Plan Review Stops For Permit 19031191 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2019-04-10 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2019-04-10 |
Time |
13:19 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2019-04-09 |
Time |
10:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2019-04-17 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-04-17 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-04-17 |
Time |
15:47 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-04-10 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-04-10 |
Time |
08:00 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-04-10 |
Time |
07:59 |
Sent To |
|
|
Notes |
2019-04-10 07:59:55 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. NO REVISIONS SHOWN ON PLAN. CLOUD REVISIONS AND | | PROVIDE DESCRIPTION. WPB FBC 107.2.1 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2019-04-11 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-04-11 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-04-11 |
Time |
15:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2019-03-28 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2019-03-28 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2019-03-28 |
Time |
13:23 |
Sent To |
|
|
Notes |
2019-03-28 13:35:50 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | 1) SHEET A 1.2 - THERE IS AN INDICATION OF A "NEW | | SHAFT". | | | | WHAT IS THE PURPOSE OF THIS NEW SHAFT? | | | | HOW MANY FLOORS DOES IT CONNECT? | | | | PLEASE PROVIDE DETAILS | | | | | | | | 3) SHEET A 2.2 - THE DOOR TO THE SHAFT IS INDICATED HAS | | HAVING A B RATING. THERE IS NO DEFINITION OF WHAT B IS. | | | | PLEASE PROVIDE DETAILS/DEFINITION. | | | | | | | | | | 4) SHEET A 2.2 - THERE IS NO INDICATION OF THE WIDTH | | DIMENSION BETWEEN THE CORNER OF THE NEW SHAFT WALL AND | | THE EXISTING WALL. | | | | THIS DIMENSION IS REQUIREDTO MEET OR EXCEED THE | | REQUIREMENT FOR EXITING PER NFPA 101, CH 7, MEANS OF | | EGRESS. | | | | PLEASE PROVIDE THE DIMENSION AND CORRECT IR APPLICABLE. | | | | | | | | | | 5) SHEET FP - FIRE SPRINKLER PLANS ARE INDICATED. THESE | | PLANS ARE NOLY REVIEWED FOR INFORMATIONAL PURPOSES. | | | | REVISED FIRE SPRINKLED SHOP DRAWING ARE REQUIRED UNDER | | SEPARATE REVISED PERMIT. | | | | PROVIDE A NOTE OF ACKNOWLEDGEMENT. | | | | | | | | 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2019-04-18 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-04-18 |
Time |
08:01 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-04-18 |
Time |
08:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2019-04-10 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-04-10 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-04-10 |
Time |
10:10 |
Sent To |
|
|
Notes |
2019-04-10 10:10:32 | 1ST REVIEW: | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | GAS COMMENTS: | | | | 1. PROVIDE DETAIL OF HOW THE END OF THE PIPING WILL BE | | SECURED SO THAT GAS WILL NOT BE RELEASED INTO SPACE IF | | SOME ONE ENERGIZES THE 2" LINE A LOCKING VALVE AND CAP | | IS REQUIRED. PER WPB AMEND TO FBC 107.2.1 AND FBC FG | | 404.15 | | 2. PLACE NOTE ON PLAN . CITY OF WEST PALM BEACH PIPING | | AFFIDAVIT OR MANOMETER TEST DOCUMENT REQUIRED AT | | JOBSITE FOR FINAL INSPECTION. PER WPB AMEND TO FBC | | 107.2.1 | | 3. PLACE NOTE ON THE PLAN THAT PIPING IS FOR FUTURE USE | | NO APPLIANCES TO BE CONNECTED WITH OUT SEPARATE | | PERMIT.. PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-04-18 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-04-18 |
Time |
08:01 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2019-04-12 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-03-26 |
Time |
16:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2019-04-12 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2019-04-12 |
Time |
07:56 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2019-04-11 |
Time |
17:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2019-04-18 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-04-18 |
Time |
08:01 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-04-18 |
Time |
08:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-04-10 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-04-10 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-04-10 |
Time |
09:12 |
Sent To |
|
|
Notes |
2019-04-10 10:09:43 | 1ST REVIEW: | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | GAS COMMENTS: | | | | 1. PROVIDE DETAIL OF HOW THE END OF THE PIPING WILL BE | | SECURED SO THAT GAS WILL NOT BE RELEASED INTO SPACE IF | | SOME ONE ENERGIZES THE 2" LINE A LOCKING VALVE AND CAP | | IS REQUIRED. PER WPB AMEND TO FBC 107.2.1 AND FBC FG | | 404.15 | | 2. PLACE NOTE ON PLAN . CITY OF WEST PALM BEACH PIPING | | AFFIDAVIT OR MANOMETER TEST DOCUMENT REQUIRED AT | | JOBSITE FOR FINAL INSPECTION. PER WPB AMEND TO FBC | | 107.2.1 | | 3. PLACE NOTE ON THE PLAN THAT PIPING IS FOR FUTURE USE | | NO APPLIANCES TO BE CONNECTED WITH OUT SEPARATE | | PERMIT.. PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2019-04-09 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2019-04-09 |
Time |
14:17 |
Rev Time |
0.50 |
Received By |
eschneid |
Date |
2019-04-09 |
Time |
13:09 |
Sent To |
|
|
Notes |
|
|