Plan Review Details - Permit 19031028
Plan Review Stops For Permit 19031028 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2019-06-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-06-06 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-06-06 |
Time |
13:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2019-05-20 |
|
|
Cont ID |
|
Sent By |
jduprey |
Date |
2019-05-20 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
jduprey |
Date |
2019-05-17 |
Time |
14:43 |
Sent To |
|
|
Notes |
2019-05-20 09:13:55 | BUILDING PLAN REVIEW | | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | | | JOSEAN A. DUPREY | | BUILDING PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION | | TEL: 561-805-6716 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | 2ND REVIEW | | RESULTS: DENIED | | YOUR SUBMITTAL APPROVAL FOR THE SUBMITTED SCOPE OF WORK | | IS PENDING DUE FOR THE REASONS LISTED BELOW. | | | | 1. PER PALM BEACH COUNTY PROPERTY APPRAISAL WEBSITE | | THIS PROPERTY HAVE A TOTAL OF 2932 SQUARE FOOT. THE | | ENERGY CALCULATIONS WERE SUBMITTED WITH A TOTAL OF 1818 | | SQUARE FOOT AND A TOTAL OF 4 BEDROOMS, PLEASE CLARIFY. | | ALSO THE LINE ITEM NUMER 9 IS ONLY INCLUDING ONE TYPE | | OF WALL (CONCRETE BLOCK) WITH INSULATION TYPE R4.1, | | HOWEVER THE DRAWING DETAIL 3/A2.0 SHOW AN INSULATION | | TYPE R5 FOR THIS CONCRETE WALL TYPE. THE ENERGY | | CALCULATION DOCUMENT DOES NOT SHOW INSULATION | | REQUIREMENTS FOR UPPER FLOOR WOOD WALLS AS INDICATE ON | | DETAIL 3/A2.0. PLEASE CLARIFY AND RE-SUBMIT. | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2019-04-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-04-11 |
Time |
18:03 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-04-10 |
Time |
11:20 |
Sent To |
Z |
|
Notes |
2019-04-11 18:05:46 | RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | 1- PLANS SUBMITTED NEED TO HAVE THE SEAL AND SIGNATURE | | OF THE ARCHITECT OF RECORD SHOWN ON THE TITLE BLOCK | | (REGINALD ACOX & ASSOCIATES) AS REQUIRED BY CHAPTER 481 | | F.S WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORDS. | | | | 2- PLANS SUBMITTED SHOW NEW BEDROOMS AND NEW BATHROOM. | | ACCORDING TO CITY RECORDS AND PROPERTY APPRAISER THIS | | AREA WAS PERMITTED AS A GARAGE. THERE ARE NO CITY | | RECORDS FOR THE CONVERSION OF GARAGE TO BEDROOMS AND | | BATHROOM. REVISE SCOPE OF WORK ON THE PERMIT | | APPLICATION TO REFLECT THE CONVERSION OF GARAGE TO | | LIVABLE SPACE. THIS IS A CHANGE OF USE WITHOUT A CHANGE | | OF OCCUPANCY. SEC. 506 FBC-EXISTING BUILDING AND SEC. | | 1001.2.1 FBC-EXISTING BUILDING. | | | | 3- SCOPE OF WORK SHOWN ON PLANS IS NOT CLEAR. ALL THE | | WORK SHOWN ON THE EXISTENT GARAGE CONVERTED TO | | BEDROOMS/BATHROOM IS CONSIDERED TO BE NEW. CLEARLY | | DEFINE THE SCOPE OF WORK ON THE SECOND FLOOR AND ON THE | | REST OF THE HOUSE. CLEARLY IDENTIFY WHAT IS NEW, WHAT | | IS REPLACED, ETC. CLEARLY IDENTIFY ALL NEW WALLS. | | CLEARLY SPECIFY WHICH WINDOWS/DOORS ARE NEW AND WHICH | | WINDOWS/DOORS ARE REPLACED. SEC. 107.2.1 CITY | | AMENDMENTS. | | NOTE: FOR WINDOWS THAT ARE GOING TO BE REPLACED, | | CLEARLY SPECIFY THE SIZE AND TYPE OF EXISTING WINDOW | | AND SIZE AND TYPE OF PROPOSED WINDOWS, SPECIALLY THE | | BEDROOM WINDOWS TO VERIFY COMPLIANCE WITH THE EGRESS | | REQUIREMENTS SEC. 702.5 FBC-EXISTING BUILDING. | | | | 4- WINDOWS ON NEW BEDROOMS WHERE THE GARAGE USED TO BE | | DON'T COMPLY WITH THE EGRESS REQUIREMENTS OF SEC. | | R310.2.1 FBC-RESIDENTIAL. REVISE AS REQUIRED. CLEARLY | | SPECIFY THE WINDOWS SIZE (WIDTH AND HEIGHT) AND TYPE. | | | | 5- PROVIDE ENERGY CALCULATIONS (2 COPIES)AS REQUIRED BY | | SEC. 1106.1 FBC-EXISTING BUILDING. | | | | 6- ARCHITECT OF RECORD TO SHOW ON PLANS COMPLIANCE WITH | | THE HEATING REQUIREMENTS FOR THE NEW BEDROOMS AS | | REQUIRED BY SEC. R303.10 FBC-RESIDENTIAL. | | | | 7- ARCHITECT OF RECORD TO SHOW ON PLANS THE INSULATION | | R VALUES FOR WALLS AND CEILINGS AS REQUIRED BY SEC. | | R103.2 FBC-ENERGY CONSERVATION. NOTE: COORDINATE WITH | | ENERGY CALCULATIONS TO AVOID CONFLICTS/DELAYS. | | | | 8- ARCHITECT OF RECORD TO SPECIFY THE DESIGN PRESSURES | | FOR DOORS AND WINDOWS UNDER THE DESIGN CRITERIA | | PROVIDED. SEC. R301.2.1 FBC-RESIDENTIAL. | | | | 9- THERE IS A NOTE A THE BOTTOM RIGHT OF THE FLOOR PLAN | | STATING THAT "REPAIR OR REPLACE ALL EXISTING BUILDING | | COMPONENTS AS NEEDED". THIS STATEMENT IS TOO GENERAL. | | ARCHITECT TO CLERKLY IDENTIFY WHICH BUILDING COMPONENTS | | NEED TO BE REPLACED AND PROVIDE COMPLETE SPECIFICATIONS | | FOR NEW COMPONENT. SEC. 107.2.1 CITY AMENDMENTS. SEC. | | 801.3 FBC-EXISTING BUILDING AND SEC. 107.2.1 CITY | | AMENDMENTS. | | | | 10- ARCHITECT OF RECORD TO CLARIFY HOW ARE THE GARAGE | | DOORS OPENED TO ACCESS THE OUTSIDE STORAGE AREA SHOWN | | ON THE FLOOR PLAN.? SEC. 107.2.1 CITY AMENDMENTS. | | | | 11- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY | | FAC 61G20-3.001 FOR ALL NEW DOORS, WINDOWS AND DOORS | | AND WINDOWS TO BE REPLACED. AND, WINDOW MULLIONS | | (SPECIFY SIZE) AND SHUTTERS (WITH COMPLETE INSTALLATION | | SCHEDULE) IF DOORS AND WINDOWS DON'T HAVE IMPACT | | GLAZING. | | | | 12- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | 13- DIMENSION OF THE HALLWAY BETWEEN THE NEW BEDROOMS | | AND NEW BATHROOM IS NOT GIVEN. BASED ON THE SCALE | | PROVIDED, THE WIDTH OF THIS HALLWAY DOESN'T COMPLY WITH | | SEC. R311.6 FBC-RESIDENTIAL. PROVIDE DIMENSION ON FLOOR | | PLAN. (DIMENSION TO BE VERIFIED BY INSPECTOR). | | | | 14- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | LOW BASED ON THE SCOPE OF WORK. VALUATION TO INCLUDE | | ALL LABOR, MATERIALS, CONTRACTOR'S OVERHEAD AND PROFIT | | AND DESIGN PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 | | CITY AMENDMENTS. UPDATE VALUATION AS REQUIRED. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | SUBMIT OLD DRAWINGS FOR REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2019-05-17 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2019-05-17 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2019-05-17 |
Time |
15:17 |
Sent To |
|
|
Notes |
2019-05-17 15:18:52 | PLEASE SEE PROVISO |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2019-04-09 |
|
|
Cont ID |
|
Sent By |
jpearson |
Date |
2019-04-09 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
jpearson |
Date |
2019-04-09 |
Time |
10:10 |
Sent To |
|
|
Notes |
2019-04-09 10:59:44 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2017 6TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2017 | | 6TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2017 | | 6TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION | | NEC = NFPA 70 2014 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF | | PLAN IS REQUIRED TO BE SIGNED BY PERSON RESPONSIBLE FOR | | THE DESIGN. PROVIDE CORRECTION. FS 481.229; WPB FBC | | 107.1, 107.2.1, 107.3.5.1.2 | | 2. VALUE FOR WORK STATED ON PERMIT APPLICATION APPEARS | | LOW. PROVIDE COPY OF SIGNED CONTRACT WITH SCOPE AND | | VALUE OF WORK, TO INCLUDE ALL MATERIALS AND LABOR. THIS | | IS FOR TOTAL PROJECT, NOT JUST ELECTRICAL. WPB FBC | | 109.3 | | 3. PROVIDE ELECTRICAL PLAN FOR REVIEW, INDICATING | | EXISTING, NEW, AND RELOCATED LIGHTING AND RECEPTACLE | | OUTLETS. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR | | ALTERED CIRCUITS, THE WIRE AND BREAKER SIZE FOR THESE | | CIRCUITS, AND AFCI OR GFCI PROTECTION WHERE APPLICABLE | | TO COMPLY WITH CODE. NEC 210.8, 210.12, 210.19, 210.20, | | 215.5, 408.4; WPB FBC 107.3.5; FBC RE E3706.2, E3902 | | 4. PROVIDE RISER DIAGRAM, SHOWING ALL DETAILS OF | | SERVICE EQUIPMENT, UNDERGROUND OR OVERHEAD SERVICE, | | WIRE AND BREAKER SIZES FOR SERVICE AND FEED TO ANY | | SUB-PANEL(S). SHOW GEC SIZE AND SYSTEM, SHOW | | INTERSYSTEM BONDING TERMINATION POINT. NEC 215.5, 230, | | 250.50, 250.94, 408.30; FBC RE E3706.1, E3608.1, | | E3609.3; WPB FBC 107.2.1 | | 5. IF ANY LOAD IS BEING ADDED TO ELECTRICAL SYSTEM, | | PROVIDE LOAD CALCULATION FOR SERVICE, INCLUDE EXISTING | | AND NEW LOADS TO CONFIRM CAPACITY OF SERVICE IS | | ADEQUATE. NEC 215.2, 220, 408.30; FBC RE E3602.2 | | 6. PROVIDE SMOKE/CO ALARMS IN EACH LOCATION REQUIRED | | PER CODE. PROVIDE FULL FLOOR PLAN SHOWING ALL EXISTING | | ALARMS. IF NONE ARE EXISTING OR NOT TO CODE, SHOW AS | | NEW INSTALLATIONS. FBC RE R314.3, R315.1; WPB FBC | | 107.2.1 | | 7. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | NOTE WILL SUFFICE. NEC 406.12; FBC RE E4002.14 | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE THE PREVIOUSLY | | REVIEWED SHEETS. ONE COPY OF THE PREVIOUSLY REVIEWED | | SHEETS SHOULD REMAIN IN PACKAGE AND BE MARKED OLD | | SHEETS. | | | | SINCERELY, | | | | JOHN PEARSON | | ELECTRICAL PLANS EXAMINER | | 561-805-6746 | | [email protected] | | | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2019-06-04 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2019-06-04 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2019-06-04 |
Time |
11:11 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
F |
Date |
2019-05-22 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2019-05-22 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2019-05-22 |
Time |
14:01 |
Sent To |
PC |
|
Notes |
2019-05-22 14:01:25 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | 1. THE GARAGE DOORS SHALL REMAIN AS LOCATED OR NEW | | GARAGE DOORS SHALL BE INSTALLED. ILLUSTRATE THE GARAGE | | DOORS ON THE ELEVATION. IF NEW DOORS ARE PROPOSED, | | PROVIDE AN ILLUSTRATION OF THEIR APPEARANCE. | | 2. PROVIDE A SITE PLAN ILLUSTRATING THREE (3) | | OFF-STREET PARKING SPACES. EACH SPACE MUST HAVE A | | MINIMUM WIDTH OF 8.5 FEET AND A MINIMUM DEPTH OF 18 | | FEET. | | 3. PROVIDE A SITE PLAN ILLUSTRATING THAT ALL MECHANICAL | | EQUIPMENT DOES NOT PROJECT MORE THAN FOUR FEET INTO A | | SETBACK. (SEC 94-305 (B)(4)) THE REAR SETBACK FOR THIS | | PROPERTY IS 15 FEET OR 10% OF THE LOT DEPTH. A ROUGH | | CALCULATION SHOWS A 100-FOOT DEPTH LOT, REQUIRING A | | MINIMUM REAR SETBACK OF 10 FEET. THE MECHANICAL | | EQUIPMENT TO THE PROPERTY LINE SHALL REQUIRE A MINIMUM | | DISTANCE OF SIX (6) FEET. A SURVEY IS REQUIRED TO | | VERIFY THE EXACT LOCATION OF THE REAR PROPERTY LINE AND | | DISTANCE TO THE STRUCTURE. | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | HISTORIC PRESERVATION PLANNER AT [email protected] | | | | AARON BORNGRABER | | HISTORIC PRESERVATION PLANNER | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | T: 561-822-1428 | | [email protected] | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2019-04-15 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2019-04-15 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2019-04-12 |
Time |
11:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2019-06-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-06-06 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-05-29 |
Time |
15:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2019-05-22 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2019-05-22 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2019-05-07 |
Time |
14:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2019-04-15 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2019-04-15 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2019-03-22 |
Time |
14:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2019-05-20 |
|
|
Cont ID |
|
Sent By |
jduprey |
Date |
2019-05-20 |
Time |
09:15 |
Rev Time |
0.00 |
Received By |
jduprey |
Date |
2019-05-17 |
Time |
09:50 |
Sent To |
|
|
Notes |
2019-05-20 09:16:20 | MU-2019-012144-0000 | | $236.59 PAID |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2019-04-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-04-11 |
Time |
18:15 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-04-11 |
Time |
18:14 |
Sent To |
|
|
Notes |
2019-04-11 18:16:03 | IMPACT FEES - PAPER SUBMITTALS | | | | PLANS REQUIRE REVIEW BY THE PBC IMPACT FEE OFFICE. CALL | | (561) 233-5025. UPON APPROVAL OF PLANS, YOU MAY CHECK | | OUT ONE PLAN SET AND TAKE TO THAT OFFICE FOR REVIEW. | | PLEASE RETURNED STAMPED AND WITH A COPY OF THE RECEIPT | | AS APPLICABLE. PLEASE PROVIDE THE MUNICIPAL IMPACT FEE | | QUESTIONNAIRE FORM TO THE PBC IMPACT FEE OFFICE. THE | | FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/AD | | MINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2019-05-22 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-05-22 |
Time |
07:38 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-05-17 |
Time |
09:50 |
Sent To |
|
|
Notes |
2019-05-22 07:39:22 | PROVISO ON PLAN. PROVIDE MANUFACTURERES SPECIFCATIONS | | AT INSPECTION. CT |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2019-04-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-04-10 |
Time |
16:13 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2019-04-10 |
Time |
16:13 |
Sent To |
|
|
Notes |
2019-04-10 16:27:43 | RESIDENTIAL (R3) ADDITION/ALTERATION MECHANICAL REVIEW | | COMMENTS | | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. | | | | NOTE: | | SUBMIT ALL THE INFORMATION OR CONTRACTOR TO ADVICE IF | | PROVIDING COMPLETE INFORMATION UNDER A SEPARATE PERMIT. | | | | 1- PROVIDE COMPLETE MECHANICAL PLANS SHOWING ALL THE | | DUCTWORK AND EQUIPMENT, ETC. CLEARLY SPECIFY EQUIPMENT | | MANUFACTURER, MODEL, CAPACITY, ETC. 107.3.5.3 (11) CITY | | AMENDMENTS. | | | | 2- PROVIDE COMPLETE EQUIPMENT SIZING CALCULATIONS BASED | | ON BUILDING LOADS FOR THE DIRECTIONAL ORIENTATION OF | | THE BUILDING. AND, THE MANUFACTURER'S AND MODEL NUMBER | | SHALL BE SUBMITTED ALSO, ALONG WITH THE SENSIBLE AND | | TOTAL COOLING CAPACITIES AS REQUIRED BY SEC. R403.7.1 | | FBC-ENERGY CONSERVATION. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND | | REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS. | | PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD | | DRAWINGS/DOCUMENTS FOR REFERENCE. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2019-06-06 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2019-06-06 |
Time |
14:22 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2019-06-06 |
Time |
13:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2019-05-09 |
|
|
Cont ID |
|
Sent By |
gjohnson |
Date |
2019-05-09 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
gjohnson |
Date |
2019-05-09 |
Time |
15:55 |
Sent To |
|
|
Notes |
2019-05-09 16:50:48 | 1ST REVIEW: | | 2017 FLORIDA BUILDING CODE 6TH EDITION | | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION | | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH | | EDITION | | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH | | EDITION | | | | PLUMBING COMMENTS: PREVIOUS COMMENT NOT COMPLIED NO | | CONTRACT PROVIDED | | | | | | VALUE SEEMS LOW. PROVIDE A SIGN BONA FIDE CONTRACT. | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE | | | | | | GEORGE JOHNSON | | PLUMBING PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561-805-6711 | | [email protected] | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2019-04-05 |
|
|
Cont ID |
|
Sent By |
thunt |
Date |
2019-04-05 |
Time |
13:51 |
Rev Time |
0.00 |
Received By |
thunt |
Date |
2019-04-05 |
Time |
13:51 |
Sent To |
|
|
Notes |
2019-04-05 13:54:04 | PLUMBING 1ST REVIEW**DENIED** | | | | 1) PROVIDE A EXISTING FLOOR PLAN AND SCOPE OF WORK TO | | INCLUDE PLUMBING ISOMETRIC DRAWING. FBC 107.3.5 | | | | 2) PERSON DESIGNING PLAN SHALL TAKE OWNERSHIP. F.S 471 | | | | 3) SUB PLUMBING PERMIT REQUIRED. | | | | 4) VALUE SEEMS LOW. PROVIDE A SIGN BONA FIDE CONTRACT. | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE | | | | TIM HUNT | | PLUMBING PLANS EXAMINER/ PLUMBING INSPECTOR | | CITY OF WEST PALM BEACH | | 561-248-2703 | | [email protected] | | [email protected] | | | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2019-06-04 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2019-06-04 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2019-06-04 |
Time |
11:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2019-05-22 |
|
|
Cont ID |
|
Sent By |
aborngra |
Date |
2019-05-22 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2019-05-22 |
Time |
14:01 |
Sent To |
PC |
|
Notes |
2019-05-22 14:01:44 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | 1. THE GARAGE DOORS SHALL REMAIN AS LOCATED OR NEW | | GARAGE DOORS SHALL BE INSTALLED. ILLUSTRATE THE GARAGE | | DOORS ON THE ELEVATION. IF NEW DOORS ARE PROPOSED, | | PROVIDE AN ILLUSTRATION OF THEIR APPEARANCE. | | 2. PROVIDE A SITE PLAN ILLUSTRATING THREE (3) | | OFF-STREET PARKING SPACES. EACH SPACE MUST HAVE A | | MINIMUM WIDTH OF 8.5 FEET AND A MINIMUM DEPTH OF 18 | | FEET. | | 3. PROVIDE A SITE PLAN ILLUSTRATING THAT ALL MECHANICAL | | EQUIPMENT DOES NOT PROJECT MORE THAN FOUR FEET INTO A | | SETBACK. (SEC 94-305 (B)(4)) THE REAR SETBACK FOR THIS | | PROPERTY IS 15 FEET OR 10% OF THE LOT DEPTH. A ROUGH | | CALCULATION SHOWS A 100-FOOT DEPTH LOT, REQUIRING A | | MINIMUM REAR SETBACK OF 10 FEET. THE MECHANICAL | | EQUIPMENT TO THE PROPERTY LINE SHALL REQUIRE A MINIMUM | | DISTANCE OF SIX (6) FEET. A SURVEY IS REQUIRED TO | | VERIFY THE EXACT LOCATION OF THE REAR PROPERTY LINE AND | | DISTANCE TO THE STRUCTURE. | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | HISTORIC PRESERVATION PLANNER AT [email protected] | | | | AARON BORNGRABER | | HISTORIC PRESERVATION PLANNER | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | T: 561-822-1428 | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2019-04-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2019-04-16 |
Time |
09:23 |
Rev Time |
0.00 |
Received By |
aborngra |
Date |
2019-04-15 |
Time |
10:33 |
Sent To |
PC |
|
Notes |
2019-04-15 10:39:01 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S): | | | | 1. PROVIDE A SITE PLAN ILLUSTRATING THREE (3) | | OFF-STREET PARKING SPACES. EACH SPACE MUST HAVE A | | MINIMUM WIDTH OF 8.5 FEET AND A MINIMUM DEPTH OF 18 | | FEET. | | | | | | | | FOR A FASTER RESPONSE, PLEASE EMAIL AARON BORNGRABER, | | HISTORIC PRESERVATION PLANNER AT [email protected]. | | | | AARON BORNGRABER | | HISTORIC PRESERVATION PLANNER | | CITY OF WEST PALM BEACH - DEVELOPMENT SERVICES | | T: 561-822-1428 | | [email protected] | | |
|
|
|