Plan Review Details - Permit 19040258
Plan Review Stops For Permit 19040258
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2020-01-16 Cont ID  
Sent By jgomez Date 2020-01-16 Time 10:55 Rev Time 0.00
Received By jgomez Date 2020-01-16 Time 09:29 Sent To P
Notes
2020-01-16 10:56:42REVISION SENT TO TIM LARGE'S DESK. JG.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2020-01-14 Cont ID  
Sent By jpearson Date 2020-01-14 Time 15:29 Rev Time 0.00
Received By jpearson Date 2020-01-14 Time 15:29 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2019-04-08 Cont ID  
Sent By jpearson Date 2019-04-08 Time 08:45 Rev Time 0.00
Received By jpearson Date 2019-04-08 Time 08:44 Sent To P
Notes
2019-04-08 08:44:48CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017
 6TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. REVISION PROVIDED DOES NOT INDICATE THE CHANGES FROM
 THE ORIGINAL PLAN. REVISIONS TO PLAN SHOULD BE CLOUDED
 FOR IDENTIFICATION AND EXPLAINED IN DETAIL. SIMPLY
 STATING "AS BUILT" ON THE PLAN IS NOT ACCEPTABLE.
 PROVIDE CORRECTION. WPB FBC 107.2.1
 2. IT APPEARS THAT THERE HAS BEEN SUBSTANTIAL WORK
 ADDED, BUT THE LOAD CALCULATION IS THE SAME AS BEFORE.
 INCLUDE CORRECTED LOAD CALCULATION SHOWING ALL LOADS.
 NEC 220; FBC RE E3602.2
 3. IT APPEARS THAT THERE HAS BEEN SUBSTANTIAL WORK
 ADDED, BUT THE SUBMITTAL FORM STATES THAT THERE IS NO
 ADDED VALUE. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE
 AND VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR.
 THIS IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC
 109.3
  
 END OF COMMENTS.
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2020-01-16 Cont ID  
Sent By tklarge Date 2020-01-16 Time 14:30 Rev Time 0.00
Received By tklarge Date 2020-01-10 Time 13:36 Sent To  
Notes
2020-01-13 13:37:23RESUB ROUTED TO JPEARSON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-04-08 Cont ID  
Sent By tklarge Date 2019-04-08 Time 10:09 Rev Time 0.00
Received By tklarge Date 2019-04-04 Time 16:26 Sent To  
Notes
2019-04-04 16:26:37REVISION ROUTED TO JPEARSON

Review Stop P PLUMBING
Rev No 2 Status P Date 2020-01-16 Cont ID  
Sent By tklarge Date 2020-01-16 Time 14:30 Rev Time 0.00
Received By tklarge Date 2020-01-16 Time 13:46 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-04-08 Cont ID  
Sent By tklarge Date 2019-04-08 Time 10:08 Rev Time 0.00
Received By tklarge Date 2019-04-08 Time 09:09 Sent To I
Notes
2019-04-08 10:08:38 
  
 1. IT APPEARS THAT THERE HAS BEEN SUBSTANTIAL WORK
 ADDED, BUT THE SUBMITTAL FORM STATES THAT THERE IS NO
 ADDED VALUE. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE
 AND VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR.
 THIS IS FOR TOTAL PROJECT. WPB FBC 109.3
 2) SUBMIT THE MANUFACTURER'S SPECIFICATIONS FOR THE
 STEAM UNIT.WPB AMEND. TO FBC SEC. 107.2.1.
 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE WALL
 HUNG TOILETS. WPB AMEND. TO FBC SEC. 107.2.1.
  
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY
 REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED
 SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD
 SHEETS.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  