 5) M2.1 RECIRCULATION OF AIR FROM THE SERVICE ROOM INTO
 THE LOCKER ROOM IS PROHIBITED PER TABLE 403.3.1.1
 FOOTNOTE B.
  
 6) M2.1 & M2.2: AUTOMATICALLY CONTROLLED SHUTOFF
 DAMPERS ARE REQUIRED FOR THE O/A DUCTS AT EACH AIR
 HANDLER LOCATION - SECTION C403.2.4.3 FBC EC.
  
 7) M2.1 & M2.2: PLEASE SHOW THE FLEX DUCT SIZES-
 SECTION 603.2 FBC M.
  
 8) M2.2 & M2.3: PROVIDE CLEARANCE DISTANCE MEASUREMENTS
 FOR THE RTU?S AND ROOF FANS TO THE ROOF EDGES- SECTION
 304.11 FBC M.
  
 9) M2.2 & M2.3: PROVIDE CLEARANCE DISTANCE MEASUREMENTS
 FOR MECHANICAL AND GRAVITY AIR INTAKES TO EXHAUST AIR
 OUTLETS- SECTION 401.4 FBC M.
  
 10) M2.2, M2.3, & M7.1: PROVIDE COMPLETE WIND LOAD
 ENGINEERING FOR INSTALLATION OF THE RTU'S, ROOFTOP
 CONDENSERS AND STANDS, ROOFTOP FANS AND CURBS, AND
 GRAVITY VENTILATORS. PLEASE INCLUDE THE DESIGN
 CRITERIA- SECTION 1609 FBC B, AND SECTION 301.15 FBC M,
 AND FL. PRODUCT APPROVALS AND/OR MIAMI-DADE NOA'S FOR
 AC ROOF STANDS AND FAN CURBS.
  
 11) PROVIDE CONDENSATE DISPOSAL PLANS FOR THE AC
 SYSTEMS INCLUDING TYPE AND SIZES OF CONDENSATE PIPING,
 PIPING RUNS, PIPING SUPPORTS INSIDE AND ABOVE THE ROOF,
 AND DISCHARGE LOCATIONS- SEE SECTION 307.2 FBC M.
  
 12) PROVIDE INSTALLATION DETAILS FOR THE CIRCULATION
 FANS IN THE SERVICE AND SERVICE RECEPTION AREAS-
 SECTION 107.2.1 WPB, AND SECTION 304.1 FBC M.
  
 13) EMERGENCY GENERATOR: A) SHOW THE LOCATION ON THE
 MECHANICAL PLANS WITH ALL REQUIRED CLEARANCE DISTANCE
 MEASUREMENTS. B) SUBMIT MANUFACTURER'S SPECIFICATIONS
 FOR THE GENERATOR, EXHAUST AND FUEL OIL PIPING. C)
 SUBMIT THE UL 2200 CERTIFICATE FOR THE GENERATOR. D)
 PROVIDE AN ENLARGED DRAWING SHOWING THE EXHAUST FLUE
 RUN AND TERMINATION LOCATION, AND THE FUEL OIL PIPING
 RUN AND SOURCE LOCATION. E) PROVIDE WIND LOAD
 ENGINEERING FOR INSTALLATION OF THE GENERATOR AND ALL
 ASSOCIATED EXTERIOR EQUIPMENT- SECTION 301.15 FBC M.
 REFERENCES: SECTION 915.1 FBC M, SECTIONS 4.1, 6.1, &
 8.1 NFPA 37, SECTION 4.1 NFPA 110.
  
 14) PLEASE PROVIDE AN ENLARGED COMPRESSOR ROOM PLAN AND
 EQUIPMENT SCHEDULE. IT APPEARS THAT FUEL OIL TANKS WILL
 BE INSTALLED IN THE ROOM WHICH REQUIRES THE ROOM, THE
 TANK INSTALLATION, AND VENTILATION SYSTEM TO BE IN
 COMPLIANCE WITH NFPA 30. A) PLEASE SUBMIT
 MANUFACTURER?S SPECIFICATIONS FOR THE TANKS. B) PROVIDE
 THE CLASSIFICATION OF THE FUEL AND SUBMIT AN MSDS
 SHEET- SECTION 4.3.1. C) PROVIDE EXHAUST VENTILATION
 CALCULATIONS FOR EF-4 AND INDICATE THE SEQUENCE OF
 OPERATION- SECTION 24.10.1 NFPA 30, AND SECTION 510.2
 FBC M.
  
 15) REQUIRED SUBMITTALS LISTED BELOW SHALL BE PROVIDED
 WITH THE CORRECTED PLANS OR MAY BE DEFERRED BY REQUEST.
 ALL SUBMITTALS SHALL BEAR THE SHOP DRAWING APPROVAL
 STAMP BY THE ENGINEER OF RECORD.
  
 1) SIGNED AND SEALED STRUCTURAL ENGINEERING FOR
 INSTALLATION OF ALL EXTERIOR MECHANICAL EQUIPMENT (AS
 NOTED ABOVE IN COMMENT #10).
 2) C0, N02, CO2, FV SENSORS AND CONTROLLERS.
 3) MOTORIZED DAMPERS.
 4) DUCT SMOKE DETECTORS.
 5) FIRE DAMPERS
 6) GENERATOR
 7) FUEL OIL TANKS
 8) AIR COMPRESSOR
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  
  
  
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2019-12-09 Cont ID  
Sent By shill Date 2019-12-09 Time 17:57 Rev Time 0.00
Received By shill Date 2019-12-09 Time 12:59 Sent To  
Notes
2019-12-09 17:57:58REVIEWED REMOTELY BY TIM HUNT
  

Review Stop P PLUMBING
Rev No 3 Status F Date 2019-10-29 Cont ID  
Sent By shill Date 2019-10-29 Time 06:04 Rev Time 0.00
Received By shill Date 2019-10-25 Time 13:03 Sent To  
Notes
2019-10-29 06:04:34PLUMBING 3RD REVIEW**DENIED**PLEASE SUPPLIED A
 NARRATIVE. FL STATUE 553.80 (2) (B) WITH RESPECT TO
 EVALUATION OF DESIGN PROFESSIONALS? DOCUMENTS, IF A
 LOCAL GOVERNMENT FINDS IT NECESSARY, IN ORDER TO
 ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING CODE AND
 ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS REQUIRED BY
 THE CODE THREE OR MORE TIMES FOR FAILURE TO CORRECT A
 CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY NOTED IN
 EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, EGRESS,
 FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
 LAST REVIEW COMMENTS STILL NOT ANSWERED AGAIN.
 1-PROVIDE CLEAR FLOOR SPACE AND TURNING SPACE FOR THE
 TRAINING ROOM/ BREAK ROOM SINK WITH CABINET DETAIL
 SHOWING MAX 34?. FBC-ACC 606.2, 606.3
 2- PROVIDE NOTE ON PLAN SEPARATE BACKFLOW AND
 INTERCEPTOR PERMIT REQUIRED. FBC 107.1
 3-SHT. A-106 IS CALLING OUT ROOF DRAIN CALCULATIONS
 BASED ON 2010 FBC-PLB CODE. THE CODE CURRENTLY IS THE
 2017 6TH ED. PLEASE CORRECT AND SHOW THE CORRECT CODE.
 PROVIDE SIZING OF THE STORM SYSTEM PER FBC-PLB 1105.2,
 1106.2
 4- SHT. A-106 CALL OUT PIPE PITCHED PER FBC-PLB 553.10.
 PLEASE CLARIFY. FBC 107.1
 5-SHT. A-301 SHOWS ROOF PITCH AS 1/4? PER FOOT BUT
 DRAIN DETAIL CALLS OUT ?? PER FOOT. PLEASE CLARIFY. FBC
 107.1
 6-SHT. A-401 MIRROR DETAIL SHOWS MOUNTING AT 3?4? (40?)
 TO THE BOTTOM OF THE MIRROR. MAX MEASUREMENT SHALL BE
 TO THE REFLECTING SURFACE. FBC-ACC 603.3
 TIM HUNT
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 THUNT@CGASOLUTIONS
 561-248-2703
  
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2019-08-21 Cont ID  
Sent By rmcdouga Date 2019-08-21 Time 16:03 Rev Time 0.00
Received By rmcdouga Date 2019-08-09 Time 12:29 Sent To  
Notes
2019-08-21 16:03:44PLUMBING 2ND REVIEW**DENIED**
 LAST REVIEW COMMENTS STILL NOT ANSWERED
 1-PROVIDE CLEAR FLOOR SPACE AND TURNING SPACE FOR THE
 TRAINING ROOM/ BREAK ROOM SINK WITH CABINET DETAIL
 SHOWING MAX 34?. FBC-ACC 606.2, 606.3
 2- PROVIDE NOTE ON PLAN SEPARATE BACKFLOW AND
 INTERCEPTOR PERMIT REQUIRED. FBC 107.1
 3-SHT. A-106 IS CALLING OUT ROOF DRAIN CALCULATIONS
 BASED ON 2010 FBC-PLB CODE. THE CODE CURRENTLY IS THE
 2017 6TH ED. PROVIDE SIZING OF THE STORM SYSTEM PER
 FBC-PLB 1105.2, 1106.2
 4- SHT. A-106 CALL OUT PIPE PITCHED PER FBC-PLB 553.10.
 PLEASE CLARIFY. FBC 107.1
 5-SHT. A-301 SHOWS ROOF PITCH AS 1/4? PER FOOT BUT
 DRAIN DETAIL CALLS OUT ?? PER FOOT. PLEASE CLARIFY. FBC
 107.1
 6-SHT. A-401 MIRROR DETAIL SHOWS MOUNTING AT 3?4? (40?)
 TO THE BOTTOM OF THE MIRROR. MAX MEASUREMENT SHALL BE
 TO THE REFLECTING SURFACE. FBC-ACC 603.3
 TIM HUNT
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 THUNT@CGASOLUTIONS
 561-248-2703
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-05-06 Cont ID  
Sent By thunt Date 2019-05-06 Time 14:31 Rev Time 0.00
Received By thunt Date 2019-05-06 Time 10:27 Sent To  
Notes
2019-05-06 14:32:34PLUMBING 1ST REVIEW**DENIED**
  
 1) PROVIDE OCCUPANT LOAD FOR EACH OCCUPANCY. FBC
 107.3.5
  
 2) SHT. G-101 PLUMBING FIXTURE LIST JANITOR SINKS AS
 (0). PLEASE ADVISED AS FLOOR PLANS SHOWS 2 BEING
 INSTALLED AS REQUIRED IN FBC-P TABLE 403.1
  
 3) TOILET ROOMS 111 AND 209 SHOWS THE CLEAR FLOOR
 SPACES BACKWARDS. PLEASE CORRECT. FBC-ACC 604.3.1,
 606.2
  
 4) PROVIDE CLEAR FLOOR SPACE FOR BOTH DRINKING
 FOUNTAINS ON SHT. A-102, A-104. FBC-ACC 602.2
  
 5) PROVIDE CLEAR FLOOR SPACE AND CABINET HEIGHT DETAIL
 SHOWING MAX HEIGHT TO BE 34" FOR THE BREAK ROOM/
 TRAINING ROOM. FBC-ACC 606.2
  
 6) SHT. A-106 PROVIDE LOCATION ON PLAN SHOWING ROOF
 DRAINS LOCATIONS. FBC 107.2.1
  
 7) SHT. A 401 DOES NOT SHOW ADA GRAB BAR MOUNTING
 HEIGHT. PROVIDE DETAIL SHOWING THAT BAR WILL BE MOUNTED
 33" TO 36" TO THE TOP OF GRIPPING SURFACE. FBC-ACC
 609.4
  
 8) PROVIDE INSTALLATION MANUAL FOR THE OIL/SAND
 INTERCEPTOR SHOWING IT IS LISTED AND LABELED. FBC-P
 1003.4.2
  
 9) PROVIDE CALCULATIONS FOR HOW YOU DETERMINED
 INTERCEPTOR SIZE. FBC-P 1003.4.2.2
  
 10) XA RECESS SUMP PUMP SHALL INDIRECTLY DISCHARGE IN
 TO THE SAND/ OIL INTERCEPTOR. FBC-P 1003.1
  
 11) PROVIDE NOTED ON PLAN THAT BACKFLOWS AND
 INTERCEPTORS REQUIRED THERE OWN SEPERATE PLUMBING
 PERMIT.
  
  
  
 TIM HUNT
 PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 561-248-2703
 [email protected]
 [email protected]
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status P Date 2019-12-02 Cont ID  
Sent By jgomez Date 2019-12-02 Time 14:56 Rev Time 0.00
Received By jgomez Date 2019-12-02 Time 14:56 Sent To  
Notes
2019-12-02 14:57:01PROVISO:
  
 1- PROVIDE ROOFING PRODUCT APPROVAL AND CLEARLY MARK
 ASSEMBLY TO BE INSTALLED.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status F Date 2019-11-08 Cont ID  
Sent By jgomez Date 2019-11-08 Time 16:59 Rev Time 0.00
Received By jgomez Date 2019-11-07 Time 07:55 Sent To  
Notes
2019-11-08 17:00:22SEE ITEM #6 ON 3RD BUILDING REVIEW DONE BY JULIO GOMEZ.
  
  
 ORIGINAL COMMENT:
 3RD REQUEST. THE SUBMITTED NOA: 14-0827.18TAMKO
 MODIFIED BITUMEN ROOF SYSTEM OVER STEEL DECK HAS
 VARIOUS SUB-SYSTEMS LISTED WITHIN THE REPORT BUT NONE
 OF THE SUB-SYSTEMS WERE IDENTIFIED AS THE ONE BEING
 INSTALLED. : FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY
 ALL ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES
 FOR ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL
 LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED
 (LIMITATION #7 ALLOWS ENHANCED FASTENING, LIMITATION #
 9 DOES NOT ALLOW ENHANCED FASTENING) FOR ROOF ZONES 2 &
 3. FASTENER DENSITIES SHALL BE INCREASED FOR BOTH
 INSULATION & THE BASE SHEET AS CALCULATED IN COMPLIANCE
 WITH ROOFING APPLICATION STANDARDS RAS 117. CALCULATION
 PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED
 PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT.
 1609.6.4.4.1 COMPONENTS & CLADDING.
  
 RESPONSE:
 APPROVED ASSEMBLY WAS NOT SELECTED. AND, NEED SIGNED
 AND SEALED RAS 117 CALCULATIONS FOR SELECTED ASSEMBLY
 (GENERAL LIMITATION #7 ONLY). IF THE SELECTED ASSEMBLY
 IS LIMITED BY GENERAL LIMITATION #9 AND THE ASSEMBLY
 DOESN'T MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES,
 THEN IT CAN NOT BE USED.
 NOTE: ALL PRODUCT APPROVALS CAN BE SUBMITTED LATER AS
 DEFERRED SUBMITTAL. ADVICE IF PREFER TO SUBMIT PRODUCT
 APPROVALS AS DEFERRED SUBMITTAL.

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2019-08-12 Cont ID  
Sent By jwitmer Date 2019-08-12 Time 11:54 Rev Time 0.00
Received By jwitmer Date 2019-08-12 Time 07:54 Sent To  
Notes
2019-08-12 11:53:581) 2ND REQUEST. THE SUBMITTED NOA: 14-0827.18TAMKO
 MODIFIED BITUMEN ROOF SYSTEM OVER STEEL DECK HAS
 VARIOUS SUB-SYSTEMS LISTED WITHIN THE REPORT BUT NONE
 OF THE SUB-SYSTEMS WERE IDENTIFIED AS THE ONE BEING
 INSTALLED. : FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY
 ALL ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES
 FOR ROOF ZONE # 1. REVIEW THE PRODUCT APPROVAL
 LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED
 (LIMITATION #7 ALLOWS ENHANCED FASTENING, LIMITATION #
 9 DOES NOT ALLOW ENHANCED FASTENING) FOR ROOF ZONES 2 &
 3. FASTENER DENSITIES SHALL BE INCREASED FOR BOTH
 INSULATION & THE BASE SHEET AS CALCULATED IN COMPLIANCE
 WITH ROOFING APPLICATION STANDARDS RAS 117. CALCULATION
 PREPARED, SIGNED AND SEALED BY A FLORIDA REGISTERED
 PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT.
 1609.6.4.4.1 COMPONENTS & CLADDING.
  
 2) 2ND REQUEST. THE SUBMITTAL NOA: 16-0219.01 TC-5
 SERIES STEEL ROOF CURB FOR TRANE ROOF TOP UNITS. PLEASE
 REVIEW SHEET 4 AND 5 OF THE PRODUCT APPROVAL FOR
 TECHNICAL NOTES. RESTRAINT BRACKET QUANTITY IS
 DETERMINED BY PROJECT SPECIFIC CALCULATIONS, PERFORMED
 BY A FLORIDA LICENSED PE OR FLORIDA REGISTERED
 ARCHITECT THAT CONSIDER THE UNIQUE COMBINATION OF THE
 UNIT SIZE AND APPLICABLE LATERAL AND UPLIFT PRESSURES
 FOR EACH JOB. PLEASE PROVIDE CALCULATION FOR HOW MANY
 BRACKETS WILL BE NEEDED FOR EACH TYPE OF UNIT.
 107.2.1.3. ADDITIONAL INFORMATION IS REQUIRED. 2017
 FBC-M- 301.15 WIND RESISTANCE. MECHANICAL EQUIPMENT,
 APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO WIND SHALL
 BE DESIGNED AND INSTALLED TO RESIST THE WIND PRESSURES
 DETERMINED IN ACCORDANCE WITH THE FLORIDA BUILDING
 CODE, BUILDING.
  
 3) 2ND REQUEST. THERE MUST BE A PERMANENT MEANS OF
 EGRESS TO REACH THE ROOF TOP HATCH.
 1ST ROUND OF COMMENTS. SHEET 042-A102 THE 2ND FLOOR
 PLAN AND ROOF PLAN OF THE REPAIR GARAGE, SHOWS A ROOF
 HATCH TO GAIN ACCESS TO THE MECHANICAL EQUIPMENT ON THE
 ROOF. SHEET 047-A-301 SHOWS A VERTICAL DISTANCE FROM
 THE FINISH FLOOR TO THE BOTTOM OF THE BAR JOIST OF
 14.66 FEET, CENTERED IN THE SERVICE BAY DOORWAY. THE
 VERTICAL DISTANCE FROM FINISH FLOOR TO THE TOP OF THE
 ROOF AT THE ROOF HATCH IS OVER 18.50 FEET. PLEASE SHOW
 HOW COMPLIANCE WITH 306.5 OF THE 2017 MECHANICAL CODE
 WILL BE MET:
 2017 FBC-MECHANICAL. 306.5 EQUIPMENT AND APPLIANCES ON
 ROOFS OR ELEVATED STRUCTURES.
 WHERE EQUIPMENT REQUIRING ACCESS OR APPLIANCES ARE
 LOCATED ON AN ELEVATED STRUCTURE OR THE ROOF OF A
 BUILDING SUCH THAT PERSONNEL WILL HAVE TO CLIMB HIGHER
 THAN 16 FEET (4877 MM) ABOVE GRADE TO ACCESS SUCH
 EQUIPMENT OR APPLIANCES, AN INTERIOR OR EXTERIOR MEANS
 OF ACCESS SHALL BE PROVIDED. SUCH ACCESS SHALL NOT
 REQUIRE CLIMBING OVER OBSTRUCTIONS GREATER THAN 30
 INCHES (762 MM) IN HEIGHT.
  
 4) 2ND REQUEST. PLEASE ALSO PROVIDE CODE COMPLIANCE
 WITH: 2017 FBC-B ROOF HATCH EXCEPTION: IN BUILDINGS
 WITHOUT AN OCCUPIED ROOF, ACCESS TO THE ROOF SHALL BE
 PERMITTED TO BE A ROOF HATCH OR TRAP DOOR NOT LESS THAN
 16 SQUARE FEET IN AREA AND HAVING A MINIMUM DIMENSION
 OF 2 FEET.
  
 5) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2019-05-30 Cont ID  
Sent By jwitmer Date 2019-05-30 Time 08:53 Rev Time 0.00
Received By jwitmer Date 2019-05-28 Time 13:03 Sent To  
Notes
2019-05-30 08:53:26ROOFING: THE SUBMITTED NOA: 14-0827.18TAMKO MODIFIED
 BITUMEN ROOF SYSTEM OVER STEEL DECK HAS VARIOUS
 SUB-SYSTEMS LISTED WITHIN THE REPORT BUT NONE OF THE
 SUB-SYSTEMS WERE IDENTIFIED AS THE ONE BEING INSTALLED.
 : FOR ALL ROOFING PRODUCTS PLEASE IDENTIFY ALL ROOFING
 SUB-SYSTEMS AND THEIR ASSOCIATED PRESSURES FOR ROOF
 ZONE # 1. REVIEW THE PRODUCT APPROVAL LIMITATIONS, IF
 ENHANCED FASTENING IS ALLOWED
 (LIMITATION #7 ALLOWS ENHANCED FASTENING, LIMITATION #
 9 DOESN?T) FOR ROOF ZONES 2 & 3. FASTENER DENSITIES
 SHALL BE INCREASED FOR BOTH INSULATION & THE BASE SHEET
 AS CALCULATED IN COMPLIANCE WITH ROOFING APPLICATION
 STANDARDS RAS 117. CALCULATION PREPARED, SIGNED AND
 SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR
 REGISTERED ARCHITECT. 1609.6.4.4.1 COMPONENTS &
 CLADDING.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2019-12-09 Cont ID  
Sent By shill Date 2019-12-09 Time 15:34 Rev Time 0.00
Received By shill Date 2019-12-02 Time 14:50 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2019-10-29 Cont ID  
Sent By shill Date 2019-10-29 Time 06:10 Rev Time 0.00
Received By shill Date 2019-10-29 Time 06:10 Sent To  
Notes
2019-10-15 18:07:34GEOTECH REPORT RECEIVED (PAPER)
  
2019-10-10 16:18:51GEO REPORT ROUTED TO SHILL'S DESK

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-08-09 Cont ID  
Sent By shill Date 2019-08-09 Time 17:57 Rev Time 0.00
Received By shill Date 2019-08-09 Time 17:55 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-05-02 Cont ID  
Sent By shill Date 2019-05-02 Time 17:01 Rev Time 0.00
Received By shill Date 2019-05-02 Time 15:05 Sent To  
Notes
2019-05-02 17:02:09SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 PER FLORIDA STATUTE 471, 481
  
 1. NEW PAGES SUBMITTED IN SUBSEQUENT REVIEW CYCLES
 REQUIRE VERIFICATION.
  
 2. THE ARCHITECT'S SEAL (BRIAN P. HERBERT, AR) IS
 REQUIRED. PLEASE REVISE ALL PAGES, BUT ONLY RESUBMIT
 PAGES WHICH CHANGE FOR CODE RELATED COMMENTS.
  
 SHEET 003 G-501 IS NOT DIGITALLY SIGNED. PLEASE CONFIRM
 ALL SHEETS ARE DIGITALLY SIGNED.
  
 3. SURVEY (004 V-1 BOUNDARY SURVEY) - OK
  
 4. CIVIL PAGES (ZACHARY D. TODD, PE) - SIGNATURE AND
 TITLE BLOCK ARE OK, BUT SHEET 018 14 WASTEWATER #3 IS
 NOT SIGNED (ALSO SHEET 019, 020; CHECK ALL).
  
 5. STRUCTURAL PAGES (MURRAY G. BRYNSTESEN, PE) HAS A
 SIGNATURE WHICH DOES NOT APPEAR TO MEET THE
 REQUIREMENTS OF FAC61G15-23.004 (PER EMAIL TO AND FROM
 FBPE). PLESAE CONTACT ME OR WENDY ANDERSON AT FBPE IF
 YOU WISH TO DISCUSS. TITLE BLOCK OK.
  
 6. MECHANICAL AND PLUMBING PAGES, ENERGY CALCS,
 SYSTEMPS DESIGN REPORT (MIRCEA PELLA, PE) AND
 ELECTRICAL PAGES (LON CARTER, PE) SIGNATURE AND TITLE
 BLOCK OK, BUT LACKS THE LANGUAGE REQUIRED BY
 FAC61G15-23.004 AND LACKS A SEAL (OR SIGNATURE CAN
 STATE "SIGNED AND SEALED"). PLEASE REVISE ALL BUT
 RESUBMIT ONLY PAGES WHICH CHANGE DUE TO CODE RELATED
 COMMENTS.
  

Review Stop Z ZONING
Rev No 4 Status P Date 2019-11-26 Cont ID  
Sent By llouie Date 2019-11-26 Time   Rev Time 0.00
Received By llouie Date 2019-11-26 Time   Sent To  
Notes
2019-11-26 10:36:21ZONING APPROVED WITH THE FOLLOWING PROVISOS:
  
 1.) MINOR PD AMENDMENT REQUIRED FOR THE AS-BUILT PRIOR
 TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY (C.O.).
  
 2.) SEPARATE PERMITS REQUIRED FOR: LANDSCAPING, SITE
 LIGHTING, SIGNAGE, DUMPSTER ENCLOSURE, GENERATOR,
 SECURITY GATES AND PARKING AREA.

Review Stop Z ZONING
Rev No 3 Status F Date 2019-10-18 Cont ID  
Sent By llouie Date 2019-10-18 Time   Rev Time 0.00
Received By llouie Date 2019-10-18 Time   Sent To  
Notes
2019-10-18 10:38:27** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) BUILDING SQUARE FOOTAGE DOES NOT MATCH WHAT HAD
 BEEN APPROVED THROUGH THE PLANNING PROCESS. THE
 APPROVAL IS GRANTED FOR 14,709 SQ. FT. AND NOT 15,805
 SQ. FT. AS SPECIFIED IN THE APPLICATION AND
 ARCHITECTURAL PLANS. PLEASE ADDRESS BUILDING SQUARE
 FOOTAGE IN BUILDING PERMIT SET FOR CONSISTENCY WITH THE
 APPROVED PLANS. INCREASING THE BUILDING SQUARE FOOTAGE
 MAY REQUIRE THE PROJECT TO GO BACK TO THE PUBLIC
 HEARING PROCESS.
  
 2.) MASTER DEVELOPMENT PLAN (SHEET MP-1) DOES NOT
 REFLECT THE LATEST CHANGES APPROVED. PLEASE PROVIDE THE
 CORRECT MASTER DEVELOPMENT PLAN FOR CONSISTENCY.
  
 3.) SITE PLAN (SHEET SP-1) DOES NOT REFLECT THE LATEST
 CHANGES APPROVED. PLEASE PROVIDE THE CORRECT SITE PLAN
 FOR CONSISTENCY.
  
 4.) SEPARATE PERMITS REQUIRED FOR: LANDSCAPING,
 DUMPSTER ENCLOSURE, GENERATOR, SIGNAGE, EXTERIOR
 LIGHTING, FLAG POLE.
  
 5.) CITY'S DIMENSIONAL STANDARDS HAVE CHANGED FOR
 DUMPSTER ENCLSORUES. PLEASE ENSURE THAT THE NEW
 DIMENSIONS ARE ACCOMODATED IN THE REVISED PLANS.
  
  
 NOTES:
  
 * PLEASE ENSURE ALL BUILDING PERMIT PLANS ARE
 CONSISTENT WITH THE APPROVED MINOR AMENDMENT (REFERENCE
 PB 1670K, CONDITIONALLY APPROVED ON 8/12/2019).
  
 * CONDITIONS IN RESOLUTION NO. 128-19 MUST BE MET.
  
 * MINOR AMENDMENT FOR THE AS-BUILTS REQUIRED.
  
 * ANY REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * ZONE: CPD (PALMS GATEWAY ? MITSUBISHI)
  
 * ZONE: SF7
  

Review Stop Z ZONING
Rev No 2 Status F Date 2019-07-24 Cont ID  
Sent By llouie Date 2019-07-24 Time   Rev Time 0.00
Received By llouie Date 2019-07-24 Time   Sent To  
Notes
2019-07-24 12:56:39** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) THIS PROJECT IS PENDING A MINOR PD AMENDMENT
 APPROVAL (REFERENCE: PB 1670K). THE MINOR PD AMENDMENT
 MUST BE APPROVED PRIOR TO ZONING APPROVAL OF THE
 BUILDING PERMIT.
  
 2.) ALL CONDITIONS IN RESOLUTION NO. 128-19 MUST BE
 SATISFIED.
  
  
 NOTES:
  
 * PLEASE ENSURE ALL BUILDING PERMIT PLANS ARE
 CONSISTENT WITH THE MINOR AMENDMENT ONCE APPROVED.
  
 * REVISION MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * REFERENCE: RESOLUTION NO. 128-19 AND PB 1670K (MINOR
 PD AMENDMENT)
  
 * ZONE: CPD (PALMS GATEWAY - MITSUBISHI)
  

Review Stop Z ZONING
Rev No 1 Status F Date 2019-04-26 Cont ID  
Sent By llouie Date 2019-04-26 Time   Rev Time  
Received By llouie Date 2019-04-26 Time   Sent To  
Notes
2019-04-26 09:51:40** FAILED **
  
 1.) THIS PROJECT IS PENDING APPROVAL FROM THE CITY
 COMMISSION. THE PROJECT IS SHEDULED TO BE HEARD BY THE
 CITY COMMISSION ON 5/6/19. ZONING WILL NOT
 REVIEW/APPROVE ANY PLANS PRIOR TO APPROVAL BY THE CITY
 COMMISSION.
  
 2.) INCONSISTENCIES DETECTED IN THE PROPOSED PLANS TO
 BE HEARD BY THE CITY COMMISSION AND THE PERMIT SET. ALL
 CONSTRUCTION PLANS SHALL MATCH THE APPROVED SET FOR
 CONSISTENCY.
  
  
 NOTES:
  
 * REFERENCE: PB 1670I (PALMS GATEWAY CPD - MITSUBISHI)
  
 * REVISIONS MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.