Plan Review Details - Permit 19030972
Plan Review Stops For Permit 19030972
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2019-06-06 Cont ID  
Sent By jgomez Date 2019-06-06 Time 17:37 Rev Time 0.00
Received By jgomez Date 2019-06-06 Time 13:40 Sent To  
Notes
2019-06-06 17:24:24BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- SPECIFY ALL STRUCTURAL CONNECTORS FOR ALL INFILL
 EXTERIOR WALLS IN NEW KITCHEN.
 2- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR:
 A) SINGLE HUNG WINDOW SIZE (5'-2"WIDTH X 4'-6" HEIGHT )
 SPECIFIED ON THE WINDOW SCHEDULE FOR WINDOW W-112.
 B) WINDOW MULLIONS (IF USED) PLANS ARE NOT CLEAR. AND,
 CLEARLY SPECIF MULLION SIZE TO VERIFY COMPLIANCE WITH
 THE CALCULATED DESIGN PRESSURES.
 C) FRONT DOOR PRODUCT APPROVAL SUBMITTED IS INCOMPLETE.
 NEED TO PROVIDE COMPLETE FLORIDA PRODUCT APPROVAL (2
 COPIES), INCLUDING THE FLORIDA PRODUCT APPROVAL COVER
 PAGE THAT CORRESPONDS TO THE DRAWINGS SUBMITTED. THE
 FLORIDA PRODUCT APPROVAL IS REQUIRED BECAUSE IT SHOWS
 IF PRODUCT IS APPROVED AND CURRENT CODE IN EFFECT.
 3- DESIGNER OF RECORD TO APPROVE ALL PRODUCT APPROVALS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2019-04-17 Cont ID  
Sent By jgomez Date 2019-04-17 Time 11:54 Rev Time 0.00
Received By jgomez Date 2019-04-17 Time 09:36 Sent To  
Notes
2019-04-17 11:55:23RESIDENTIAL (R3) ADDITION/ALTERATION BUILDING REVIEW
 COMMENTS
 CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS.
  
 NOTE: ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS,
 SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS
 OF THE FLORIDA BUILDING CODE, BUILDING.
 SEC. 801.3 FBC-EXISTING BUILDING.
  
 1- NEW MASTER BEDROOM: CLEARLY SPECIFY SIZE AND TYPE OF
 EGRESS WINDOW TO VERIFY COMPLIANCE WITH THE CLEAR
 OPENING REQUIREMENTS OF SEC. R310.2.1 FBC-RESIDENTIAL.
 NOTE: PLANS SUBMITTED ONLY SPECIFY EGRESS WINDOWS, BUT
 DON'T SPECIFY TYPE AND SIZE.
  
 2- SPECIFY TYPE AND SIZE OF EXISTING WINDOWS (SPECIALLY
 THE BEDROOM WINDOWS) TO BE REPLACED AND TYPE AND SIZE
 OF PROPOSED WINDOW TO VERIFY COMPLIANCE WITH THE EGRESS
 REQUIREMENTS OF SEC. 702.5 FBC-EXISTING BUILDING.
 NOTE: PLANS SUBMITTED ONLY SPECIFY EGRESS WINDOWS, BUT
 DON'T SPECIFY TYPE AND SIZE.
  
 3- ARCHITECT TO PROVIDE ALL THE WIND DESIGN CRITERIA AS
 REQUIRED BY SEC. R301.2.1 FBC-RESIDENTIAL. SPECIFY THE
 ULTIMATE AND NOMINAL WIND LOAD, BUILDING EXPOSURE,
 BUILDING MEAN ROOF HEIGHT. ALSO, SPECIFY THE COMPONENTS
 AND CLADDING DESIGN PRESSURES FOR DOORS AND WINDOWS.
  
 4- PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS
 FOR ALL RELOCATED WINDOWS. CLEARLY SPECIFY ALL FRAMING
 MEMBERS AND ALL CONNECTORS. PLANS SUBMITTED DON'T
 PROVIDE ANY STRUCTURAL INFORMATION. SEC. R301.2.1
 FBC-RESIDENTIAL.
  
 5- PROVIDE COMPLETE FRAMING DETAILS AND SPECIFICATIONS
 FOR ALL INFILL EXTERIOR WALLS. CLEARLY SPECIFY ALL
 FRAMING MEMBERS AND ALL CONNECTORS. THIS APPLIES TO
 INTERIOR WALL PARTITIONS ALSO. CONNECTORS WERE NO
 SPECIFIED ON DETAIL PROVIDED. PLANS SUBMITTED DON'T
 PROVIDE ANY STRUCTURAL INFORMATION. SEC. R301.2.1
 FBC-RESIDENTIAL.
  
 6- REVISE SPECIFICATIONS SHOWN ON TYPICAL NEW INFILL
 EXTERIOR WALL ON SHEET A-001.
 A)NEED TO SPECIFY 2 LAYERS OF WATER RESISTIVE BARRIERS
 AS REQUIRED BY SEC. R703.7.3 WATER-RESISTIVE BARRIERS.
  
 B)NEED TO SPECIFY THE 7/8" MIN. STUCCO THICKNESS (NOT
 3/4") AS REQUIRED BY TABLE R702.1(1).
  
 7- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY
 FAC 61G20-3.001 FOR:
 A) CASEMENT WINDOWS. NOA 17-1212.22 SUBMITTED EXPIRED
 ON MARCH 04/2019. NEED TO PROVIDE CURRENT PRODUCT
 APPROVAL.
  
 B) WINDOW MULLIONS (IF USED) PLANS ARE NOT CLEAR.
 COORDINATE WITH ITEMS #1 AND #2 ABOVE.
 AND, CLEARLY SPECIF MULLION SIZE TO VERIFY COMPLIANCE
 WITH THE CALCULATED DESIGN PRESSURES.
  
 C) FRONT DOOR PRODUCT APPROVAL SUBMITTED IS INCOMPLETE.
 NEED TO PROVIDE COMPLETE FLORIDA PRODUCT APPROVAL (2
 COPIES), INCLUDING THE FLORIDA PRODUCT APPROVAL COVER
 PAGE THAT CORRESPONDS TO THE DRAWINGS SUBMITTED. THE
 FLORIDA PRODUCT APPROVAL IS REQUIRED BECAUSE IT SHOWS
 IF PRODUCT IS APPROVED AND CURRENT CODE IN EFFECT.
  
 8- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE, INSERT CORRECTED PAGES INTO THE SUBMITTAL AND
 REMOVE/VOID THE PREVIOUSLY REVIEWED SHEETS.
 PLEASE DON'T STAPLE OLD DRAWINGS/DOCUMENTS . SUBMIT OLD
 DRAWINGS/DOCUMENTS FOR REFERENCE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2019-04-15 Cont ID  
Sent By jpearson Date 2019-04-15 Time 09:51 Rev Time 0.00
Received By jpearson Date 2019-04-15 Time 09:14 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2019-06-05 Cont ID  
Sent By fmittner Date 2019-06-05 Time 13:48 Rev Time 0.00
Received By fmittner Date 2019-06-05 Time 13:48 Sent To B
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2019-04-11 Cont ID  
Sent By fmittner Date 2019-04-11 Time 13:58 Rev Time 0.00
Received By fmittner Date 2019-04-11 Time 13:58 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-06-06 Cont ID  
Sent By jgomez Date 2019-06-06 Time 17:37 Rev Time 0.00
Received By jgomez Date 2019-05-15 Time 14:51 Sent To I
Notes
2019-05-16 14:51:16ROUTED TO HISTORIC INBOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-04-17 Cont ID  
Sent By jgomez Date 2019-04-17 Time 11:55 Rev Time 0.00
Received By jgomez Date 2019-03-20 Time 15:36 Sent To I
Notes
2019-03-21 15:37:10**TRAVELLING WITH 19030973**
2019-03-21 15:36:47R10

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2019-04-15 Cont ID  
Sent By hmoser Date 2019-04-15 Time 13:30 Rev Time 0.00
Received By hmoser Date 2019-04-15 Time 13:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2019-04-02 Cont ID  
Sent By thunt Date 2019-04-02 Time 15:21 Rev Time 0.00
Received By thunt Date 2019-04-02 Time 15:21 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2023-03-17 Cont ID  
Sent By shill Date 2019-06-06 Time 19:40 Rev Time 0.00
Received By shill Date 2019-06-06 Time 19:40 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2019-04-11 Cont ID  
Sent By fmittner Date 2019-04-11 Time 13:59 Rev Time 0.00
Received By fmittner Date 2019-04-11 Time 13:59 Sent To  
Notes
***NONE***