Plan Review Details - Permit 19030842
Plan Review Stops For Permit 19030842
Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2019-05-09 Cont ID  
Sent By thunt Date 2019-05-09 Time 14:21 Rev Time 0.00
Received By thunt Date 2019-05-08 Time 10:32 Sent To  
Notes
2019-05-09 10:32:24RESUB ROUTED TO THUNT

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2019-03-20 Cont ID  
Sent By thunt Date 2019-03-20 Time 06:42 Rev Time 0.00
Received By thunt Date 2019-03-18 Time 12:50 Sent To  
Notes
2019-03-19 12:51:09PLUMB <5K

Review Stop P PLUMBING
Rev No 2 Status P Date 2019-05-09 Cont ID  
Sent By thunt Date 2019-05-09 Time 14:21 Rev Time 0.00
Received By thunt Date 2019-05-09 Time 14:20 Sent To  
Notes
2019-05-09 14:21:52VERIFIED INFORMATION WITH ANDY(561) 628-1391 VALUE
 CHANGED TO $3200.00

Review Stop P PLUMBING
Rev No 1 Status F Date 2019-03-20 Cont ID  
Sent By thunt Date 2019-03-20 Time 06:42 Rev Time 0.00
Received By thunt Date 2019-03-20 Time 06:42 Sent To I
Notes
2019-03-20 06:42:37PLUMBING 1ST REVIEW**DENIED**NOTE - A COMPREHENSIVE
 REVIEW COULD NOT BE DONE AT THIS TIME AND ADDITIONAL
 PLAN REVIEW COMMENTS MAY BE GENERATED UPON THE
 RE-REVIEW OF SUBMITTED CORRECTIONS.
  
 1) VALUE OF JOB SEEMS LOW. PLEASE PROVIDE A SIGNED
 CONTRACT FOR THIS JOB.109.3 BUILDING PERMIT VALUATIONS.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATIONOF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL OR PLUMBING SYSTEMS APPEARS
 TO BE UNDERESTIMATED ON THE APPLICATION, THE PERMIT
 SHALL BE DENIED, UNLESS THE APPLICANT CAN SHOW
 DETAILED, QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED
 CONTRACTS (EXCLUDING LAND VALUE) TO MEET THE APPROVAL
 OF THE BUILDING OFFICIAL. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC,
 PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE
 WORK, ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
  
 2) PERSON DRAWING PLANS SHALL SIGN AND DATE.FBC 107.1
  
 3) AAV WOULD NOT BE PERMITTED AS THIS IS A SEPERATE
 BUILDING DRAIN CONNECTING TO THE SEWER. PER FBC-P 904.1
 THE VENT SYSTEM SERVING EACH BUILDING DRAIN SHALL HAVE
 NOT LESS THEN ONE VENT PIPIE THAT EXTEND TO THE
 OUTDOORS.
  
 4) PLANS DO NOT INDICATE IF THESE SINKS ARE NEW OR
 EXISTING. WHERE IS THE HOT AND COLD WATER COMING FROM?
 FBC 107.1
  
  
 TIM HUNT
 PLUMBING INSPECTOR/PLUMBING PLAN EXAMINER
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 561-248-2703
 [email protected]
  
  
  
  