Plan Review Details - Permit 19031246
Plan Review Stops For Permit 19031246 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2019-05-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-05-30 |
Time |
07:28 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-05-30 |
Time |
07:28 |
Sent To |
|
|
Notes |
2019-05-30 07:33:22 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | CONSTRUCTION TRAILER BUILDING REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | COMMENT FROM FIRST REVIEW: | | | | 1- CONTRACTOR TO PROVIDE LETTER STATING IF THE | | STRUCTURE IS A TEMPORARY STRUCTURE USED EXCLUSIVELY FOR | | CONSTRUCTION PURPOSES. AND STATE IF MEETINGS ARE | | GOING-TO TAKE PLACE IN THE CONSTRUCTION TRAILER. | | DIFFERENT COMMENTS APPLY IF TEMPORARY CONSTRUCTION | | TRAILER IS NOT USED EXCLUSIVELY FOR CONSTRUCTION. | | SEC. 102.2 (EXCEPTIONS (D) AND (E) CITY AMENDMENTS. | | | | 2ND REVIEW, LETTER STATES THAT THIS IS AN OFFICE | | TRAILER, AND IS FOR MEETINGS AND PLANNING. PER BUILDING | | OFFICIAL, IF MEETINGS ARE HELD IN A TEMPORARY | | CONSTRUCTION TRAILER, IT IS SUBJECT TO FBC | | ACCESSIBILITY REQUIREMENTS. REVISE PLAN TO SHOW RAMP OR | | OTHER FORM OF VERTICAL ACCESSIBILITY, FBC A 201.3, | | 206.1. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-05-01 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-05-01 |
Time |
15:04 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-05-01 |
Time |
14:02 |
Sent To |
|
|
Notes |
2019-05-01 15:17:54 | CONSTRUCTION TRAILER BUILDING REVIEW COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | | | 1- CONTRACTOR TO PROVIDE LETTER STATING IF THE | | STRUCTURE IS A TEMPORARY STRUCTURE USED EXCLUSIVELY FOR | | CONSTRUCTION PURPOSES. AND STATE IF MEETINGS ARE | | GOING-TO TAKE PLACE IN THE CONSTRUCTION TRAILER. | | DIFFERENT COMMENTS APPLY IF TEMPORARY CONSTRUCTION | | TRAILER IS NOT USED EXCLUSIVELY FOR CONSTRUCTION. | | SEC. 102.2 (EXCEPTIONS (D) AND (E) CITY AMENDMENTS. | | | | | | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2019-05-28 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-05-28 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-05-28 |
Time |
14:14 |
Sent To |
|
|
Notes |
2019-05-28 13:16:03 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED | | SATISFACTORILY ARE MARKED AS CORRECTED. PREVIOUS | | COMMENTS THAT HAVE NOT BEEN ADDRESSED SATISFACTORILY | | HAVE ADDITIONAL COMMENTS IN PARENTHESES. ANY NEW | | COMMENTS WILL BE LISTED AFTER PREVIOUS COMMENTS. | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | SEALED BY A LICENSED DESIGN PROFESSIONAL OR SIGNED BY | | THE ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H); | | 471.025; WPB FBC 107.2.1, 107.3.5 (NO PLAN PROVIDED AS | | STATED IN RESPONSE LETTER. THIS PERMIT CANNOT BE ISSUED | | UNTIL PLAN FOR ELECTRICAL IS APPROVED.) | | 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | 250.50, 250.94, 408.30 (NO PLAN PROVIDED AS STATED IN | | RESPONSE LETTER. THIS PERMIT CANNOT BE ISSUED UNTIL | | PLAN FOR ELECTRICAL IS APPROVED.) | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-04-18 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-04-18 |
Time |
13:38 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-04-18 |
Time |
12:18 |
Sent To |
|
|
Notes |
2019-04-18 13:38:52 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW, SIGNED AND | | SEALED BY A LICENSED DESIGN PROFESSIONAL OR SIGNED BY | | THE ELECTRICAL CONTRACTOR QUALIFIER. FS 471.003(2)(H); | | 471.025; WPB FBC 107.2.1, 107.3.5 | | 2. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | 250.50, 250.94, 408.30 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2019-05-14 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-05-14 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-05-14 |
Time |
14:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2019-03-29 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-03-29 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-03-29 |
Time |
11:54 |
Sent To |
|
|
Notes |
2019-03-29 12:04:54 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | 1) THERE IS NO INDICATION OF A DIMENSION FROM THE | | NEAREST BULDING ON THE ADJACENT PROPERTY. | | | | PLEASE PROVIDE THAT DIMENSION AND ENSURE IT COMPLIES | | WITH NFPA 241 | | | | PER NFPA 241, 4.2 TEMPORARY OFFICES AND SHEDS; TABLE | | 4.2.1 SEPARATION DISTANCES, FIRE SPRINKLERS ARE | | REQUIRED IN EACH TRAILER. | | 4.2.1* SEPARATION DISTANCES BETWEEN BUILDINGS UNDER | | CONSTRUCTION AND CONSTRUCTION-RELATED STRUCTURES, SUCH | | AS TEMPORARY OFFICES, TRAILERS, SHEDS, AND OTHER | | FACILITIES FOR THE STORAGE OF TOOLS AND MATERIALS | | HAVING COMBUSTIBLE CONSTRUCTION OR CONTENTS, SHALL BE | | IN ACCORDANCE WITH TABLE 4.2.1. | | | | 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 30 FEET | | 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 35 FEET | | 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 40 FEET | | 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 45 FEET | | 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | ADJACENT STRUCTURES BY AT LEAST 50 FEET | | 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE | | SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET | | **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL | | BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | | NOTES: | | (1) WHERE THE SEPARATION DISTANCE BETWEEN TEMPORARY | | STRUCTURES IS LESS THAN THE MINIMUM SEPARATION | | DISTANCE, THEN THE EXPOSING WALL LENGTH SHALL BE | | CONSIDERED TO BE THE SUM OF THE INDIVIDUAL EXPOSING | | WALL LENGTHS OF THE TEMPORARY STRUCTURES. | | (2) A 75 PERCENT REDUCTION IN SEPARATION DISTANCES | | SHALL BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | (3) THE SEPARATION DISTANCES APPLY TO SINGLE-LEVEL | | STRUCTURES ONLY. THIS TABLE DOES NOT APPLY TO | | MULTILEVEL, UNSPRINKLERED STRUCTURES. A LEVEL, WHERE | | APPLYING THIS TABLE, IS 3600 MM (144 IN.). | | | | 4.2.2* DETACHMENT BETWEEN TEMPORARY STRUCTURES, | | ADEQUATE TEMPORARY FIXED FIRE PROTECTION SYSTEMS, AND | | PORTABLE EQUIPMENT SHALL BE PROVIDED AS REQUIRED BY THE | | AUTHORITY HAVING JURISDICTION. | | | | | | PLEASE PROVIDE THE DISTANCE WITHIN COMPPIANCE OR | | CORRECT THE LOCATION OR PROTECT WITH FIRE SPRINKLERS. | | | | | | | | | | 2) IS THIS AN OFFICE TRAILER OR CONSTRUCTION EQUIPMENT | | TRAILER? | | | | PLEASE PROVIDE DETAILS. | | | | | | | | 3) PLEASE PROVIDE FLOOR PLAN AND LOCATION OF EXIT | | DOORS, STAIRS, RAMPS, ETC. | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-05-30 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2019-05-30 |
Time |
07:35 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2019-05-08 |
Time |
10:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-05-01 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-05-01 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-03-27 |
Time |
09:21 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2019-05-16 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-05-16 |
Time |
10:28 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-05-16 |
Time |
07:50 |
Sent To |
|
|
Notes |
2019-05-16 10:30:44 | NO PLUMBING SHOWN IN TRAILER. | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-04-11 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2019-04-11 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2019-04-11 |
Time |
14:45 |
Sent To |
|
|
Notes |
2019-04-11 14:46:45 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | WPB CCC = WEST PALM BEACH CROSS CONNECTION CONTROL | | MANUAL | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION | | FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH | | EDITION | | FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION | | FBC FG = FLORIDA FUEL GAS CODE 2017 6TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 1ST REVIEW: DENIED | | PLUMBING COMMENTS: | | | | A. PER FBC 107.2.1, PROVIDE THE FOLLOWING: | | 1. PROVIDE PLAN OF ACTUAL TRAILER AND PROVIDE STATE OF | | FLORIDA CERTIFICATION. IF NO STATE CERTIFICATION THEN | | COMPLY WITH REQUIREMENTS OF FBC. | | 2. SHOW SEWER POINT OF CONNECTION FOR BUILDING | | DRAIN/SEWER | | 3. SHOW WATER SERVICE AND PROVIDE BFP TO COMPLY WITH | | WPB CROSS CONNECTION CONTROL. | | B. IF NO STATE CERTIFICATION THEN PROVIDE PLANS | | COMPLYING WITH REQUIREMENTS OF FBC. | | | | END OF COMMENTS | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, AA TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | PHONE 561-805-6715 | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2019-05-15 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2019-05-15 |
Time |
|
Rev Time |
0.00 |
Received By |
llouie |
Date |
2019-05-15 |
Time |
|
Sent To |
|
|
Notes |
2019-05-15 12:10:35 | ** ZONING APPROVED WITH THE FOLLOWING PROVISO ** | | | | 1.) CONSTRUCTION TRAILER SHALL BE SETBACK ATLEAST 5 FT. | | FROM THE PROPERTY LINES. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2019-04-10 |
|
|
Cont ID |
|
Sent By |
llouie |
Date |
2019-04-10 |
Time |
|
Rev Time |
|
Received By |
llouie |
Date |
2019-04-09 |
Time |
|
Sent To |
|
|
Notes |
2019-04-10 11:11:43 | ** FAILED ** | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | APPLICABLE: | | | | 1.) INFORMATION INDICATES THAT THE USE IS AN EXISTING | | MULTIFAMILY BUILDING WITH 12 APARTMENTS. ARE THE UNITS | | OCCUPIED? IF SO, PROPOSED TRAILER WOULD NOT BE ABLE TO | | LOCATE IN THE PARKING AREA, WHERE IT WOULD ELIMINATE | | REQUIRED PARKING SPACES FOR THE RESIDENTS. | | | | 2.) DETAILS/SPECIFICATIONS ON THE PROPOSED CONSTRUCTION | | IS MISSING FROM THE PERMIT SET. PLEASE PROVIDE. | | | | 3.) SHOW SETBACK DIMENSIONS FROM THE PROPOSED LOCATION | | OF THE TRAILER TO THE PROPERTY LINES. | | | | 4.) WILL THERE BE ANY SCREENING PROPOSED FOR THE | | CONSTRUCTION SITE? | | | | NOTES: | | | | * VALUE OF SCOPE ($2,500) DOES NOT EXCEED 50% OF THE | | VALUE OF THE STRUCTURE ACCORDING TO 2018 PAPA. | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | QUESTIONS. | | | | * ZONE: GC | | | | * REFERENCE: PRIMARY PERMIT #17101193 (STRUCTURAL | | REPAIRS DUE TO WATER DAMAGE) | | |
|
|
|