Plan Review Details - Permit 19040094
Plan Review Stops For Permit 19040094 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-02-02 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2021-02-02 |
Time |
14:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2020-08-10 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2020-08-10 |
Time |
16:02 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2020-08-10 |
Time |
15:30 |
Sent To |
|
|
Notes |
2020-08-10 16:02:21 | 2017 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 19040094 | | ADD: 905 9TH ST. / PCN: 74-43-43-16-01-140-0130 | | CONT: SUNRISE CITY | | TEL: 561-350-5866 | | E-MAIL: [email protected] | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 3RD REVIEW | | DATE: MON. AUGUST 10TH/2020 | | ACTION: DENIED | | | | 1-6) SEMI- COMPLIED. THIS IS THE 3RD REVIEW WITH A SET | | OF PLANS THAT ARE ORIGINAL SIGNED AND SEALED PLANS. | | THE SHEET A-0.3 INDICATES BETWEEN THE R2 OCCUPANCIES | | THERE IS A ONE HOUR FIRE RATED WALL ALL THE WAY TO THE | | ROOF DECK. THE PLANS ARE SILENT AS TO WHAT MATERIALS | | ARE GOING TO MAKE UP THE ONE HOUR FIRE RATING. SHEET | | A-3.1 INDICATES THE TENANT SEPARATION WALLS WITH A WALL | | TYPE IDENTIFICATION TAG, (F) 1 5/8 METAL FURRING WALL. | | NOT METAL STUD WALL BUT ONLY METAL FURRING, METAL | | FURRING IS USUALLY APPLIED TO CONCRETE BLOCK | | WALLSPLEASE PROVIDE EITHER A UL WALL LISTING AND SHOW | | THE WALL COMPONENTS OR GYPSUM ASSOCIATION WALL LISTING | | AND THEIR COMPONENTS AND HOURLY FIRE RATING. PLEASE | | SHOW COMPLIANCE WITH THE 2017 FBC-B SECTION 420.2 | | SEPARATION WALLS/ FIRE PARTITIONS. THE COMMON WALL | | BETWEEN THE R-2 UNITS NEEDS TO SHOW COMPLIANCE WITH THE | | 2017 FBC-B SECTION 708, FIRE PARTITIONS. PLEASE SHOW | | COMPLIANCE WITH 2017 FBC-B SECTION: | | 708.3 FIRE-RESISTANCE RATING. FIRE PARTITIONS SHALL | | HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 1 HOUR. | | 708.4 CONTINUITY. FIRE PARTITIONS SHALL EXTEND FROM THE | | TOP OF THE FOUNDATION OR FLOOR/CEILING ASSEMBLY BELOW | | TO THE UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, SLAB | | OR DECK ABOVE OR TO THE FIRE-RESISTANCE-RATED | | FLOOR/CEILING OR ROOF/CEILING ASSEMBLY ABOVE, AND SHALL | | BE SECURELY ATTACHED THERETO. | | | | 6) 3RD REQUEST. THERE SEEMS TO BE A DISCREPANCY WITHIN | | THE SET OF PLANS. SHEET A-0.4 THE DEMO PLAN STATES ALL | | EXTERIOR WINDOWS AND DOORS TO REMAIN. IDENTIFIED THE | | COMMENT WITH RED CIRCLEE. WHEREAS SHEET A-3.1 NOTE # 2 | | IN THE LOWER LEFT HAND CORNER OF THE SHEET INDICATES | | THE EXISTING WINDOWS AND DOORS ARE TO BE REPLACED | | IDENTIFIED WITH RED CIRCLE. . 107.2.1.2 ADDITIONAL | | INFORMATION IS REQUIRED, DISCREPANCY. | | | | 6A) 3RD REQUEST. THE WIND DESIGN CRITERIA HAS BEEN | | PROVIDED AND ASSOCIATED VULT PRESSURES. PLEASE PROVIDE | | THE ASSOCIATED PRESSURES IN VASD SINCE THE PRODUCT | | APPROVALS HAVE ALL BEEN TESTED IN VASD AND RECORDED | | RESULT ARE IN VASD. 1609.3.1 WIND SPEED CONVERSION VULT | | TO VASD. | | | | 6B) 3RD REQUEST. IF WINDOWS AND DOORS ARE TO BE | | REPLACED PLEASE SHOW COMPLIANCE WITH: 2017 FBC-B | | 1609.1.2 PROTECTION OF OPENINGS, 1609.6.4.4.1 | | COMPONENTS & CLADDING. FLORIDA DEPARTMENT OF COMMUNITY | | AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, RULE 9N-3 | | NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS OR | | CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS: | | (31)(A) EXTERIOR DOORS, MULLIONS & ROOF HATCHES. | | (B) WINDOWS & MULLIONS | | (E) SHUTTERS | | | | 6C) 3RD REQUEST. IDENTIFY GLAZING/ MULLIONS. THE | | SUBMITTED PRODUCT APPROVALS THE ELEMENTS LISTED BELOW | | ARE NOT IDENTIFIED. PLEASE IDENTIFY ON THE PRODUCT | | APPROVAL BEFORE SUBMITTING TO DESIGNER OF RECORD AND | | BEFORE SUBMISSION TO THE BUILDING DEPARTMENT. FOR ALL | | PRODUCTS WITH GLAZING, PLEASE IDENTIFY THE OPENING | | WIDTH & HEIGHT, TYPE OF GLAZING, MULLION SIZE, LENGTH | | IF UNREINFORCED OR REINFORCED INFORMATION IF REQUIRED, | | ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH OPENING | | SIZE. 2017 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND | | DOORS SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED | | MANUFACTURER?S INSTRUCTIONS. FASTENER SIZE AND SPACING | | SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE | | CALCULATED BASED ON MAXIMUM LOADS AND SPACING USED IN | | THE TESTS. | | | | 6D)3RD REQUEST. W. P. B. 107.3.4. PRODUCT APPROVALS. | | THOSE PRODUCTS WHICH ARE REGULATED BY FLORIDA | | ADMINISTRATIVE CODE RULE 61G20 SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO | | SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2019-12-17 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2019-12-17 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2019-12-17 |
Time |
13:33 |
Sent To |
|
|
Notes |
2019-12-17 14:54:21 | 2017 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 19040094 | | ADD: 905 9TH ST. / PCN: 74-43-43-16-01-140-0130 | | CONT: SUNRISE CITY | | TEL: 561-350-5866 | | E-MAIL: [email protected] | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: TUES. DEC. 17/2019 | | ACTION: DENIED | | | | 1-6) SEMI- COMPLIED. THIS IS THE 1ST REVIEW WITH A SET | | OF PLANS THAT ARE ORIGINAL SIGNED AND SEALED PLANS. | | THE SHEET A-0.3 INDICATES BETWEEN THE R2 OCCUPANCIES | | THERE IS A ONE HOUR FIRE RATED WALL ALL THE WAY TO THE | | ROOF DECK. THE PLANS ARE SILENT AS TO WHAT MATERIALS | | ARE GOING TO MAKE UP THE ONE HOUR FIRE RATING. SHEET | | A-3.1 INDICATES THE TENANT SEPARATION WALLS WITH A WALL | | TYPE IDENTIFICATION TAG, (F) 1 5/8 METAL FURRING. | | PLEASE PROVIDE EITHER A UL WALL LISTING AND SHOW THE | | WALL COMPONENTS OR GYPSUM ASSOCIATION WALL LISTING AND | | THEIR COMPONENTS AND HOURLY FIRE RATING. PLEASE SHOW | | COMPLIANCE WITH THE 2017 FBC-B SECTION 420.2 SEPARATION | | WALLS/ FIRE PARTITIONS. THE COMMON WALL BETWEEN THE R-2 | | UNITS NEEDS TO SHOW COMPLIANCE WITH THE 2017 FBC-B | | SECTION 708, FIRE PARTITIONS. PLEASE SHOW COMPLIANCE | | WITH 2017 FBC-B SECTION: | | 708.3 FIRE-RESISTANCE RATING. FIRE PARTITIONS SHALL | | HAVE A FIRE-RESISTANCE RATING OF NOT LESS THAN 1 HOUR. | | 708.4 CONTINUITY. FIRE PARTITIONS SHALL EXTEND FROM THE | | TOP OF THE FOUNDATION OR FLOOR/CEILING ASSEMBLY BELOW | | TO THE UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, SLAB | | OR DECK ABOVE OR TO THE FIRE-RESISTANCE-RATED | | FLOOR/CEILING OR ROOF/CEILING ASSEMBLY ABOVE, AND SHALL | | BE SECURELY ATTACHED THERETO. | | | | 6) THERE SEEMS TO BE A DISCREPANCY WITHIN THE SET OF | | PLANS. SHEET A-0.4 THE DEMO PLAN STATES ALL EXTERIOR | | WINDOWS AND DOORS TO REMAIN. WHEREAS SHEET A-3.2 NOTE # | | 2 IN THE LOWER LEFT HAND CORNER OF THE SHEET INDICATES | | THE EXISTING WINDOWS AND DOORS ARE TO BE REPLACED. | | 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED, | | DISCREPANCY. | | | | 6A) THE WIND DESIGN CRITERIA HAS BEEN PROVIDED AND | | ASSOCIATED VULT PRESSURES. PLEASE PROVIDE THE | | ASSOCIATED PRESSURES IN VASD SINCE THE PRODUCT | | APPROVALS HAVE ALL BEEN TESTED IN VASD AND RECORDED | | RESULT ARE IN VASD. 1609.3.1 WIND SPEED CONVERSION VULT | | TO VASD. | | | | 6B) IF WINDOWS AND DOORS ARE TO BE REPLACED PLEASE SHOW | | COMPLIANCE WITH: 2017 FBC-B 1609.1.2 PROTECTION OF | | OPENINGS, 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA | | DEPARTMENT OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE | | 61G20-3.005, RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY | | OF PRODUCTS OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE | | PRODUCT APPROVALS: | | (31)(A) EXTERIOR DOORS, MULLIONS & ROOF HATCHES. | | (B) WINDOWS & MULLIONS | | (E) SHUTTERS | | | | 6C) IDENTIFY GLAZING/ MULLIONS. THE SUBMITTED PRODUCT | | APPROVALS THE ELEMENTS LISTED BELOW ARE NOT IDENTIFIED. | | PLEASE IDENTIFY ON THE PRODUCT APPROVAL BEFORE | | SUBMITTING TO DESIGNER OF RECORD AND BEFORE SUBMISSION | | TO THE BUILDING DEPARTMENT. FOR ALL PRODUCTS WITH | | GLAZING, PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, | | TYPE OF GLAZING, MULLION SIZE, LENGTH IF UNREINFORCED | | OR REINFORCED INFORMATION IF REQUIRED, ATTACHMENTS AND | | ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2017 FBC-B | | 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL BE | | INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER?S | | INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE | | PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED | | BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS. | | | | 6D) W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE | | 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-04-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2019-04-30 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2019-04-30 |
Time |
08:33 |
Sent To |
|
|
Notes |
2019-04-30 08:59:07 | 2017 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 19040094 | | ADD: 905 9TH ST. / PCN: 74-43-43-16-01-140-0130 | | CONT: SUNRISE CITY | | TEL: 561-350-5866 | | E-MAIL: [email protected] | | | | 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: TUES. APRIL 30/2019 | | ACTION: DENIED | | | | 1) THE SUBMITTED PLANS ARE COPIES NOT ORIGINAL PLANS, | | COPYRIGHT LAWS PROHIBIT THE COPYING OF PLANS AND TAKING | | OWNERSHIP AS YOUR OWN. PLAN IS CONSTITUTED BY 1 SHEET. | | THE MECHANICAL CONTRACTOR TOKE OWNERSHIP OF 1 PLAN BY | | SIGNING PLAN AND COMPANY LICENSE NUMBER, THE OTHER THE | | ELECTRICAL CONTRACTOR TOOK OWNERSHIP OF THE SAME COPIED | | PLAN SIGNED PLAN AND COMPANY LICENSE NUMBER. | | THE BUILDING CONTRACTOR SUNRISE CITY DID NOT SUBMIT ANY | | PLANS. | | 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | CODE, CHAPTER 1, ADMINISTRATION 107.2.1.3 QUALITY OF | | BUILDING PLANS. BUILDING PLANS SHALL BE DRAWN TO A | | MINIMUM 1/8 INCH SCALE UPON SUBSTANTIAL PAPER, CLOTH OR | | OTHER ACCEPTABLE MEDIUM. THE BUILDING OFFICIAL MAY | | ESTABLISH THROUGH DEPARTMENTAL POLICY, OTHER STANDARDS | | FOR PLANS AND SPECIFICATIONS, IN ORDER TO PROVIDE | | CONFORMITY TO ITS RECORD RETENTION PROGRAM. THIS POLICY | | MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, SHAPE, | | CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO RECORDS | | MANAGEMENT. ELECTRONIC MEDIA MUST BE COMPATIBLE WITH | | THE ARCHIVE REQUIREMENTS OF FLORIDA STATUTES. | | 2) 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. | | 107.3.5.1 COMMERCIAL BUILDINGS: | | 107.3.5.1.1 BUILDING | | 2. OCCUPANCY GROUP AND SPECIAL OCCUPANCY REQUIREMENTS | | SHALL BE DETERMINED. | | 3. MINIMUM TYPE OF CONSTRUCTION SHALL BE DETERMINED | | (SEE SECTION 503). | | | | 3) FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL | | INCLUDE THE FOLLOWING COMPONENTS: | | FIRE-RESISTANT SEPARATIONS | | FIRE-RESISTANT PROTECTION FOR TYPE OF CONSTRUCTION | | PROTECTION OF OPENINGS AND PENETRATIONS OF RATED WALLS | | FIRE BLOCKING AND DRAFT STOPPING AND CALCULATED FIRE | | RESISTANCE | | | | 4) 5. FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: | | SCHEMATIC FIRE SPRINKLERS / PRE-ENGINEERED SYSTEMS | | | | 5) 7. OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | OCCUPANCY LOAD | | GROSS | | NET | | MEANS OF EGRESS | | EXIT ACCESS | | EXIT | | EXIT DISCHARGE | | DOORS | | EMERGENCY LIGHTING AND EXIT SIGNS | | CONSTRUCTION REQUIREMENTS | | | | 6) 8. STRUCTURAL REQUIREMENTS SHALL INCLUDE: | | DESIGN LOADS | | WIND REQUIREMENTS | | BUILDING ENVELOPE | | 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | APPROVALS: | | (31)(A) EXTERIOR DOORS, MULLIONS & ROOF HATCHES. | | (B) WINDOWS & MULLIONS | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | LOUVERS, EFIS SYSTEMS, | | (D) ROOFING PRODUCTS AND ASSEMBLIES, LIGHTWEIGHT | | CONCRETE INSULATION, ROOF TOP VENTILATORS | | (E) SHUTTERS | | (F) SKYLIGHTS | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | STANDS | | | | W. P. B. 107.3.4. PRODUCT APPROVALS. THOSE PRODUCTS | | WHICH ARE REGULATED BY FLORIDA ADMINISTRATIVE CODE RULE | | 61G20 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL. | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | SHOP DRAWINGS ETC.. | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE | | THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED | | DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE | | MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS | | AND INFORMATION LACKING UNDER THE PRIOR REVIEW. | | | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2021-02-08 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-02-08 |
Time |
16:57 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-02-08 |
Time |
16:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2020-08-14 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-08-14 |
Time |
17:07 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-08-14 |
Time |
17:04 |
Sent To |
|
|
Notes |
2020-08-14 17:08:27 | SEE REVIEW COMMENTS FROM 12/22/19 JLEAHY |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2019-12-22 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-12-22 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-12-22 |
Time |
11:22 |
Sent To |
|
|
Notes |
2019-12-22 10:22:51 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | BE ADVISED THAT THE CURRENT PLAN IS SUBSTANTIALLY | | LACKING OF INFORMATION. THEREFORE, THERE MAY BE | | ADDITIONAL COMMENTS FOR SECOND REVIEW THAT ARE NOT | | ADDRESSED IN THIS REVIEW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. CORRECTED. | | 2. CORRECTED, BUT FURTHER CORRECTIONS NEEDED BASED ON | | SUBMISSION, SEE NEW COMMENTS BELOW. | | 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. NEC 215.2, 220, 408.30 (LOAD CALCULATION | | IS NOT ACCURATE AND DOES NOT INCLUDE ALL EQUIPMENT. | | FURTHERMORE, THE AMOUNT OF VA SPECIFIED FOR MANY OF THE | | ITEMS DOES NOT CORRESPOND TO KNOW VALUES. PROVIDE | | CORRECTIONS AND MANUFACTURERES SPECIFICATION FOR | | EQUIPMENT.) | | 4. PROVIDE PANEL SCHEDULE FOR EACH PANEL INDICATING ANY | | NEW OR ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE FOR | | THESE CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE | | APPLICABLE TO COMPLY WITH CODE. NEC 210.8, 210.12, | | 210.19, 210.20, 215.5, 408.4 (ONLY ONE PANEL IS SHOWN | | IN RISER DIAGRAM, BUT IS IS NOT POSSIBLE TO HAVE THE | | CIRCUITS FOR ALL THREE UNITS IN THIS ONE PANEL. | | ADDITIONALLY, EACH OCCUPANT SHALL HAVE READY ACCESS TO | | ALL OVERCURRENT DEVICES PROTECTING THE CONDUCTORS | | SUPPLYING THAT OCCUPANCY. PROVIDE CORRECTION. NEC | | 240.24(B)) | | 5. PLAN SEEMS TO INDICATE THERE WILL BE A NEW | | ELECTRICAL SERVICE. PROVIDE AVAILABLE SHORT CIRCUIT | | CALCULATION FOR SERVICE INCLUDING INFORMATION FROM THE | | POWER COMPANY STATING WHAT THE AVAILABLE SHORT CIRCUIT | | CURRENT IS FOR THE SERVICE TO CONFIRM THE STATED AIC | | RATING OF THE SERVICE EQUIPMENT IS ADEQUATE. PROVIDE | | AIC RATING OF ALL ELECTRICAL SERVICE EQUIPMENT AND | | PANELS. NEC 110.3, 110.9, 110.10 (PLAN STATED NEW METER | | AND NEW PANEL. PROVIDE AS PREVIOUSLY REQUESTED.) | | 6. CORRECTED. | | | | NEW COMMENTS: | | | | 7. PROVIDE ACCURATE RISER DIAGRAM THAT IS CODE | | COMPLIANT, SHOWING ALL DETAILS OF SERVICE EQUIPMENT, | | UNDERGROUND OR OVERHEAD SERVICE, WIRE AND BREAKER SIZES | | FOR SERVICE AND FEED TO ANY SUB-PANEL(S). SHOW GEC SIZE | | AND SYSTEM, SHOW INTERSYSTEM BONDING TERMINATION POINT. | | THE RISER DIAGRAM SHOULD REFLECT THE REQUIRED PANEL TO | | EACH TENANT SPACE. ONLY ONE SERVICE IS PERMITTED BASED | | ON LOAD, BUT ADDITIONAL METERS FOR EACH UNIT ARE | | PERMITTED IF SO DESIRED. NEC 215.5, 230.2, 250.50, | | 250.94, 408.30 | | 8. SHOW LOCATION OF ELECTRICAL SERVICE AND ANY | | ELECTRICAL PANELS ON PLAN. WPB FBC 107.2.1 | | 9. A MINIMUM OF TWO SMALL APPLIANCE BRANCH CIRCUITS ARE | | REQUIRED FOR RECEPTACLE OUTLETS THAT FEED THE KICHEN | | COUNTER SPACE IN EACH UNIT. PROVIDE CORRECTION. NEC | | 210.11, 210.52 | | 10. A MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT SHALL BE | | PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S) IN | | EACH UNIT. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. | | PROVIDE CORRECTION. NEC 210.11(C)(3), 210.52 | | 11. PROVIDE GFCI PROTECTED RECEPTACLE OUTLET FOR | | SERVICING OF A/C EQUIPMENT WITHIN 25 FEET OF THE | | EQUIPMENT PER CODE. NEC 210.63 | | 12. AFCI PROTECTION AS SHOWN IN NOTE 2 IS NOT CODE | | COMPLIANT. ALL BRANCH CIRCUITS THAT SUPPLY 120-VOLT, | | SINGLE-PHASE, 15- AND 20-AMPERE OUTLETS INSTALLED IN | | KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, | | PARLORS, LIBRARIES, DENS, BEDROOMS, SUN-ROOMS, | | RECREATIONS ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS AND | | SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED. THIS | | INCLUDES LIGHTING AND POWER OUTLETS AND RECEPTACLES. | | SOME AREAS REQUIRE BOTH AFCI AND GFCI PROTECTION. | | PROVIDE CORRECTION. NEC 210.8, 210.12; FBC RE E3902; | | FBC EX 607.1.1 OR 801.1, 801.2, OR 901.2 AS APPLICABLE. | | 13. NOTE 6 QUOTES THE 2011 NEC FOR COMPLIANCE OF TAMPER | | RESISTANT RECEPTACLES. THE 2011 NEC IS NOT THE CURRENT | | CODE. THIS NOTE ALSO QUOTES THE WRONG CODE SECTION, | | 406.10, WHICH DOES NOT APPLY. PROVIDE CORRECTIONS. FBC | | PREFACE. NEC 406.12 | | 14. NOTES 3, 4, AND 5 SPECIFY SMOKE ALARMS, BUT NONE | | ARE SHOWN ON PLAN. PROVIDE SMOKE/CO ALARMS IN EACH | | LOCATION REQUIRED PER CODE TO CONFIRM COMPLIANCE. FBC | | RE R314.3, R315.1; WPB FBC 107.2.1 | | 15. SEVERAL AREAS DO NOT COMPLY WITH THE WALL SPACING | | REQUIREMENTS FOR OUTLETS. RECEPTACLES SHALL BE | | INSTALLED SO THAT NO POINT MEASURED HORIZONTALLY ALONG | | THE FLOOR LINE OF ANY WALL SPACE IS MORE THAN 6 FEET | | FROM A RECEPTACLE OUTLET. THE WALL SPACING REQUIREMENTS | | FOR KITCHEN COUNTER SPACE STATE THAT RECEPTACLE OUTLETS | | SHALL BE INSTALLED SO THAT NO POINT ALONG THE WALL LINE | | IS MORE THAN 24 INCHES MEASURED HORIZONTALLY FROM A | | RECEPTACLE OUTLET IN THAT SPACE. THE PLAN PROVIDED DOES | | NOT MEET THIS CODE IN SOME AREAS. PROVIDE CORRECTION. | | NEC 210.52(C)(1); FBC RE E3901 | | 16. PANEL SCHEDULE SHOWS A GARAGE DOOR CIRCUIT, AND A | | CIRCUIT FOR LIFT STATION. THESE ARE NOT SHOWN ON PLAN | | ANYWHERE. PROVIDE CLARIFICATION AND/OR CORRECTIONS AS | | NEEDED. WPB FBC 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-04-23 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-04-23 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-04-23 |
Time |
15:01 |
Sent To |
|
|
Notes |
2019-04-23 15:52:08 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | BE ADVISED THAT THE CURRENT PLAN IS SUBSTANTIALLY | | LACKING OF INFORMATION. THEREFORE, THERE MAY BE | | ADDITIONAL COMMENTS FOR SECOND REVIEW THAT ARE NOT | | ADDRESSED IN THIS REVIEW. | | | | 1. PROVIDE COMPLETE ELECTRICAL PLAN FOR REVIEW, | | DETAILING ALL WORK AS DESCRIBED IN PROVIDED CONTRACT. | | PLAN IS REQUIRED TO BE SIGNED AND SEALED BY A LICENSED | | DESIGN PROFESSIONAL OR SIGNED BY THE ELECTRICAL | | CONTRACTOR QUALIFIER. FS 471.003(2)(H); 471.025; WPB | | FBC 107.2.1, 107.3.5 | | 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | 250.50, 250.94, 408.30 | | 3. PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE | | EXISTING AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE | | IS ADEQUATE. NEC 215.2, 220, 408.30 | | 4. PROVIDE PANEL SCHEDULE FOR EACH PANEL INDICATING ANY | | NEW OR ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE FOR | | THESE CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE | | APPLICABLE TO COMPLY WITH CODE. NEC 210.8, 210.12, | | 210.19, 210.20, 215.5, 408.4 | | 5. PLAN SEEMS TO INDICATE THERE WILL BE A NEW | | ELECTRICAL SERVICE. PROVIDE AVAILABLE SHORT CIRCUIT | | CALCULATION FOR SERVICE INCLUDING INFORMATION FROM THE | | POWER COMPANY STATING WHAT THE AVAILABLE SHORT CIRCUIT | | CURRENT IS FOR THE SERVICE TO CONFIRM THE STATED AIC | | RATING OF THE SERVICE EQUIPMENT IS ADEQUATE. PROVIDE | | AIC RATING OF ALL ELECTRICAL SERVICE EQUIPMENT AND | | PANELS. NEC 110.3, 110.9, 110.10 | | 6. THE WEST PALM BEACH AMENDMENTS TO THE FBC 2017 6TH | | ED, CHAPTER 1, STATE THE FOLLOWING: QUALITY OF BUILDING | | PLANS. BUILDING PLANS SHALL BE DRAWN TO A MINIMUM 1/8 | | INCH SCALE UPON SUBSTANTIAL PAPER, CLOTH OR OTHER | | ACCEPTABLE MEDIUM. THE BUILDING OFFICIAL MAY ESTABLISH | | THROUGH DEPARTMENTAL POLICY, OTHER STANDARDS FOR PLANS | | AND SPECIFICATIONS, IN ORDER TO PROVIDE CONFORMITY TO | | ITS RECORD RETENTION PROGRAM. THIS POLICY MAY INCLUDE | | SUCH THINGS AS MINIMUM SIZE, SHAPE, CONTRAST, CLARITY, | | OR OTHER ITEMS RELATED TO RECORDS MANAGEMENT. PROVIDE | | PLANS PER THIS REQUIREMENT. WPB FBC 107.2.1.3 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2020-08-06 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2020-08-06 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2020-08-06 |
Time |
08:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2019-12-09 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-12-09 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-12-09 |
Time |
13:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2019-04-09 |
|
|
Cont ID |
|
Sent By |
scaldero |
Date |
2019-04-09 |
Time |
12:00 |
Rev Time |
0.00 |
Received By |
scaldero |
Date |
2019-04-09 |
Time |
11:53 |
Sent To |
|
|
Notes |
2019-04-09 12:00:01 | PERMIT # 19040094 | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | FAIL COMMENTS: | | | | 1) SCOPE OF WORK INCLUDES INSTALL DRYWALL, INTERIOR | | DOORS, KITCHEN AND BATHROOM CABINETS, SINKS, TOILETS, | | WATER HEATER, FLOORING , AS WELL AS ELECTRICAL | | UPGRADES. THE PLAN PROVIDED DOES NOT ACCURATELY | | REPRESENT THE SCOPE OF WORK AND APPEARS TO ONLY | | INDENTIFY SOME OF THE ELECTRICAL WORK. | | PROVIDE PLANS THAT FULLY SHOW THE SCOPE OF WORK, | | RENOVATIONS, AND UPGRADES. | | | | 2) PROVIDE A LIFE SAFETY PLAN SHOWING ALL OCCUPANCY | | TYPES, OCCUPANT LOADS, FIRE RATED WALLS, EXIT SIGNS, | | EMERGENCY LIGHTING, TRAVEL DISTANCES, COMMON PATH OF | | TRAVEL ETC. | | | | 3) PROVIDE DRAWING NOTE INDICATING ALL CONSTRUCTION AND | | DEMOLITION WORK SHALL CONFORM TO THE REQUIREMENTS OF | | NFPA 241. TRASH AND CONSTRUCTION DEBRIS SHALL BE | | REMOVED FROM THE SITE DAILY. SMOKING SHALL BE | | PROHIBITED EXCEPT IN DESIGNATED EXTERIOR AREAS. ALL | | OTHER DEMOLITION OR CONSTRUCTION AREAS SHALL HAVE "NO | | SMOKING" SIGNS POSTED. WHERE SMOKING IS PERMITTED, SAFE | | RECEPTACLES FOR SMOKING MATERIALS SHALL BE PROVIDED. | | | | 4) PROVIDE DRAWING NOTE INDICATING, ?FIRE PROTECTION | | SYSTEMS SHALL REMAIN ACTIVE DURING DEMOLITION AND | | RENOVATION ACTIVITIES. IN THE EVENT A FIRE PROTECTION | | SYSTEM IS OUT OF SERVICE FOR MORE THAN 4-HOURS IN A | | 24-HOUR PERIOD, THE BUILDING SHALL BE PLACED UNDER A | | FIRE WATCH. ALL FIRE WATCH REQUESTS MUST BE SUBMITTED | | BY EMAIL ([email protected]) OR IN WRITING (FAX: | | 561-804-4774) AND APPROVED BY THE OFFICE OF THE FIRE | | MARSHAL LOCATED AT 500 NORTH DIXIE HIGHWAY.? | | | | 5) SEPARATE PLANS AND PERMITS ARE REQUIRED FOR THE | | INSTALLATION OR MODIFICATION OF THE FIRE SPRINKLER | | SYSTEM AND/OR FIRE ALARM SYSTEM, WHERE APPLICABLE. | | | | 6) WORK SHALL COMPLY WITH THE 6TH EDITION OF THE | | FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE 2015 | | EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA | | AMENDMENTS. | | | | | | | | SUE ELLEN CALDERON | | ASSISTANT FIRE MARSHAL | | [email protected] | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2021-02-22 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2021-02-18 |
Time |
11:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2021-02-08 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2021-02-08 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2021-01-29 |
Time |
08:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2020-08-14 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2020-08-14 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2020-07-29 |
Time |
09:23 |
Sent To |
|
|
Notes |
2020-08-05 17:42:30 | 08/05/2020 CONVERTED TO DIGITAL. JG. | | | 2020-07-28 07:54:23 | ROUTED TO B22 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-12-23 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-12-23 |
Time |
16:06 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-12-03 |
Time |
15:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-04-30 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-04-02 |
Time |
15:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2019-04-30 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2019-04-30 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2019-04-30 |
Time |
08:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2021-02-02 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2021-02-02 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2021-02-02 |
Time |
15:10 |
Sent To |
|
|
Notes |
2021-02-02 15:11:31 | MECHANICAL PASSED WITH PRIVISO: | | DRYER INSTALLATION MUST MEET FBC M 504 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2020-08-07 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2020-08-07 |
Time |
07:56 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2020-08-07 |
Time |
07:54 |
Sent To |
|
|
Notes |
2020-08-07 07:55:58 | PLEASE PROVIDE THE INFORMATION THAT WAS REQUESTED IN | | THE 2ND CYCLE REVIEW. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2019-12-23 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-12-23 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-12-23 |
Time |
09:29 |
Sent To |
|
|
Notes |
2019-12-23 09:41:10 | 2ND REVIEW FBC-2017 MECHANICAL | | PERMIT #19040094 | | 12/23/19 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | COMMENTS FROM THE 1ST REVIEW ARE LISTED BELOW STILL | | EXIST. | | | | 1) THE MECHANICAL PLANS FOR THE NEW AC SYSTEMS ARE | | INCOMPLETE- SECTION 107.2.1 WPB. PLEASE PROVIDE: | | | | A) DUCT LAYOUT PLANS FOR EACH OF THE THREE APARTMENTS- | | SECTION 603 FBC M. (INCOMPLETE AC PLANS HAVE BEEN | | SUBMITTED. PROVIDE- AC EQUIPMENT SCHEDULES ON THE | | PLANS, SHOW THE SUPPLY CFMS AT EACH DIFFUSER, AND SHOW | | RETURN AIR FROM THE BEDROOMS. | | B) AC COOLING AND HEATING CALCULATIONS FOR THE NEW | | SYSTEMS- SECTION R503.2 FBC EC. (NOT PROVIDED) | | C) ENERGY CALCULATIONS FOR THE NEW CONDITIONED SPACES- | | SECTION R403.6.1 FBC EC. (NOT PROVIDED) | | D) VENTILATION CALCULATIONS PER TABLE 403.3.1.1 FOR | | EACH APARTMENT, AND INDICATE HOW OUTDOOR AIR IS BEING | | PROVIDED AND AUTOMATICALLY CONTROLLED- SECTION | | C403.2.4.3 FBC EC. (NOT PROVIDED) | | D) EXTERIOR CONDENSER MOUNTING DETAILS- SECTION 301.15 | | FBC M. (OK) | | E) CONDENSATE DISPOSAL PLANS- SECTION 307.2.1 FBC M. | | (NOT PROVIDED) | | | | 2) PLEASE NOTE THAT LOUVERED AC CLOSET DOORS USED FOR | | RETURN AIR SHALL BE NON-COMBUSTIBLE PER SECTION 602 FBC | | M. (OK) | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2019-04-19 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-04-19 |
Time |
07:52 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-04-19 |
Time |
07:12 |
Sent To |
|
|
Notes |
2019-04-19 08:26:05 | 1ST REVIEW FBC-2017 MECHANICAL | | PERMIT #19040094 | | 4/19/19 | | | | CODES IN EFFECT: | | | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE MECHANICAL PLANS FOR THE NEW AC SYSTEMS ARE | | INCOMPLETE- SECTION 107.2.1 WPB. PLEASE PROVIDE: | | | | A) DUCT LAYOUT PLANS FOR EACH OF THE THREE APARTMENTS- | | SECTION 603 FBC M. | | B) AC COOLING AND HEATING CALCULATIONS FOR THE NEW | | SYSTEMS- SECTION R503.2 FBC EC | | C) ENERGY CALCULATIONS FOR THE NEW CONDITIONED SPACES- | | SECTION R403.6.1 FBC EC. | | D) VENTILATION CALCULATIONS PER TABLE 403.3.1.1 FOR | | EACH APARTMENT, AND INDICATE HOW OUTDOOR AIR IS BEING | | PROVIDED AND AUTOMATICALLY CONTROLLED- SECTION | | C403.2.4.3 FBC EC. | | D) EXTERIOR CONDENSER MOUNTING DETAILS- SECTION 301.15 | | FBC M | | E) CONDENSATE DISPOSAL PLANS- SECTION 307.2.1 FBC M. | | | | 2) PLEASE NOTE THAT LOUVERED AC CLOSET DOORS USED FOR | | RETURN AIR SHALL BE NON-COMBUSTIBLE PER SECTION 602 FBC | | M. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | KEEP THEM WITH THE SUBMITTALS | | | | CHRISTOPHER L. COLE | | MECHANICAL PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2021-02-22 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-02-22 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-02-22 |
Time |
07:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2021-02-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-02-08 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-02-08 |
Time |
10:07 |
Sent To |
|
|
Notes |
2021-02-08 11:19:25 | 4TH REVIEW FBC-2017 PLUMBING | | PERMIT- 19040094 | | 2/8/2021 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 | | FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 | | FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 | | FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION | | 2017 | | FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 | | FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION | | 2017 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE COD | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH | | EDITION 2017 | | | | PLAN REVIEW RESULTS: DENIED. | | COMMENTS FROM THE 3RD REVIEW LISTED BELOW ARE MARKED AS | | PASSED OR FAILED. NOTES IN CAP LETTERS HAVE BEEN ADDED | | TO FAILED COMMENTS. | | | | 1) FAILED. INDICATE ON THE PLANS IF THE NEW STACKABLE | | WASHER/DRYER IS CONNECTING TO EXISTING WATER AND DRAIN | | LINES. IF NEW WATER AND DRAIN LINES ARE BEING | | INSTALLED, SUBMIT A SANITARY AND WATER RISER DIAGRAM | | THAT CLEARLY REFLECTS THE SCOPE OF THE PLUMBING WORK TO | | BE DONE. WPB AMEND. TO FBC SEC. 107.2.1, 107.3.5.1.3. | | THE ARCHITECT'S RESPONSE TO THE COMMENT INDICATES | | SAINTARY AND WATER RISER DRAWINGS WILL BE PROVIDED ON | | SHEET P-1.1, HOWEVER THE RISERS WERE NOT PROVIDED. | | | | 2) FAILED IF A NEW DRAIN LINE IS BEING INSTALLED FOR | | THE WASHER, IT SHALL BE A MINIMUM OF 3 INCHES IN | | DIAMETER UP TO THE TRAP FOR THE WASHER STANDPIPE. | | FBC-PLUMBING SEC.406.2. SEE NOTES UNDER COMMENT #1. | | | | 3) FAILED. THE WATER HEATERS SHALL BE EQUIPPED WITH | | PROVISIONS FOR THERMAL EXPANSION PER FBC-PLUMBING | | SEC.607.3. THERMAL EXPANSION TANKS SHALL BE CONNECTED | | TO THE WATER HEATER COLD WATER SUPPLY PIPE AT A POINT | | THAT IS DOWNSTREAM OF ALL CHECK VALVES, PRESSURE | | REDUCING VALVES AND BACKFLOW PREVENTERS. THE NEW WATER | | HEATER DETAIL IS SHOWING A "THERMAL EXPANSION (RELIEF | | VALVE)" ON THE HOT WATER LINE. PLEASE REFER TO SECTIONS | | 504.4. 504.4.1 FOR RELIEF VALVE APPROVAL AND | | INSTALLATION LOCATION AND CORRECT THE PLAN. | | | | 4) PASSED. THE WATER HEATERS SHALL BE INSTALLED WITH A | | HEATER PAN AND PAN DRAIN IN ACCORDANCE WITH | | FBC-PLUMBING SEC.504.6. | | | | 5) PASSED. THE SHUTOFF VALVES FOR THE STACKABLE | | WASHER/DRYER SHALL BE PROVIDED WITH ACCESS PER | | FBC-PLUMBING SEC.606.3. | | | | 6) PASSED. PLANS SHALL BEAR THE SIGNATURE AND SEAL OF | | THE DESIGN PROFESSIONAL. FL. ADMIN. CODE RULE | | 61G1-16.001. | | | | NEW COMMENTS BASED ON RESUBMITTED PLANS. | | | | 1) P-1.1: THE PLAN AND THE ENERGY COMPLIANCE FORM | | INDICATE 30-GALLON WATER HEATERS TO BE INSTALLED, | | HOWEVER THE DETAIL INDICATES A 40-GALLON UNIT. PLEASE | | PROVIDE AN EQUIPMENT SCHEDULE ON THE PLAN LISTING THE | | MAKE, MODEL, GALLON SIZE AND EFFICIENCY RATING OF THE | | WATER HEATERS- TABLE C404.2 FBC EC. | | | | 2) P-1.1: PLEASE PROVIDE A SHOWER PAN DETAIL- SECTION | | 417.5.2 FBC P. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2020-08-11 |
|
|
Cont ID |
|
Sent By |
tklarge |
Date |
2020-08-11 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
tklarge |
Date |
2020-08-11 |
Time |
06:18 |
Sent To |
|
|
Notes |
2020-08-11 07:03:43 | 1) INDICATE ON THE PLANS IF THE NEW STACKABLE | | WASHER/DRYER IS CONNECTING TO EXISTING WATER AND DRAIN | | LINES. IF NEW WATER AND DRAIN LINES ARE BEING | | INSTALLED, SUBMIT A SANITARY AND WATER RISER DIAGRAM | | THAT CLEARLY REFLECTS THE SCOPE OF THE PLUMBING WORK TO | | BE DONE.WPB AMEND. TO FBC SEC. 107.2.1, 107.3..5.1.3. | | 2) IF A NEW DRAIN LINE IS BEING INSTALLED FOR THE | | WASHER, IT SHALL BE A MINIMUM OF 3 INCHES IN DIAMETER | | UP TO THE TRAP FOR THE WASHER STANDPIPE.FBC-PLUMBING | | SEC.406..2. | | 3) THE WATER HEATERS SHALL BE EQUIPPED WITH PROVISIONS | | FOR THERMAL EXPANSION PER FBC-PLUMBING SEC.607.3. | | 4) THE WATER HEATERS SHALL BE INSTALLED WITH A HEATER | | PAN AND PAN DRAIN IN ACCORDANCE WITH FBC-PLUMBING | | SEC.504.6. | | 5) THE SSHUTOFF VALVES FOR THE STACKABLE WASHER/DRYER | | SHALL BE PROVIDED WITH ACCESS PER FBC-PLUMBING | | SEC.606.3. | | 6) PLANS SHALL BEAR THE SIGNATURE AND SEAL OF THE | | DESIGN PROFESSIONAL. FL. ADMIN. CODE RULE 61G1-16.001. | | | | TIM LARGE | | CHIEF PLUMBING INSPECTOR | | PLUMBING PLAN REVIEW | | 561-805-6692 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2019-12-23 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-12-23 |
Time |
15:52 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-12-23 |
Time |
13:16 |
Sent To |
|
|
Notes |
2019-12-23 16:06:32 | 1ST REVIEW: | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | PLUMBING COMMENTS: | | | | 1. PROVIDE SANITARY RISER FOR THE NEW STACKABLE WASHER | | IT SHALL CONNECT TO BUILDING DRAIN DOWN STREAM OF THE | | BATHROOM GROUP. PER WPB AMEND TO FBC 107.2.1 AND FBC PL | | 912.1 | | | | 2. THE SHUT OFF VALVE FOR THE STACKABLE WASHERS SHALL | | BE ACCESSIBLE WITHOUT MOVING THE APPLIANCES. PER FBC PL | | 606.3 | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-04-18 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2019-04-18 |
Time |
10:39 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2019-04-18 |
Time |
09:47 |
Sent To |
|
|
Notes |
2019-04-18 10:39:48 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | WPB CCC = WEST PALM BEACH CROSS CONNECTION CONTROL | | MANUAL | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | EDITION | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 1ST REVIEW | | PLUMBING COMMENTS: DENIED | | 1. PLUMBING REVIEW CONDUCTED IN ACCORDANCE WITH WPB FBC | | 107.3.5.1.3 | | 2. PER WPB FBC 107.2.1, PROVIDE THE BUILDING | | CLASSIFICATION/OCCUPANCY AS PRESCRIBED IN FBC CHAPTER 3 | | AND OCCUPANT LOAD CALCULATIONS IN ACCORDANCE WITH FBC | | 1004 AND 1005. | | 3. CONTINGENT UPON THE DETERMINATION OF THE BUILDING | | CLASSIFICATION/OCCUPANCY, CLOTHES WASHER FACILITIES | | WILL BE REQUIRED IN ACCORDANCE WITH FBC PL TABLE 403.1. | | 4. PER WPB FBC 107.2.1, PROVIDE DEDICATED PLUMBING | | FLOOR PLAN NOTING A COMPLETE SCOPE OF WORK; INDICATE ON | | THE PLAN PLUMBING FIXTURES, WATER HEATERS AND | | APPLIANCES TO BE REPLACED. ADDITIONALLY, INDICATE ON | | THE PLANS TUB/SHOWER VALVE REPLACEMENT. PROVIDE NOTE ON | | THE PLAN CONFIRMING THAT ROUGH/TOP OUT WORK WILL BE | | LIMITED TO IN WALL REPLACEMENT OF TUB SHOWER VALVES AND | | PROVISION FOR WATER HAMMER ARRESTORS FOR CLOTHES | | WASHERS (SEE NOTE 2); IF THERE IS TO BE MORE EXTENSIVE | | ROUGH/TOP OUT WORK, THEN IT SHALL BE INDICATED ON THE | | PLANS. THE PLAN SHALL BE CLEAR AND LEGIBLE AND COMPLY | | WITH WPB FBC 107.2.1.3. | | 5. THE PLAN SHALL BE STAMPED/SEALED AND SIGNED BY | | DESIGNER OF RECORD IN ACCORDANCE WITH FS 471 AND FAC | | 61G15. | | 6. PER WPB FBC 107.2.1, PROVIDE THE NOTE ?INDIVIDUAL | | SHOWER AND TUB-SHOWER COMBINATION VALVES SHALL BE | | BALANCED-PRESSURE, THERMOSTATIC OR COMBINATION | | BALANCED-PRESSURE/THERMOSTATIC VALVES THAT CONFORM TO | | THE REQUIREMENTS OF ASSE 1016/ASME A112.1016/CSA | | B125.16 OR ASME A112.18.1/CSA B125.1 AND SHALL BE | | INSTALLED AT THE POINT OF USE PER FBC PL 424.3.? | | 7. PROVIDE WATER HEATER SPEC WITH CAPACITY AND | | ELECTRICAL CHARACTERISTICS. ELECTRICAL CHARACTERISTICS | | SHALL MATCH ELECTRICAL PLANS. | | 8. PER WPB FBC 107.2.1, PROVIDE THE NOTE ?WATER HEATER | | INSTALLATION SHALL COMPLY WITH FBC PL CHAPTER 5 AND FBC | | PL 607.3.? | | 9. PER WPB FBC 107.2.1, PROVIDE THE NOTE ?A | | WATER-HAMMER ARRESTOR SHALL BE INSTALLED WHERE | | QUICK-CLOSING VALVES ARE UTILIZED. WATER-HAMMER | | ARRESTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE | | MANUFACTURER?S INSTRUCTIONS. WATER-HAMMER ARRESTORS | | SHALL CONFORM TO ASSE 1010 PER BY FBC PL 604.9.? | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | (STAMPED/SEALED AND SIGNED BY DESIGNER OF RECORD IN | | ACCORDANCE WITH FS 471 FAC 61G15) INTO THE ORIGINAL | | SUBMITTAL AND REMOVE THE PREVIOUSLY REVIEWED SHEETS. | | ONE COPY OF THE PREVIOUSLY REVIEWED SHEETS SHOULD | | REMAIN IN PACKAGE AND BE MARKED "VOID". | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2021-02-22 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2021-02-22 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2021-02-22 |
Time |
07:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2021-02-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2021-02-02 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2020-08-05 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2020-08-05 |
Time |
17:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2020-08-05 |
Time |
17:43 |
Sent To |
|
|
Notes |
2020-08-05 17:46:23 | CONVERTED TO DIGITAL. | | ARCHITECT'S DRAWINGS WITH ORIGINAL SEAL AND SIGNATURE | | SENT TO TEMP. STORAGE (PENDING LAST REVIEW). JG. | | |
|
|
|