Plan Review Details - Permit 19040400
Plan Review Stops For Permit 19040400 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-05-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-05-06 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-05-06 |
Time |
08:56 |
Sent To |
|
|
Notes |
2019-05-06 09:01:16 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC 107, FBC R 301, PROVIDE AN ARCHITECTURAL QUALITY | | PLAN, DRAWN TO SCALE. PLAN SHOULD INCLUDE ALL | | STRUCTURAL DETAILS, WIND DESIGN CRITERIA, PRINTED NAME | | AND SIGNATURE OF INDIVIDUAL TAKING RESPONSIBILITY FOR | | THE DESIGN. | | | | 2. A CONCEPTUAL PLAN WAS PROVIDED FOR THE PROPOSED NEW | | WALL BUT NO STRUCTURAL DETAILS (FASTENERS, STEEL, | | ETC.). | | | | 3. "CEMENT BOARD" SPECIFIED AS AN EXTERIOR COMPONENT. | | PROVIDE SPEC SHEETS, PRODUCT APPROVAL. FASTENING | | PROPOSED AND RESISTANCE TO WIND NOT CLEAR, FBC R 301. | | | | 4. HARDIE BRAND VENTED SOFFIT SPECIFED. PROVIDE PRODUCT | | APPROVALS. IF NOT INSTALLED IN ACCORDANCE WITH THE | | PRODUCT APPROVAL, PROVIDE CALCULATIONS TO SHOW THAT THE | | PROPOSED INSTALLATION MEETS THE WIND DESIGN CRITERIA | | REQUIRED. | | | | A COMPLETE REVIEW CANNOT BE DONE AT THIS TIME DUE TO | | INSUFFICIENT INFORMATION. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-04-24 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-04-24 |
Time |
09:39 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-04-23 |
Time |
15:00 |
Sent To |
|
|
Notes |
2019-04-24 09:39:03 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF | | PLAN (BOTH COPIES) IS REQUIRED TO BE SIGNED BY PERSON | | RESPONSIBLE FOR THE DESIGN. PROVIDE CORRECTION. FS | | 481.229; WPB FBC 107.1, 107.2.1, 107.3.5.1.2 | | 2. IS THE WIRING FOR NEW LIGHT FIXTURES EXISTING, OR | | WILL THIS BE NEW CIRCUITRY? IF NEW WIRE IS TO BE | | INSTALLED, PROVIDE WIRE SIZE AND BREAKER SIZE, SHOWING | | WHERE FED FROM. WPB FBC 107.2.1; NEC 210.19, 310.15 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-05-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-05-06 |
Time |
09:01 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-04-09 |
Time |
15:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
pgreilih |
Date |
2019-04-29 |
Time |
|
Rev Time |
0.00 |
Received By |
pgreilic |
Date |
2019-04-29 |
Time |
10:40 |
Sent To |
|
|
Notes |
|
|
|