Plan Review Details - Permit 19040215
Plan Review Stops For Permit 19040215
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-06-12 Cont ID  
Sent By dbattles Date 2019-06-12 Time 07:44 Rev Time 0.00
Received By dbattles Date 2019-06-12 Time 07:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-05-21 Cont ID  
Sent By dbattles Date 2019-05-21 Time 09:44 Rev Time 0.00
Received By dbattles Date 2019-05-20 Time 07:48 Sent To  
Notes
2019-05-21 09:46:10****CORRECTIONS****
 W.P.B. PERMIT: 1901
 REVIEWED: MAY 21, 2019
  
 DYLAN BATTLES
 BUILDING PLANS EXAMINER PX4191
 [email protected]
 561-805-6718
  
 FBC[AMENDED] = FLORIDA BUILDING CODE,6TH EDITION (2017)
 FBC[B] = FBC BUILDING
 FBC[EXISTING] = FBC EXISTING BUILDING
 FBC[A] = FBC ACCESSIBILITY
 FBC[E] = FBC ENERGY CONSERVATION
 FBC[R] = FBC RESIDENTIAL
  
 1. 107.2.1 FBC[AMENDED] PLACE A DIGITALLY CREATED IMAGE
 OF YOUR SEAL AND THE FOLLOWING SENTENCES WHERE AN
 ORIGINAL SIGNATURE WOULD APPEAR IF THE ITEM WERE BEING
 PHYSICALLY SIGNED DATED AND SEALED. THE SENTENCES CAN
 BE PART OF THE DIGITAL SIGNATURE CUSTOM APPEARANCE
 AVAILABLE IN THE SIGNING TOOL, OR THEY CAN BE PLACED ON
 THE DOCUMENT OUTSIDE OF THE DIGITAL SIGNATURE BLOCK.
 THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY
 [LICENSEE, RA, OR LS] ON THE DATE AND/OR TIME STAMP
 SHOWN USING A DIGITAL SIGNATURE.
 - PLEASE ADD A DIGITALLY CREATED IMAGE OF YOUR SEAL TO
 THE A SHEETS.
  
 2. 107.3.4.1 FBC[AMENDED] PROVIDE PRODUCT APPROVALS FOR
 EXTERIOR DOORS AND TRANSOMS OR INDICATE THAT YOU WOULD
 LIKE THEM DEFERED.
  
 3. 301.1 FBC[EXISTING] GENERAL. THE REPAIR, ALTERATION,
 CHANGE OF OCCUPANCY, ADDITION OR RELOCATION OF ALL
 EXISTING BUILDINGS SHALL COMPLY WITH ONE OF THE METHODS
 LISTED IN SECTIONS 301.1.1 THROUGH 301.1.3 AS SELECTED
 BY THE APPLICANT. SECTIONS 301.1.1 THROUGH 301.1.3
 SHALL NOT BE APPLIED IN COMBINATION WITH EACH OTHER.
 A) 301.1.1 FBC[EXISTING] PRESCRIPTIVE COMPLIANCE
 METHOD. REPAIRS, ALTERATIONS, ADDITIONS AND CHANGES OF
 OCCUPANCY COMPLYING WITH CHAPTER 4 OF THIS CODE IN
 BUILDINGS COMPLYING WITH THE FLORIDA FIRE PREVENTION
 CODE SHALL BE CONSIDERED IN COMPLIANCE WITH THE
 PROVISIONS OF THIS CODE.
 B) 301.1.2 FBC[EXISTING] WORK AREA COMPLIANCE METHOD.
 REPAIRS, ALTERATIONS, ADDITIONS, CHANGES IN OCCUPANCY
 AND RELOCATED BUILDINGS COMPLYING WITH THE APPLICABLE
 REQUIREMENTS OF CHAPTERS 5 THROUGH 13 OF THIS CODE
 SHALL BE CONSIDERED IN COMPLIANCE WITH THE PROVISIONS
 OF THIS CODE.
 C) 301.1.3 FBC[EXISTING] PERFORMANCE COMPLIANCE METHOD.
 REPAIRS, ALTERATIONS, ADDITIONS, CHANGES IN OCCUPANCY
 AND RELOCATED BUILDINGS COMPLYING WITH CHAPTER 14 OF
 THIS CODE SHALL BE CONSIDERED IN COMPLIANCE WITH THE
 PROVISIONS OF THIS CODE.
 - WHICH METHOD IS BEING USED FOR COMPLIANCE?
 (PRESCRIPTIVE,WORK AREA OR PERFORMANCE)
  
 4. 503.1 FBC[CE] GENERAL. ALTERATIONS TO ANY BUILDING
 OR STRUCTURE SHALL COMPLY WITH THE REQUIREMENTS OF THE
 CODE FOR NEW CONSTRUCTION. ALTERATIONS SHALL BE SUCH
 THAT THE EXISTING BUILDING OR STRUCTURE IS NO LESS
 CONFORMING TO THE PROVISIONS OF THIS CODE THAN THE
 EXISTING BUILDING OR STRUCTURE WAS PRIOR TO THE
 ALTERATION. (SEE EXCEPTIONS FOR 503.1)
  
 5. 503.2 FBC[CE] CHANGE IN SPACE CONDITIONING. ANY
 NONCONDITIONED OR LOW-ENERGY SPACE THAT IS ALTERED TO
 BECOME CONDITIONED SPACE SHALL BE REQUIRED TO BE
 BROUGHT INTO FULL COMPLIANCE WITH THIS CODE.
  
 6. 503.3 FBC[CE] BUILDING ENVELOPE. NEW BUILDING
 ENVELOPE ASSEMBLIES THAT ARE PART OF THE ALTERATION
 SHALL COMPLY WITH SECTIONS C402.1 THROUGH C402.5.
 - (SEE SECTIONS C402.1 THROUGH C402.5)
  
 7. 508.1 FBC[B] GENERAL. EACH PORTION OF A BUILDING
 SHALL BE INDIVIDUALLY CLASSIFIED IN ACCORDANCE WITH
 SECTION 302.1. WHERE A BUILDING CONTAINS MORE THAN ONE
 OCCUPANCY GROUP, THE BUILDING OR PORTION THEREOF SHALL
 COMPLY WITH THE APPLICABLE PROVISIONS OF SECTION 508.2,
 508.3 OR 508.4, OR A COMBINATION OF THESE SECTIONS.
 - PROVIDE AREA OF EXISTING BUILDING BASED ON OCCUPANCY
 TYPE, AND PROVIDE PROPOSED NEW AREAS BASED ON OCCUPANY
 TYPE. THE COMBINATION OF AREAS SHOULD EQUAL THE TOTAL
 BUILDING AREA.
  
 8. 806.3 FBC[B] COMBUSTIBLE DECORATIVE MATERIALS. IN
 OTHER THAN GROUP I-3, CURTAINS, DRAPERIES, FABRIC
 HANGINGS AND SIMILAR COMBUSTIBLE DECORATIVE MATERIALS
 SUSPENDED FROM WALLS OR CEILINGS SHALL COMPLY WITH
 SECTION 806.4 AND SHALL NOT EXCEED 10 PERCENT OF THE
 SPECIFIC WALL OR CEILING AREA TO WHICH SUCH MATERIALS
 ARE ATTACHED. FIXED OR MOVABLE WALLS AND PARTITIONS,
 PANELING, WALL PADS AND CRASH PADS APPLIED STRUCTURALLY
 OR FOR DECORATION, ACOUSTICAL CORRECTION, SURFACE
 INSULATION OR OTHER PURPOSES SHALL BE CONSIDERED
 INTERIOR FINISH SHALL COMPLY WITH SECTION 803 AND SHALL
 NOT BE CONSIDERED DECORATIVE MATERIALS OR FURNISHINGS.
 (SEE EXCEPTIONS FOR 806.3)
 - PROVIDE SUBMITTAL TO INSPECTOR TO VERIFY COMPLIANCE
 WITH 806.3 IF DRAPERIES ARE BEING INSTALLED.
  
 9. ART IN PUBLIC PLACES. THE CITY OF WEST PALM BEACH
 ART IN PUBLIC PLACES ORDINANCE REQUIREMENT THAT APPLIES
 TO ANY REMODEL OR NEW CONSTRUCTION PROJECT FOR WHICH
 THE PERMIT APPLICATION WAS SUBMITTED AFTER 6/29/14, AND
 THE TOTAL PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR
 GREATER THAN $750,000 WILL NEED TO COMPLY WITH THIS
 ORDINANCE. PER CITY OF WEST PALM BEACH ORDINANCE NO.
 4504-14, AND CITY OF WEST PALM BEACH CODE OF
 ORDINANCES, ARTICLE V, ART IN PUBLIC PLACES, SECTION
 78-123(A) AND SECTION 78-126(A), THE ART ASSESSMENT IS
 1% OF THE TOTAL PROJECT CONSTRUCTION COST. PER CITY OF
 WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V, ART IN
 PUBLIC PLACES, SECTION 78-122, RENOVATION AND NEW
 CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO THE
 ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE
 PROJECTS. SEC. 78-129. - PUBLIC ART ASSESSMENT FOR
 PRIVATE DEVELOPMENT. (A) APPLICABILITY. THE PROVISIONS
 OF THIS ARTICLE AND THE PUBLIC ART ASSESSMENT SECTION
 SHALL APPLY TO ALL PRIVATE DEVELOPMENT PROJECTS,
 INCLUDING NEW CONSTRUCTION, OR THE RENOVATION OR
 IMPROVEMENT OF AN EXISTING BUILDING, WHERE TOTAL
 CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN
 $750,000.00. ALL BUILDINGS WITHIN NEW PLANNED
 DEVELOPMENTS SHALL BE ASSESSED CUMULATIVELY TOWARDS
 THIS ART IN PUBLIC PLACES REQUIREMENT, EVEN IF THE
 BUILDINGS ARE PERMITTED SEPARATELY OR DEVELOPED IN
 PHASES. THE PROVISIONS OF THIS SECTION APPLY TO NEW
 DEVELOPMENT OR NEW CONSTRUCTION WITHIN EXISTING PLANNED
 DEVELOPMENTS.
 - THIS PROJECT MEETS THE CRITERIA TO PROVIDE AIPP.
 PLEASE CONTACT: MS. SYBILLE WELTER ART IN PUBLIC PLACES
 COORDINATOR 822-1515 E-MAIL: [email protected]
  
 10. F.S. 553.79(5) THRESHOLD BUILDING.
 THIS PROJECT MEETS THE DEFINITION OF A THRESHOLD
 BUILDING. THE FOLLOWING IS REQUIRED PRIOR TO
 COMMENCEMENT.
 A) COMPLETE THE THRESHOLD / SPECIAL INSPECTOR AGREEMENT
 OF UNDERSTANDING; THIS HAS BEEN SENT VIA EMAIL TO
 CONTRACTOR. IF PDF OF AGREEMENT IS NEEDED PLEASE
 CONTACT THE BUILDING PLAN REVIEWER AND THEY WILL
 PROVIDE VIA E-MAIL.
 B) PROVIDE RESUMES AND COPIES OF LICENSES FOR ALL
 PROPOSED INSPECTORS. PLEASE INCLUDE AS MANY ADDITIONAL
 INSPECTORS AS POSSIBLE BECAUSE THESE ARE THE ONLY
 PEOPLE THAT THE CHIEF BUILDING INSPECTOR WILL ALLOW TO
 BE ON-SITE.
 C) ALL PLANS ARE TO INCLUDE THE THRESHOLD STATEMENT
 REQUIRED BY FS553.79(7)(D). ?ALL PLANS FOR THE BUILDING
 WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE
 ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT
 THAT, TO THE BEST OF THE ARCHITECT?S OR ENGINEER?S
 KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE
 APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE
 FIRE SAFETY STANDARDS AS DETERMINED BY THE LOCAL
 AUTHORITY IN ACCORDANCE WITH THIS CHAPTER 553 AND
 CHAPTER 633.?
 D) THRESHOLD INSPECTION PLAN REQUIRED, FS553.79(5)A).
 - S SHEETS WILL NEED TO CONTAIN THE STATEMENT PROVIDED
 IN LINE C ABOVE. A THRESHOLD PLAN SHOULD ALSO BE ADDED
 OR PROVIDED SEPARATELY TO STATE THE RESPONSIBILITIES OF
 THE THRESHOLD INSPECTOR. THE THRESHOLD AGREEMENT AND
 RESUMES CAN BE PROVIDED VIA-EMAIL. UPON REVIEW BY OUR
 CHIEF BUILDING INSPECTOR 3 ORIGINAL COPIES WILL BE
 REQUESTED.
  
 NOTES:
  
 -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW
 EACH COMMENT IS BEING ADDRESSED.
  
 -COMMENTS ARE A BRIEF OVERVIEW OF CODE SECTIONS.
 FURTHER REVIEW OF THE REFERENCED CODE SECTIONS WILL BE
 REQUIRED.
  
 -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
  
 -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS
 OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS)
 SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT
 DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER
 SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID"
 OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS
 APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE
 NEED "VOID", RENDERING THEM NOT USABLE.
  
 PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F
 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME
 [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2019-06-12 Cont ID  
Sent By jleahy Date 2019-06-12 Time 12:56 Rev Time 0.00
Received By jleahy Date 2019-06-12 Time 12:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-05-08 Cont ID  
Sent By jleahy Date 2019-05-08 Time 14:38 Rev Time 0.00
Received By jleahy Date 2019-05-06 Time 07:12 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 2 Status P Date 2019-06-12 Cont ID  
Sent By jleahy Date 2019-06-12 Time 12:59 Rev Time 0.00
Received By jleahy Date 2019-06-12 Time 12:59 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2019-05-08 Cont ID  
Sent By jleahy Date 2019-05-08 Time 14:39 Rev Time 0.00
Received By jleahy Date 2019-05-08 Time 14:39 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2019-06-10 Cont ID  
Sent By pleduc Date 2019-06-10 Time   Rev Time 0.00
Received By pleduc Date 2019-06-10 Time 10:27 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2019-04-12 Cont ID  
Sent By pleduc Date 2019-04-12 Time   Rev Time 0.00
Received By pleduc Date 2019-04-12 Time 11:24 Sent To  
Notes
2019-04-12 13:52:55THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
  
 1) SHEET AE601 - THERE ARE NO INDICATIONS OF REQUIRED
 EXIT HARDWARE ON DOORS WITHIN A MEANS OF EGRESS;
  
 DOOR(S) 188A, 188B 118A, 184, 169B
  
 PER NFPA 101, CHAPTER 12:
  
 12.2.2.2.3 ANY DOOR IN A REQUIRED MEANS OF EGRESS FROM
 AN AREA HAVING
 AN OCCUPANT LOAD OF 100 OR MORE PERSONS SHALL BE
 PERMITTED TO BE
 PROVIDED WITH A LATCH OR LOCK ONLY IF THE LATCH OR LOCK
 IS PANIC
 HARDWARE OR FIRE EXIT HARDWARE COMPLYING WITH 7.2.1.7,
 UNLESS
 OTHERWISE PERMITTED BY ONE OF THE FOLLOWING:
 (1) THIS REQUIREMENT SHALL NOT APPLY TO DELAYED-EGRESS
 LOCKS AS
 PERMITTED IN 12.2.2.2.5.
 (2) THIS REQUIREMENT SHALL NOT APPLY TO
 ACCESS-CONTROLLED EGRESS DOORS
 AS PERMITTED IN 12.2.2.2.6.
 12.2.2.2.4 LOCKING DEVICES COMPLYING WITH 7.2.1.5.5
 SHALL BE PERMITTED
 TO BE USED ON A SINGLE DOOR OR A SINGLE PAIR OF DOORS
 IF BOTH OF THE
 FOLLOWING CONDITIONS APPLY:
 (1) THE DOOR OR PAIR OF DOORS SERVE AS THE MAIN EXIT
 AND THE ASSEMBLY
 OCCUPANCY HAS AN OCCUPANT LOAD NOT GREATER THAN 500.
 (2) ANY LATCHING DEVICES ON SUCH A DOOR(S) FROM AN
 ASSEMBLY
 OCCUPANCY HAVING AN OCCUPANT LOAD OF 100 OR MORE ARE
 RELEASED
 BY PANIC HARDWARE OR FIRE EXIT HARDWARE.
  
  
  
 2) SHEET AE601 - THERE ARE INDICATIONS OF HOLD OPEN ON
 SEVERAL DOORS.
  
 DOES THIS INDICATE MAG-LOCKS TIED INTO THE FIRE ALARM.
  
 PLEASE REVIEW AND CLARIFY OR CORRECT.
  
  
  
 3) SHEET AE 401 - THERE ARE DOORS INDICATED ON SHEETS
 AE 401 & AE 402 WITH FIRE RATED WALLS. THE DOOR
 SCHEDULE DOES NOT INDICATE ANY RATING ON THE DDORS.
  
 THE FOLLOWING DOORS ARE, BUT MAY NOT BE LIMITED TO :
 188A & B, 184, 169B, 160.
  
 PLEASE REVIEW AND CORRECT OR JUSTIFY WHAY THE RATINGS
 ARE NOT REQUIRED.
  
 PLEASE BE SURE TO CHECK ALL THE DOORS TO ENSURE ALL
 DOORS WITHIN FIRE RATED WALLS CARRY THE REQUIRED
 RATING.
  
  
  
  
 4) SHEET E 1 - THERE ARE INDICATIONS OF FIRE ALARM
 EQUIPEMNT DEVICES IN THE SYMBOL AND LEGEND AREA.
 COMMNET # 32 INDICATES FIRE ALARM MANUFACTURER
 INFORMATION.
  
 IT DOES NOT INDICATE THAT ANY WORK ON THE FIRE ALARM
 SYSTEM SHALL BE DONE UNDER SEPARATE PERMIT AND SHOP
 DRAWINGS BY CERTIFIED FIRE ALARM CONTRACTORS.
  
 PLEASE REVIEW AND PROVIDE AN APPLICABLE NOTE OF
 ACKNOWLEDGEMENT.
  
  
  
  
 5) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
  
 6) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2019-07-17 Cont ID  
Sent By shill Date 2019-07-17 Time 08:39 Rev Time 0.00
Received By shill Date 2019-07-01 Time 15:20 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2019-06-27 Time   Rev Time 0.00
Received By lmarchan Date 2019-06-05 Time 10:41 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-05-21 Cont ID  
Sent By dbattles Date 2019-05-21 Time 09:46 Rev Time 0.00
Received By dbattles Date 2019-04-09 Time 11:28 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2019-07-22 Cont ID  
Sent By lmarchan Date 2019-07-22 Time 09:52 Rev Time 0.00
Received By lmarchan Date 2019-07-09 Time 14:02 Sent To  
Notes
2019-07-22 09:52:39RECEIPT - MU-2019-22571 - $9231.48 PAID
2019-07-09 14:02:517/9/19 EMAILED IMPACT FEE OFFICE FOR REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2019-05-21 Cont ID  
Sent By dbattles Date 2019-05-21 Time 08:02 Rev Time 0.00
Received By dbattles Date 2019-05-20 Time 07:48 Sent To  
Notes
2019-05-21 08:02:15109 FBC[AMENDED] PLANS WILL BE REVIEWED BY THE PBC
 IMPACT FEE OFFICE DIGITALLY VIA PROJECTDOX UPON
 NOTIFICATION BY THIS OFFICE. NOTIFICATION MAY OCCUR
 WHEN PLANS ARE NEAREST FINAL FORM. YOU MAY COORDINATE
 WITH THE IMPACT FEE OFFICE AT (561) 233-5025 OR SIMPLY
 UPLOAD THE MUNICIPAL IMPACT FEE QUESTIONNAIRE FORM TO
 YOUR PROJECT AND NAME THE FILE MUNICIPAL IMPACT FEE
 QUESTIONNAIRE. THE FORM CAN BE FOUND AT: HTTP://DISCOVE
 R.PBCGOV.ORG/PZB/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QU
 ESTIONNAIRE.PDF UPON APPROVAL AND FEE PAYMENT, PLEASE
 UPLOAD THE RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2019-06-27 Cont ID  
Sent By ccole Date 2019-06-27 Time 12:01 Rev Time 0.00
Received By ccole Date 2019-06-27 Time 12:01 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2019-05-08 Cont ID  
Sent By ccole Date 2019-05-08 Time 17:26 Rev Time 0.00
Received By ccole Date 2019-05-06 Time 17:05 Sent To  
Notes
2019-05-08 17:43:091ST REVIEW FBC-2017 MECHANICAL
 PERMIT #19040215
 5/8/2019
  
 CODES IN EFFECT:
  
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M3: THE OUTDOOR AIR RATE TABLE IS INCORRECTLY
 INDICATING THE MINIMUM O/A CFMS AT 262, HOWEVER THE
 MINIMUM RATE IS 4341 WHICH IS LISTED AS THE MAXIMUM IN
 THE TABLE- REFER TO TABLE 403.3.1.1 FBC M. PLEASE
 PROVIDE THE SPECIFIC FBC M OR ASHRAE CODE SECTION USED
 AS REFERENCE FOR THE DESIGN VENTILATION SYSTEM AND NOTE
 #2 UNDER THE TABLE.
  
 2) SHEETS G1101 & M5: PLEASE CLARIFY IF THE WALLS
 ENCLOSING THE MECHANICAL ROOMS ARE FIRE-RATED, OR ANY
 OTHER WALLS THAT ARE BEING PENETRATED BY DUCTS- SECTION
 107.2.1 WPB AND SECTION 607 FBC M.
  
 3) M5: PLEASE PLACE NOTES AND SYMBOLS ON THE PLANS TO
 INDICATE THE LOCATIONS OF THE REQUIRED DUCT SMOKE
 DETECTORS IN THE SUPPLY SYSTEMS OF AHU 1-1 AND AHU 1-4,
 AND THE REQUIRED O/A DAMPERS FOR THE SYSTEMS- SEE
 SECTIONS 606.2.1 FBC M, AND SECTION C403.2.4.3 FBC EC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2019-07-11 Cont ID  
Sent By jesmith Date 2019-07-11 Time 09:02 Rev Time 0.00
Received By jesmith Date   Time   Sent To  
Notes
2019-07-11 09:02:34PLUMBING COMMEMTS: APPROVED
 PROVISO
 RE: PLAN SHEET P-2, REV 3; SANITARY RISER FOR SERVICE
 BAR
 3" FS FIXTURE DRAIN SHALL BE ADDED TO DRAWING OF RECORD
 AND SUBMITTED FOR APPROVAL PRIOR TO FINAL INSPECTION;
 SEE REDLINED COMMENT ON PLAN.
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2019-06-20 Cont ID  
Sent By jesmith Date 2019-06-20 Time 13:19 Rev Time 0.00
Received By jesmith Date 2019-06-20 Time 09:23 Sent To  
Notes
2019-06-20 13:19:10CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2017 6TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1.
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017
 6TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION
 NFPA 30A
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
  
 2ND REVIEW
 PLUMBING COMMEMTS: DENIED
 ORIGINAL COMMENTS
 1. COMPLIED
 2. COMPLIED
 3. COMPLIED
 4. REQUIRES FURTHER CLARIFICATION; PLAN SHEET G1101,
 PLUMBING FIXTURE COUNT CHART, INDICATES THAT ONE (1)
 SERVICE (MOP) SINK IS REQUIRED FOR THE BUILDING WHICH
 IS CORRECT. THE PLUMBING FIXTURE COUNT CHART INDICATES
 THERE ARE THREE (3) SERVICE (MOP) SINKS IN THE BUILDING
 WHICH EXCEEDS THE REQUIREMENTS OF FBC PL 403, TABLE
 403.1. HOWEVER, CHART REFERENCES THE FLORIDA PLUMBING
 CODE 2010. PER WPB FBC 107.2.1, REFENCE THE FLORIDA
 BUILDING CODE, PLUMBING 2017. ADDITIONALLY, REFLECT
 CONFIRM THE ACTUAL FIXTURE COUNT FOR THE BUILDING AND
 ACCURATELY REFLECT ON THE CHART.
 5. CLARIFIED
 6. CLARIFIED; THERE IS NO MOP SINK NEW OR EXISTING
 SHOWN IN ROOM 158.
 7. DID NOT COMPLY; TO BE CLEAR, THE WATER RISER DIAGRAM
 SHOWN ON P-2 ADDRESSES THE TOILET ROOMS 158 AND 159
 BUT, DOES NOT ADDRESS THE SERVICE BAR ROOM 193. PER WPB
 FBC 107.2.1, PROVIDE WATER RISER DIAGRAM TO ADDRESS
 THIS ROOM.
 8. COMPLIED
 9. COMPLIED
 10. DID NOT COMPLY. TEMPERED WATER IS REQUIRED TO THE
 LAVATORIES PER FBC-PLUMBING SEC.416.5. PER WPB FBC
 107.2.1, PROVIDE NOTE REQUIRING TEMPERED WATER FOR THE
 LAVATORIES IN ACCORDANCE WITH THE REQUIREMENTS OF FBC
 PL 416.5.
  
 NEW COMMENTS
 1. RE: P-2 SANITARY RISER DIAGRAM; EACH WET-VENTED
 FIXTURE DRAIN SHALL CONNECT INDEPENDENTLY TO THE
 HORIZONTAL WET VENT PER FBC PL 912.1. TO BE CLEAR, THE
 FLOOR DRAIN SHALL NOT CONNECT TO THE WATER CLOSET AHEAD
 OF THE VENT. CONNECT DOWNSTREAM OF VERTICAL PORTION OF
 THE WET VENT. PER WPB FBC 107.2.1, SHOW ON P-2,
 SANITARY RISER DIAGRAM AND ON P-3, SANITARY PLUMBING
 PLAN.
 2. PER WPB FBC 107.2.1, PROVIDE SANITARY RISER DIAGRAM
 TO ADDRESS THE SERVICE BAR ROOM 193.
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 PHONE 561-805-6715
  
 19040215 8225 IBIS BLVD
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-05-07 Cont ID  
Sent By tklarge Date 2019-05-07 Time 13:30 Rev Time 0.00
Received By tklarge Date 2019-05-02 Time 14:54 Sent To  
Notes
2019-05-07 11:55:081) SHT.AE-5.01 - THE TOILET PAPER DISPENSER FOR THE
 ACCESSIBLE WATER CLOSET SHALL BE LOCATED 7 INCHES
 MINIMUM AND 9 INCHES MAXIMUM IN FRONT OF THE WATER
 CLOSET MEASURED TO THE CENTERLINE OF THE DISPENSER.
 2017 FBC - ACCESS. SEC.604.7.
 2) SHT. AE-5.01 -THE FLUSH HANDLE FOR THE ACCESSIBLE
 WATER CLOSET SHALL BE LOCATED ON THE OPEN SIDE OF THE
 TOILET. THE DETAIL SHOWS THE HANDLE ON THE WALL SIDE.
 2017 FBC - ACCESS. SEC. 604.6.
 3) SHT. AE-5.01 - THE RIM OF THE URINAL SHALL BE
 LOCATED A MAXIMUM OF 17 INCHES ABOVE THE FINISH FLOOR.
 2017 FBC-ACCESS. SEC.605.2. THE URINAL SHALL BE 13 1/2
 INCHES DEEP MINIMUM MEASURED FROM THE OUTER FACE OF THE
 URINAL RIM TO THE BACK OF THE FIXTURE.
 4) SHT. P-2 SHOWS THE MOP SINK TO BE REMOVED. A MOP
 SINK IS A REQUIRED FIXTURE FOR THIS OCCUPANCY
 CLASSIFICATION PER TABLE 403.1 OF THE FBC-PLUMBING.
 5) SHT.P-3 IS VAGUE AS TO THE SCOPE OF PLUMBING WORK
 BEING DONE. CLEARLY SHOW ON THE PLAN THE SCOPE OF WORK
 THAT IS BEING DONE. SHOW WHICH PLUMBING & FIXTURES ARE
 EXISTING TO REMAIN, EXISTING TO BE REMOVED AND WHAT IS
 NEW. IS ANY PLUMBING BEING ALTERED IN TOILET ROOMS
 #158? WPB AMEND. TO FBC SEC. 107.2.1.
 6) SHT P-3 - IS THE MOP SINK IN STORAGE ROOM #158 NEW
 OR EXISTING? CLARIFY ON THE PLANS.
 7) SUBMIT A WATER RISER DIAGRAM FOR ANY NEW WATER
 PIPING TO INSTALLED. WPB AMEND.TO FBC SEC.107.3.5.1.3.
 8) SHT.P-2 - THE SANITARY RISER SHOWS A 4 INCH VENT FOR
 A 3 INCH SANITARY DRAIN. CLARIFY.
 9) SHT. P-2 - THE SANITARY RISER FOR THE TOILET ROOMS
 SHOWS AN 1 1/2 INCH VENT FOR THE LAVATORY AND WATER
 CLOSET. THE DRAIN IS SHOWN AS 4 INCH. THE VENT SHALL
 NOT BE LESS THAN ONE-HALF THE SIZE OF THE DRAIN SERVED.
 2017 FBC-PLUMBING SEC.906.1.
 10) TEMPERED WATER IS REQUIRED TO THE LAVATORIES PER
 FBC-PLUMBING SEC.416.5.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2019-07-09 Cont ID  
Sent By shill Date 2019-07-09 Time 06:04 Rev Time 0.00
Received By shill Date 2019-07-09 Time 06:01 Sent To  
Notes
2019-07-09 06:06:35PROVISO:
 JASON D BARBER PE, CHARLES GABLEMAN PE, TO OBTAIN 3RD
 PARTY DIGITAL SIGNATURE
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2019-06-27 Cont ID  
Sent By ccole Date 2019-06-27 Time 12:57 Rev Time 0.00
Received By ccole Date 2019-06-27 Time 12:57 Sent To  
Notes
2019-06-27 13:04:01THE MEP ENGINEERS- JASON BARBER P.E. AND CHARLES C.
 GABLEMAN P.E. WERE INFORMED THAT THEY CAN NO LONGER
 SELF CERTIFY THEIR DIGITAL SIGNATURES, AND MUST ALSO
 PROVIDE TITLE BLOCKS WITH A STATEMENT THAT INDICATES
 THE PLANS HAVE BEEN DIGITSALLY SIGNED AND SEALED- FAC
 61G15-23.005.
2019-06-20 13:24:46PLUMBING SHEETS SIGNATURE IS BY ENGINEER AND IS SELF
 CERTIFIED; REQUIRES THIRD PARTY CERTIFICATION JESMITH
 6/20/19
2019-06-12 13:02:51ELECTRICAL SIGNATURE OK JLEAHY
2019-06-12 07:44:20OK - S-SHEETS
 OK - A-SHEETS

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2019-05-21 Cont ID  
Sent By dbattles Date 2019-05-21 Time 07:52 Rev Time 0.00
Received By dbattles Date 2019-05-21 Time 07:52 Sent To  
Notes
2019-05-21 08:00:35DIGITAL SIGNATURE IS GOOD FOR ALL SHEETS AT INITIAL
 REVIEW (ALL TRADES)
 ANY ADDITIONAL SHEETS FOR COMMENTS RESPONSE SUBMITTAL
 WILL NEED TO BE DIGITALLY SIGNED.
  
 THS A SHEETS HAVE A DIGITAL SIGNATURE, BUT IN ADDITION
 THEY NEED A GRAPHIC REPRESENTATION OF SEAL (SEE BELOW)
  
 107.2.1 FBC[AMENDED] PLACE A DIGITALLY CREATED IMAGE OF
 YOUR SEAL AND THE FOLLOWING SENTENCES WHERE AN ORIGINAL
 SIGNATURE WOULD APPEAR IF THE ITEM WERE BEING
 PHYSICALLY SIGNED DATED AND SEALED. THE SENTENCES CAN
 BE PART OF THE DIGITAL SIGNATURE CUSTOM APPEARANCE
 AVAILABLE IN THE SIGNING TOOL, OR THEY CAN BE PLACED ON
 THE DOCUMENT OUTSIDE OF THE DIGITAL SIGNATURE BLOCK.
 "THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY
 "[LICENSEE, RA, OR LS] ON THE DATE AND/OR TIME STAMP
 SHOWN USING A DIGITAL SIGNATURE.

Review Stop Z ZONING
Rev No 3 Status P Date   Cont ID  
Sent By   Date 2019-07-09 Time   Rev Time 0.00
Received By pgreilic Date 2019-07-09 Time 09:35 Sent To  
Notes
2019-07-09 09:37:191.) SITE PLAN PROVIDED DOES NOT MATCH APPROVED SITE
 PLAN PER RESOLUTION 35-19. PROPOSED CHANGES WILL
 REQUIRE A MINOR PLANNED DEVELOPMENT AMENDMENT PRIOR TO
 ISSUANCE OF FINAL CERTIFICATE OF OCCUPANCY
 2.) LANDSCAPE PERMIT REQUIRED
 3.) ALL PRIVATE DEVELOPMENT PROJECTS, INCLUDING NEW
 CONSTRUCTION, OR THE RENOVATION OR IMPROVEMENT OF AN
 EXISTING BUILDING, WHERE THE TOTAL CONSTRUCTION COSTS
 ARE EQUAL OR GREATER THAN $750,000 IS SUBJECT TO THE
 ART IN PUBLIC PLACES REQUIREMENTS OF CHAPTER 78,
 ARTICLE V, OF THE CITY?S CODE OF ORDINANCES. CONTACT
 SYBILLE WELTER @ 561-822-1521 OR [email protected] FOR
 ADDITIONAL INFORMATION
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date   Cont ID  
Sent By   Date 2019-06-17 Time   Rev Time 0.00
Received By pgreilic Date 2019-06-17 Time 13:36 Sent To  
Notes
2019-06-17 13:40:241.) SITE PLAN PROVIDED DOES NOT MATCH APPROVED SITE
 PLAN PER RESOLUTION 35-19. PROPOSED CHANGES WILL
 REQUIRE A MINOR PLANNED DEVELOPMENT AMENDMENT PRIOR TO
 ISSUANCE OF FINAL CERTIFICATE OF OCCUPANCY
 2.) LANDSCAPE PERMIT REQUIRED
 3.) ALL PRIVATE DEVELOPMENT PROJECTS, INCLUDING NEW
 CONSTRUCTION, OR THE RENOVATION OR IMPROVEMENT OF AN
 EXISTING BUILDING, WHERE THE TOTAL CONSTRUCTION COSTS
 ARE EQUAL OR GREATER THAN $750,000 IS SUBJECT TO THE
 ART IN PUBLIC PLACES REQUIREMENTS OF CHAPTER 78,
 ARTICLE V, OF THE CITY?S CODE OF ORDINANCES. CONTACT
 SYBILLE WELTER @ 561-822-1521 OR [email protected] FOR
 ADDITIONAL INFORMATION
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By pgreilic Date 2019-05-14 Time   Rev Time 0.00
Received By pgreilic Date 2019-05-14 Time 15:07 Sent To  
Notes
2019-05-14 15:08:221.) PROVIDE APPROVED SITE PLAN PER MAJOR PD AMENDMENT
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved